You are on page 1of 2

Gas velocity measurement for

F LOWS I C 100
cement kiln flue gas conditioning
M arket S egment
Segment and regulated by the quantity only. Sometimes these
A typical market segment for of cooling water supplied to control circuits can be further
the FLOWSIC gas velocity the cooler to optimize the optimized by measuring the
monitor is the cement processes involved .Thus the energy content of the flue
industry. In cement plants filter efficency will be gases additionally.The gas
using electrostatic gas increased and the level of velocity measurement, and
P L I C AT I O N

cleaning systems, dust emissions minimized. In thus the volumetric flow,


conditioning of the hot flue most cases, the coolant required for this purpose can
gases regarding temperature supply is regulated via be performed with the
and dew point is neccessary temperature control circuits FLOWSIC measuring device.

Process material in the process energy content of the flue


AP

Cement clinker is (combined operation), gas upstream of the cooling


manufactured by burning a whereby they are cooled and tower into account, however,
mixture of limestone, clay, absorb moisture. Preparing the required coolant supply
Results and sand in a rotary kiln at the flue gases before should be additionally
temperatures up to 1450 °C. cleaning them in an electro- corrected according to the
u Optimized flue gas After they have been cleaned, static filter system involves current energy content of the
conditioning the hot and dust-laden flue conditioning them in an gas flow, since an inadquate
u Increased filter gases from the kiln in some evaporative type cooler. The water supply leads to
efficiency cases are released directly temperature upstream of the insufficient cooling and
into the atmosphere via the filter system is primarily used increased emis-sion levels
u Reduced dust
flue gas stack (direct as a reference variable to and -conversely- an excess
emission level operation). Sometimes, determine the required supply can lead to sludge
however, the flue gases are coolant supply. In order to formation in the cooler and
used beforehand to dry the take fluctuations in the thus cause operating
malfunctions.

Flue gas ➤
FLOWSIC 105

➤ Cooling water ➤

Kiln Evaporation cooler



Flame

➤ To stack
➤ Material flow Electrostatic filter
➤ Flue gas

Evaporation cooler and FLOWSIC


(schematic)
Measuring Task Operational parameter at measuring location:
The task here is to measure with high u High dust concentrations up to 100 g/m³³ 3
reliability the velocity of the hot flue gases u Gas temperatures up to 400 °C
continuously under boundary conditions and u Considerable fluctuations in the humidity content
to calculate the volumetric flow. u Considerable fluctuations in the gas flow rate
u Extreme ambient conditions at measuring location

Measuring Solution
The FLOWSIC 105 has been designed for tasks of this kind.
The ultrasonic measuring principle with
its characteristics make it particularly
suitable for these applications. Its two
combined transmitter/receiver units,
which are mounted opposite one
another at an angle of 60 ° at the gas
duct -not inside! - transmit and receive
ultrasonic signals. The propagation
delay time of these pulses is FLOWSIC 105 (one part)
measured in and against the gas flow at the gas ducct
direction. The gas velocity is calculated
from this difference and, together with the dimensions of the
gas duct, is used to derive the volumetric flow.
FLOWSIC 105 has already proven itself in many applications of this type.

Benefits
The benefits of using FLOWSIC for this application are based on the properties
of the ultrasonic measuring principle:
➤ No sensitive and movable parts in the gas flow. ➤ Representative values by integral measurement along
one axis (Cross stack).
➤ High level of accuracy across the entire measuring ➤ No backflush, no compressed air needed;
range, even near the zero point. extremely low maintenance requirements.
➤ Air purging keeps transducer clean with ➤ Remote parameter setting for FLOWSIC possible from
additional cooling effect the control station using the evaluation unit.

In short, this means:


By taking into account the energy content of the flue
gas, an effective closed-loop control system that
operates in realtime is provided to determine the
required cooling water supply and thus support uniform
process control.
This is ensured by gas velocity measurements with the
FLOWSIC 105 measuring device, which operates
reliably even under extreme conditions.
Traditional measuring methods will usually reach their
limits with this application.

SICK AG • Environmental Monitoring • Nimburger Str. 11 • D-79276 Reute • Germany


Tel. +49 76 41 / 4 69-0 • Fax. +49 76 41 / 4 69-11 49 • http://www.sick.de