Calculate Door Size based on Structural Opening (mm)
Just fill in the boxes highlighted in green below, and let the calculator do the rest for you!
Work out required gap under door Frame to Wall Gap ¹
Floor Cover Thickness 15 Frame Leg Thickness ³
Finished Gap ² 3 Frame Head Thickness ⁴
Overall Gap Under Door 18 Perimeter Gap ⁵
Slave Width if
Structural Structural Leaf Width Each Leaf Width Known Master
Master Width is
Opening Width Opening Height (Single Door) (Equal Pair) Width of Pair
Known
1010 2100 926 461.5
1510 2100 1426 711.5 926 497
¹ Depending on plumness and cleanliness of opening 5-10mm - we generally work to a 7mm gap between the frame a
² Maximum finished gap on fire doors is 10mm (smoke rated doors should not exceed 3mm unless a drop seal is fitted
³ Generally 30mm for MDF and 32mm for Timer frames.
⁴ Some doors may need a larger frame head thickness (e.g. safehinge doors require a 48mm head as standard)
⁵ Perimeter gap is the gap between the frame and the door leaf (and the gap between double doors) - this is 3mm for
Standard Imperial Leaf Sizes Standard Metric Leaf Sizes
Leaf width Leaf height Leaf width Leaf height
457 1981 426 2040
533 1981 526 2040
610 1981 626 2040
686 1981 726 2040
711 1981 826 2040
762 1981 926 2040
838 1981
914 1981
7
32
32
3
Leaf Height
2040
2040
m gap between the frame and the wall.
m unless a drop seal is fitted)
m head as standard)
ble doors) - this is 3mm for fire doors.
Calculate Structural Opening based on Door Size (mm)
Just fill in the boxes highlighted in green below, and let the calculator do the rest for you!
Work out required gap under door Frame to Wall Gap ¹
Floor Cover Thickness 15 Frame Leg Thickness ³
Finished Gap ² 3 Frame Head Thickness ⁴
Overall Gap Under Door 18 Perimeter Gap ⁵
Single (or Slave Door
Master) Door Width (if Leaf Height Structural Structural
Opening Width Opening Height
Width Required)
926 2040 1010 2100
926 497 2040 1510 2100
¹ Depending on plumness and cleanliness of opening 5-10mm - we generally work to a 7mm gap between the frame a
² Maximum finished gap on fire doors is 10mm (smoke rated doors should not exceed 3mm unless a drop seal is fitted
³ Generally 30mm for MDF and 32mm for Timer frames.
⁴ Some doors may need a larger frame head thickness (e.g. safehinge doors require a 48mm head as standard)
⁵ Perimeter gap is the gap between the frame and the door leaf (and the gap between double doors) - this is 3mm for
Standard Imperial Leaf Sizes Standard Metric Leaf Sizes
Leaf width Leaf height Leaf width Leaf height
457 1981 426 2040
533 1981 526 2040
610 1981 626 2040
686 1981 726 2040
711 1981 826 2040
762 1981 926 2040
838 1981
914 1981
7
32
32
3
m gap between the frame and the wall.
m unless a drop seal is fitted)
m head as standard)
ble doors) - this is 3mm for fire doors.