Professional Documents
Culture Documents
© 2007 Extreme Networks, Inc. All rights reserved. Summit X150 Series—Page 1
Extreme Networks Data Sheet
© 2007 Extreme Networks, Inc. All rights reserved. Summit X150 Series—Page 2
Extreme Networks Data Sheet
Voice-Class Availability
Powered by ExtremeXOS, the Summit X150 switch supports process recovery and application upgrades without the need for a
system reboot. Summit X150 offers the high network availability required for converged applications.
© 2007 Extreme Networks, Inc. All rights reserved. Summit X150 Series—Page 3
Extreme Networks Data Sheet
User Authentication and Host model from the Trusted Computing Group. Network Intrusion Detection
Summit X150 interfaces with Sentriant AG
Integrity Checking and Response
endpoint security software from
Network Login Extreme Networks to verify that each Hardware-Based sFlow Sampling
Network Login capability enforces user endpoint meets the security policies that sFlow is a sampling technology that provides
admission and usage policies. Summit X150 have been set, and quarantines those that are the ability to continuously monitor applica-
series switches support a comprehensive not in compliance. tion level traffic flows on all interfaces
range of Network Login options by simultaneously. The sFlow agent is a
providing an 802.1x agent-based approach, Extensive MAC and IP Security software process that runs on Summit X150
a web-based (agent-less) login capability switches and packages data into sFlow
for guests, and a MAC-based authentica-
Functionality datagrams that are sent over the network to
tion model for devices. With these modes MAC Security an sFlow collector. The collector gives an
of Network Login, only authorized users MAC security allows the lock down of a port up-to-the minute view of traffic across the
and devices are permitted to connect to to a given MAC address and to limit the entire network, providing the ability to
the network and be assigned to the number of MAC addresses on a port. This can troubleshoot network problems, control
appropriate VLAN. be used to dedicate ports to specific hosts or congestion and detect network security
devices such as VoIP phones or printers and threats.
Multiple Supplicant Support avoid abuse of the port—an interesting
Shared ports represent a potential vulner- capability specifically in environments such Port Mirroring
ability in a network. Multiple supplicant as hotels. In addition, an aging timer can be To allow threat detection and prevention,
capability on a switch allows it to uniquely configured for the MAC lockdown, protecting Summit X150 switches support many-to-
authenticate and apply the appropriate the network from the effects of attacks using one and one-to-many port mirroring. This
policies and VLANs for each user or device (often rapidly) changing MAC addresses. allows the mirroring of traffic to an
on a shared port. external network appliance such as an
IP Security intrusion detection device for trend
Multiple supplicant support helps secure IP ExtremeXOS IP Security Framework helps analysis or for utilization by a network
Telephony and wireless access. Converged protect the network infrastructure, network administrator for diagnostic purposes.
network designs often involve the use of services such as DHCP and DNS and host
shared ports (see Figure 2). computers from spoofing and man-in-the Line-Rate ACLs
middle attacks. It also helps protect the ACLs are one of the most powerful
Host Integrity Checking network from statically configured and/or components used in controlling network
Host integrity checking helps keep infected spoofed IP addresses and builds an external resource utilization as well as protecting
or non-compliant machines off the trusted database of MAC/IP/port bindings the network. Summit X150 switches
network. Summit X150 series switches providing the traffic’s source from a specific support 1,024 centralized ACLs per
support a host integrity or endpoint address for immediate defense. 24-port based on Layer 2, 3 or 4-header
integrity solution that is based on the information such as the MAC, IPv4 and
IPv6 address or TCP/UDP port.
Secure Management
To prevent management data from being
intercepted or altered by unauthorized
` ` ` ` ` ` ` ` ` access, Summit X150 supports SSH2, SCP
and SNMPv3 protocols.
© 2007 Extreme Networks, Inc. All rights reserved. Summit X150 Series—Page 4
Extreme Networks Data Sheet
Target Applications
© 2007 Extreme Networks, Inc. All rights reserved. Summit X150 Series—Page 5
Extreme Networks Data Sheet
Technical Specifications
ExtremeXOS V12.0 Supported
Protocols
Switching
• RFC 9 Ethernet Automatic Protection Switching • RFC 2465, IPv6 MIB, General Group and Textual • RFC 2138 RADIUS Authentication
(EAPS) and EAPSv2 Conventions • RFC 2139 RADIUS Accounting
• IEEE 802.1D – 1998 Spanning Tree Protocol • RFC 2466, MIB for ICMPv6 • RFC 3579 RADIUS EAP support for 802.1x
(STP) • RFC 1981, Path MTU Discovery for IPv6, August • RADIUS Per-command Authentication
• IEEE 802.1D – 2004 Spanning Tree Protocol 1996 • Access Policies for Telnet/SSH-2/SCP-2
(STP and RSTP) • RFC 3513, Internet Protocol Version 6 (IPv6) • Network Login - 802.1x, web and MAC-based
• IEEE 802.1w – 2001 Rapid Reconfiguration for Addressing Architecture mechanisms
STP, RSTP • RFC 3587, Global Unicast Address Format • IEEE 802.1x – 2001 Port-Based Network
• IEEE 802.1Q-2003 (formerly IEEE 802. s) • RFC 2710, IPv6 Multicast Listener Discovery v1 Access Control for Network Login
Multiple Instances of STP, MSTP (MLDv1 ) Protocol • Multiple supplicants with multiple VLANs for
• EMISTP, Extreme Multiple Instances of • RFC 3810, IPv6 Multicast Listener Discovery v2 Network Login (all modes)
Spanning Tree Protocol (MLDv2) Protocol • Fallback to local authentication database (MAC
• PVST+, Per VLAN STP (802. Q interoperable) • Telnet server over IPv6 transport and Web-based methods)
• IEEE 802.1Q – 998 Virtual Bridged Local Area • SSH-2 server over IPv6 transport • Guest VLAN for 802.1x
Networks • Ping over IPv6 transport • RFC 1866 HTML – Used for web-based Network
• IEEE 802.3ad Static load sharing configuration • Traceroute over IPv6 transport Login
and LACP based dynamic configuration Management and Traffic Analysis • SSL/TLS transport – used for for web-based
• IEEE 802.1AB – LLDP Link Layer Discovery • RFC 2030 SNTP, Simple Network Time Protocol v4 Network Login, (requires export controlled
Protocol • RFC 854 Telnet client and server encryption module)
• LLDP Media Endpoint Discovery (LLDP-MED), • RFC 783 TFTP Protocol (revision 2) • MAC Security – Lockdown and Limit
ANSI/TIA-1057, draft 08 • RFC 951, 1542 BootP • IP Security – RFC 3046 DHCP Option 82 with
• Extreme Discovery Protocol (EDP) • RFC 2131 BOOTP/DHCP relay agent and port and VLAN ID
• Extreme Loop Recovery Protocol (ELRP) DHCP ser ver • IP Security – Source IP Lockdown
• Extreme Link State Monitoring (ELSM) • RFC 1591 DNS (client operation) • IP Security – Trusted DHCP Server
• Software Redundant Ports • RFC 1155 Structure of Mgmt Information (SMIv1) • Layer 2/3/4 Access Control Lists (ACLs)
VLANs, vMANs • RFC 1157 SNMPv1 Denial of Service Protection:
• IEEE 802.1Q VLAN Tagging • RFC 1212, RFC 1213, RFC 1215 MIB-II, Ethernet- • RFC 2267 Network Ingress Filtering
• IEEE 802.1v: VLAN classification by Protocol Like MIB & TRAPs • Wire-speed ACLs
and Port • RFC 1573 Evolution of Interface • Rate Limiting / Shaping by ACLs
• Port-based VLANs • RFC 1650 Ethernet-Like MIB (update of RFC • IP Broadcast Forwarding Control
• Protocol-based VLANs 1213 for SNMPv2) • ICMP and IP-Option Response Control
• Multiple STP domains per VLAN • RFC 1901 – 1908 SNMP v2c, SMIv2 and • SYN attack protection
• IEEE 802.1ad Virtual MANs (vMANs) Revised MIB-II • CPU DoS Protection with traffic rate-limiting to
Quality of Service and Policies • RFC 2570 – 2575 SNMPv3, user based security, management CPU
• IEEE 802.1D – 998 (802. p) Packet Priority encryption and authentication • Robust against common Network Attacks:
• RFC 2474 DiffServ Precedence, including 8 • RFC 2576 Coexistence between SNMP Version 1, ––CERT (http://www.cert.org)
queues/port Version 2 and Version 3 ––CA-2003-04: “SQL Slammer”
• RFC 2598 DiffServ Expedited Forwarding (EF) • RFC 1757 RMON 4 groups: Stats, History, ––CA-2002-36: “SSHredder”
• RFC 2597 DiffServ Assured Forwarding (AF) Alarms and Events ––CA-2002-03: SNMP vulnerabilities
IPv4 • RFC 2021 RMON2 (probe configuration) ––CA-98-13: tcp-denial-of-service
• RFC 1519 CIDR • RFC 2668 802.3 MAU MIB ––CA-98.01: smurf
• RFC 1122 Host Requirements • RFC 1643 Ethernet MIB ––CA-97.28:Teardrop_Land -Teardrop and
• RFC 768 UDP • RFC 1493 Bridge MIB “LAND“ attack
• RFC 791 IP • RFC 1354 IPv4 Forwarding Table MIB ––CA-96.26: ping
• RFC 792 ICMP • RFC 2737 Entity MIB v2 ––CA-96.21: tcp_syn_flooding
• RFC 793 TCP • RFC 2233 Interface MIB ––CA-96.01: UDP_service_denial
• RFC 826 ARP • RFC 1354 IP Forwarding Table MIB ––CA-95.01: IP_Spoofing_Attacks_and_
• RFC 894 IP over Ethernet • Draft-ietf-bridge-rstpmib-03.txt – Definitions of Hijacked_ Terminal_Connections
• RFC 1027 Proxy ARP Managed Objects for Bridges with Rapid ––IP Options Attack
• RFC 2068 HTTP server – Used for web-based Spanning Tree Protocol • Host Attacks
Network Login • Secure Shell (SSH-2) client and server ––Teardrop, boink, opentear, jolt2, newtear,
• RFC 1112 IGMP v1 • Secure Copy (SCP-2) client and server nestea, syndrop, smurf, fraggle, papasmurf,
• RFC 2236 IGMP v2 • Secure FTP (SFTP) server synk4, raped, winfreeze, ping –f, ping of
• RFC 3376 IGMP v3 • sFlow version 5 death, pepsi5, Latierra, Winnuke, Simping,
• IGMP v1/v2/v3 Snooping • Configuration logging Sping, Ascend, Stream, Land, Octopus
• IGMP Filters • Multiple Images, Multiple Configs
• Static IGMP Membership • BSD System Logging Protocol (SYSLOG), with
• Multicast VLAN Registration Multiple Syslog Servers
IPv6 ––999 Local Messages (criticals stored across Summit X150-24t
• RFC 2460, Internet Protocol, Version (IPv6) reboots) General Specifications
Specification • Extreme Networks vendor MIBs (includes FDB, Performance
• RFC 2461, Neighbor Discovery for IP Version 6, PoE, CPU, Memory MIBs) • 8.8 Gbps switch fabric bandwidth
(IPv6) • Web-based device management interface • 6.5 Mpps frame forwarding rate
• RFC 2462, IPv6 Stateless Address Auto Security • 9,216 Byte maximum packet size (Jumbo Frame)
configuration • Secure Shell (SSH-2), Secure Copy (SCP-2) and • 13 load sharing trunks, up to 8 members per trunk
• RFC 2463, Internet Control Message Protocol SFTP client/server with encryption/authentication • 8 QoS queues/port
(ICMPv6) for the IPv6 Specification (requires export controlled encryption module) • 4,094 VLANs (Port, Protocol, IEEE 802.1Q)
• RFC 2464, Transmission of IPv6 Packets over • SNMPv3 user based security, with encryption/ • 1,024 centralized ACL rules per switch
Ethernet Networks authentication (see above)
• RFC 1492 TACACS+
© 2007 Extreme Networks, Inc. All rights reserved. Summit X150 Series—Page 6
Extreme Networks Data Sheet
Technical Specifications
Forwarding Tables • Acoustic Noise (Low FAN Speed): 37 dBA per • Operational Shock (Half Sine): 30 m/s2 (3g),
• Layer 2/MAC Addresses: 8K ISO 7779 11ms, 60 Shocks
Rate Limiting • Acoustic Noise (High FAN Speed): 45 dBA per • Operational Random Vibration: 5 – 500 Hz @
• Ingress bandwidth policing/rate limiting per flow ISO 7779 1.5g rms
• Egress bandwidth rate limiting per egress queue External Power Supply - EPS-160 Storage & Transportation Conditions (Packaged)
• Rate Limiting Granularity: 64Kbps • Voltage Input Range: 90 – 264V • Transportation Temperature: -40° C to 70° C
• Available Rate Limiters: 1,024 per switch • Nominal Input Ratings: 100 – 240V~, (- 40° F to 158° F)
Indicators 50 – 60 Hz, 4A • Storage and Transportation Humidity: 60% to
• Per port status LED • Line Frequency Range: 47 – 63 Hz 95% RH, non-condensing
• System Status LEDs: management, fan and • Maximum Input Current: 2A at 115 VAC, 1A at • Packaged Shock (Half Sine): 180 m/s2 (18g),
power 230 VAC 6ms, 600 shocks
Ports • Maximum Inrush Current: 30A at 115 VAC, 60A • Packaged Sine Vibration: 5 – 62 Hz @ Velocity
• 24 ports 10/100BASE-T with auto-speed and at 230 VAC 5mm/s, 62 – 500 Hz @ 0.2 G
auto-polarity • Power Supply Input Socket: IEC 320 C14 • Packaged Random Vibration: 5 – 20 Hz @ 1.0
• 2 ports Gigabit Ethernet (SFP mini-GBIC, shared • Power Cord Input Plug: IEC 320 C13 ASD w/-3dB/oct. from 20 – 200 Hz
PHY with 2 10/100/1000BASE-T ports) • Heat Dissipation: 38.5W (131.4 BTU/h) • 14 drops min on sides & corners @ 42”
• 1 port Serial (control port) • Power Consumption: 178W (607.4 BTU/h) (<15kg box)
• 1 10/100BASE-T out-of-band management port Power & Accoustic Sound
• Voltage Input Range: 90 – 264V
Physical Specifications Summit X150-48t • Nominal Input Ratings: 100 – 240V~, 50/60 Hz,
1.0A
Dimensions and Weight General Specifications • Input Current: 0.6A @ 115V~ (lowline) 0.3A @
Height: 1.73 Inches/4.4 Cm Performance 230V~ (high-line)
Width: 17.35 Inches/44.1 Cm • 13.6 Gbps switch fabric bandwidth • Maximum In-Rush Current: 30A @115V/60 Hz,
Depth: 12.13 Inches/30.8 Cm • 10.1 Mpps frame forwarding rate Max Load
Weight: 10.47 Lbs/4.76 Kg • 9,216 Byte maximum packet size (Jumbo Frame) • Efficiency: 83% with 60% – 100% load
EPS Dimensions and Weight • 25 load sharing trunks, up to 8 members per trunk • Line Frequency Range: 47 – 63 Hz
EPS-T • 8 QoS queues/port • Power Supply Input Socket: IEC 320 C14
Height: 1.75 Inches/4.4 Cm • 4,094 VLANs (Port, Protocol, IEEE 802.1Q) • Power Cord Input Plug: IEC 320 C13
Width: 17.4 Inches/44 Cm • 1,024 centralized ACL rules per 24-port • Heat Dissipation: 51W (174 BTU/h)
Depth: 7.6 Inches/19.3 Cm Forwarding Tables • Power Consumption: 51W (174 BTU/h)
• Layer 2/MAC Addresses: 8K • Acoustic Noise (Low FAN Speed): 37 dBA per ISO
EPS-160
Rate Limiting 7779
Height: 1.7 Inches/4.3 Cm
• Ingress bandwidth policing/rate limiting per flow • Acoustic Noise (High FAN Speed): 47 dBA per
Width: 7.4 Inches/18.8 Cm
• Egress bandwidth rate limiting per egress queue ISO 7779
Depth: 7.9 Inches/20 Cm
• Rate Limiting Granularity: 64Kbps External Power Supply - EPS-160
• Available Rate Limiters: 1,024 per switch • Voltage Input Range: 90 – 264V
Operating Specifications Indicators • Nominal Input Ratings: 100 – 240V~,
Temperature • Per port status LED including power status 50 – 60 Hz, 4A
• Operating Temperature Range: 0° C to 40° C • System Status LEDs: management, fan and power • Line Frequency Range: 47 – 63 Hz
(32° F to 104° F) • Maximum Input Current: 2A at 115 VAC, 1A at
Ports
• Operating Humidity: 10% to 93% relative 230 VAC
• 48 ports 10/100BASE-T PoE with auto-speed
humidity, non-condensing • Maximum Inrush Current: 30A at 115 VAC, 60A
and auto-polarity
• Operational Shock (Half Sine): 30 m/s2 (3g), at 230 VAC
• 2 ports Gigabit Ethernet (SFP mini-GBIC, shared
11ms, 60 Shocks • Power Supply Input Socket: IEC 320 C14
PHY with 2 10/100/1000BASE-T ports)
• Operational Random Vibration: 5 – 500 Hz @ • Power Cord Input Plug: IEC 320 C13
• 1 port serial (console port)
1.5g rms • Heat Dissipation: 38.5W (131.4 BTU/h)
• 1 10/100BASE-T out-of-band management port
Storage & Transportation Conditions • Power Consumption: 178W (607.4 BTU/h)
(Packaged)
• Transportation Temperature: -40° C to 70° C Physical Specifications
(- 40° F to 158° F) Dimensions and Weight Summit X150-24p
• Storage and Transportation Humidity: 60% to
95% RH, non-condensing
Height: 1.73 Inches/4.4 Cm General Specifications
Width: 17.35 Inches/44.1 Cm Performance
• Packaged Shock (Half Sine): 180 m/s2 (18g), Depth: 15.28 Inches/38.8 Cm • 8.8 Gbps switch fabric bandwidth
6ms, 600 shocks Weight: 12.06 lbs/5.48 Kg • 6.5 Mpps frame forwarding rate
• Packaged Sine Vibration: 5 – 62 Hz @ Velocity
EPS Dimensions and Weight • 9,216 Byte maximum packet size (Jumbo Frame)
5mm/s, 62 – 500 Hz @ 0.2 G
EPS-T • 13 load sharing trunks, up to 8 members per trunk
• Packaged Random Vibration: 5 – 20 Hz @ 1.0
Height: 1.75 Inches/4.4 Cm • 8 QoS queues/port
ASD w/-3dB/oct. from 20 – 200 Hz
Width: 17.4 Inches/44 Cm • 4,094 VLANs (Port, Protocol, IEEE 802.1Q)
• 14 drops min on sides & corners @ 42”(<15kg box)
Depth: 7.6 Inches/19.3 Cm • 1,024 centralized ACL rules per switch
Power & Acoustic Sound Forwarding Tables
• Voltage Input Range: 90 – 264V Nominal Input EPS-160
Height: 1.7 Inches/4.3 Cm • Layer 2/MAC Addresses: 8K
Ratings: 100 – 240V~, 50/60 Hz, 1.0A
Width: 7.4 Inches/18.8 Cm Rate Limiting
• Input Current: 0.5A @ 115V~ (lowline) 0.25A @
Depth: 7.9 Inches/20 Cm • Ingress bandwidth policing/rate limiting per flow
230V~ (high-line)
• Egress bandwidth rate limiting per egress queue
• Maximum In-Rush Current: 30A @115V/60 Hz,
• Rate Limiting Granularity: 64Kbps
Max Load Operating Specifications • Available Rate Limiters: 1,024 per switch
• Efficiency: 83% with 60% – 100% load
Temperature Indicators
• Line Frequency Range: 47 – 63 Hz
• Operating Temperature Range: 0° C to 40° C • Per port status LED including power status
• Power Supply Input Socket: IEC 320 C14
(32° F to 104° F) • System Status LEDs: management, fan and power
• Power Cord Input Plug: IEC 320 C13
• Operating Humidity: 10% to 93% relative
• Heat Dissipation: 36W (123 BTU/h)
humidity, non-condensing
• Power Consumption: 36W (123 BTU/h)
© 2007 Extreme Networks, Inc. All rights reserved. Summit X150 Series—Page 7
Extreme Networks Data Sheet
Technical Specifications
Ports External Power Supply – EPS-500 Telecom Standards
• 24 ports 10/100BASE-T with auto-speed and • Voltage Input Range: 90 – 264V • ETSI EN 300 386:2001 (EMC Telecommunica-
auto-polarity • Nominal Input Ratings: 100 – 240V~, 50 – 60 tions)
• 2 ports Gigabit Ethernet (SFP mini-GBIC, shared Hz, 10A • ETSI EN 300 019 (Environmental for Telecommu-
PHY with 2 10/100/1000BASE-T ports) • Line Frequency Range: 47 – 63 Hz nications)
• 1 port serial (console port) • Maximum Input Current: 5.75A at 115 VAC, • IEEE 802.3 Media Access Standards
• 1 10/100BASE-T out-of-band management port 2.80A at 230 VAC • IEEE 802.3ab 1000BASE-T
• Maximum Inrush Current: 30A at 115 VAC, 60A • IEEE 802.3z 1000BASE-X
at 230 VAC Environmental Standards
Physical Specifications • Output: -50 VDC, 7.5A max, 375 Watts 12 VDC, • EN/ETSI 300 019-2-1 v2.1.2 – Class 1.2 Storage
Dimensions and Weight 7.5A max, 90 Watts • EN/ETSI 300 019-2-2 v2.1.2 – Class 2.3
Height: 1.73 Inches/4.4 Cm • Power Supply Input Socket: IEC 320 C14 Transportation
Width: 17.35 Inches/44.1 Cm • Power Cord Input Plug: IEC 320 C13 • EN/ETSI 300 019-2-3 v2.2.2 – Class 3.1e
Depth: 12.13 Inches/30.8 Cm • Heat Dissipation: 125W (427 BTU/h) Operational
Weight: 12.1 Lbs/5.46 Kg • Power Consumption: 625W (2,133 BTU/h) • EN/ETSI 300 753 (1997-10) – Acoustic Noise
EPS Dimensions and Weight ASTM D3580 Random Vibration Unpackaged
EPS-500 1.5G
Height: 1.73 Inches/4.4 Cm Summit X150 Series
Width: 17.4 Inches/44 Cm
Depth: 7.6 Inches/19.3 Cm Regulatory/Safety Standards Warranty
Weight: 10.8 Lbs/4.9 Kg North American Safety of ITE • Limited Lifetime Hardware Warranty
• UL 60950-1:2003 1st Ed., Listed Device (U.S.) • 90-days on Software
• CSA 22.2#60950-1-03 1st Ed.(Canada)
Operating Specifications • Complies with FCC 21CFR 1040.10 (U.S. Laser
Temperature Safety)
• Operating Temperature Range: 0° C to 40° C • CDRH Letter of Approval (U.S. FDA Approval)
(32° F to 104° F) • IEEE 802.3af 6-2003 Environment A for PoE
• Operating Humidity: 10% to 93% relative Applications
humidity, non-condensing European Safety of ITE
• Operational Shock (Half Sine): 30 m/s2 (3g), • EN 60950-1+A11:2001 TUV-R GS Mark by
11ms, 60 Shocks German Notified Body
• Operational Random Vibration: 5 – 500 Hz @ • EN 60825-1+A2:2001 (Lasers Safety)
1.5g rms • 73/23/EEC Low Voltage Directive
Storage & Transportation Conditions (Packaged) • International Safety of ITE
• Transportation Temperature: -40° C to 70° C • CB Report & Certificate per IEC 60950-
(- 40° F to 158° F) 1:2001+All Country Deviations
• Storage and Transportation Humidity: 60% to • AS/NZS 60950-1 (Australia /New Zealand)
95% RH, non-condensing EMI/EMC Standards
• Packaged Shock (Half Sine): 180 m/s2 (18g), North America EMC for ITE
6ms, 600 shocks • FCC CFR 47 part 15 Class A (U.S.A.)
• Packaged Sine Vibration: 5 – 62 Hz @ Velocity • ICES-003 Class A (Canada)
5mm/s, 62 – 500 Hz @ 0.2 G
European EMC standards
• Packaged Random Vibration: 5 – 20 Hz @ 1.0
• EN 55022+A2:2003 Class A
ASD w/-3dB/oct. from 20 – 200 Hz
• EN 55024+A2:2003 Class A includes IEC
• 14 drops min on sides & corners @ 42”
61000-4- 2, 3, 4, 5, 6, 11
(<15kg box)
• EN 61000-3-2,3 (Harmonics & Flicker)
Power & Acoustic Sound • ETSI EN 300 386:2001 (EMC Telecommunica-
• Voltage Input Range: 90 – 264V tions)
• Nominal Input Ratings: 100 – 240V~, • 89/336/EEC EMC Directive
50/60 Hz, 5.5A
International EMC Certifications
• Input Current (with PoE full load): 4.4A @ 115V~
• CISPR 22:1997 Class A (International Emis-
(lowline) 2.2A @ 230V~ (high-line)
sions)
• Input Current (without PoE): 0.75A @ 115V~
• CISPR 24:1997 Class A (International Immunity)
(lowline) 0.5A @ 230V~ (high-line)
• IEC/EN 61000-4-2 Electrostatic Discharge, 8kV
• Maximum In-Rush Current: 30A @115V/60 Hz,
Contact, 15kV Air, Criteria A
Max Load
• IEC/EN 61000-4-3 Radiated Immunity 10V/m,
• Efficiency: 81% with 60% – 100% load
Criteria A
• Line Frequency Range: 47 – 63 Hz
• IEC/EN 61000-4-4 Transient Burst, 1kV, Criteria A
• Nominal Frequency Range: 50 – 60 Hz
• IEC/EN 61000-4-5 Surge, 2kV L-L, 2kV L-G,
• Power Supply Input Socket: IEC 320 C14
Level 3, Criteria A
• Power Cord Input Plug: IEC 320 C13
• IEC/EN 61000-4-6 Conducted Immunity, 0.15 –
• Heat Dissipation (with PoE full load): 100W
80MHz, 10V/m unmod. RMS, Criteria A
(341BTU/h)
• IEC/EN 61000-4-11 Power Dips & Interruptions,
• Power Consumption (with PoE full load): 470W
>30%, 25 periods, Criteria C
(1604 BTU/h)
• Heat Dissipation (without PoE): 55W (188 BTU/h) Country Specific
• Power Consumption (without PoE): 55W (188 • VCCI Class A (Japan Emissions)
BTU/h) • AS/NZS 3548 ACA (Australia Emissions)
• Acoustic Noise (Low FAN Speed): 39 dBA per • CNS 13438:1997 Class A (BSMI-Taiwan)
ISO 7779 • MIC Mark, EMC Approval (Korea)
• Acoustic Noise (High FAN Speed): 44 dBA per
ISO 7779
© 2007 Extreme Networks, Inc. All rights reserved. Summit X150 Series—Page 8
Extreme Networks Data Sheet
Accessories
EPS-500
Summit Switch
Summit Switch Models Part Number(s) External Redundant PSU options
Summit X150-24t 15201 EPS-160 power module (10907) with EPS-T (10906)
Summit X150-48t 15203 EPS-160 power module (10907) with EPS-T (10906)
Summit X150-24p 15205 EPS-500 external power supply (10911)
© 2007 Extreme Networks, Inc. All rights reserved. Summit X150 Series—Page 9
Extreme Networks Data Sheet
Ordering Information
Part
Number Name Description
15201 Summit X150-24t 24 10/100BASE-TX, 2 gigabit combo ports (2 unpopulated gigabit SFP and
10/100/1000BASE-T), ExtremeXOS Layer 2 Edge License, 1 AC PSU, connector
for EPS-160 external redundant PSU
15203 Summit X150-48t 48 10/100BASE-TX, 2 gigabit combo ports (2 unpopulated gigabit SFP and
10/100/1000BASE-T), ExtremeXOS Layer 2 Edge License, 1 AC PSU, connector
for EPS-160 external redundant PSU
15205 Summit X150-24p 24 10/100BASE-TX with PoE, 2 gigabit combo ports (2 unpopulated gigabit SFP
and 10/100/1000BASE-T), ExtremeXOS Layer 2 Edge License, 1 AC PSU,
connector for EPS-500 external redundant PSU
10906 EPS-T1 External Power System power tray. Accepts up to two EPS-160 power modules
1
10907 EPS-160 External Power System power module for EPS-T, 160 Watts, with cable
10911 EPS-500 External AC PSU2 External Power System 500 Watts, with cable
1
Compatible with Summit X150-24t, Summit X150-48t
2
Compatible with Summit X150-24p
3
Future Support