ISO 9001 Certified CompanyPRODUCT INTRODUCTION :
As business become increasingly dependent on technology for their fundamental
operation, the need for system availability is of paramount importance.
The Powercom Vanguard series UPS is designed for those applications that need
maximum protection in the 700VA - 20KVA range. With its high-frequency, double-
conversion online topology, providing nonstop clean sine wave power, advanced
communications and space-saving tower design, the Powercom Vanguard series
is the ideal power solution for networks, web servers, telecommunications
applications and other critical electronic equipment.
In addition to its proven design, the Powercom Vanguard series offer Advanced
Battery Management (ABM) and sophisticated communications to provide
maximum system availability. ABM uses a three-stage charging technique that
not only doubles service life of battery but optimizes charging time.
The Powercom Vanguard series's communications are flexible, allowing for local,
network or remote monitoring and management. The Powercom Vanguard
includes the latest version of Powercom's UPSMON Software Suite, which
provides power monitoring and shutdown software.
With the Powercom Vanguard, Powercom delivers a best-in-class power solution
for maximum system availability, and peace of mind.
a ee
oe Ss
=4 =o
ze
=FUNCTION :
Application:
Workgroup Server, Departmental Server, Enterprise Server, WEB server, Workstation.
Problems:
Power Failures, Power sags, Power Surges, Under-voltage Electrical Line Noise, Over-Voltage,
Frequency Variation, Switching Transient, Harmonic Distortion.
Even when presented with the most severe of these power problems, the Powercom Vanguard
series output remains within a remarkable +/-2% of nominal voltage.
it means that your critical system always receives steady and clean power.
In addition, the Powercom Vanguard series transfer to backup mode with no break in power,
making it the perfect UPS for equipment in environment plagued by poor power.
SPECIAL FEATURES :
1. 15 LCD Display:
Easy viewing of UPS status from LCD panel including:
O/P Voltage O/P Load (%) Battery Charge (%)
|_O/P Frequency O/P Watt (W) ‘Temperature ('C)
UP Voltage O/P VA Battery Pack Number
UP Frequency OVP Currency (A) Rating (VA)
Battery Voltage Back Up Time (Min.) CPU Version
2. 14 UPS parameter settings:
OIP Voltage Set Manual Bypass Site Failure Set
UP Frequency Set Outlet Segment Set Language Selection
UP Bypass Set Battery Test Generator Option Set
Free Run Set Silence Mode Set RS232 Control
High Efficiency Mode Battery Cabinet Set
3. SNMP Control Card (option)
Optional slot is available for Network Management
Control Card to allow direct control and monitoring
capabilities in SNMP-based.
4. Extended Battery Pack (EBP) (option)
Optional extended battery pack connection allow
Vanguard to connect to extended batteries to provide
longer backup time for certain applications
ms on ) CO)
moe SO) &
owanreny
mm mss5. USB port (option)
Connecting the UPS to your computer is accomplished through the USB port on the back of your
computer, USB compliant hardware and operating system will be necessary including installation
of a UPS driver.
The serial port cannot be used when using the USB port. The USB cable is standard and can be
bought separately.
6. EPO port (emergency power off)
A customer-supplied switch located remotely can be used to open the EPO connection and
allows UPS output receptacles to be switched off.
Since the EPO shuts down the equipment immediately, orderly shutdown procedures are not
followed and not by any power management software.
The UPS will have to be manually restarted in order to regain power to the outlets.
Transient protector isolates your modem, fax machine, and other electronic equipment from
“back door" power surges.
7. Network Transient protector (700 - 3000 VA)
The network transient protector, located on the back panel, has both IN and OUT jacks, and
houses a single RU-45 (10BaseT) network connector.
Connect the input connector to the jack labeled IN, and the output connector to the jack labeled
our.
8. Load segments (700 - 3000 VA)
The power management software controls the sets of receptacles known as load segments which
provides organized shutdown and startup of the equipment. Less critical equipment can be
turned off during power outages saving battery power for critical loads.
The power management software manual has more details regarding this
VGD-700-1500VALCD _ VGD-2K-3K VALCD VGD-700-1500VALED VGD-2K-2K VA-LED
EeThe load group status can be viewed from the LCD display and can be changed if necessary.
These load segments are usually handled with the UPS management software.
Refer to chapter 5.2 regarding the two load segments that come with each model.
On
VGD-1K.2K.3K RM2U real panel
Unique Design
+ Vanguard rack mount models come in different heights such as 1U, 2U, or 3U to meet different
space demands.
+ Vanguard rack mount now is available from 700VA up to 10 KVA.
+ Vanguard 3U rack mount model is designed to be flexible and able to ft in different spaces.
+ The control panel can be adjust 90 around to
accommodate the UPS installation direction
(vertically or horizontally).
+ Remote tontrol panel feature is designed for —=—-—
easy control of the UPS which is placed in the EMM!) = =p-
unreachable area. 700~1KVA (1U)
EINK =="
1K~3KVA (2U)
6K~10KVA (3U+3U)1) Remote control panel feature:
The display panel can be remove from the front panel and attached to the back panel with a
cable in order to provide the wired-remote feature.
2) Display panel is designed to be easy removable.
3) 2 different direction of insertion slots are designed to attached with display panel providing 2
different angels to suit in different space demands.
4) The Vanguard 3U rack mount can also be tower
model after switching the display panel by turing
the front panel and put up the unit to vertical position.
—
remote control panel feature display panel can be 90°rotated
90*rotatable
—
display panel after rotation
can be used as tower model
VGD-4K.5K.6K .8K.10K RM panel
Software and Communications Options
* USB port (optional) allows UPS to communicate with Windows 98/ME, and XP computers
* RS232 Port (standard) for interface with power management software
* SNMP/Web card (optional) adds direct control and monitoring capabilities in SNMP-based
networks. Ability to monitor UPS status and meters through web browser interface.
* Relay card (optional) adds integration to industrial environment and building management
systems, shutdown for IBM AS/400.Powercom UPSMON Software
The industry's most comprehensive software bundle, the Powercom Software Suit, is free and
included with every Powercom Vanguard UPS.
Special features with Powercom UPSMON software:
+ Easy Installation: UPSMON plus Wizard guides you through software selection and installation
+ Support Windows NT Service and start UPS monitoring software before user log in under
Windows 95/98/2000/NT/ME/XP.
+ Automatic shutdown
+ User notification of power events
+ UPS power events log
+ Automatic reboot
+ Broadcast power abnormal status
+ Smart save file
+ Scheduled system shutdown/reboot
+ UPS Battery low warning
+ Real-Time graphical display
+ Battery level display
+ Power quality data log
+ Printing power events list
+ Graphic display by meter
While UPSMON connects to VGD unit, the UPS Setup ff] feature can manage all the
UPS related setups
=e
Enable Outlet Setup functions Enable Multi Outlet Control ‘Manage Outlets schedule
and auto shutdown
BesoVANGUARD TOWER
Specifications
[aww mal wi LGD aay) vero | ve 00
cumciry [Caps A an "9%
(cope V0 00 700
eur aoe ad 06110 601200 PV
Wee Rone | tod aon
‘carwur 1 ow 6, 20, PV m,n, zo, 200 WSs Vlas)
T
<9 aDAD at earns
|prorecnon ano {0 FEE C5249) /390 SECON Sw)
‘DPS eae otra orn ce eset ncon
‘vere Urs egeen) Inemattgeen
‘usar tase eseton banter)
warn i= et vais, pa aay,
str an ack pode ty cy
sap eve 5200
‘Senin beeing sai ordi day
‘even sim) | Bev vavrann | Savi tarzan | svat | vavitvrzan | rev/raveaa | iov/tavian | t0V7 tan
[isu meal ‘owe
Honora “oti ary ware po a
‘sce Proton {ator wa ang ay carer tn ry ow
[sept nw |r Tan Sin Fa Se ean om
[te etna | 1m rr 1S Sern ei ry ‘smi
eaveeN net bet Ewa 15 (at E20 a3 rere
Pct News 35 (104) C320 230%) vee
ertnans sao “a(t ieemocise
exci B00) sao ecm semocira
“owe Conese se 20 «2 200190 | 25718908570
lmnop WaOxH are 185205 aoearenzy ooranezzey
rr) oa a7 me 3 mo
[meee oe eae) ue, ss m2)
|Snepra west) 18 69 ws 360 sao ‘40
tom roe oy, we, en om, ae ex,
Sage Torpwoase “ai svi 4= 27
ae ot etn re
‘onreatice say ice
‘ove ase) ‘ee icons Fc ran 6. CPR
[egorerPreon roe pey my vr rene 0906
porVANGUARD TOWER
Specifications
[oem tc veo. vam ‘eer veowise | Vee
Jeane Cosy osm ‘on “cen ‘isco | oon cnn
orc 0H 0 "aan a ‘5008 “000
wr Stag 20 BH
vee ‘eos ans
1
a hs Soa
‘auRror ‘etn boe 1 oH BV RH a zs atv ae Ga a)
Frome one) S/coneiase
fomsest too ‘isonie 60R
‘a amy re A en
{swan err ote fy te rere ec
feeearcaraae SaiTHD ard
PROTESTORS sn roman eww 4S
rove Svein Psa {GE rs ae 10 eo)
130m toners wa ton fe Sarno
on rea aan Paco eto rei Re orm ric
vere Sl iy mo) selgeon encima memantine)
ORPUY WARE and By 0 mh I eee reer
a try ec) ee
‘a Fai xen bmp xr dy
maa 5:8 sir s
‘are "yee ee
Sa ny TT HVT | | evan | RS | HORT
masa ae ar oer ad air ge
9 tn iy set by or |
exit “es
ck tr Gonos ti Ft a
co venta adn
| acne Hass
rensoicies | Stree saree xeon ax eos
Tmcenyurarinceom orworversy | qavearzwmry __|qamrmcey | _amtaaearaney
Netiete @NOSOR | OD oar woe) 750,380)
ShesraWeera MOSER) m0 22) ‘orsana ‘sisena) fonout23)
“oer Binoreeten | 257x507 Bexemer8 exe a 608
coeanwrosnemon |iermesirey | (awsarramr) _(eamurmncm | (arcaearesee)
Naivetnain) nom | 1w0EMNH ‘no. “oom 0100)
‘Sora i 9 wR | TOG) ‘sr s.a83) mise) e860)
‘BirnciwaeiT [Spent oareiae= oe
‘some eyei Seo) 4- ner
tren aHiey
ior Tena ean
eowromionce say imc
ne ns 09 (Een Foc ran 6 GaP?
tet are
ein are ety mo a ers eeVANGUARD RACK MOUNT
Specifications
frmemmaioa emer | Waren | Veer | vez
Ema emo rm ‘won| won| so
[essen on 0 ‘cn ee
| te
= each a
‘inary ‘BVT a tn a 1 ae a
oo Teinanesiaey
<= ie
Serra =F
rs Ow mean San ee
verone seen Sioa
PRoTEGTENAD Sr Moc av EE Ga EEE il)
“Shot Crt Protection aa [UPS cabal culo neal oF put fuse / rc
ister nia Tests Naor
(sora komen ste roto bee
Ysa my Tele cp ts eno
‘oman isnot tipsy se ai
‘to peer See
(oom en
reas Ten era sa aco
larren —— r ed rere tn die
2 ey | aaa = =
eer sh | IiBurann | ST TIAN | TRAN | RUN | Tan 7
=a ia a
Frmiene er
Foeoer ee eT
Sy Pa Gao wea ry sort on bee lr
Gres pate fara [rca Ta tam Tam Tam
Dante te ore [vient [wars | em a ‘i a an
iat i oe a
et Nein 0 m0 a0)
Momeni a sc ioe
(uresaom soon om ‘oo Son
fermen nar c= asa ew)
Greenies | _tarrarsinw Goremonsras
unwsonm er airenr “is «ore
arenes ares on ames ety
awaaiere | weeaaion | wwrmamo. | wr we 36 Bieter)
Pecos Newaoaa_| mania | ae a 0, seociasxomey oa
Btn neara ws) | weirvonay | wero | a7 m7 “41 GP ae
eee Revie | ansaers) | ern oon “ 755,06 ba oa
sepa Twos = ewer
oa Sere
ronan san coins
[eMC (EMS Em) NEC 070004, FCC Pan 18, CISPR 22 =}
co fs
[sont a ‘oie ea oa
irSpecifications
frase noes {ee rena | eB aT
one ‘ zo
uF fete Lond =
‘ege eros [toate |
(racy iene aio eahy
jauinar a ein {io 1 Pw 5 va Scab aoe
freamyion eleaneciaoe
7 awn oS
‘ns Fy dota merce coed
‘Cama Forn —
FoTecHON Ae [Boge ensn “ov gS Gz (RESTON ASIow
waved mn ona Urs ote tere
bsrayy —|acomnen em aeons ny) ses
|rasemc Ont {ont et. to on.
[cco mone ce aminesn eh oen bt ep at
‘ster ‘Seen ee
(caro)
sre en gs LC de
oo eam Soro andU58
lonay Te Sos none ei on ee
oc wobaeammy | Bava | Sv aver [evar] Tarr veveant | too /sama | TaVTTRVAR | ENT A
Finer te Th
(veer ‘eh i rtp am es
ste Prose it el Sonny ny coer boy on -
[ct Upr rotng | Sm con ra Sn oem Ta ce
[nc ow tos) | 12 mn in soa coy fm an ‘Si
Pevsca ptt REASON 0 Pare
a et 15 (207 fe
Fos eee iecuociva si) weomocire rr
(revue Sem) reoacire tise, teow ci tom
mdr mre cosas “ann “areata no a8) ome se)
Imomcnmgaaymsorn | cewateretaneu —_|geevirrcaewy) (eeramesamay __ [~kastaiwauliemmy mas)
mem) +0 zo ne Eco
‘emaort en ee oan cot oa)
sone 96) 0 25 «so Eco
‘wreanoet om on ose (soto)
‘ounce rg wos Scie jore
‘Some onpmar perc iaF
(tne ram oetn
ttre art 3 nmin naan
rE ay ‘uimce
1 6) ie era rocron soba
[vat Pees
Cason an ‘say nan gn
eterVANGUARD 3 PHASE IN 1 PHASE OUT
‘Specifications
“ov mol (th LCD dt) or yeoiea! | vena! | veossrat | veoaai
[exencrn ‘oot A) =m won oan ‘aisova | tna 004 |
oma sano "eon ‘one ce “cro
[nour ‘itor ond ‘ev, nud bt SDE
Tad acy ‘tgs Rare Tocapeiy
_ [rosy aor ag
amar ‘orn en sr {i a8 a 2012, 2 12 Banc a Ve)
reco oboe) saveorash
So ‘icra BFS
“Een nese AGW A) Sem
Us omegr ey ‘ne Fy cin ono ooh
‘uo Sour
ramon oro