You are on page 1of 4
Fire Safety Audit - Cholarisk Page | sur 4 $}Chola@Ms RISK SERVICES. TYPE YOUR SEA\ SERVICES INDUSTRIES ABOUT CAREERS CONTACT FIRE SAFETY AUDIT Home » Services Process Safety Fire Safety Fire Safety Audit Process Safety Process Safety Management (PSM) HAZOP,GRAand = Objective: other PHA studies £ To carry out a systematic, critical appraisal of all potential Fire Fire Safety hazards involving personnel, premises, services & operation method Design of Fire A F aan £ To ensure that occupational Safety & Health System fully ‘Alarm Systems satisfy the legal requirements and those of companys written safety policies , objectives & progress Design of Fire Protection Scope of Work Gea Fire Hazard Identification Fire & Gas Identifying potential fire / explosion hazards / risks in the Detection Premises and suggesting appropriate preventive measures Mapping Study Evaluate the Fire risk in each operation / area. Fire Water Network Analysis Fire fighting system rive Risk # Evaluate the location of the Fire pump house and water oe storage tank to meet the Statute and standard requirements and the availability of nearby hazards. Fire Hazard e Management http:/Avww.cholarisk.com/services/process-safety/fire-safety/fire-safety-audit/ 23/09/2016 Fire Safety Audit - Cholarisk Fire Safety Audit Page 2 sur 4 Adequacy of the underground and above ground fire water tank and pumping capacity, Availability of Overhead Support and tank and its interconnection with Fire water network, and Monitoring of Fire backup supply Protection system Execution Configuration of the pumps and valves for the hydrant and and sprinkler system Commissioning @ Checking the Adequacy of the sprinkler system, eer detection system, operating temperature / other parameter Safety Fire detection and alarm system Management # Adequacy of the Fire detection and alarm (FDA) system oe with respect to relevant standards, positioning of the oars detectors with respect to ventilation system, beam. depth, obstructions, etc. ome Integrity Checking the availability and adequacy of the backup power evel supply to FDA panel and other electrically operated Safety emergency equipments AuditReview # Type of cables used for emergency service. Environment Gas suppression system Consulting # Assess the requirement of Gas suppression system based on Construction fire risk and criticality of the equipments / operations as per Safety relevant standards. Electrical * Assessing the location of the Gas suppression cylinders, Safety routing of pipeline, location of manual release and abort Logistics Safety switches and panel, Standby power supply, etc. Fire extinguisher Insurance Support 2 Services e Checking the adequacy and deployment of the portable Fire extinguisher as per relevant standards. Accessibility to extinguishers as per relevant standards and availability of refills, mounting practice, etc. Passive fire protection e I~ http://www. cholarisk.com/services/proct Segregation of the facilities and utilities, requirement of fire partition walls and its fire rating Segregation of power cables and data cables and utilities lines afety/fire-safety/fire-safety-audit/ 23/09/2016 Fire Safety Audit - Cholarisk Page 3 sur 4 ~ Addressing the fire spread through vertical and horizontal openings meant for cable passes, utility lines, etc. I. Fire rating of the emergency exit doors, Fire lifts, etc. i~ Fire rating of building construction, internal partitions and false ceilings. Emergency Management & Life Safety System £ Availability of Emergency preparedness plan # Adequacy of emergency exit based on occupant load / type of occupancy / type of exit, ~ Adequacy and availability of emergency lights and ventilation ~ Segregation of the emergency exit from the remaining facility. I Communication of emergency, Mutual Aid, etc. i Approach road width and clearance, ~ Access and egress to the building. I~ Open space around the building, i Adequacy of siganges. I. Assess the requirement of passive fire protection system like cable pass sealants, etc. I Assessment of fire safety training level of security staff, and facility management staff. i Assessment of emergency plan, fire mockup drill records, evacuation plan and its adequacy. Methodology Reporting & Recommendations : ‘At the end of field study, a Fire Safety Audit report will be provided on the findings of the study and recommendations for next course http:/Avww.cholarisk.com/services/process-safety/fire-safety/fire-safety-audit/ 23/09/2016 Fire Safety Audit - Cholarisk Page 4 sur 4 of action. The recommendations suggested for risk improvement would be categorized as Category A, B and C. The criterion for categorization is presented as follows: + Recommendations that are provided to address existing statutory non-compliance, deviation from standard operating procedures ooregy defined bythe company etc, «+ Recommendations that are provided hazed on good engineering practices followed in similar industry SERVICES INDUSTRIES ABOUT sides au) Eades) Cholamandalam MS Risk Services Limited Ajoint venture between Murugappa Group, India MSIG MUFUGAPPA —_& Mitsui Sumitomo Insurance Group, Japan +491 443044 5620-30 inquiry@cholams.murugappa.com Toll Free 1800 200-1991 © 2016 Cholamandalam MS Risk Services Limited. All rights Reserved http:/Avww.cholarisk.com/services/process-safety/fire-safety/fire-safety-audit/ 23/09/2016

You might also like