DP‐V1 Class 2 for ProfiCaptain ‐ Quick Start Guide
Quick Start Guide The PROFIBUS and PROFINET Company Copyright © 2012 PROCENTEC. All rights reserved
Setting up the Class 1 Master (using ProfiCaptain)
Important:
If you have already have a master
running with a device in Data
Exchange, you can skip to slide 7.
Drag and drop the GSD to any
block in the Network Sheet. Then
double‐click the device.
DP‐V1 Class 2 for ProfiCaptain July 2012 2
Quick Start Guide The PROFIBUS and PROFINET Company Copyright © 2012 PROCENTEC. All rights reserved
Setting up the Class 1 Master (using ProfiCaptain)
Enter the correct address for this
device. Also, set it to ‘Active’.
Next, you can setup
the modules and
the modules and
parameters.
DP‐V1 Class 2 for ProfiCaptain July 2012 3
Quick Start Guide The PROFIBUS and PROFINET Company Copyright © 2012 PROCENTEC. All rights reserved
Setting up the Class 1 Master (using ProfiCaptain)
Add the correct modules for this
device by double‐clicking on them,
or select and then click on ‘Add
or select and then click on ‘Add
or select and then click on Add
module to Selection’.
Click ‘OK’ twice
when done.
DP‐V1 Class 2 for ProfiCaptain July 2012 4
Quick Start Guide The PROFIBUS and PROFINET Company Copyright © 2012 PROCENTEC. All rights reserved
Setting up the Class 1 Master (using ProfiCaptain)
Remember to initialize the
ProfiCore Ultra first!
Double‐click the
bl l k h
ProfiCore icon or select
‘Setup Master’
‘Setup Master
Then click on
'S /
'Set/autodetect
d
Busparameters'
DP‐V1 Class 2 for ProfiCaptain July 2012 5
Quick Start Guide The PROFIBUS and PROFINET Company Copyright © 2012 PROCENTEC. All rights reserved
Setting up the Class 1 Master (using ProfiCaptain)
Uncheck 'Use standard
h k' d d
busparameters‘. This enables
manual bus parameter
configuration.
Enter the parameters needed
for the used PA coupler.
When you’re done,
click ‘OK’ twice.
Then click 'Operate' and close the configuration window. Now ProfiCaptain is active
on the bus and the device should be online. Verify this by looking in the Live List in
ProfiTrace; you should see a master and a green device.
Jump to slide 9.
DP‐V1 Class 2 for ProfiCaptain July 2012 6
Quick Start Guide The PROFIBUS and PROFINET Company Copyright © 2012 PROCENTEC. All rights reserved
Setting up the Class 2 Master
Important:
If you have a network with PLC, you
can start from here.
Remember to initialize the
ProfiCore Ultra first!
Double‐click the
ProfiCore icon or select
‘Setup Master
‘Setup Master’
Then click on
'S /
'Set/autodetect
d
Busparameters'
DP‐V1 Class 2 for ProfiCaptain July 2012 7
Quick Start Guide The PROFIBUS and PROFINET Company Copyright © 2012 PROCENTEC. All rights reserved
Setting up the Class 2 Master (2)
Uncheck 'Use standard
Uncheck 'Use standard
busparameters‘ and click ‘Auto
detec Bus Parameters’.
After correct detection,
click ‘OK’
click OK twice.
twice.
Then click 'Operate' and close the configuration window. Now ProfiCaptain is active
on the bus as a second master Verify this by looking in the Live List in ProfiTrace; you
on the bus as a second master. Verify this by looking in the Live List in ProfiTrace; you
should see a new master.
DP‐V1 Class 2 for ProfiCaptain July 2012 8
Quick Start Guide The PROFIBUS and PROFINET Company Copyright © 2012 PROCENTEC. All rights reserved
Initiating communication
Go back to ProfiCaptain and
G b k t P fiC t i d
click the 'DP‐V1 Class2'
button.
Select the device address you wish to
Choose the slave address you wish to
communicate with. Next, click 'Initiate' to
open the DP‐V1 connection with this
device. In the log window you should see
slave. In the log window you should see
Initiate ok.
If you have ProfiTrace
message recording on
message recording on,
you can see the DP‐V1
communication.
DP‐V1 Class 2 for ProfiCaptain July 2012 9
Quick Start Guide The PROFIBUS and PROFINET Company Copyright © 2012 PROCENTEC. All rights reserved
Reading Slot/Index
B d f lt l t 1 d i d 1
By default, slot 1 and index 1
are selected. Press ‘Read’ to
retrieve the Slot/Index list of
the device.
For PA devices, you can enable PA
Profile Assistance for
interpretation of the information.
Now you are ready to read or
write slots/indexes.
DP‐V1 Class 2 for ProfiCaptain July 2012 10
Quick Start Guide The PROFIBUS and PROFINET Company Copyright © 2012 PROCENTEC. All rights reserved
Reading multiple indexes
The '+ Relative Index' can be used to
The '+ Relative Index' can be used to
The '+ Relative Index' can be used to
read a new index. Consult the
read a new index. The value will be
manual of your device for a list of
added to the value in 'Index'.
slots and indexes.
If you wish to read many different
indexes of one slot, you can use the
indexes of one slot, you can use the
'Auto increment rel.index'. Each time you
read an index, the Relative Index will be
incremented and you can click 'Read'
again to read the next index.
again to read the next index.
DP‐V1 Class 2 for ProfiCaptain July 2012 11
Quick Start Guide The PROFIBUS and PROFINET Company Copyright © 2012 PROCENTEC. All rights reserved
Writing to a slot/index The manual states that
the display tag
p y g
description is stored in
Slot 0, index 18.
The tag description is
currently empty.
If you have ‘Copy result to write
buff’ enabled, the read
information is automatically
transferred to the write section.
DP‐V1 Class 2 for ProfiCaptain July 2012 12
Quick Start Guide The PROFIBUS and PROFINET Company Copyright © 2012 PROCENTEC. All rights reserved
Writing to a slot/index (2)
Fill in new information in
plain text or in hex and
plain text or in hex and
click ‘Write’.
Be sure to check the
correct radio button.
DP‐V1 Class 2 for ProfiCaptain July 2012 13
Quick Start Guide The PROFIBUS and PROFINET Company Copyright © 2012 PROCENTEC. All rights reserved
Other buttons
The log window can be saved
for later review.
YYou can clear all the information
l ll th i f ti
with the ‘Clear’ button.
DP‐V1 Class 2 for ProfiCaptain July 2012 14
Quick Start Guide The PROFIBUS and PROFINET Company Copyright © 2012 PROCENTEC. All rights reserved