You are on page 1of 1
Deno Compressors B.V. — van der Giessenweg 49 EZ deno Compressors SE The Netheriands T +31 180.442 288, F +31 180 522 222 E info@denocomp.ni ywew.denocomp.n Colombo Dockyard PLC Graving Docks, Port of Colombo P.O. Box 906, Colombo 15 Sti Lanka Fax, : 494-11-2523 165 / 2345 863 Ref: Settings for starting and service air compressor. NC222, NC223, NC224 Dear Mr. / Mrs. We, DENO compressors, herewith confirm the following settings and recommendations for supplied equipment. Starting air compressor ; Safety valve relief pressure set point Stage 1 / 8bar - Stage 2/ 32bar Pressure switches are not set, recommended setting, compr. 1 start 27 / stop 29, ‘compressor 2 start 26 / stop 28. High temp alarm setting is not set, recommend setting is 85C Service air compressor ; Safety valve relief pressure set point 1bar Auto start/stop pressure settings, start 6 Sbar / stop 8bar (adjustable) High temp alarm setting 95C Please contact us if you have questions remarks: Kind regards, ¢ Denni Kuhn