Professional Documents
Culture Documents
Correspondence results of this study indicate that Ketac Molar Easymix is not
Kürşat Er, DDS, PhD suitable material for temporary filling. Other materials can be
Department of Endodontics, used, but should be considered their variable leakage rates.
Faculty of Dentistry, Akdeniz University,
Key words: Access Cavity, Coronal Microleakage, Temporary
07058 Antalya, Turkey.
Fillings
Phone: +90 242 310 69 82
Fax: +90 242 310 69 67 Submitted for Publication: 01.07.2013
E-mail. kursater@akdeniz.edu.tr Accepted for Publication : 06.11.2013
23
CLINICAL DENTISTRY AND RESEARCH 2013; 37(2): 23-28 Orjinal Araştırma
24
Coronal microleakage of various temporary fillings.
25
CLINICAL DENTISTRY AND RESEARCH
Coltene/Whaledent, Altstätten,
DuoTEMP Zinc oxide, urethane dimetacrylate, zinc sulphate monohydrate
Switzerland
TempBond Clear Base: uncured urethane diacrylate, monomers, Catalyst: dibutyl phthalate,
Kerr, Orange, CA, USA
with Triclosan monomers, uncured urethane diacrylate, monomers
Zinc oxide, calcium sulphate, zinc sulphate, glycol acetate, polyvinyl acetate resin,
Cavit G 3M ESPE, Seefeld, Germany
polyvinyl chloride acetate, triethanolamine, colour pigment
Coltene Whaledent, Langenau,
Coltosol F Zinc oxide, calcium sulphate, zinc sulphate, ethylene vinyl acetate copolymer
Germany
BMS Zinc oxide, calcium sulphate BMS Dental, Capannoli, Italy
Ketac Molar Powder: Al-Ca-La fluorosilicate glass, copolymer acid (acrylic and maleic acid),
3M ESPE, Seefeld, Germany
Easymix Liquid: Polyalkenoic acid, tartaric acid, water
the positive control group were coated with two layers of Furthermore, dichotomous comparisons were made using
nail varnish except for 1 mm around the tooth-restoration the Mann-Whitney U test with Bonferroni correction in order
interface. to determine the groups between which the difference was
Coronal Leakage Test and Analysis present (p≤ 0.05).
26
Coronal microleakage of various temporary fillings.
Leakage scores
Median Min. Max.
Groups 0 1 2 3
a
Cavit G - 10 - - 1 1 1
a
Coltosol F - 10 - - 1 1 1
a
BMS - 10 - - 1 1 1
a,b
Fermin - 5 5 - 1,5 1 2
c
Ketac M. Easymix - - - 10 3 3 3
a,b
Clip - 7 3 - 1 1 2
b
Pro-Fill - - 10 - 2 2 2
a
DuoTEMP - 10 - - 1 1 1
a,b
TempBond Clear - 6 4 - 1 1 2
Negative Controld 5 - - - 0 0 0
Positive Controle - - - 5 3 3 3
high-viscosity glass ionomers. The results of the present Similar to the result of Ciftci et al.12 we found that Clip
study are in agreement with other studies showing that seals against marginal leakage as effectively as Cavit-G.
glass ionomer cement has a gross microleakage when used DuoTEMP is one of the first dual-cure TFs. It is eugenol-
as a TF.12,15,16 Cavit-G, Coltosol F, BMS, DuoTEMP Fermin, Clip free, radiopaque and is formulated from zinc oxide and zinc
and TempBond Clear with Triclosan showed least leakage, sulphate. In spite of the dual-cure property, similar to results
whereas Ketac Molar Easymix showed complete leakage of Hartwell et al.18 DuoTemp did not show superiority to
along the filling-tooth interface up to the endodontic cavity. hydraulic TFs. TempBond Clear with Triclosan is a dual-
Cavit-G, Coltosol F, BMS and Fermin are premixed TFs which cured resin based dental temporary cement and restorative
contain dominantly zinc oxide. These materials are hydraulic material, available in a convenient automix syringe, it
TFs. They have hygroscopic properties causing them to offers a dual cure for added security and flexibility, ease
expand and set when they come in contact with moisture.9 of handling, and easy removal from preparations. There is
This expansion probably causes the material to adapt better no information about whether this material is efficient to
against the dentin walls and this adaption provides a good provide satisfactory sealing endodontic access preparations.
seal under different conditions including thermo cycling.9,17 Under the conditions of the present study, results indicate
Several studies found that hydraulic materials ensured an that TempBond Clear with Triclosan seals against marginal
adequate seal if used in a thickness of at least 3.5 mm.11,12 leakage as effectively as Clip and Fermin, leaked significantly
In this study a thickness of 4 mm of restorative material lower than Pro-Fill and Ketac Molar Easymix but higher than
inserted in all specimens. DuoTEMP, BMS, Coltosol and Cavit-G when used as a TF.
Pro-Fill and Clip are noneugenol-containing, light-activated The major drawback of this study is that the experimental
diurethane dimethacrylate resins. However, under the design did not totally mimic actual clinical conditions (e.g. the
conditions of this study Clip showed superiority to Ketac present study evaluation of the materials with four dentinal
Molar Easymix (p ≤ 0.05) and similar results with other walls, lack of saliva and masticatory forces). The thickness
experimental groups (p> 0.05) whereas Pro-Fill showed less of each material and the method of accessing each tooth
effective seal than Cavit-G, Coltosol F, BMS and DuoTemp. were standardized, however it was impossible to control
27
CLINICAL DENTISTRY AND RESEARCH
the exact volume of TF used in each tooth. The materials 9. Tames A, Ben-Amar A, Gover A. Sealing properties of temporary
in the study were not applied uniformly at standard volume; filling materials used in endodontics. J Endod 1982; 8: 322-325.
this could have potentially affected the results because
10. Lee YC, Yang SF, Hwang YF, Chueh LH, Chung KH. Microleakage
leakage in TFs might occur either at the tooth-material of endodontic temporary restorative materials. J Endod 1993; 19:
interface or through the material itself.14 However, the data 516-520.
provide useful preliminary information about the sealing
11. Zmener O, Banegas G, Pameijer CH. Coronal microleakage of
properties of the materials.11 Because an ideal TF should
three temporary restorative materials: an in vitro study. J Endod
possess a combination of long-term bacterial sealing ability
2004; 30: 582-584.
with adequate mechanical properties, further clinical and
laboratory experiments are recommended to test the ability 12. Ciftci A, Vardarli DA, Sönmez IS. Coronal microleakage of four
of dual-cured temporary restorative material DuoTEMP to endodontic temporary restorative materials: an in vitro study. Oral
Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: e67-70.
seal against bacteria and to withstand mechanical loading.
The authors deny any conflicts of interest. 15. Hagemeier MK, Cooley RL, Hicks JL. Microleakage of five
temporary endodontic restorative materials. J Esthet Dent 1990; 2:
REFERENCES 166-169.
1. Rödig T, Hülsmann M. Restorative materials for the temporary
16. Beckham BM, Anderson RW, Morris CF. An evaluation of three
seal of the endodontic access cavity. Endo 2008; 2: 117-130.
materials as barriers to coronal microleakage in endodontically
2. Cruz EV, Shigetani Y, Ishikawa K, Kota K, Iwaku M, Goodis HE. treated teeth. J Endod 1993; 19: 388-391.
A laboratory study of coronal microleakage using four temporary
17. Chohayeb AA, Bassiouny MA. Sealing ability of intermediate
restorative materials. Int Endod J 2002; 35: 315-320.
restoratives used in endodontics. J Endod 1985; 11: 241-244.
3. Weber RT, del Rio CE, Brady J, Seagall RO. Sealing quality of a
18. Hartwell GR, Loucks CA, Reavley BA. Bacterial leakage of
temporary filling material. Oral Surg Oral Med and Oral Pathol 1978;
provisional restorative materials used in endodontics. Quintessence
46: 123-130.
Int 2010; 41: 335-339.
4. Deveaux E, Hildelbert P, Neut C, Boniface B, Romond C.
Bacterial microleakage of Cavit, IRM, and TERM. Oral Surg Oral Med
Oral Pathol 1992; 74: 634-642.
28