Professional Documents
Culture Documents
Pump Sizing Calculation: Tag No. P-101 Description Feed Pump Date 28-Jan-15 by Checalc
Pump Sizing Calculation: Tag No. P-101 Description Feed Pump Date 28-Jan-15 by Checalc
Piping Piping
Length L1 120.0 ft Length L2 2000.0 ft
Pipe Diameter 3 inch Pipe Diameter 3 inch
Sch/ Thick 40 Sch/ Thick 40
Pipe ID ID1 3.068 inch Pipe ID ID2 3.068 inch
180 45
Efficiency (%)
160 40
Head (ft)
140 35
120 30
100 25
80 20
60 15
40 10
20 5
0 0
0.0 20.0 40.0 60.0 80.0 100.0 120.0 140.0 160.0 180.0 200.0
Flow (US gpm)
100 25
80 20
60 15
Piping Piping
Length L1 36.6 m Length L2 609.6 m
Pipe Diameter 3 inch Pipe Diameter 3 inch
Sch/ Thick 40 Sch/ Thick 40
Pipe ID ID1 77.93 mm Pipe ID ID2 77.93 mm
45
70
Efficiency (%)
40
60
Head (m)
35
50
30
40 25
20
30
15
20
10
10
5
0 0
0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0
Flow (m3/h)
40 25
20
30
15
20
PUMP SIZING CALCULATION 10
CheCalc.com Tag No. P-101
10
Chemical Engineering Calculations Description 5
Feed Pump
Date 28-Jan-15
0 0
User Input 0.0 5.0 10.0 15.0 20.0 25.0 30.0 By 40.0
35.0 45.0 50.0 Checalc
Flow (m3/h)