You are on page 1of 1
SCOT+ Series Circuit Breaker Time Interval Meter SCOPE introduces its next generation of iconic SCOT Series Circuit Breaker Time Interval Meters in all new super light avatars, bused on cutting edge microcontroller & embedded technology. User can choose trom two modals, SCOT M3K" and SCOT MXP+ depending on type of testing to be done on circuit breakers. Features © Aradically new design makes SCOT the lightest available CB Time Interval Meter. High sampling frequency of upto 10 KHz offers high timing resolution of 0.1 mS. Mains as well as rechargeable Liion battery operated. In built battery monitor and cut off circuit for protection against battery deep discharge. © In buill real time clock, memory and printer’. Test time stamping on each record enables time references for future use. © PC Downloading & Anolysis including ‘Trend Analysis’ is possible with “CData SCOT” Software supplied with kit. Instrument debug options like contact status check, command check, memory check, printer check, PC downloading check are provided Simple operation. Tests can be conducted even by technicians. Supplicd with rugged lost lead set, suitable fer testing FHV Cs. ee Enclosed in ultra rugged P67 class hard molded case. . The instrument is supplied with CData software CD, Calibration Certificate, and Test leads suitable for testing of EHV class circuit broakers. Type Tested as per IEC 60068, IEC 61326 & IEC 61010-1. CE marked fe eae 2 Note: * - These features are available only in SCOT MXP+. cPERATION: U8 yh Ni Specifications Parameter SCOT M3K+ ‘SCOT MXxP+ 12 ( Upto 2 Main = 2 PIR contacts per pole, 3 poles simultaneously, Le. 6 Main 6 PIR contacis simultaneously) 3 (Main contacts of 5 poles connected end to Contact Timing Channels aoe alniencousn Sampling Speed OKC, 5kC, 2kC,1kC & 100C, Selectable Timing Range ‘Sec, 2Sec, SSec, 10Sec & 100Sec respectively for above Sampling Speeds Resolution 0.1 mSec, 0.2 mSec, 0.5 mSec, 1 mSec & 10 mSec respectively for above Sampling Speeds Accuracy Value = 0.05% + 1 digit Breaker Control Two solid state contacts rated at 354, 300V AC/DC for breaker operation Trigger Options Close, Open, Close-Open Display 4 Line X 20 character backlit LCD Printer In-built, 88 mm thermal printer (Available only in SCOPT MXP) Keypad 5 keys Memory 1 MB, 100 records, Internal Inbuilt Battery Lifon, 17.1 V, 4h Battery Charger Input Supply - 100 to 300 VAC, 50/60 Hz + 10% Output Voltage - 13.5 VDC, 1000 mA Communication Port usB Soitware CDala SCOT - For PC Downloading & Analysis, Windows based Environment 0 to 50°C, Upto 95% RH (Non condensing) Dimensions 300 x 250 x 200 rm Instrument Weight Skg

You might also like