Parameters - PowerFlex 400 3P 460V 250HP 2016-12-09 12:33:33

# Name Value Units Internal Default Min Max


Value
1 Output Freq 41.40 Hz 4140 0.00 0.00 320.00
2 Commanded Freq 41.40 Hz 4140 0.00 0.00 320.00
3 Output Current 168.6 A 1686 0.0 0.0 620.0
4 Output Voltage 323 Vac 323 0 0 510
5 DC Bus Voltage 542 Vdc 542 0 0 820
6 Drive Status 00000000 00000011 3 00000000 0 15
00000000
7 Fault 1 Code 15 15 0 0 9999
8 Process Display 1242 1242 0 0 9999
10 Output Power 69.5 kW 695 0.0 0.0 999.9

11 Elapsed MWh 1729.9 MWh 17299 0.0 0.0 3276.7

12 Elapsed Run Time 5458 x10h 5458 0 0 9999

13 Torque Current 125.3 A 1253 0.0 0.0 620.0

14 Drive Temp 49 C 49 0 0 120

15 Elapsed kWh 80.9 kWh 809 0.0 0.0 100.0

31 Motor NP Volts 380 Vac 380 460 20 460

32 Motor NP Hertz 50 Hz 50 60 15 320

33 Motor OL Current 340.0 A 3400 310.0 0.0 620.0

34 Minimum Freq 10.0 Hz 100 0.0 0.0 320.0

35 Maximum Freq 50.0 Hz 500 60.0 0.0 320.0

36 Start Source Comm Port 5 2-W Lvl 0 6


Sens
37 Stop Mode Ramp 4 Coast, CF 0 7

38 Speed Reference Comm Port 5 Analog In 1 0 5

39 Accel Time 1 120.00 Sec 12000 60.00 0.00 600.00

40 Decel Time 1 150.00 Sec 15000 60.00 0.01 600.00

42 Auto Mode Local/Remote 2 Hnd-Off- 0 3


Auto
43 Motor OL Ret Enabled 1 Disabled 0 1

101 Language Español 3 English 1 10

105 Comm Loss Action Stop 2 Fault 0 5

108 Start Source 2 2-W Lvl/Enbl 6 2-W Lvl 0 6


Sens
141 Purge Frequency 20.0 Hz 200 5.0 0.0 320.0

149 S Curve % 30 % 30 20 0 100

163 Auto Rstrt Tries 5 5 0 0 9

164 Auto Rstrt Delay 10.0 Sec 100 1.0 0.0 160.0

167 Flying Start En Enabled 1 Disabled 0 1

170 Boost Select 0.5, CT 8 45.0, VT 0 15

172 Break Voltage 15.0 % 150 25.0 0.0 100.0

Page 1 of 2
Parameters - PowerFlex 400 3P 460V 250HP 2016-12-09 12:33:33

# Name Value Units Internal Default Min Max


Value
173 Break Frequency 10.0 Hz 100 15.0 0.0 320.0

174 Maximum Voltage 400 Vac 400 460 20 510

177 DC Brake Level 5.0 A 50 15.5 0.0 465.0

179 Current Limit 1 350.0 A 3500 341.0 0.0 465.0

180 Current Limit 2 350.0 A 3500 341.0 0.0 465.0

181 Motor OL Select Min Derate 1 No Derate 0 2

182 Drive OL Mode Reduce CLim 1 Both-PWM 0 3


1st
184 Load Loss Level 5.0 A 50 0.0 0.0 310.0

185 Load Loss Time 10 Sec 10 0 0 9999

200 Motor NP FLA 280.0 2800 277.5 0.1 620.0

301 Control Source 52 52 0 0 99

302 Contrl In Status 00000000 00000100 4 00000000 0 255


00000000
303 Comm Status 00000000 00001101 13 00000000 0 15
00000000
307 Fault 1 Code 15 15 0 0 9999

308 Fault 2 Code 12 12 0 0 9999

309 Fault 3 Code 15 15 0 0 9999

310 Fault 1 Time-hr 32767 Hr 32767 0 0 32767

311 Fault 1 Time-min 48.2 Min 482 0.0 0.0 60.0

312 Fault 2 Time-hr 32767 Hr 32767 0 0 32767

313 Fault 2 Time-min 37.4 Min 374 0.0 0.0 60.0

314 Fault 3 Time-hr 32767 Hr 32767 0 0 32767

315 Fault 3 Time-min 4.7 Min 47 0.0 0.0 60.0

316 Elapsed Time-hr 32767 Hr 32767 0 0 32767

317 Elapsed Time-min 13.0 Min 130 0.0 0.0 60.0

318 Output Powr Fctr 41.4 Deg 414 0.0 0.0 180.0

319 Testpoint Data 00100001 01110110 8566 00000000 0 65535


00000000
320 Control SW Ver 5.03 503 0.00 0.00 99.99

321 Drive Type 5824 5824 0 0 9999

322 Output Speed 82.8 % 828 0.0 0.0 100.0

323 Output RPM 1242 rpm 1242 0 0 24000

324 Fault Frequency 14.07 Hz 1407 0.00 0.00 320.00

325 Fault Current 2.2 A 22 0.0 0.0 620.0

326 Fault Bus Volts 560 Vdc 560 0 0 820

327 Status @ Fault 00000000 00001011 11 00000000 0 15


00000000