eiszerzees Asi se ure rea. we TES SIEMENS aerext| Westinghouse Siemens Weatinghouee Power Corporation GENERATOR STABILITY MODEL DATA Customer: CFE Unit(s}: Tuxpan CT Type: Alr-Cooled kv: 16.5 MVA: 196 PF: 0.9 Frequency (Hxj: 60 JAP: 3600 (SCR: 0.659 PSIG: WA jAmbiont: 34.8 © [Cooling Water: 48.7 ‘\Cold Gas: 51.7 C 1 = Synchronous (%) 1.4802 «1.6288 «= «Transient, open circuit. (Ta) 10.479 © Transient Oi} GIST 2.2084 + Sub-transient, open circun. —(Ta).0.048, = Suptransient (') 0.1338 0.1552 = Transient, L-N short-circuit, (Ty) 2.247 Quadrature axis + Subtransient, L-N short-circuit (Ta) 0.042 = Synchronous (XJ 1.4223. S64Gw Transient, CU shortcircut (Tax) 1.873 Transient «= (K)_--DBGAB_—«0.TED_—- © Subtransiont, LA short-cireuk (Ta) 0.04 © Suttransient (X'y 0.182 0.t53t Transient, S-phase shor-circut’ (Ts) 1.17 Armature leakage, (%) —0.1253-«««O.1819 =~ Sub transient, S-phase (a) 0.035 steady: state shortcircutt r Zero sequence (Kj + 0.080 0.0842 Gundrature ade Nogative sequence (X) 0.1229 0.7542 “Transient, operecincutt, mod 1164 Potier Reaciancs %) 0 — G.A758 + Sub-transient, open-cirouit, © (Ta) 0.088, + Transient, UN, short-circuit — (Ty) 0.354 Resistance and Capactance * Sub-transient, L-N, short-circult (Ta) 0.056 “Armmatere A © Transient, C-t, short-cut = Ta} 0.316 * Zero Seq. Res. (p.u.) (Pe) 2.00111 © Sub-vansient, LL snort-circut (Tq) 0.05 Positive Seq. es. (pus (i) 0017 «- Transiem, $phase short-ciroutt (Te) 0.245 © Negative Seq. Res. (pu) (Fx) «0.01425 e Subtransiont, 3 phase Ta 0.035 shortcircutt + OC Aes..perphase@ (Ra) 0.00072 78°C (a) + Capacitanes to ground {pFiphase) 0.427 OG component of SC eurrent Tas} 0.685 Flot DC component of L-N fault as) 0.594 * OCRes. @75'C(0} RF} 0.163 BC component of LL fault a) 0.685 Excitation/Field Data Inertia Constants ‘Generator feld volloge mt raed pI) 2207 Generatey and Exciter, WHF (IST) FASE Genarator field curentat rated pt(A} 1242.0 Generator and Exciter, H Constant 219 {KW-SecKVA) Field current required to putfiux across 497.6 air gap (A) Shont-ciroult Torque Data. Field current at no load (A) 554.4 Te (MVAIL-ptH{Ae*sin(at}Be“sin(2cx}+Co Exciter required rated power (kW) 390.0 TwAnd.165 oxan3,012 Exciter required rated vottage (V) 250.0 Saturation factor at 1.0.x rated kV(%) 11.4 TexBed 583 Bab=3.101 2 Saturation factor at 12 x rated kV (2%) 48.9 TyxC=0.753 yror2717 = 7 / BE + cat gh si CFE SUBDIRECCION DE GENERACION COMITE DE PROTECCIONES ‘Comisién Federal de Electcidad CALCULO DE AJUSTES DE PROTECCION DE GENERADOR DE ACUERDO A LA GUIA CFE-G0100-07 CENTRAL C.C.C. POZA RICA UNIDAD __4 GERENCIA ‘SURESTE, MARCA PRIMOMOTOR ‘SIEMENS WESTINGHOUSE SUBGCIA TTERWO SURESTE. MODELOISERIE PRIMOTOR T CENTRAL, POZARICA MARCA GENERADOR ‘SIEMENS WESTINGHOUSE UNIDAD 4 MODELOISERIE GENERADOR T_1s006 TIPO TURBOGAS CICLO COMB | MARCA EXCITACION CUTLER HAMNER NORMA CONSTRUCCION [_ANSIC60-14_] MODELOISERIE EXCITACION I DATOS DE LA MAQUINA: POTENCIA PRIMOMOTOR mw's POTENCIA GENERADOR va VOLTAJE NOMINAL VOLTS. (CORRIENTE NOMINAL |AMPERES FACTOR DE POTENCIA FP. ROTACION DE FASES RAZON DE CORTOCIRCUITO. Xd REACTANCIA SINCRONA EJE DIRECTO / CUADRATURA Xd REACTANCIA TRANSITORIA EJE DIRECTO / CUADRATURA Xcd REACTANCIA SUBTRANSITORIA EJE DIRECTO / CUADRATURA, REACTANCIA SECUENCIA NEGATIVA, pu lpu Jpu 0.5529 0132 0.1329 [pu REAGTANCIA SECUENCIA CERO 0.08 —|pu RESISTENCIA DE ARMADURA C0007 o.0007F 0.00072 —]OHMS / FASE A, B, C FRECUENCIA Hz |, VALOR DE CORRIENTE DE SEC. NEGATIVA PERMANENTE. % K VALOR DE CORRIENTE DE SEC. NEGATIVA PARA DASIO Pa ]SEGUNDOS VELOCIDAD 3600__|RPM POLOS [—LISOS__|No. DE POLOS TIPO Y CLASE DE AISLAMIENTO DEL ESTATOR F w]e TIPO Y CLASE DE AISLAMIENTO DEL ROTOR F 30 fc ‘TIPO DE ENFRIAMIENTO DEL ESTATOR [ARE GRU CERRADO 70 TIPO EXCITACION ESTATICA VOLTAJE NOMINAL CAMPO 232 |vcD CORRIENTE NOMINAL DE CAMPO jaco \VOLTAJE DE CAMPO EN VACIO veo CORRIENTE DE CAMPOEN VACIO Beaa__|acd CORRIENTE DE CAMPO A CORRIENTE NOMINAL ( PBA. C.C.) 41 JACD RESISTENCIA DE CAMPO. 0.163 |OHMS @ c. CONSTANTE DE TIEMPO DE CIRCUITO ABIERTO Td0 70.479 |SEGUNDOS DATOS DEL TRANSFORMADOR DE EXCITAGION ENFRIAMIENTO FA POTENCIA IMva's CONEXION Y VOLTAJE LADO BAJA DELTA AC kv. GONEXION Y VOLTAJE LADO ALTA ESTRELLA kv. (CORRIENTE LADO BAJA 0.00 ]AMPS (CORRIENTE LADO ALTA 0.00 ]AMPS IMPEDANCIA % IMPEDANGIA EN ASPEN @ 100 MVA's CFE SUBDIRECCION DE GENERACION COMITE DE PROTECCIONES Comisién Federal de Electicided CALCULO DE AJUSTES DE PROTECCION DE GENERADOR DE ACUERDO A LA GUIA CFE-G0100-07 CENTRAL ©.C.C. POZA RICA UNIDAD __4 NO SE REQUIEREN DATOS DEL EXCITADOR POTENCIA \VOLTAJE NOMINAL DE EXCITADOR Kw veo CORRIENTE NOMINAL DE EXCITADOR Jacb \VOLTAJE DE EXCITADOR ENTRADA Ive CORRIENTE DE EXCITADOR ENTRADA Jaco FRECUENCIA lz VELOCIDAD JRPM. NO SE REQUIEREN DATOS DEL PMG POTENCIA Kw \VOLTAJE NOMINAL DEL PMG lveo CCORRIENTE NOMINAL DEL PMG laco FRECUENCIA ie VELOCIDAD RPM DATOS DEL TRANSFORMADOR DE NEUTRO VOLTAJE PRIMARIO ours \VOLTAJE SECUNDARIO yours EXISTE DIVISOR ADICIONAL? RELACION POTENCIA Kva TIEMPO EN ESTA POTENCIA secs. lonMS vous: JAMPERES RESISTENCIA DE NEUTRO ( LADO SECUNDARIO ) \VOLTAJE DE LA RESISTENCIA DE NEUTRO CORRIENTE RESISTENCIA DE NEUTRO DATOS DEL TRANSFORMADOR DE POTENCIA ENFRIAMIENTO. OA, FAZ POTENCIA 132 va's CONEXION Y VOLTAJE LADO BAJA [DELTAAG| 16.5 kv. CONEXION Y VOLTAJE LADO ALTA [ESTRELLA 118.0 Kv. ‘CORRIENTE LADO BAJA 618.94 JAMPS: CCORRIENTE LADO ALTA 662.72 104.53 ]AMPS IMPEDANCIA 6.868 x 1144 1% IMPEDANCIA EN ASPEN 0.05202 05195 0.05204 DATOS DEL TRANSFORMADOR DE SERVICIOS PROPIOS. ENFRIAMIENTO OA, FAL FAZ POTENCIA 10. 13 Mva's ‘CONEXION ¥ VOLTAJE LADO BAJA [ESTRELLA 4.46 416 kv CONEXION Y VOLTAJE LADO ALTA [DELTAAC| 16.5 165, kv CORRIENTE LADO BAJA 7387 90 7734.88 0.00 |AMPS CORRIENTE LADO ALTA 349.82 437.40 0.00 ]AMPS IMPEDANCIA a 8.00. 6 IMPEDANCIA EN ASPEN 0.60000 0.64000. 2DE29

You might also like