Professional Documents
Culture Documents
Chromatography
Systems
Page
Liquid Chromatographs 8-19
Gas Chromatographs 20-23
Mass Spectrometry
Systems
Spectroscopy Systems
UV-VIS Spectrophotometers 39
UV-VIS-NIR Spectrophotometers / Spectrofluorophotometers FTIR 40
Spectrophotometers 41-42
Atomic Absorption Spectrophotometers / Optical Emission Spectrometers ICP 43
Emission Spectrometers 44
Protein Sequencer 45
Microchip Electrophoresis System 45
Cell Culture Media Analysis Platform 45
Molecular Imaging Instruments 46
Environmental
Measurement Systems
TOC Analyzers
52-54
Transportable Gas Analyzers
55
Stationery Gas Analyzers
56
Physical Properties
Measurement Systems
Pharmacokinetics,
Metabolomics, Safety PK/TK ADME HPLC, LCMS, Imaging mass microscope
Discovery
Pharmaceuticals (Low-molecular, Bio)
Pharmacokinetics, Metabolomics, Safety
Manufacturing
Headspace Analysis System P.33 i-Series Plus P.8 TOC-L P.52 Aggregates Sizer P.68
GC and GC-MS Application System High-Performance Total Organic Aggregation Analysis System
Liquid Chromatograph Carbon Analyzer for Biopharmaceuticals
4
Evaluation Instruments for Foods
Test instruments for food and materials
Foreign substances and odor FTIR, EDX, GC, GCMS, X-Ray Inspection System
Food texture, taste Particle size Analyzer, Thermal analyzers, Moisture analyzers
Food Development
(Functional Foods Flavor GC, GCMS
and Supplements)
Functionality HPLC, LCMS, GC, GCMS
GCMS-TQ8050 P. 32 LABNIRS P. 46
Gas Chromatograph Functional Near-Infrared EZ-X Series P. 57
Triple Quadrupole Mass Spectrometer Spectroscopy System for Research Compact Tabletop Tester
5
Instruments for Life Science Research
Delivering new technology for life science
MALDI-TOFMS, LCMS-IT-TOF,
Post-translational
Trace-level oligosaccharide rapid analysis system,
modifications analysis
nano-LC, AccuSpot, Cell-free protein synthesis reagent kit
Proteomics Structural analysis LC-MS/MS
N-terminal amino acid
Protein sequencing systems, MALDI-TOFMS
sequencing analysis
Marker discovery MALDI-TOFMS, LC-MS/MS, nano-LC, AccuSpot
Marker discovery GCMS, LC-MS/MS, iMScope TRIO
Metabolomics
Metabolite analysis GCMS, HPLC (Nexera), LCMS
In vitro imaging MALDI-TOFMS, iMScope TRIO, iMLayer, EPMA
Imaging
Optical brain-function imaging LIGHTNIRS, LABNIRS
Genomics
Proteomics
Metabolomics
Imaging
PPSQ-51A/53A P.45
High Performance Liquid Chromatograph Matrix-Assisted Protein Sequencer
Ion-trap Time-of-flight Mass Spectrometer Laser Desorption/Ionization
Time-of-Flight Mass Spectrometer
6
Evaluation Instruments for Renewable Energy Applications
Evaluation instruments for renewable enegy
Fuel Cells Membrane electrode assemblies (MEA) EPMA, X-Ray Inspection System
(Solid PEFC)
Electrolytes Thermal analyzers, SPM, Micro Vickers Hardness Tester, Tensile Tester, Fatigue Tester
Electrolyte membrane degradation components in generated water Ion chromatograph, LCMS
Algal Biomass
Photocatalysts and Artificial Photosynthesis
Fuel Cells
Energy Carriers
7
TOC Analyzers
The role of the TOC analyzer is to quickly and reliably measure all sorts of
organic compounds in water. The most important feature of such an analyzer
is its ability to efficiently oxidize not only easily-decomposed, low-molecular-
weight organic compounds, but also hard-to-decompose insoluble and
macromolecular organic compounds. A new series of Shimadzu TOC
analyzers has been released, which delivers both high-efficiency detection of
organic compounds via the 680°C combustion catalytic oxidation method,
and high sensitivity capable of even pure water management.
High-sensitivity model Standard model
Model TOC-LCPH TOC-LCSH TOC-LCPN TOC-LCSN
Operation method PC-controlled Standalone PC-controlled Standalone
680°C combustion catalytic oxidation – non-dispersive
Measurement method
infrared detection (NDIR) method This product conforms to Shimadzu’s Eco-labeled designation.
Measurement items TO, IC, TOC, NPOC (Optional: POC, TN) * Energy consumption has been reduced by 36% in comparison with
Measurement TC 0 to 30,000 mg/L 0 to 30,000 mg/L conventional Shimadzu models.
range IC 0 to 35,000 mg/L 0 to 3,000 mg/L
Detection limit 4 μg/L 50 μg/L
52
TOC Analyzers
Combination with the TOC-L series results in a fully automatic Combination with the TOC-L series results in an automatic
Spectroscopy Systems
measurement system. measurement system at an affordable price.
Vials with three different capacities, 9 mL, 24 mL, and 40 mL, can be Settings are extremely simple, since special vials are not required. In
used. addition, the effects of contamination can be reduced if
• Vials with a septum can be used (24 mL and 40 mL vials). measurements are performed as is using large-capacity collection
• Can be equipped with a magnetic stirrer (optional).
bottles.
9 mL × 93 vials
• Can be combined with commercially-available stirrers and water baths.
Types and number of vials 24 mL × 93 vials
40 mL × 68 vials Units connected Up to 2 units can be connected.
8 vials per unit
TN (Total Nitrogen) Unit for TOC-L Series Solid Sample Combustion Unit for TOC-L Series
Systems
Measurement Systems
Environmental
Material Testing and Non-Destructive
SSM-5000A
Combination with the TOC-L series results in a simultaneous TOC When combined with the TOC-L series, TC, IC, and TOC Inspection Systems
and TN measurement system. measurements can be performed in soil, sludge, sedimentation, and
This system can also be used to meet regulations on effluent other solid samples.
nitrogen and total volume. In addition, with GMP cleaning validation, the system can also be
The space-saving design enables installation above the TOC-L, used to evaluate residues using the swab sampling/direct combustion
meaning that installation space is not a problem when expanding. carbon analysis method.
• Can also be connected to the TOC-V series
Measurement Systems