MBER. wwe Fas os _Aabpltal—al clio x= Qatar General ae & Water Corporation ELECTRICITY PROJECTS (TECHNICAL AFFAIRS) GTC-371B/2010 Qatar Power Transmission System Expansion PHASE-10 Ref.NoPH10-371B-KM-DTA-13-2860-0 [Total Pages: 1+] DOCUMENT TRANSMITTAL ADVICE ae To: [approved (asue 88 IFC") lA Siemens AG and Siemens WLL Consortium |B |Arrroved xcortas toed Mohamed Abdul Kather (sev as IFC" with ncorprated comments) 4974.44 56 03 78 fo [peers Een! a Noted & Resubrit From: [>__[Not Approved Abdulla Mubarak Saad A! Hajri EAs Built Head of Electricity Projects FF [Fer twormaton KAHRAMAA io [Suresoaes ce: IK [see Remark Lahmeyer international [Cote Staned Dosunen fom KM Otice Andreas Seckel o [Rejected +974 44 86 60 89 | IFG= issues Fox Gonstacon S6/11KV Doha Industrial F (DIF) GIS PRIOSE-1BOTS 1 be induatal-F G6 SubetaionOuoor 1 | se PROSE TBOTS © purospacszons | 0 [Posy 8 TERENS WLL - SIEMENS AG| Signed ethan (aaa Mubarak Saad Al Halt Head of Electricity Projects Reviewer tae Po. Pa o Toles above Cormapi® andor prev donot lave he Cntr te obgton nthe Contato ensure confemance to the Spooiieations. Af Speciation deviations four! subsequent fo approval are fo be corected by the Conracor to the salafaton ofthe KahramaaiEngineer Tek: (974) 4484 5196) - Fax: (974) 4484 5191 PO BOX 41, DOHA - QATAR. Gesceerer var Bunn ules ileal INTERNATIONAL sho -ch Qatar General Electricity & Water Corporation [DTS _PH10-SIE-1B-DTS.19.2860 2018-03-08, [DTA PH10.3718-K¥-DTA13-2860-0 No _|Document_Rev/ Apr Description lPH10-16.34.62.0311.0 / 8 [Doha Indusital -F 6871 7RV Substation Outdoor Earthing Layout No_|Comments Contractors Reply [Earthing in Transformer Rooms with ceference to Tender Documentation, Volume 3, 'Section 3.3.9 inside of Transformer Rooms should be [provided adequate Copper Bars according to the next \descrption: "Size of the bus bar shall be a minimum of 70xt0rnm. Length, clamping arrangement and |connections shail he adequate enough to withstand the forces due mechanical and electical stresses in the lneutral path during faut conditions. Mounting arrangement shai! be submitted for review and approval |All materials shall be protected against corrosion” Please proceed appropriately. NER Earthing [Presse rote that each NER should be earthed at east ai two points. 3| Conditional Approval HThe Approval, given to this document is condltional and does not rofeve the contractor of his lwabitias/obiigations related to Numerical Calculation Results and Referonce Performances accepted tothe related matters. Contractor undertakes ail responsteilies for any occurrence wich could arise ae consequence of wrongly used calculation by |AUTOGRID PRO SYSTEM,

You might also like