0 LOAD CALCULATIONS
2.1 DEAD WEIGHT CALCULATIONS:
DECK WEIGHT
Span of deck = 32.3m
Width of deck = 18.52 m
Avg. thickness of deck = 0.3m
Density of Rcc = 2500 Kg/m^3
Vol of deck = span x width x avg thickness=32.3x18.52x.3
=179.5 m^3
Total weight of deck = vol of deck x density = 179.5x2500/1000
= 448.65 Ton
GIRDER WEIGHT
Girder length = 31.7m
Girder area = 0.10m (As per super structure section property)
No. of Girders = 8
Density of steel =7850 Kg/m^3
Vol of Girder = length x area x no of girder = 31.7 x 0.10 x 8
= 3.04 m^3
Weight of girders = vol x density =3.04 x 7850/1000
=228.86 T
Total Weight of girders (30% extra) = 228.86 x 1.3 =298 t
BALLAST LOAD
Ballast width =16.52m
Ballast length =32.3m
Avg thickness of ballast =0.5m
Density of ballast 1800 Kg/m^3
Vol of ballast = ballast width x ballast length x avg thickness
= 16.52 x 32.3 x 0.5 = 266.8 m^3
Total Weight of ballast = vol x density of ballast = 266.8 x 1800/1000
=480.3 T
BALLAST RETAINER LOAD
Ballast retainer width = 0.15m
Ballast retainer length= 32.3m
Avg thickness of ballast retainer= 0.95m
Vol of ballast retainer = ballast retainer width x ballast retainer length x avg thickness
= .015 x 32.3 x .95 = 9.21 m^3
Total Weight of ballast retainer = vol of ballast retainer x density of ballast
= 9.21 x 1800/1000 = 16.57 ton
HADRAILING
Weight of hand railing 50kg/m
Total weight of hand railing = weight x length x no.
= 50 x 32.3 x 2/1000 =3.23T
FOOTPATH WEIGHT
Weight of footpath 72kg/m^2
Total weight of hand railing= weight x length x no.
=72 x 32.3 x 2/1000 = 4.65 T
2.2 PORTAL BEAM SHRINKAGE EFFECTS: The shrinkage effects for portal beam will create lateral
force and moments in piers which is being considered along with long term elastic modulus of piers
which presented as following.
Maximum shrinkage strain in portal beam, sh = 0.0003 ( As per CL: 5.2.3.1 of IRS CBC)
Grade of Concrete of Piers = M45, concrete grade for portal beam=45Mpa, Elastic Modulus =
32500Mpa, creep Coefficient for piers = 1.6 (at 28 days), thermal expansion coeff = 1.7E-5
The analysis of portal piers shall be done using above parameters, however for the sake of simplicity
a equivalent temp fall load being applied on portal beams to get the desired effects on piers as
following.
Equivalent Temp Fall Load = -(sh / x 1/(1+creep coeff.) = -0.0003/1.3e-5x1/(1+1.6)=-8.87 degree
The above temperature load (-8.87 degree) shall be applied on portal beams with thermal expansion
coeff for piers shall be 1.3e-5.
2.3 THERMAL FORCES The temperature variation for portal beam is considered as +/- 35 degree
centigrade for the analysis and design of sub structure.
The braking tractive force has been calculated as per IRS bridge rule, the braking forces are
following.
Total no of tracks = 3
Total Breaking and tractive force, Hr= 3x 1000= 3000 kN for three tracks. -------------------(a)
Total Load of one span = Girder weight+ Deck weight+ Ballast + ballast retainer +sleeper + rail +Live
load
= 22900 kN
HFL 802.68
Scour Level 799.23
Submerged height of pier h = 3.45 m
Seismic Coeff. Ah = 0.36
Diameter of envelope a = 2.3 m
Weight of water in encevelope We = 143.2664 kN
Ce ( coefficient as per Table 4 of IRS Seismic Code
h/a = 1.50
Ce = 0.482
Total Horizontal Force F = Ce. Ah. We
F = 24.89 kN
P = K .A .V2
K ( Shape factor ) = 35
A ( Area in elivation exposed to water face) 7.935 m2
V ( max mean velocity of water) 3 m/s
Lumped Mass of Super Structure = Girder weight+ Deck weight+ Ballast + ballast retainer +sleeper +
rail
= 7954 kN
= 5058 kN
Lumped mass of Portal beam and substructure = Self weight as per analysis model
Deflection Under Lumped Mass(Deflection has been calculated based on 75% of Gross Moment of Inertia for pier)
Table 1Refer Staad Model
Longitudinal Vibration mode: The deflection under lumped mass has been calculated at Pier Cap top
under selfweight and SIDL.
Transverse Vibration mode: The deflection under lumped mass has been calculated at Pier Cap top
under self weight, SIDL and 50%Live Load.
Vertical Vibration mode: The deflection under lumped mass has been calculated at Pier Cap top
under self weight, SIDL and 50%Live Load.
Seismic Coefficient for Portal Beam: Response reduction factor for portal beam shall be considered
as R=1 and I=1.5. The seismic Coefficient to be as following.
Longitudinal Vertical
Transverse Seismic
Seismic Seismic
As per As per As per
Seismic
Site Site As Site
Parameters As per As per
specific specific per specific
Code Code
Seismic Seismic Code Seismic
spectra spectra spectra
R 1 1 1 1 1 1
I 1.5 1.5 1.5 1.5 1.5 1.5
Seismic Coeff
0.183375 0.21975 0.275625 0.33075 0.675 0.8175
with Load Factor
0.545(2/3 OF
Max for design 0.21975 0.33075
0.8175)
Seismic Coefficient for Portal Columns: Response reduction factor for portal beam shall be
considered as R=3 and I=1.5. The seismic Coefficient to be as following.
DESIGN SEISMIC COEFFICIENT FOR COLUMNS
Longitudinal Vertical
Transverse Seismic
Seismic Seismic
As per As per As per
Seismic
Site Site As Site
Parameters As per As per
specific specific per specific
Code Code
Seismic Seismic Code Seismic
spectra spectra spectra
R 3 3 3 3 3 3
I 1.5 1.5 1.5 1.5 1.5 1.5
Seismic Coeff
0.061125 0.07325 0.091875 0.11025 0.225 0.2725
with Load Factor
0.18(2/3 OF
Max for design 0.07325 0.11025
0.27)
Seismic Coefficient for Seismic Stopper: Response reduction factor for portal beam shall be
considered as R=1 , I=1.5 and a factor of 2 for impact loading. The seismic Coefficient to be as
following.
Longitudinal Transverse
Vertical Seismic
Seismic Seismic
As per As per As per
Seismic
Site Site Site
Parameters As per As per As per
specific specific specific
Code Code Code
Seismic Seismic Seismic
spectra spectra spectra
ZxSa/g 0.163 0.293 0.245 0.441 0.6 1.09
R 1 1 1 1 1 1
I 1.5 1.5 1.5 1.5 1.5 1.5
Impact factor 2 2 2 2 2 2
Seismic Coeff
0.36675 0.4395 0.55125 0.6615 1.35 1.635
with Load Factor
1.09(2/3
Max for design 0.4395 0.6615
OF 1.64)
Lumped Mass of Super Structure = Girder weight+ Deck weight+ Ballast + ballast retainer +sleeper +
rail
= 7954 kN
= 5058 kN
Lumped mass of Portal beam and substructure = Self weight as per analysis model
Deflection Under Lumped Mass(Deflection has been calculated based on 75% of Gross Moment of Inertia for pier)
Table 2Refer Staad Model
Longitudinal Vibration mode: The deflection under lumped mass has been calculated at Pier Cap top
under selfweight and SIDL.
Transverse Vibration mode: The deflection under lumped mass has been calculated at Pier Cap top
under self weight, SIDL and 50%Live Load.
Vertical Vibration mode: The deflection under lumped mass has been calculated at Pier Cap top
under self weight, SIDL and 50%Live Load.
Analysis of structure is performed considering Seismic Mass and Seismic forces results from Staad
Analysis to be multiply by ZxSa/gxI/R and load factor in load combinations for each elements
separately.
Seismic Coefficient for Portal Beam: Response reduction factor for portal beam shall be considered
as R=1 and I=1.5. The seismic Coefficient to be as following.
R 1 1 1 1 1 1
I 1.5 1.5 1.5 1.5 1.5 1.5
0.55(2/3 OF
Max for design 0.22875 0.30525
0.83)
Seismic Coefficient for Portal Columns: Response reduction factor for portal beam shall be
considered as R=3 and I=1.5. The seismic Coefficient to be as following.
R 3 3 3 3 3 3
I 1.5 1.5 1.5 1.5 1.5 1.5
Seismic Coeff
0.063375 0.07625 0.08475 0.10175 0.225 0.275
with Load Factor
0.18(2/3 OF
Max for design 0.07625 0.10175
0.28)
Seismic Coefficient for Seismic Stopper: Response reduction factor for portal beam shall be
considered as R=1 , I=1.5 and a factor of 2 for impact loading. The seismic Coefficient to be as
following.
DESIGN SEISMIC COEFFICIENT FOR SEISMIC STOPPER
Longitudinal Transverse
Vertical Seismic
Seismic Seismic
As per As per As per
Seismic
Site Site Site
Parameters As per As per As per
specific specific specific
Code Code Code
Seismic Seismic Seismic
spectra spectra spectra
R 1 1 1 1 1 1
I 1.5 1.5 1.5 1.5 1.5 1.5
Impact factor 2 2 2 2 2 2
Seismic Coeff
0.38025 0.4575 0.5085 0.6105 1.35 1.65
with Load Factor
1.1(2/3
Max for design 0.4575 0.6105 OF
1.65)
As the analysis is performed using seismic mass in all directions, the seismic forces shall be
multiplied by Max design seismic coefficient as calculated(which included Load Factors) in above
table with directional combination factors (100% considered direction and 30% for other directions) .
Seismic Load Combinations shall be as per IRS seismic code 2020 which as followings
2.9 WIND
2
FT = PZ A1 Ct = 647.0 Kg/m Ct= 1.90
2
FL ( 0.25*FT ) = 161.8 Kg/m (-Cp)= 0.75
2
Fv = PZ A3 - Cp = 68.1 Kg/m (+Cp)= 0.20
3
Fv = PZ A3 +Cp = 255.4 Kg/m
Effective height of column = 2.3xh (longitudinal direction or moment about transverse axis)
As the pier is circular type hence effective pier height is considered 2.3xh and slender moment is
added in resultant moment of both axis.
The slenderness moment calculations has been applied separately in force table for columns.