0% found this document useful (0 votes)
309 views4 pages

Door Size Calculator for Structural Openings

This document contains two door size calculators. The first calculator determines the required door leaf width based on the structural opening dimensions. The user inputs the structural opening width and height and the calculator outputs the single or paired door leaf widths. The second calculator determines the structural opening dimensions based on the door leaf size and style (single or paired). It requires the user to input the door leaf width and height and outputs the corresponding structural opening width and height. Both calculators account for factors like floor covering thickness and frame dimensions when making the calculations.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
309 views4 pages

Door Size Calculator for Structural Openings

This document contains two door size calculators. The first calculator determines the required door leaf width based on the structural opening dimensions. The user inputs the structural opening width and height and the calculator outputs the single or paired door leaf widths. The second calculator determines the structural opening dimensions based on the door leaf size and style (single or paired). It requires the user to input the door leaf width and height and outputs the corresponding structural opening width and height. Both calculators account for factors like floor covering thickness and frame dimensions when making the calculations.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd

Calculate Door Size based on Structural Opening (mm)

Just fill in the boxes highlighted in green below, and let the calculator do the rest for you!

Work out required gap under door Frame to Wall Gap ¹


Floor Cover Thickness 15 Frame Leg Thickness ³
Finished Gap ² 3 Frame Head Thickness ⁴
Overall Gap Under Door 18 Perimeter Gap ⁵

Slave Width if
Structural Structural Leaf Width Each Leaf Width Known Master
Master Width is
Opening Width Opening Height (Single Door) (Equal Pair) Width of Pair
Known

1010 2100 926 461.5


1510 2100 1426 711.5 926 497

¹ Depending on plumness and cleanliness of opening 5-10mm - we generally work to a 7mm gap between the frame a
² Maximum finished gap on fire doors is 10mm (smoke rated doors should not exceed 3mm unless a drop seal is fitted
³ Generally 30mm for MDF and 32mm for Timer frames.
⁴ Some doors may need a larger frame head thickness (e.g. safehinge doors require a 48mm head as standard)
⁵ Perimeter gap is the gap between the frame and the door leaf (and the gap between double doors) - this is 3mm for

Standard Imperial Leaf Sizes Standard Metric Leaf Sizes


Leaf width Leaf height Leaf width Leaf height
457 1981 426 2040
533 1981 526 2040
610 1981 626 2040
686 1981 726 2040
711 1981 826 2040
762 1981 926 2040
838 1981
914 1981
7
32
32
3

Leaf Height

2040
2040

m gap between the frame and the wall.


m unless a drop seal is fitted)

m head as standard)
ble doors) - this is 3mm for fire doors.
Calculate Structural Opening based on Door Size (mm)
Just fill in the boxes highlighted in green below, and let the calculator do the rest for you!

Work out required gap under door Frame to Wall Gap ¹


Floor Cover Thickness 15 Frame Leg Thickness ³
Finished Gap ² 3 Frame Head Thickness ⁴
Overall Gap Under Door 18 Perimeter Gap ⁵

Single (or Slave Door


Master) Door Width (if Leaf Height Structural Structural
Opening Width Opening Height
Width Required)

926 2040 1010 2100


926 497 2040 1510 2100

¹ Depending on plumness and cleanliness of opening 5-10mm - we generally work to a 7mm gap between the frame a
² Maximum finished gap on fire doors is 10mm (smoke rated doors should not exceed 3mm unless a drop seal is fitted
³ Generally 30mm for MDF and 32mm for Timer frames.
⁴ Some doors may need a larger frame head thickness (e.g. safehinge doors require a 48mm head as standard)
⁵ Perimeter gap is the gap between the frame and the door leaf (and the gap between double doors) - this is 3mm for

Standard Imperial Leaf Sizes Standard Metric Leaf Sizes


Leaf width Leaf height Leaf width Leaf height
457 1981 426 2040
533 1981 526 2040
610 1981 626 2040
686 1981 726 2040
711 1981 826 2040
762 1981 926 2040
838 1981
914 1981
7
32
32
3

m gap between the frame and the wall.


m unless a drop seal is fitted)

m head as standard)
ble doors) - this is 3mm for fire doors.