DISPENSER MODULE TEST ON NCR ATM MACHINES By ProBlog 03.28 Post a comment Dispenser Module Test on NCR ATM Machines Test out of money: A. Test money from tapes and immediately reject (divert), how to do it as follows: 1. Enter the Replenish menu 2. Select Test Cash 3.1 sheet of money per tape will be issued & directly to the divert The second way, is as follows 4. Select menu 07) Diagnostics 2. Select 05) Consumer Confidence Test, select the device to be tested (dispenser) 3. On the control menu select Run Test 4, The money out of 4 sheets (each 1 sheet of tape) directly rejected to the divert B. Test the money from the tape and then transport it to the presenter, following methods: RELATED: The Cost Of Credit Cards 1. Use the NCR diagnostic diskette 2. Enter menu 07) Diagnostics - Select 02) Maintenance 3, Enter the Currency Dispenser menu 5. On the Control Menu, create a condition 08) Cash Enable = ON 6. Return to the Curenoy Dispenser menu, select the Set note sub menu, for example: each cassette is fillec with 5 sheets 7. Select the Dispense menu 8. Money will come out of the cassette to the presenter as many as 20 sheets (5 sheets x 4 tapes) 9. Select the Clear menu, the money will be dumped into the divert 10. Return togle stick position as before The NV-RAM Dispenser is as follows: 1. Change the Dip switch 1-3-8 (ON), Reset the engine 2. The loading up to the LEDs in the Dispenser Board is stable (blinking duty cyle 50%) 3. Return the Dip switch to its original position 4, Reset the machine again, do CSOH 20 and CSOH 21 For the replacement of the Module feed, consider the following matters + From 4 Feed Modules to 2 Feed Modules, you need NV-RAM + From 2 Feed Modules to 4 Feed Modules, there is no need for NV-RAM Remember: If we NV-RAM Dispenser then Bill Config and Singularity will change, so we configure again! To reset the Bill config parameter, the method is: 1. Enter menu 07) Diagnostics - select 01) Configure - select Configure Bill Config - select change 2. Fill in each tape with the parameters Bill Size and Singularity Wind Test: To find out whether / not good performance of selenoids and wind dispersion we can do a wind out test: 1. The tape was removed 2. The hose to the Pick Line was removed 3, Insert the Diagnostic disk 4, Select 07) Diagnostics, select 02) Maintenance 5. Select 01) Currency Dispenser, select More 6. Select Test Pick valve, select the cassette number Clear Dispenser, is done to clear the malfunction error when the machine fails the transaction or the machine is faulted, and at the same time Reinitialize the Dispenser, as follows: RELATED: Credit Cards With Cash Rebate 4. Select menu 07) Diagnostics - Use the Diagnostic Diskette 2. Select 02) Maintenance 3. Select Currency Dispenser 4, Select Clear Dispenser When we order the Clear Dispenser, no money should come out. If there is money coming out it means there is leak. Check the hose is / is not a leaky hose, do the wind test. If during the wind test there is no wind pull Solution: Change selenoida, check sensor U Timing disk / drive Cluster, replace Cassette Interface. View and print the M-Status (Error Log) of the NCR ATM Machine, as follows: 4. Insert the Diagnostic-NCR disk 2. Select 07) Diagnostics 3, Select 03) Level 3 Diagnostic 4, Change Print to Display, with the Fdkey key so that the Error Log can be printed 5, Select 01) Display Error Log 6, Select 04) Hardware 7. Press Print, the Error Log will be printed Delete / clear the Error Log, as follows: RELATED: Getting Your Credit Card Online 1. Insert the Diagnostic disk 2. Select 07) Diagnostics 3, Select 03) Level 3 Diagnostic 4, Select 04) Clear Error log 5, Select 05) Clear tally 6. Select 06) Clear Fitness Before we repair the machine or for reinstallation purposes, it helps us to print various parameters as follows: 1. Print Counter (from the Replenish menu) 2. Print Configure, How: Enter the menu 05) Configure, select 01) Print configure The way to print the communication parameters is as follows: * Select 07) Diagnostics * Select 01) Configure + Change Print to Display, with the Fdkey button, so the old settings can be printed * Select 01) Display Communication + Press Print, the old parameter settings will be printed (in Hexadecimal Format) + For TCP IP, after entering the Diagnostics menu - select Maintenance - select Extra Feature - select Display - then press Print For the Rs232 Communication Protocol (Sdlc, Sna, x25..etc) To Test the NCR Loop back of the Machine, the method is as follows: 1. For Protocol (SNA, SDLC, X25) 2. Select 07) Diagnostics 3, Select 02) Maintenance, then Select 09) More 4, Select 09) Comm - Board 1. Change Loop On to Loop Off 5, Select Loop 3 Special Test 6. Test up to 100 times ‘Turn off the Shutdown engine in the correct procedure as follows: 1. Enter menu 07) Diagnostics 2, Select 02) Maintenance 3, Select 9) More 4, Select 06) PC Disk 5, Select 05) Park Fixed Disk Thus hopefully useful RELATED: Getting A Higher Limit on Your Credit Card READ ALSO OTHER ARTICLES Overcoming Damage Pick NCR ATM Preventive Maintenance ATM NCR Dispenser Module Preventive Maintenance Card Reader ATM NCR Procedures

You might also like