You are on page 1of 9

Typical Wind Load - 4 kPa for the whole building

Stiffener details 21x48 C-Channel bended A36 Steel Plate Middle Wall Side
Largest (thickness will be the variable)
Tributary Height, Number of
Item Windows U-channel U-channel Location of Support Remarks
Width, mm Supports
Mullions at Mullions at Fixed Wall Side Bracket Bolt Requirement Bracket Bolt Requirement
mm Header & Sill Transom
Handle Side Glass Panel Mullions Length, mm FS: 1.5 only Length, mm FS: 1.5 only
FS: 1.5 only FS: 1.5 only

2p cs. M8- 8.8 @175mm O C


AW-24 897.5 1400 2mm THK N/A No need 2mm THK N/A 250 125
with 60mm embedment depth Long Side:
1 at Wall Side (150mm offset), Long Side means:
2p cs. M8- 8.8 @175mm O C 3 support s Side with 2 Fixed Glass Panels
AW-21 882.5 1400 2mm THK N/A No need 2mm THK N/A 250 125 1 at Middle,
with 60mm embedment depth 1p c. M8- 8.8 with at Long Side and 2 Operable Panels
1 at Corner (150mm offset)
1 60mm embedment &
2p cs. M8- 8.8 @175mm O C depth 2 support s Short Side means:
AW-25 852.5 1400 2mm THK N/A No need 2mm THK N/A 250 125 Short Side:
with 60mm embedment depth at Short Side Side with 1 Fixed Glass Panel and
1 at Wall Side (150mm offset),
1 Operable Panel
2p cs. M8- 8.8 @175mm O C 1 at Corner (150mm offset)
AW-26 867.5 1400 2mm THK N/A No need 2mm THK N/A 250 125
with 60mm embedment depth

2p cs. M8- 8.8 @60mm O C with 1 at Wall Side (150mm offset),


AW-20 1255 1400 2mm THK 4mm THK No need No need N/A 100 50 4 -
60mm embedment depth 1 at center of Fixed Glass Panel

2p cs. M8- 8.8 @60mm O C with 4 equal length supports, consider


AW-21A 1082.5 1400 4mm THK N/A No need No need N/A 100 50 4 -
60mm embedment depth 150mm offset at Wall Side

1p c. M8- 8.8 with 1 at Wall Side (150mm offset),


AW-19 847.5 1400 2mm THK N/A No need No need N/A 100 50 3 -
90mm embedment depth 1 at Middle

1p c. M8- 8.8 with 1 at Wall Side (150mm offset),


AW-22 747.5 1400 *Same as above N/A No need No need N/A 100 50 3 -
90mm embedment depth 1 at Middle
1p c. M8- 8.8 with
1p c. M8- 8.8 with 1 at Wall Side (150mm offset),
2 AW-27 697.5 1400 *Same as above N/A No need No need N/A 100 50 60mm embedment 3 -
90mm embedment depth
depth
1 at Middle

1p c. M8- 8.8 with 1 at Wall Side (150mm offset),


AW-30 572.5 1400 *Same as above N/A No need No need N/A 100 50 3 -
90mm embedment depth 1 at Middle

1p c. M8- 8.8 with 1 at Wall Side (150mm offset),


AW-18A 522.5 1400 *Same as above N/A No need No need N/A 100 50 3 -
90mm embedment depth 1 at Middle

2p cs. M8- 8.8 @60mm O C with 4 equal length supports, consider


AW-28 1240 1400 N/A 4mm THK 2mm THK No need 2mm THK 100 50 4 -
60mm embedment depth 150mm offset at Wall Side

1p c. M8- 8.8 with 1 at Wall Side (150mm offset),


AW-23 640 1400 N/A N/A 2mm THK No need 2mm THK 100 50 3 -
90mm embedment depth 1 at Middle

AW-18 665 1400 No need No need No need No need N/A N/A N/A 75 2 -

1p c. M8- 8.8 with


3 AW-32 465 1400 No need No need No need No need N/A N/A N/A 75 60mm embedment 2 1 at Wall Side (150mm offset) -
depth

AW-32A 622.5 1400 No need No need No need No need N/A N/A N/A 75 2 -
Wind Load - 5 kPa (Special detail)

Stiffener details 21x48 C-Channel bended A36 Steel Plate Middle Wall Side
Largest (thickness will be the variable)
Tributary Height, Number of
Item Windows U-channel U-channel Location of Support Remarks
Width, mm Supports
Mullions at Mullions at Fixed Wall Side Bracket Bolt Requirement Bracket Bolt Requirement
mm Header & Sill Transom
Handle Side Glass Panel Mullions Length, mm FS: 1.5 only Length, mm FS: 1.5 only
FS: 1.5 only FS: 1.5 only

Long Side:
1 at Wall Side (150mm offset), Long Side means:
AW-24 897.5 1400 3 support s Side with 2 Fixed Glass Panels
1 at Middle,
1p c. M8- 8.8 with at Long Side and 2 Operable Panels
3p cs. M8- 8.8 @130mm O C 1 at Corner (150mm offset)
1 2mm THK N/A No need 4mm THK N/A 350 125 110mm &
with 60mm embedment depth
embedment depth 2 support s Short Side means:
Short Side:
AW-26 867.5 1400 at Short Side Side with 1 Fixed Glass Panel and
1 at Wall Side (150mm offset),
1 Operable Panel
1 at Corner (150mm offset)

*Please see locat ion of windows suject ed t o 5 kPa loading and t he infographic of support locat ion on t he following pages.
Highlighting location of AW-24 subjected to 5 kPa loading at 20F – 36F, and
AW-26 subjected to 5 kPa loading at 20F – 33F.
LONG SIDE
SHORT SIDE
1 at Wall Side (150mm offset),
1 at Wall Side (150mm offset),
1 at Middle,
1 at Corner (150mm offset)
1 at Corner (150mm offset)

1
1 at Wall Side (150mm offset),
1 at center of Fixed Glass Panel

2 4 equal length of supports,


consider 150mm offset at Wall
Side

1 at Wall Side (150mm offset),


1 at center of Fixed Glass Panel

3 1 at Wall Side (150mm offset)


For Punch Windows AW-31

For Punch Windows AW-29, AW-44

D D

For Punch Window, AW-45, NO STIFFENER NEEDED, INTERIOR WINDOW.


20.00
20.00

D
For Middle Mullion

For Wall Side Mullion

You might also like