A reservoir model with dimensions of (5, 5, and 20) cells in (I, J and K) directions

respectively. Find the initial distribution of pressure and saturation for the model and
calculate the initial oil in place, other information
Top of reservoir model 2700 m.

The cell dimensions 500, 500 and 4 meters in directions I, J and K respectively.

Average porosity for the reservoir is 0.2.

Water saturation cut-off is 0.6.

Depth of OWC (equal to FWL) = 2766 m

Initial reservoir pressure = 3200 psi at 2740 m

Water and oil specific gravity are 1.11 and 0.87 respectively.

The capillary pressure table

Pc (psi) Sw
9 0.19
8 0.195
7 0.2
4.2 0.3
3 0.4
2.3 0.5
1.6 0.6
1.1 0.7
0.6 0.8
0.2 0.9
0 1