The 12V power supply cable must be connected correctly. If the electronic damage
caused by the faulty operation of connection, the warranty would not cover it.
While connecting the cable, please notice the slot corresponding to the buckle as below.
Demonstration as below:
The power control wire is with 3pin of red, black and yellow.
Fan power supply wire is with 4pin of green, yellow, red and black.
1.1.4 Data wire
The 12V power supply cable must be connected correctly. Or the Faulty operation
of connection might cause the electronic damage to the PCBA.
Inspect all wires connection, check if the wires are connected stably and perfectly.
2. Configuration
While carrying or moving a miner, please don’t lift through on any wire.
2.1 Device preparation
1 PC 1 Configuration
Miner Power
2 1 Power supplement
Supply
Build
Network Communication Ethernet
3 1
Switch between PC and available
miners
1. Assing IPs to
DHCP/NTP Miners are set
miners.
4 server or 1 as dynamic IPs
2. Offer the NTP
Router acquire
timing
Miner IPs Default setting is dynamic acquirement, so the Mine field must be collocated
with DHCP server or the router with enable dynamic IPs acquirement function. Also the
NTP server is required for acceleration of NTP acquirement.
3. Inspection
1) Notice the Warning tape by the side of the machine, before power on, try the shake
the miner to ensure no Fans or pieces drop down inside.
2) Inspect all the connection cable, they must be adapted by respective port, connected
correctly and tightly enough.
Note: 1. The 12V cable must be adapted with the port, any reverse connection may
cause short and burn out the chip, which would not be in the warranty.
2. Power control cable (three wire) must be connected well, or might cause the
error to control the power supply, leading to the low hashrate.
3. Connect the Fan cable securely to ensure the working condition of the miner.
4. Miner configuration.
Note: 1. If the lights are all off, please check the connection of cables.
2. If the Green or the network wire Indicator light is off, please check about the
network switch, network wire connection or any bad wire.
3. Whatsminer tools acquires the IPs only with the miner connected in a same
network segment.
4. If the software still doesn’t acquire the IPs, please press the “reset” key over 5s,
reboot the machine and warm up 30s, press IPFOUND bottom over 5s.
5. If the software acquire the IP address automatically without your any action(with
5s long press IPFOUND bottom), the IPFOUND bottom might be held pressing somehow.
1. Access the IP with browser, logon with default username, password(root). Choose:
Configuration->Interface, then you can edit the LAN configuration. Select the Static
Address bar and press “Switch protocol”.
After the configuration, only static IP could access the configuration interface.
3) Restart the CGminer program and check if the setting was effective.
Choose: Status->CGMinerStatus, you can see the status.
After 30s rebooting the control board, the page will refresh back to the Logon interface.
5. Miner’s running status
Choose: Status->CGMiner Status,
Note: 1) The miner will test run for 15min. Before that, the hashrate is not effective.
The test run is still proceeding, the hashrate will be lower than the normal level.
2) If the Temperature/Fan-speed is higher that 85℃/6000rpm, the miner
controller IC would reduce the frequency of processing unit, the hashrate will come
down meanwhile. You need ensure the good work condition, such as no more than
40℃ room temperature, good ventilation.
3) If the Fan wire was not installed correctly, bad ventilation might cause the
higher temperature and lower hashrate.
4) If the data was not shown correctly with the “Effective chips” and
“Temperature” on the Status interface, please power off the miner and inspect all
the wire connection status.