h i g h l i g h t s g r a p h i c a l a b s t r a c t
a r t i c l e i n f o a b s t r a c t
Article history: Fluid Catalytic Cracking (FCC) is one of the most important conversion processes used in refineries all
Received 30 August 2016 over the world. It is used for the conversion of heavy oil feed with high boiling temperature to produce
Received in revised form 14 November 2016 gasoline, diesel, propylene and other valuable products. Coke deposits on the catalyst during the catalytic
Accepted 15 December 2016
conversion and deactivates it, therefore catalyst is continuously regenerated in the FCC process. The
Available online 26 December 2016
regeneration step is essential as it directly impacts the products yields. The coke combustion also gener-
ates NOx and SOx emissions which levels are highly influenced by the bed hydrodynamics, the operation
Keywords:
parameters and the reactor configuration, and are important to quantify. For all these reasons, the under-
Fluid Catalytic Cracking (FCC)
FCC regenerator
standing of the regenerator hydrodynamic and kinetic is essential.
Coke combustion kinetics This paper presents a study on the coupling of BarracudaTM CFD code with a coke combustion kinetic
Hydrodynamic model developed at IFP Energies nouvelles to simulate an industrial FCC regenerator. Regenerator oper-
Heat transfer ating and performance data, including catalyst samples for coke analysis, are acquired on a selected
Computational Fluid Dynamics (CFD) industrial unit to evaluate the model. The results provide useful insight on the regenerator performance
characteristics in terms of air distribution, coke burning rate and temperature profile in the regenerator.
The steady state flue gas composition and regenerator dense and dilute phase temperatures are well pre-
dicted by the CFD simulation. The CFD prediction of the bed density is underestimated compared to the
industrial data. The duration required to completely regenerate the catalyst is also estimated from the
results. The CFD coupled coke combustion kinetic model presented in this paper enables us to evaluate
the influence of the fluidized bed hydrodynamic on the catalyst regeneration in an industrial FCC regen-
erator. The developed model serves as a useful tool for the evaluation of future technology development
in the FCC regenerator.
Ó 2017 Elsevier Ltd. All rights reserved.
⇑ Corresponding author.
E-mail address: benjamin.amblard@ifpen.fr (B. Amblard).
http://dx.doi.org/10.1016/j.ces.2016.12.055
0009-2509/Ó 2017 Elsevier Ltd. All rights reserved.
732 B. Amblard et al. / Chemical Engineering Science 170 (2017) 731–742
Nomenclature
Fig. 1. Scheme of the FCC process. Fig. 2. Schematic diagram of a FCC alliance R2RTM Resid FCC unit.
B. Amblard et al. / Chemical Engineering Science 170 (2017) 731–742 733
are important to quantify for environmental requirements (Occelli, For the CO/CO2 ratio, most of the study showed that the main
2010). Therefore, the complete understanding of how the hydrody- influencing parameter is temperature (Weisz et al., 1966b).
namic characteristics of the regenerator catalyst bed affects the Errazu et al. (1979) proposed the following correlation:
coke combustion kinetics is very essential. 8
9:53 104 e RT
5585
CðsÞ þ 0:5O2 ! CO ð1Þ Different studies can be found in the literature on the modeling
CðsÞ þ O2 ! CO2 ð2Þ of FCC regenerators with the coupling of hydrodynamic and kinetic
models. In their approach, Lee et al. (1989) coupled a kinetic model
Two parameters are then important to characterize, the carbon
and a heat balance model with a two-phase flow one dimensional
combustion rate and the CO/CO2 ratio. Various kinetic equations
hydrodynamic model to simulate an industrial FCC regenerator. In
can be found in the literature for the carbon combustion rate, of
the hydrodynamic model, the fluidized bed is divided into a bubble
which some of them are shown in Table 1.
phase and an emulsion phase. The bubble phase is modeled as a
plug flow reactor (PFR) while the emulsion phase is modeled as a
Table 1 continuous stirred tank reactor (CSTR) with mass transfer occur-
Example of carbon combustion rate equations that can be found in the literature. ring between the two phases. They also included a jet grid model
to take into account the air distributor effect. The model predicted
r C ¼ 4 107 e157;000=RT C C (1) Weisz et al. (1966a)
more qualitative than quantitative results in term of temperature
rC ¼ 3 105 e109;621=RT C C P O2 (2) Hano et al. (1975)
and coke combustion rate. A similar approach was used by Filho
rC ¼ 2:788 e161;100=RT C C P O2 (3) Wang et al. (1986)
et al. (1996) to simulate the regenerator of an industrial unit oper-
734 B. Amblard et al. / Chemical Engineering Science 170 (2017) 731–742
ated by Petrobras. In their hydrodynamic model, they assumed a namic model to three dimensional CFD model coupled with kinetic
jet zone above the air injection where no reaction occurs. Good and energy models. The main advantage of the CFD modeling is
agreement was found between the experimental and predicted that three dimensional effects can be taken into account and the
regenerator temperatures. influence of the regenerator design (shape, internals, air injection)
Within the last twenty years, CFD tools became more popular can be investigated. The CFD studies presented in this literature
for modeling the hydrodynamic behavior of the fluidized beds. review considered a mean diameter for the particles while the
The main advantage is that geometrical and three-dimensional FCC catalyst has a particle size distribution going typically from
effects are better modeled compared to a one dimensional hydro- 5 lm to 200 lm. In our study, the CFD code used takes into account
dynamic model. However, CFD modeling at industrial scale the actual particle size distribution of the catalyst instead of a
remains challenging. Due to the limitation in computational mean diameter. Moreover, a kinetic model for the coke burning
resources, the mesh used to discretize the industrial geometry is was developed from in house experiments and implemented in
limited in size to obtain CFD solutions in a reasonable time frame. the code. Finally, for the evaluation of the CFD model, experimental
When using a computational mesh with large size, the modeling of data from a large scale industrial unit were acquired directly on
the drag force as well as the particle-particle interaction is chal- site over an entire day of operation.
lenging. Ozel et al. (2013) proposed a filtering method in order to
modify the drag force and particle-particle interaction models
3. Industrial data
when using a mesh with large cells size. To develop these filters,
these authors first solved a gas/particle flow with an Euler/Euler
This paper presents the CFD modeling of the 2nd stage regener-
approach using a mesh with a high number of cells (17 millions).
ator of an industrial R2RTM FCC unit designed by the FCC alliance.
Then, they carried out the simulation of the same configuration
The unit’s processing capacity is around 16,000 BPSD (106 m3/h)
using a coarser mesh (110,000 cells). They obtained different
of residue feedstock which is a rather small capacity for a FCC. This
results in the second simulation, the reason being that the mesh
section presents the regenerator configuration as well as the data
was too coarse and small scale hydrodynamic flow structure were
collected from the industrial site. Certain information on the
not well taken into account. In order to compensate for the fact
regenerator design such as air and catalyst distributors as well as
that these small scale flow structures are not resolved with the
cyclone designs are confidential and are not discussed in the paper.
coarse mesh, they developed a filter for the drag coefficient as well
as for the interparticle stress model to make correspond the results
3.1. Geometry and operating condition data
of the two simulations.
In their study, Moula et al. (2013) showed that implementing in
Fig. 3 shows the modeling domain which includes the combus-
a CFD model kinetic reactions based on macroscopic experimental
tion air ring distributor, lift line, catalyst distributor at the top of
results can lead to bad predictions since the connection between
the lift line and the external cyclones. The partially regenerated
these macroscopic measurements and local kinetics of the
catalyst from the 1st stage regenerator is transferred to the 2nd
heterogeneous reaction occurring at the gas-particle interface are
stage regenerator using air through a lift line. The catalyst circula-
not confirmed. They performed CFD simulation of FCC catalyst
tion between the 1st and 2nd stage regenerators is controlled by a
regeneration at different scale with the same kinetic model to show
plug valve as shown in Fig. 4. Combustion air is also injected in the
that kinetic modeling should include sub-grid models at larger
second regenerator through a ring distributor to keep the bed
scale simulations.
fluidized and burn the residual coke from the 1st stage. External
Chang et al. (2016) modeled with CFD the hydrodynamic of an
cyclones are used to recover the entrained catalyst. Finally, catalyst
industrial FCC regenerator using an Eulerian-Eulerian approach,
is sent to the reactor section through a connection pipe located on
where both gas and solid phases are considered as a continuum
the side of the regenerator.
phase. Equations for mass and momentum conservation are solved
Table 2 presents the key design features of the lift line and 2nd
for both phases, and the interaction between the phases is made
stage regenerator as well as the operating data needed for the
through the drag force; a mean diameter of 65 lm was considered
study.
for the particles of catalyst. In their work, Chang et al. (2016) eval-
The 2nd stage regenerator operates in full burn mode, wherein
uated several drag and particle-particle interactions models. They
the air is injected in excess compared to the amount required for
showed that hydrodynamic prediction is more sensitive to drag
total coke combustion. Therefore, as shown in Table 2, the carbon
than to particle-particle interactions. Besides, it is also shown that
monoxide (CO) concentration in the flue gas is zero with 8.6 mol%
the drag model with the clustering effect gives good prediction of
excess O2.
the regenerator axial bed density. In their work, Tang et al. (2015)
included a coke combustion kinetic model and an energy conserva-
3.2. Coke composition calculation
tion model in the CFD modeling of an industrial regenerator. They
used the Eulerian-Eulerian approach similar to the one used by
The coke composition on catalyst (carbon, nitrogen, hydrogen
Chang et al. (2016). A mean diameter representing the FCC particle
and sulfur contents) is required as it is an input of the kinetic
size distribution was used in this study. The kinetic model takes
model. Knowing the amount of air injected, the catalyst circulation
into account the carbon and hydrogen on coke combustion as well
and the flue gas composition, the averaged coke carbon and hydro-
as the CO oxidation. The temperature of the industrial regenerator
gen compositions can be estimated using a mass balance approach.
dense phase is well predicted. Concerning the combustion gases,
The coke analysis based on mass balance is shown in Table 3.
the CO2 concentration at the outlet of the regenerator is well pre-
Considering no information was available on NOx and SOx compo-
dicted while the CO concentration is over-predicted. This differ-
sitions for the 2nd stage regenerator flue gas, nitrogen and sulfur
ence comes, as claimed by the authors, from the fact that the
components on the coke cannot be estimated from a mass balance.
kinetic of the CO used in the model does not take into account
To obtain this information, two catalyst samples were taken at dif-
the CO combustion promoters that are added in the industrial unit
ferent locations on the FCC unit:
to promote the CO combustion in the dense phase.
One can conclude from the above literature review that the
The first sample was taken in the 1st stage regenerator. This
modeling of the coke burning in industrial regenerators evolved
sample is referred hereafter as ‘‘partially regenerated catalyst”.
within the last 30 years, starting from one dimensional hydrody-
B. Amblard et al. / Chemical Engineering Science 170 (2017) 731–742 735
External
Cyclones
External
Cyclones
Lift line
Fig. 3. Three dimensional view of the lift line and 2nd stage regenerator of the industrial R2R Resid FCC unit investigated in the present CFD simulation.
Table 2
Operating conditions.
Catalyst from 1st stage regenerator average dense phase temperature (°C) 730
2nd stage regenerator average dense phase temperature (°C) 766
System controlling the regenerator 1 2nd stage regenerator average dilute phase temperature (°C) 763
catalyst flowrate (up 2nd stage regenerator dilute phase pressure (bar abs) 2
Fig. 4. Plug valve system at the bottom of the lift line. Table 3
Coke composition analysis (ppm wt).
The results shown in Table 3 under the column ‘‘final catalyst com- Lagrangian approach. Collisions between particles are modeled
position”. The carbon content obtained from the catalyst samples through the use of a particle stress function. The advantage of
analysis and the one obtained from the mass balance on the indus- the MP-PIC method is that the coupling term between the gas
trial unit are close to each other with a relative difference of 2%. and solid phases takes into account a distribution of particles with
This result shows that the catalyst samples taken on the industrial different sizes and velocities while a classic Eulerian approach for
unit are representative of the regenerator operating conditions. the solid phase only takes into account an averaged particle diam-
For the coke composition input in the CFD simulation, the car- eter and an averaged solid velocity for the interphase coupling
bon and hydrogen contents from the mass balance calculation term. In the study presented in this paper, the particle–fluid drag
and the sulfur and nitrogen contents from the sample analysis force was expressed using the Gidaspow drag function
are used. (Gidaspow, 1994) which combines the Wen-Yu and Ergun models.
The turbulence of the gas phase is modeled through a Large Eddy
Simulation (LES) approach where the large scale motion due to
4. CFD model and methodology
the large flow structures are computed directly from the gas flow
equation while the small scale flow structures motion are captured
4.1. Kinetic modeling
through a subgrid scale model. BarracudaTM uses the LES Smagorin-
sky subgrid scale model (Smagorinsky, 1963). Concerning the
Table 4 presents the coke combustion reactions network
interactions with the wall, for the gas phase, a no slip boundary
implemented in the CFD code for the modeling of the 2nd stage
condition is applied while for the solid phase, the velocity vectors
regenerator. This reaction network has been developed at IFPEN.
of the particles after bouncing off a wall are computed through
Reaction rates expressions and constants are proprietary and are
normal and tangential momentum retention coefficients. In the
not discussed in this paper. However, the reactions presented in
current simulation, the default retention coefficients of the soft-
Section 2.1 are taken into consideration.
ware were used was 0.3 for the normal retention coefficient which
means that the particles keep 30% of their normal velocity after
4.2. CFD model bouncing and 0.99 for the tangential retention coefficient which
means that the particles keep 99% of their tangential velocity after
The CFD software used for this study is BarracudaTM, a software bouncing.
dedicated to model gas/particles flows. The gas/particles hydrody- The details for the energy equations and how reaction kinetics
namic modeling in BarracudaTM is based on the Multi-Phase Particle are implemented in Barracuda can be found in Snider et al.
in Cell method (MP-PIC). Details on the equations solved with this (2011). First, a transport equation is solved for each gas species
method can be found in Andrews and O’Rourke (1996) and Snider where mass transfer due to chemical reactions is taken into
(2001). The gas phase is treated as a continuum in a Eulerian account. The total fluid phase properties are calculated from the
framework solving the averaged Navier-Stokes equations. Particles mass fractions of the gas species composing the fluid mixture. A
are treated with a hybrid Eulerian-Lagrangian approach where cell-average chemistry calculation is used meaning that parcels
equations are derived from the Liouville equation. This equation properties (coke composition) are interpolated into the grid cells
governs the transport in an Eulerian framework of a particle distri- and the reaction rates are calculated in each grid cell. Each parcel
bution function f(x, u, m, t) where x is the spatial location, u and m can have a composition of ‘‘solid species” that can evolve depend-
are respectively the velocity and the mass of the particle and t is ing on the history of the parcel. The contribution of individual par-
the time. cels to the total rate of change of the solid specie is proportional to
The particle-phase equations are solved by discretizing the par- the volume of the parcel. In this study, we assumed that the diam-
ticle distribution function f(x, u, m, t) into computational parcels, eter of the particles is not affected by the ‘‘solid species” chemical
each of which represents a certain number of real particles of iden- reactions since the coke represents only 0.3 wt% of the FCC particle
tical size, velocity and position. For the resolution, computational as shown in Table 3. For a given gas mixture calculated from the
parcels properties are interpolated onto the Eulerian grid to solve reaction rates, the heat of formation and enthalpy curves of all
the solid-phase equations. Once the equations are solved on the gas species are used to calculate the new gas mixture enthalpy
grid, the Eulerian grid properties such as gas velocities, gas pres- and temperature. The energy balances of the gas and solid phases
sure gradients and solids stress gradients are interpolated back allow computation of particle temperature. The heat transfer with
to the parcel in order to update its position and velocity using a the wall is taken into account in the gas phase. For the solid phase
energy balance, it is assumed that the particle temperatures are
uniform within the particles and that there is no heat release due
Table 4
to chemical reactions within the particles. It is considered that
Set of reactions implemented in the present calculations.
the heat of combustion is released at the interface of the particles.
Heterogeneous Carbon CCoke þ O2 ¼ CO2 BarracudaTM uses a Cartesian hexahedral structured mesh. The
catalytic reactions combustion CCoke þ 12 O2 ¼ CO
calculation is transient and calculations are performed long
Hydrogen HCoke þ 14 O2 ¼ 12 H2 O
combustion
enough to make sure steady state conditions are reached. The code
Sulfur SCoke þ O2 ¼ SO2 is parallelized using GPU power. One calculation is launched on
combustion one GPU card.
HCN Hcoke þ Ccoke þ Ncoke ¼ HCN
formation
4.3. Simulation strategy
Homogeneous & CO CO þ 12 O2 ¼ CO2
catalytic gas phase oxidation
The regenerator modeling domain, as shown in Fig. 3, consists
reactions NO 2NO þ 2C ¼ N2 þ 2CO
reduction of a lift line section where lift air and partially regenerated catalyst
HCN HCN þ 1:75O2 ¼ NO þ CO2 þ 0:5H2 O from the 1st stage regenerator are introduced. The lift air transfers
oxidation the catalyst into the 2nd stage regenerator at the top of the lift line
CO assisted 2NO þ 2CO ¼ N2 þ 2CO2 through 12 lateral windows as shown in Fig. 6. In order to limit the
NO
number of mesh cells in the simulation, the lift-line section is mod-
reduction
eled separately as a sub-model and the CFD results of the lift line
B. Amblard et al. / Chemical Engineering Science 170 (2017) 731–742 737
simulation are used as input for the regenerator model. Indeed, if Table 5
the lift and regenerator were modeled together in one simulation, Lift simulation parameters.
the lift wall thickness would have to be meshed. Considering that Cells number 300,000
BarracudaTM uses a Cartesian hexahedral mesh, meshing the lift Average cell size 3.2 cm
wall thickness would lead to a mesh of 8 million cells which will Drag force model Wen-Yu/Ergun
require a very long computational time to complete. Input data (from Catalyst circulation rate: 150 kg/s
industrial Reg 1 catalyst temperature: 730 °C
operating data) Lift top pressure: 235 kPa
4.3.1. Lift line simulation Blower air temperature: 150 °C
Lift line air flow rate: 13.6 t/h
The plug valve at the bottom of the lift line shown in Fig. 4 reg-
Coke composition See Table 3
ulates the catalyst flowrate from the first regenerator to the lift
Catalyst density 1500 kg/m3
line. The boundary conditions used for the bottom of the lift line
Catalyst cumulative particle size distribution
are presented in Fig. 5. A homogeneous flow boundary condition Particle size (lm) Cumulative weight (wt%)
for the air injection is used at the bottom of the lift, and the catalyst 20 1
is injected on four lateral boundary conditions to mimic the plug 40 12
valve operation as shown in Fig. 4. A pressure boundary condition 65 50
80 70
is set at the top of the lift line, the pressure value imposed being 110 90
obtained from the industrial data. 160 100
Table 5 presents the lift line simulation inputs and initialization Model initialization Temperature 730 °C
parameters. Pressure 235 kPa
Gas composition Air
5. Results
Pressure outlet
connected to the
cyclone returns
Catalyst withdrawal
Fig. 8. Catalyst mass flowrate at outlet of the lift line (kg/s) versus time (s).
Cyclone
return
Cyclone
Air injections from return the lift line from the first stage regenerator is burnt in the lift line
fluidization ring which indicates that it is indeed important to take it into account.
(blue) The values presented in Table 7 were then used as inputs for the
2nd stage regenerator simulation.
Catalyst and gas
injection through the
lift termination 5.2. Regenerator simulation
device
The regenerator simulation was computed for 170 s of physical
Fig. 7. Regenerator boundary conditions.
time to ensure steady state has been achieved. The simulation can
be considered at steady state from a hydrodynamic and kinetic
point of view after 50 s of computational time, when the flue gas
Table 6
composition and the catalyst entrainment at the top outlet
Regenerator simulation parameters.
remained constant as shown in Fig. 10. It should be also pointed
Cells number 1,000,000 out that the mass of catalyst withdrawn from the regenerator is
Average cell size 8 cm
equal to the catalyst flowrate injected in the simulation. After
Drag force model Wen-Yu/Ergun
50 s, the flue gas composition, catalyst entrainment and the regen-
Input data Catalyst circulation rate: 150 kg/s
erator inventory remains constant; the simulation can therefore be
Catalyst and gas temperature from lift simulation
from lift: considered at steady state. However, the term ‘‘steady” should be
Gas flowrate from lift: from lift simulation taken with caution, since one can see that for example the entrain-
Regenerator top pressure: 200 kPa ment is not entirely steady and fluctuates around an averaged
Blower air temperature: 150 °C
value.
Ring air flow rate: 21.5 t/hr
Coke composition from lift: from lift simulation
Table 8 presents the comparison between the plant data and the
Catalyst density 1500 kg/m3 CFD simulation for the flue gas composition at the outlet of the
Catalyst particle size distribution regenerator.
See Table 5 Concerning the flue gas composition, the plant and simulation
Initialization Model initialized with average plant data data match really well with a good prediction of the CO, H2O and
Dense bed temperature 745 °C CO2 contents, the excess of O2 obtained in the simulation is slightly
Gas composition Air higher. The simulation predicts that the SO2 and NO molecules rep-
Bed height 6.5 m resent 0.17 mol% of the flue gas composition. This predicted NOx
Bed density 600 kg/m3
and SOx results cannot be compared with industrial data since
NOx and SOx composition in the flue gas was not available for
injected at the bottom equals the one escaping at the top of the the 2nd stage regenerator. Therefore, quantitative results about
simulation. the SO2 and NO flue gas contents should be taken with caution
It can be observed from Fig. 9(a) that the dense phase flow at in this case. However, it is interesting to use this CFD based kinetic
the bottom of the lift transitions to dilute flow as the catalyst is model to investigate the influence of regenerator hydrodynamic,
accelerated towards the top. Fig. 9(b) shows that the temperature operating conditions and hardware changes on the generation of
in the lift increases with height. This is due to the fact that coke SOx and NOx molecules.
combustion is taking place as shown in Fig. 9(c) –(e) where oxygen The comparison in Table 8 shows that full combustion of the
is consumed to form CO and CO2. carbon and hydrogen on coke is predicted by the model. Indeed,
Table 7 presents the averaged gas properties and the averaged the carbon and hydrogen contents in the coke used as modeling
coke composition on catalyst at the riser outlet. inputs are obtained from a mass balance on the industrial unit.
The CFD predicts a lift line outlet temperature 15 °C higher Thus, these modeling inputs correspond to the amount of carbon
compared to the 1st stage regenerator dense bed temperature. and hydrogen on coke burnt in the industrial regenerator. Consid-
Unfortunately, no industrial data were available to confirm this ering the kinetic network implemented as per Table 4, when all the
value. When comparing the initial coke composition with the coke carbon and hydrogen on coke is consumed by the combustion, the
composition at the outlet of the lift, about 30% of the coke entering flue gas composition predicted will be equal to the one of the
B. Amblard et al. / Chemical Engineering Science 170 (2017) 731–742 739
Fig. 9. Lift line simulation results, (a) Instantaneous solid volume fraction, (b) averaged fluid temperature (K), (c) averaged oxygen concentration (mole%), (d) averaged CO2
concentration (mole%), and (e) averaged CO concentration (mole%).
Table 7
Average gas properties and coke composition at the lift outlet. industrial unit if all the carbon on coke forms CO2 molecules (and
Temperature at lift Average gas composition at the lift line outlet (mol%) not CO molecules) which is the case in the model.
line outlet The time required to fully regenerate the catalyst is also esti-
CO CO2 H2O N2 NO O2 SO2
mated from the model. For this purpose, a group of particle clusters
745 °C 3.6% 7.2% 5.8% 74.8% 0.0014% 8.6% 0.031%
injected at the top of the lift line have been isolated and their coke
Coke composition at the lift outlet (ppmwt) content was tracked versus the simulation time. This group of par-
C H N S ticle represents 5 wt% of the entire regenerator inventory. The
1790 98 55 12 result is shown in Fig. 11, where the carbon content on catalyst
is shown versus the computational time.
Fig. 10. (a) Flue Gas composition (mol%) versus time (s). (b) Catalyst entrainment (kg/m2/s) at the top of the regenerator versus time (s).
740 B. Amblard et al. / Chemical Engineering Science 170 (2017) 731–742
6. Discussion
Fig. 12. (a) Averaged O2 concentration (mole%) (b) Averaged CO2 concentration (mole%).
Fig. 13. (a) Average solid volume fraction (), (b) Average temperature profile (K).
742 B. Amblard et al. / Chemical Engineering Science 170 (2017) 731–742
It is always difficult to validate completely CFD modeling against Dimitriadis, V.D., Vasalos, I.A., 1992. Evaluation and kinetics of commercially
available additives for sulfur oxide (SOx) control in fluid catalytic cracking
industrial data where only macroscopic daily averaged data are
units. Ind. Eng. Chem. Res. 31 (12), 2741–2748. http://dx.doi.org/10.1021/
available and were many phenomena are occurring (hydrodynamic, ie00012a017.
kinetic, heat transfer). Some validation data (catalyst entrainment, Doolin, P.K., Hoffman, J.F., Mitchell, M.M., 1991. Role of metal contaminants in the
local gas and solid holdups, precise temperatures profile) are not production of carbon dioxide during the regeneration of cracking catalysts.
Appl. Catal. 71 (2), 233–246. http://dx.doi.org/10.1016/0166-9834(91)85082-7.
available to assess precisely the modeling at industrial scale. How- Dryer, F.L., Glassman, I., 1973. High-temperature oxidation of CO and CH4. Symp.
ever, the evaluation of CFD tools at industrial scale brings an interest (Int.) Combust. 14 (1), 987–1003. http://dx.doi.org/10.1016/S0082-0784(73)
since it shows that macroscopic data can be predicted and since it 80090-6.
Errazu, A.F. et al., 1979. A fluidized bed catalytic cracking regenerator model. Can. J.
also shows the improvement needed for the CFD tool development. Chem. Eng. 57 (2), 191–197. http://dx.doi.org/10.1002/cjce.5450570210.
Filho, R., Lona Batista, L., Fusco, M., 1996. A fast fluidized bed reactor for industrial
FCC regenerator. Chem. Eng. Sci. 51 (10), 1807–1816. http://dx.doi.org/10.1016/
7. Conclusions 0009-2509(96)00039-5.
Gauthier, T., 2009. Current R&D challenges for fluidized bed processes in the
refining industry. Int. J. Chem. Reactor Eng. 7 (1). http://dx.doi.org/10.2202/
In this paper, we presented a study on the coupling of the
1542-6580.1857.
BarracudaTM CFD software with a coke combustion kinetic network Gauthier, T., Bayle, J., Leroy, P., 2000. FCC: Fluidization Phenomena and
developed at IFPEN to simulate an industrial FCC regenerator. Data Technologies. Oil Gas Sci. Technol. – Rev. IFP 55 (2), 187–207.
were collected from an industrial regenerator including coked Gidaspow, D. (Ed.), 1994. Multiphase Flow and Fluidization. Continuum and Kinetic
Theory. Academic Press.
catalyst samples, which were then analyzed at IFPEN with specific Hano, T. et al., 1975. The burning rate of coke deposited on zeolite catalyst. J. Chem.
methods to get the carbon, hydrogen, nitrogen and sulfur (C, H, N, Eng. Jpn. 8 (2), 127–130.
S) contents in the coke. The kinetic network equations were then Lee et al., 1989. Fluidized-bed catalyst cracking regenerator modelling and analysis.
Chem. Eng. J. 40, 71–82.
implemented in the CFD code BarracudaTM. Finally, the modeling Letzsch, W., Mauleon, J.-L., Long, S., Total Petroleum Inc., 1983. Advances in Fluid
input data such as coke composition, air flowrates, catalyst circula- Catalytic Cracking. Symposium on Advances in Catalytic Cracking Presented
tion, temperature, pressure were taken from the industrial data Before the Division of Petroleum Chemistry, American Society Washington D.C.
Meeting, August 28–September 2.
and used as inputs for the model. The results of the simulation Moula, G., Nastoll, W., Simonin, O., Andreux, R., 2013. Multiscale study of reactive
were then compared with industrial data. A good agreement was dense fluidized bed for FCC regenerator. Oil Gas Sci. Technol. – Rev. IFP Energies
found between the industrial and the predicted flue gas composi- nouvelles 68 (6), 1073–1092. 10.2516/ogst/2013183.
Murphy, James R., 1992. Evolutionary design changes mark FCC process. Oil Gas J.
tion and temperature profile. The bed density predicted was lower (May), 49–58 Special issue.
than the industrial data resulting in a higher bed level prediction. Occelli, M.L., 2010. Advances in Fluid Catalytic Cracking: Testing, Characterization,
Useful insights were obtained from the simulation such as the oxy- and Environmental Regulations. Chemical Industries Series, vol. 129. CRC Press.
Ozel, A., Fede, P., Simonin, O., 2013. Development of filtered Euler-Euler two-phase
gen content, temperature and solid holdup profiles. The duration
model for circulating fluidised bed: high resolution simulation, formulation and
required to regenerate the catalyst, was also estimated from the a priori analyses. Int. J. Multiph. Flow 55, 43–63. http://dx.doi.org/10.1016/j.
simulation. The modeling method presented in this paper enables ijmultiphaseflow.2013.04.002.
to evaluate the influence of the fluidized bed hydrodynamic on the Ranade, V.V. (Ed.), 2002. Computational Flow Modeling for Chemical Reactor
Engineering. Academic Press, San Diego (Calif.), London, Tokyo.
kinetic of the coke burning in an industrial regenerator. CFD mod- Raynal, L., Augier, F., Bazer-Bachi, F., Haroun, Y., Pereira da Fonte, C., 2016. CFD
eling remains a powerful tool with which different geometrical applied to process development in the oil and gas industry – a review. Oil Gas
configurations and different operating conditions can be modeled Sci. Technol. – Rev. IFP Energies nouvelles 71 (3), 42. http://dx.doi.org/10.2516/
ogst/2015019.
and compared relatively to each other for trouble shooting or tech- Sadeghbeigi, R., 2011. Fluid Catalytic Cracking Handbook: An Expert Guide to the
nology development. Practical Operation, Design, and Optimization of FCC Units. Elsevier,
Butterworth-Heinemann, Amsterdam, Boston, Heidelberg.
Smagorinsky, J., 1963. General circulation experiments with the primitive
Acknowledgment equations. Mon. Weather Rev. 91 (3), 99–164. http://dx.doi.org/10.1175/1520-
0493(1963)091<0099:GCEWTP>2.3.CO;2.
Snider, D.M., 2001. An incompressible three-dimensional multiphase particle-in-
This work has been performed within the R&D program of the cell model for dense particle flows. J. Comput. Phys. 170 (2), 523–549. http://dx.
FCC Alliance without which it could not have been possible to both doi.org/10.1006/jcph.2001.6747.
get industrial results and perform high level CFD calculations. All Snider, D.M., Clark, S.M., O’Rourke, P.J., 2011. Eulerian-Lagrangian method for three-
dimensional thermal reacting flow with application to coal gasifiers. Chem. Eng.
FCC Alliance members who have made this work possible are
Sci. 66 (6), 1285–1295. http://dx.doi.org/10.1016/j.ces.2010.12.042.
gratefully acknowledged. Stevenson, S.A., Socha, R.F., Mathias, M.F., 2005. Modeling of NOx emissions from
the laboratory regeneration of spent fluid catalytic cracking catalyst. Ind. Eng.
Chem. Res. 44 (9), 2966–2974. http://dx.doi.org/10.1021/ie048898e.
References Tang, G. et al., 2015. Numerical simulation of industrial fluid catalytic cracking
regenerator and riser. J. Therm. Sci. Eng. Appl. 7 (June), 0210012-1–0210012-10.
Andrews, M.J., O’Rourke, P.J., 1996. The multiphase particle-in-cell (MP-PIC) method Tone, S. et al., 1972. Kinetics of oxidation of coke on silica-alumina catalysts. Bull.
for dense particulate flows. Int. J. Multiph. Flow 22 (2), 379–402. http://dx.doi. Jpn. Petrol. Inst. 14 (1), 76–82.
org/10.1016/0301-9322(95)00072-0. Wang, G., Lin, S., Mo, W., Peng, C., Yang, G., 1986. Kinetics of combustion of carbon
Avidan, A.A., Shinnar, R., 1990. Development of catalytic cracking technology. A and hydrogen in carbonaceous deposits on zeolite-type cracking catalysts. Ind.
lesson in chemical reactor design. Ind. Eng. Chem. Res. 29 (6), 931–942. http:// Eng. Chem. Proc. Des. Dev. 25 (3), 626–630. http://dx.doi.org/10.1021/
dx.doi.org/10.1021/ie00102a001. i200034a005.
Babich, I.V., Seshan, K., Lefferts, L., 2005. Nature of nitrogen specie in coke and their Weisz, P. et al., 1966a. Combustion of carbonaceous deposits within porous catalyst
role in NOx formation during FCC catalyst regeneration. Appl. Catal. B 59 (3–4), particles II. Intrinsic burning rate. J. Catal. 6 (2), 227–236. http://dx.doi.org/
205–211. http://dx.doi.org/10.1016/j.apcatb.2005.02.008. 10.1016/0021-9517(66)90053-4.
Chang, J., Zhao, J., Zhang, K., Gao, J., 2016. Hydrodynamic modeling of an industrial Weisz, P. et al., 1966b. Combustion of carbonaceous deposits within porous catalyst
turbulent fluidized bed reactor with FCC particles. Powder Technol. http://dx. particles III. The CO2/CO product ratio. J. Catal. 6 (3), 425–430. http://dx.doi.org/
doi.org/10.1016/j.powtec.2016.04.048. 10.1016/0021-9517(66)90168-0.