Professional Documents
Culture Documents
Harmon Doors PDF
Harmon Doors PDF
The colours and surface finishes shown are subject to the limitations
of the printing process and cannot be regarded as binding.
3
Hörmann fire protection
Because it’s good to be on the safe side
Applications Features
These doors can be used in high-rise buildings, metro • Available in galvanised or stainless steel
railway stations, telecom centers, power plants, cellular • UL labeled doors for 45, 60, 90, 120, 180 minutes
network stations, garment processing units, shopping • Clear vision lite for up to 120 minutes’ fire rating
malls, industrial plants, multiplexes, hotels, auditoriums, • No welding joints and sharp edges, interlocking at
software parks, restaurants, etc. Hörmann doors and the stiles
frames are designed to perform and in the most demanding • Factory prepped to receive all types of hardware
environment. • High aesthetics and robust structure
• Fully flush constructions
• Easy to install on a flush wall opening & dry wall
Warranties partitions
• Factory finished for primer and paint finishes.
All our products carry YEAR
a warranty of 1 year WARRANTY
4 ✘
Hollow metal swinging Fire Door selection guide
At Hörmann, we are equipped to offer Fire Doors tested and certified to
American and British Standards. The significant requirements of each of these
standards are listed below.
American British
NFPA 80-1999, NFPA 252-1995, Part 2, BS 476, Parts 20 & 22.
UL 10B, UL 10C, UBC 7-2 and IBC 2000. Building Regulations 2000-Fire Safety-
Part B.
• A fire door must have a label attached indicating • Labeling is not obligatory but recommended.
the fire test rating.
• According to BS, a fire door can be tested
• Doors are rated for 3/4 of the rating of the without having leaf of an active latch bolt but with
surrounding wall. only a self-closing device.
• Every fire door must have a labeled self-latching • A fire door MUST be self-closing. Only the active
device to engage the strike. Dead bolts may not door leaf of an access panel (service ducts) or
be used in place of latch bolts. cupboards, can however be installed without a
closer but with a dead lock and a “Fire Door,
• A fire door MUST be self-closing. Keep Shut” sign placed clear on the door face.
• Steel ball bearing hinges must be used. Brass, • Unless shown to be satisfactory when tested as
bronze or other bases cannot be used. Plain part of a fire door assembly, the components of
bearing hinges cannot be used as well. any hinge on which the door is hung should be
fire rated.
• If a fire door is held open, it must be equipped
with a listed / tested, heat responsive or • If a fire door is held open, it must be equipped
electromagnetic device, fusible link or a smoke with a tested, automatic release mechanism
detection device. actuated by an automatic fire detection and
alarm system, fusible link (not if door is fitted in
• Only listed / tested fire door hardware shall be an opening provided as means of escape), or a
used. door-closed delay device.
• A fire door with glass opening must be provided • Two fire doors may be fitted in the same opening
with a listed / tested glass, a steel frame and so that the total fire resistance is the sum of their
glazing bead. individual fire resistances.
• Every assembly configuration such as transom • Signs and other items of hardware containing
panel, louver, vision panel, frame material, plastic should not be fitted on the non-fire side of
thickness of metal, leaf construction, core type, the metal door or frame.
door set type (single, double or double egress),
etc., must be covered by the test certificate or
global assessment report issued by the testing
agency.
5
Fire doors
Single and double-leaf
6
Door Leaf
Stainless Steel
16 gauge 18 gauge
Polyurethane Foam
Min. door opening width 357 mm (1’ 2”) 714 mm (2’ 4”)
Max. door opening width 1219 mm (4’ 0”) 2438 mm (8’ 0”)
Max. door opening height 3048 mm (10’ 0”) 3048 mm (10’ 0”)
Max. door opening width 1219 mm (4’ 0”) 2404 mm (7’ 11”)
Max. door opening height 2743 mm (9’ 0”) 2445 mm (8’ 0”)
Note: The sizes mentioned above are for the door leaf and do not include the frame.
Door Frames
Stainless Steel
14 gauge 16 gauge
* Other sizes are available. Max depth for Labelled doors can be 350 mm.
Note: For actual frame opening size please see the door data sheet for both labelled
and BS doors.
Optional extras see page 10-11
7
Door Leaf
Infill
Polyurethane Foam
Is used as an insulator and provides complete surface support, impact
resistance and exceptional thermal resistance. It offers the lowest “U” value
(approx. 0.09) and the highest “R” factor (approx. 11.1). This core has certain
limitations on application and fire rating of the doors. Not recommended for use
on BS fire doors.
Vision lite
Door leaf can be provided with vision lite for visibility.
Louvers
Labeled doors can be provided with optional louvers with fusible
link for a maximum size of 24” x 24” in 1½ hrs. rated doors.
Not applicable on BS doors.
8
Door Leaf
Finishes
Painted Finishes
All our steel doors are factory finished and
etched primed to take any paint. We offer a
wide range of semi gloss paint finishes.
9
Door Frame
Standard Design
Features
• Available in galvanised and
stainless steel
• Frames available in single and
double rebate
• All frames are prepared for 38.0 19.0 38.0 19.0
receiving hardware
16.0
16.0
39.5
39.5
• Frames can also be designed 57.0 57.0 70.0 70.0
for flush fixing
16.0
16.0
49.5
50.5
49.5
143.0
54.0
143.0
54.0
100.0
100.0
100.0
100.0
Optional
• Frames with Architave
49.5
49.5
16.049.5
49.5
49.5
49.5
• KERF frames with inbuilt seals
16.0
16.0
16.0
16.0
16.0
38.0 19.0 38.0 19.0 51.0 19.051.0 19.0
BS BS UL UL UL / BS UL / BS
Hardware preparation
Hinge Jamb
5.0 mm thick steel hinge reinforcement door
and frame for receiving the hinge.
Strike Jamb
3 mm thick steel lock strike reinforcement with
tapped holes welded to the frames.
Mortar Guard
1.2 mm thick steel plaster guard or mortar
guard is provided at the back of all hardware
cutouts in the frame.
Hinge Jamb Strike Jamb Strike-Mortar Guard Hinge-Mortar Guard
Mitered Joint (Double rebate) Bolted Joint (Double rebate) Welded Joint (Double rebate)
10
Door Frame
Options
Tee-Anchoring
First fix provides maximum engagement into
the constructed wall, with slip-on anchors
made out of galvanised steel.
Double rebate - T - Anchor
Expansion Anchors
Used in masonry openings or finished plastered
openings. The frames are bolted to the clear
opening with 8 mm expansion anchors. Screws
are rested on the backplate.
Bolted Anchors
Frames fixed on ‚C‘ Channel are bolted
directly on to the back plate.
Frames installed with steel stud Frames installed with wood stud Frames installed on ‘C’ chennel
11
Fire-Doors
Data sheets for UL Labeled / Fire rated Doors and Frames
Hörmann offers UL labeled doors as per the American standards NFPA 80-1999, NFPA 252-1995, UL 10B, UL10C and UBC 7-2.
Doors are tested under three categories covering temperature rise doors, nontemperature rise doors and steel stiffened doors.
Doors Frames
• Swinging doors are tested for a maximum of 3 hrs. for • Frames are tested for use as a component in fire door
hollow metal type and 1½ hrs. for composite metal doors, assemblies that meet the requirements of UL10C,
both single and pairs with astragal UBC 7-2 (1997) Part I (positive pressure) and UBC 7-2
(1997) Part II (air leakage / smoke, "S")
• 3 hrs. rating for non-temperature rise
• Door frames for use as a component in fire door assemblies
• 1½ hrs. for 232°C temperature rise (30 minutes) for hollow that meet the requirements of UL10B (neutral pressure)
metal type and 1½ hrs
• Three-sided steel frame with or without transoms,
single swing and pairs, of welded or knockdown / welded
construction
Non-temperature Temperature
Rise Doors Rise Doors
Infill Honey Comb Core / Polyurethane / Steel-Stiffened Special Core
Label A B C D E T
Rating 3 hours 2 hours 1 1/ 2 hours 1 hour 3/4 hour 1 1/ 2 hours
Max. Glass 100 sq.in.
100 sq.in. 100 sq.in. 1296 sq. in.** 100 sq. in.
Area — (0.06 sq.m.)
(0.06 sq.m.) (0.06 sq.m.) (0.84 sq. m.) (0.06 sq. m.)
per door
**1296 sq. in perlite. Not to exceed 54” w or h.
UL Label rating
Non-temperature Temperature
Rise Doors Rise Doors
Doors Door opening 3 hours 2 hours 1 1/ 2 1 hour 3/4 hour 1 1/2 hours
Max. size hours
Honey Comb core
1,2 mm, 1,6 mm Single Leaf 1219 x 2438 mm
G 18, G 16 (4’ 0” x 8’ 0”)
A B C D E
Double Leaf 2438 x 2438 mm
(8’ 0” x 8’ 0”)
Polyurethane
1,2 mm, 1,6 mm Single Leaf 1219 x 2438 mm
G 18, G 16 (4’ 0” x 8’ 0”)
C D E
Double Leaf 2438 x 2438 mm
(8’ 0” x 8’ 0”)
Steel Stiffened Doors / Special core
1,2 mm, 1,6 mm Single Leaf 1219 x 2743 mm
G 18, G 16 (4’ 0” x 9’ 0”)
A B C D E T
Double Leaf 2404 x 2445 mm
(7’ 11” x 8’ 0”)
1,2 mm, 1,6 mm Single Leaf 1219 x 3048 mm
G 18, G 16 (4’ 0” x 10’ 0”)
A B C D E
Double Leaf 2438 x 3048 mm
(8’ 0” x 10’ 0”)
Lead Line Doors
1,2 mm, 1,6 mm Single Leaf 1219 x 3048 mm
G 18, G 16 (4’ 0” x 10’ 0”)
A B C D E
Double Leaf 2438 x 3048 mm
(8’ 0” x 10’ 0”)
12
Frame Type Door Size Frame Size
Max. Max. Jamb Max. Max. Overall
Type
Door Size Rating Depth Panel Size Size
Three sided frames
Masonry Fixing
1219 x 3048 mm 3 h, Min. 1311 x 3055 mm
(4’ 0” x 10’ 0”) 2 h, 75 mm (3”) (4’ 4” x 10’ 2”)
1½ h,
Double Leaf: 1 h, Max. Double Leaf:
2438 x 3048 mm 3/4 h 350 mm (14”) 2536 x 3055 mm
(8’ 0” x 10’ 0”) (8’ 4” x 10’ 2”)
Min.
Single Leaf:
Single Leaf: 120 mm (4”) Single Leaf:
Max Glass size
1219 x 3048 mm 3/4 h 1311 x 3055 mm
shall not exceed
(4’ 0” x 10’ 0”) Max. (4’ 4” x 10’ 2”)
1296 sq. in.
350 mm (14”)
Single:
1016 x 1016 mm 3/4 h
(3’ 4” x 3’ 4”)
3 mm 3 mm
3 mm 3 mm
Net door width
Face Net door width Face
Face
trim Door opening width Face
trim
trim Door opening width trim
F.F.L.
F.F.L.
13
Fire-Doors
Data sheets for standard fire doors tested as PER BS 476
Fire rating
Max.
Door/Frame 60 min 120 min
Wall Opening
Flush Door with Honey Comb Infill material
Single Leaf 1,2 mm, 1,6 mm
1125 x 3000 mm ●
G 18, G 16
1,2 mm, 1,6 mm
1125 x 2800 mm ● ●
G 18, G 16
1,2 mm, 1,6 mm
1200 x 2500 mm ● ●
G 18, G 16
Double Leaf 0,8 mm, 1,2 mm
2150 x 3000 mm ●
G 18, G 16
1,2 mm, 1,6 mm
2150 x 2800 mm ● ●
G 18, G 16
1,2 mm, 1,6 mm
2400 x 2500 mm ● ●
G 18, G 16
Vision Lite Door with Honey Comb Infill material
Single Leaf 1,2 mm, 1,6 mm
1125 x 3000 mm ●
G 18, G 16
1,2 mm, 1,6 mm
1125 x 2800 mm ● ●
G 18, G 16
1,2 mm, 1,6 mm
1200 x 2500 mm ● ●
G 18, G 16
Double Leaf 0,8 mm, 1,2 mm
2150 x 3000 mm ●
G 18, G 16
1,2 mm, 1,6 mm
2150 x 2800 mm ● ●
G 18, G 16
1,2 mm, 1,6 mm
2400 x 2500 mm ● ●
G 18, G 16
Note: The sizes mentioned above are the maximum wall opening as tested.
14
Fire-Doors
Universal handing of Doors according to UAE reading conventions
Inside
Inside
Outside
Left Hand ( = DIN R )* Right Hand ( = DIN L )*
Outside
Left Hand ( = DIN R )* Right Hand ( = DIN L )*
Inside
Inside
Outside
Outside
Inside
Inside
Outside
Left Hand Active ( = Traffic Leaf DIN R )* Right Hand Active ( = Traffic Leaf DIN L )*
Outside
Left Hand Active ( = Traffic Leaf DIN R )* Right Hand Active ( = Traffic Leaf DIN L )*
Inside
Inside
Outside
Outside
Left Hand Active Reverse ( = Traffic Leaf DIN L )* Right Hand Reverse Active ( = Traffic Leaf DIN R )*
Left Hand Active Reverse ( = Traffic Leaf DIN L )* Right Hand Reverse Active ( = Traffic Leaf DIN R )*
* According to European reading conventions
15
Specification
for UL Labeled Doors
1. General
1.01 Scope 2.03 Construction of Doors
Specification covers the design, supply of materials, Doors to be press formed to 46 mm thick double skin hollow
manufacture and installation of factory made and approves door with lock seam joints at stile edges. Doors to have no
type of fire steel doors of 45 minutes’, 90 minutes’ and 180 visible screws or fasteners on either face. Doors should have
minutes’ fire rated labeled doors. Manufactured and installed an interlocking arrangement at the stile edges for flat
by Hörmann and tested to UL 10C standards, conforming to surface on either side. Internal reinforcement to be provided
NFPA 80 and ANSI A250.8. at top bottom and stile edges for desired fire rating. Doors
to be factory prepared with pre-punched cutouts and
2. Products reinforcements to receive ironmongery as per final finish
hardware schedule. Doors to have pre-drilled hinge plates.
2.01 Material and Finishes Doors with locks to have concealed lock box with lock fixing
A. Material - Frame to be manufactured from 1.60 mm brackets with pre-tapped holes. Doors with door closer
(16 gauge) galvanised steel sheets complying with the latest reinforcement pads to be provided at appropriate locations as
IS 277 Code of GPL Grade with Z 120 Coating or its Equivalent per manufacturer‘s design. Maximum size of the vision panel
British Standard. Fire door shutter to be manufactured from shall be 100 square inches per leaf and no dimension shall
1.25 mm (18 gauge) galvanised sheets. exceed 33 inches.
16
Specification
for standard fire doors tested as PER BS 476
1. General
1.01 Scope 2.03 Construction of Doors
Specification covers the design, supply of materials, Doors to be press formed to 46 mm thick double skin hollow
manufacture and installation of factory made and approves door with lock seam joints at stile edges. Doors to have no
type of fire steel doors of 60 minutes’, 120 minutes’ and visible screws or fasteners on either face. Doors should
240 minutes’ fire rating. Manufactured and installed by have an interlocking arrangement at the stile edges for flat
Hörmann and tested to Warrington under the Certifire surface on either side. Internal reinforcement to be provided
programme and BS 476. at top bottom and stile edges for desired fire rating. Doors
to be factory prepared with pre-punched cutouts and
2. Products reinforcements to receive ironmongery as per final finish
hardware schedule. Doors to have pre-drilled hinge plates.
2.01 Material and Finishes with hinge guard covers. Doors with locks to have concealed
A. Material - Frame to be manufactured from 1.60 mm lock box with lock fixing brackets with pre-tapped holes.
(16 gauge) galvanised steel sheets complying with the latest Doors with door closer reinforcement pads to be provided at
IS 277 Code of GPL Grade with Z 120 Coating or its Equivalent appropriate locations as per manufacturer‘s design.
British Standard. Fire door shutter to be manufactured from
1.25 mm (18 gauge) galvanised sheets. Optional Infill
a. Honey comb core: Doors shall be reinforced with honey
B. Finishes – Frames and Shutters to be suitably cleaned with comb core completely filling the inside of the doors and
solvents and etch primered for receiving primer and top coats. laminated to inside faces of both panels.
Shutters to be primered in zinc phosphate stoving primer b. Mineral wool core: High density mineral wool core should
(can withstand a minimum 250 hours of salt spray tests). be used as infill material for insulated doors.
17
Hörmann product range
Everything from a single source for your construction project
18
19
Hörmann: Quality without Compromise
Hörmann KG Amshausen, Germany Hörmann KG Antriebstechnik, Germany Hörmann KG Brandis, Germany Hörmann KG Brockhagen, Germany
Hörmann KG Dissen, Germany Hörmann KG Eckelhausen, Germany Hörmann KG Freisen, Germany Hörmann KG Ichtershausen, Germany
Hörmann KG Werne, Germany Hörmann Genk NV, Belgium Hörmann Alkmaar B.V., Netherlands Hörmann Legnica Sp. z o.o., Poland
Hörmann Beijing, China Hörmann Tianjin, China Hörmann LLC, Montgomery IL, USA Hörmann Flexon, Leetsdale PA, USA
Hörmann is the only manufacturer worldwide that offers you a GARAGE DOORS
complete range of all major building products from one source. OPERATORS
We manufacture in highly-specialised factories using the latest
INDUSTRIAL DOORS
production technologies. The highly-specialised network of sales
LOADING EQUIPMENT
and service companies throughout Europe, and activities in the
www.hoermann.com
USA and China, make Hörmann your strong partner for first-class HINGED DOORS