Safety Standred As Per OSHAs 18001 & Factory Act
Safety Standred As Per OSHAs 18001 & Factory Act
1) T h e h e i g h t o f t h e T o e g u a r d s s h o u l d b e a t l e a s t 1 5 0 m m
2) T h e h e i g h t o f t h e f i r s t h o r i z o n t a l b a r o f t h e h a n d r a i l i n g s h o u l d n o t b e
more than 1 m
3) T h e h e i g h t o f t h e F i r e E x t i n g u i s h e r f r o m t h e f l o o r s h o u l d b e
1m
5) S p e e d l i m i t f o r t h e v e h i c l e s i n s i d e t h e p l a n t s h o u l d n o t e x c e e d 1 0
miles per hour (16 Kmph)
6) T h e m i n i m u m L u x l e v e l ( I l l u m i n a t i o n l e v e l ) t o b e p r e s e n t o n t h e s h o p
floor should be 200 - 300 Lux
7) T h e m i n i m u m h e i g h t f o r w e a r i n g t h e h a r n e s s ( S a f e t y b e l t ) s h o u l d b e
4 ft
9) M a t e r i a l h a n d l i n g e q u i p m e n t s s u c h a s F o r k l i f t s a n d C l a m p t r u c k s t o
be inspected once in a year
11) The maximum safe load shall be plainly marked on every lift & hoist and no load
grater than that shall be carried
13) All vessels shall be hydraulically tested by a competent person at a pressure
marked on the vessel at intervals of not more than 5 years.