You are on page 1of 8

Cat. No.

KV300WIN-KA-C

KV-300 Series
Super Micro PLC

The Expert Solution

● Simplified wiring
Unmatched flexibility for
significant cost & time savings

● Ladder Builder for KV software


creates sequence
programs in Windows®
Complex wiring problems?
Try the Keyence Solution.
The 2-wire KV I/O Distribution System ensures
simple, flexible system configurations

KV-U5 Power KV-300 KV-R1A I/O


Distribution CPU Distribution
Module Complex wiring like this is now a thing of the past.
Module

The problem: Even in small systems of only 20 or 30 I/Os, wiring can be a


headache – between the PLC and terminal blocks in the control panel, at local sites,
and at each I/O device. And it gets worse every time you change the program, layout
arrangement, or I/O devices.

The Keyence Solution: The new KV I/O Distribution System requires only
two wires for all wiring between the PLC and each I/O. Plus, it eliminates the intermedi-
ate terminal blocks used in conventional systems. What's more, its fast – you can ex-
pect scan times of close to 0.5 ms, even with the maximum of 1774 I/Os.

It's easy to create the exact con-


figuration for any site with our
wide selection of I/O terminal
modules – including 8- and 16-
Flexibility for rapid point input and output modules.
reconfiguration. With only
two wires (plus the power
supply line), the KV Flex- KV-R8R/R8T/R8X I/O Terminal Modules
ible Branch Wiring
method allows you to ar-
range I/O devices in any
order. Also, you can
branch the wiring at any
position desired for
greater convenience and
economy. And there's no
need for the terminating
required by conventional
systems.

KV-R16R/R16T/R16X I/O Terminal Modules

The KEYENCE I/O Distribution System


It's the most versatile system available today. Here's why.
Compact control panel KV-R1A I/O Distribution Flexible Branch Wiring
Even at the maximum I/O configura- Modules (11 maximum) The unique KV I/O distribution
tion, your control panel contains no system allows branching of any I/
more than these 13 compact modules. O terminal module at any point.
There's no need to consider mod-
Up to 1774 I/Os ule order or terminating for I/O
A single CPU can control up to 11 KV- modules. Simplified wiring makes
R1A I/O distribution modules, each of retrofitting of modules a snap.
which can control up to 10 I/O termi-
nal modules of up to 16 I/O points each Simple I/O Addressing
– for a maximum of 1760 I/O points (16 I/O addressing in programs is
x 10 x 11). Include the 14 I/Os built into simple and easy, even when you
the CPU, and you have up to 1774 I/O combine multiple I/O terminal
points at your disposal. modules and ordinary I/O devices.
No special commands or ad-
KV Quick Scans of 0.5 ms dresses are required. You can also
The KV Quick Scan method controls change the I/O layout with ease,
all I/Os with a fast 0.5-ms scan time, without the tedious re-editing of I/
overcoming the scan-time delays of O addresses that conventional Unlimited branching for versatility
conventional wire-saving systems. systems require.

2
The Flexibility for Brand M

Any Configuration 130


110 90 KV300 Brand O
SYSTEM

Compact 178.3
Keyence systems are one-third the volume and require only one- 260
half the footprint of conventional units. So control panels are 379
smaller and wiring space is significantly reduced.

New Modular Design Keyence components set new standards for compact design.
Keyence's original modular de-
sign allows easy mounting on a
DIN rail and employs a quick-dis-
connect lock mechanism. No ad-
ditional rack or base is required
when extending the system con- Connector I/O Modules
figuration. Our expansion connector I/O module (only 14 mm thick)
can be added to the CPU. It is available in five models,
including 16-inputs or 16-outputs (Triac/Relay), and 32-
inputs or 32-outputs (Transistor).

KV-U5 KV-U4 KV-300 KV-R1A I/O KV-L2 KV-AN6 KV-C32T KV-B16R


DC Power AC Power CPU Distribution Serial Analog I/O KV-B16S
Distribution Supply Module Module Interface Module
Module Module
KV-C16X
Connector I/O Module

Versatile KV-AN6 Analog I/O Module KV-L2 Serial Interface Module


Keyence now offers both A/D and D/A functions in a single module. This module has two ports – an RS-232C port and a switchable RS-
This versatile unit can output analog 232C/RS-422A port – for serial communications between PLCs or
data from Keyence sensors and other between a PLC and computer. This setup makes it easy to control
measuring instruments for direct in- Ultrasonic and read data from any external instrument with a compatible serial
Displacement
put into a PLC. In addition, it enables Sensor port.
UD-500
analog output from a PLC to control As well, a single com-
such variables as the motor speed of puter running Keyence's 300

line equipment. KV
Ladder Builder for KV L2
U4
CPU can communicate with
In this example, a Keyence sensor multiple CPUs to edit
measures sheet thickness for control- programs and monitor
ling the speed of an extruder motor. operation.
What's more, a computer
can monitor a CPU while
communicating with an-
other computer through
the serial port. RS-232C RS-422A
And thanks to the built- KV KV KV
in Display Interface
Mode, you can easily 300
L2
connect a commercially
KV KV
available display unit to
the CPU.

Create a wide variety of system configurations with Keyence Analog Sensors,


RD Series Analog Sensor Controllers, and KV Series PLCs
3
Slow, tedious debugging?
Try the Keyence Solution.
Ladder Builder ensures fast, easy programming
and efficient desktop debugging.

The problem: Installation problems are inevitable when ma- The Keyence Solution: With Ladder Builder Software,
chinery, control panels, and PLC programs are developed indepen- you save programming and debugging time. Our original Desktop
dently. Complicated, time-consuming rewiring, machinery readjust- Simulator feature lets you check program operation in advance –
ment, and reprogramming are unavoidable. Even worse, on-site de- without first connecting to machinery, I/O devices, or even a PLC. By
bugging becomes slow and labor-intensive, because the program verifying your program on computer, you can troubleshoot problems
can't be seen. The result is delayed production and increased cost before installation, avoiding tedious rewiring and adjustment on-site.
pressures.

New Windows-compatible Ladder


Builder available!
User-friendly operation and
high-level programming ca-
pabilities make Ladder
Builder for KV ideal for be-
ginners and experienced
programmers alike.

Simulate Without PLC


Our new Desktop Simulator lets
you simulate a program in operation
before you connect your PLC.
4
The Easiest Programming Ever
Simulator
Quick debugging without a PLC
Even without a PLC connected, Ladder Builder for KV can simulate
program execution. The execution can be checked without transferring
the program to the PLC. By providing a single step execution function
(forward or reverse) in addition to a regular scan execution function,
debugging efficiency is increased.

Forward/reverse single step execution


You can easily find a problem in complex operations by
checking the operation process by one step at a time.

Monitor All Function


Timers, counters and data memories can be checked
simultaneously in multiple windows. For effective debug-
ging, you can check multiple devices at one time which
don’t directly appear in the ladder diagram.

Registration Monitor
Ladder Builder for KV can display multiple timing charts
of devices simultaneously. This enables convenient
checking of all element on/off timing.

Ladder Simulator enables direct checking of


the ladder diagram execution
By clicking an element in the ladder diagram, the simu-
lator screen quickly appears which allows element set-
ting/resetting.

Monitor
Real time monitoring without stopping the machine
Ladder diagram and element on/off status can be monitored real time.
Timing charts can be monitored simultaneously.

Editor
Easy editing using Windows® functions

Instruction selection window


The user-friendly design allows data entry from a key- UNDO function
board or mouse. You can select and specify a device Ladder Builder for KV enables
or command from a list provided by device type. Usage list efficient editing. If you acciden-
This ensures error-free entry of target symbols. For When creating ladder diagrams, it can be difficult to tally delete an instruction, you
fast programming, you can also enter the symbol di- keep track of addresses already used. The usage can undo the action simply by
rectly by typing the command from the keyboard. list displays which ones are used/available. clicking the “Undo” button.
"Redo" button cancels "Undo".
Multi-file editing
MS-DOS version is
Multiple files can be edited
small enough for any
simultaneously on Ladder
computer configura-
Builder for KV. You can
tion
freely cut and paste from
Incrediware
one file to another.
Auto-save function [KV-H4E for MS-DOS]
Ladder Builder for KV automatically backs up your MS-DOS version is also avail-
able with very simple operation
program at predetermined intervals. This protects your and real-time monitoring.
data from being lost due to a PC power loss or sys-
tem crash.
5
Summary
System configuration Module list

Model Model name Remarks


External devices
KV-300 CPU Number of steps: 8000, Inputs: 10, Outputs: 4
Personal External PLC
computer display device (KV-10/80 series, etc.) KV-U4 AC Power Supply Module Input supply voltage: 100 to 240 VAC,
Output voltage: 24 VDC, Output current: 1.4 A
I/O modules Special modules KV-U5 DC Power Distribution Module Input supply voltage: 24 VDC,
Connector I/O modules KV-AN6 KV-L2 Serial Maximum current: 3.5 A
KV-C16X I/O module (16 Input) Analog I/O interface
module module KV-C16X Connector Input Module Input mode: 24 VDC/5 VDC switchable,
KV-C32X I/O module (32 Input) Inputs: 16
KV-B16R I/O module (16 Relay-Output)
KV-C32X Connector Input Module Input mode: 24 VDC/5 VDC switchable,
KV-B16S I/O module (16 Triac-Output) Analog Serial Inputs: 32
KV-C32T I/O module (32 Transistor-Output) I/O devices I/O devices
KV-B16R Output Module (Relay) Rated load: 250 VAC/30 VDC 2 A
CPU
(8 A per common), Outputs: 16,
KV-300
KV-R1A I/O Distribution module Connection: terminal block
KV-B16S Output Module (Triac) Rated load: 250 VAC 0.3 A (1.2 A per common
I/O terminal modules
with surge voltage protection), Outputs: 16,
KV-R8X I/O terminal module (8 Input) Connection: terminal block
Power
KV-R8R I/O terminal module (8 Relay-Output)
supply KV-C32T Connector Output Module Rated load: 30 VDC 0.2 A,
KV-R8T I/O terminal module (8 Transistor-Output)
KV-U4 (Transistor) Output: 32
KV-R16X I/O terminal module (16 Input)
AC power KV-R1A I/O Distribution Module Max. number of I/O terminal modules: 5 input
KV-R16R I/O terminal module (16 Relay-Output)
supply terminals and 5 output terminals
module KV-R16T I/O terminal module (16 Transistor-Output)
KV-R8X I/O Terminal Module (Input) Input voltage: 24 VDC, Inputs: 8,
KV-U5 Connection: terminal block
DC power Peripherals
distribution KV-R16X I/O Terminal Module (Input) Input voltage: 24 VDC, Inputs: 16,
IBM PC-AT compatible computer KV-H6WE/KV-H4EW KV
module Connection: terminal block
Z-1 Memory Card Reader/writer Ladder Software (3 1/2")
M-2/3 Memory Card KV-P3E Handheld programmer KV-R8R I/O Terminal Module Rated load: 250 VAC 2 A, Outputs: 8,
(Relay-Output) Connection: terminal block
KV-R16R I/O Terminal Module Rated load: 250 VAC 2 A, Outputs: 16,
(Relay-Output) Connection: terminal block
Instruction list
KV-R8T I/O Terminal Module Rated load: 30 VDC 0.3 A, Outputs: 8,
Basic instructions
(Transistor-Output) Connection: terminal block
Instruction Symbol Mnemonic Function
KV-R16T I/O Terminal Module Rated load: 30 VDC 0.3 A, Outputs: 16,
0.1-s TIMER #ddddd TMR 16-bit on-delay timer. Counts down in 0.1-s (Transistor-Output) Connection: terminal block
T xxx decrements.
KV-L2 Serial Interface Module Communication port: one RS-232C and one
0.01-s TIMER #ddddd TMH (FNC49) 16-bit on-delay timer. Counts down in 0.01-s RS-232C/RS-422A switchable port
T xxx
H decrements. KV-AN6 Analog I/O Module Analog input: 4 channels (±10 V/±5 V/0 to 20 mA
switch selectable), Analog output: 2 channels
1 ms TIMER #ddddd TMS (FNC51) 16-bit on-delay timer. Counts down in 1-ms
T xxx (±10 V/±5 V/4 to 20 mA switch selectable)
S decrements.
OP-21734 Crimping Tool For easy wiring of connector I/O modules
COUNTER #ddddd C Sets 16-bit counter.
C xxx
nnnn

16 BIT
COUNTER
CTH1
nnnn
CTH 16-bit (0 to 65535) up-counter for clock pulses
with input response frequency of 30 kHz.
Packed with convenient features
16 BIT CTC Hardware-based comparator compares between Built-in ramp up/down program
COUNTER #ddddd preset & current values of high-speed counter. Merely enter three parameters, including pulse frequency, in data
COMPARATOR CTCn This comparator turns ON when these values
are equal. memory to control stepper motors and pulse-input AC servomo-
tors. Output is not affected by scan-time delay.
Application instructions
Instruction Symbol Mnemonic Function Frequency
(Hz)
UP-DOWN UDC xxx UDC Sets a 16-bit up-down counter.
UP #ddddd
COUNTER DW
RES
(FNC52) Operation

HIGH SPEED HSP HSP Reduces input relay time constant to 25 µs for higher
nnnn
(FNC18) input response. Start Output pulse count

MASTER MC MC Selects ON/OFF status of R coils, Ts, or Cs. Acceleration Deceleration Time (ms)
CONTROL (FNC24) time time

MASTER MCR Represents end of MC.


CONTROL MCR
(FNC25) High-speed interrupt input
RESET CPU inputs 000 to 003 can be used as 10 µs interrupt inputs, so
MEMORY MEMSW MEMSW Sets memory switches. short inputs won't be missed.
SWITCH $xxxx (FNC26)

STAGE STG Executes instructions between STG & JMP when R


Two 30-kHz high-speed counters
nnnn
STG (FNC44) (operand) is ON. These counters can handle 2-channel quadrature inputs for phases
A/B.
JUMP nnnn JMP Turns current stage OFF and next stage ON when input
JMP (FNC21) is ON.

END STAGE ENDS Turns current stage OFF when input is ON.
ENDS (FNC14) Unique Special Utility Relays
16 KEY INPUT HKEY
nnnn HKEY Reads hexadecimal key data and outputs this data to 2807
mmmm
(FNC 17) special utility relays.
This relay enables the KV CPU to transmit text data automatically
Arithmetic instructions Interrupt instructions via the serial port without any commands from an external com-
TRIMMER SETTING TMIN INTERRUPT DISABLED DI puter.
TRANSFER BCD TBCD INTERRUPT ENABLED EI
TRANSFER BIN TBIN INTERRUPT INT 2813
ASCII CONVERT ASC RETURN INTERRUPT RETI This relay sets the time constants of inputs 000 to 009 to 10 µs at
REVERSE ASCII CONVERT RASC the same time.
SQUARE ROOT ROOT
Note: Only the principal instructions are listed above.
6
Specifications
Environmental specifications (Common to all modules) System specifications KV-300
Ambient temperature 0 to 50°C, KV-P3E: 0 to 45°C Programming languages Ladder diagram and extended ladder diagram
Relative humidity 35 to 85% Number of instructions Basic: 16 Application: 34 Arithmetic: 26 Interrupt: 4
Withstand voltage 1500 VAC applied between power terminal and I/O terminals, and Instruction processing time Basic instruction: 0.15 µs min., 0.6 µs average
between external terminals and housing (1 min.) Application instruction: 0.30 µs min., 10.0 µs average
Excluding the AC power supply module/DC power distribution
module, KV-AN6 and KV-L2 Max. number of steps 8000
Noise immunity Noise generated by noise simulator: 1500 V p-p min. 1 µs Input/output 14 to 1774 (when max. number of I/O distribution modules
and 50 ns (including 14 I/Os of CPU) are connected)
14 to 366 (when max. number of connector I/O modules are
Vibration resistance 10 to 55 Hz. Double amplitude of 1.5 mm max. applied in X, Y,
connected)
and Z directions (2 hrs) 1G when mounted to DIN rail
Maximum number of 11 (13 if KV-AN6 and KV-L2 are included.)
Minimum insulation resistance 50 MΩ between power terminal and I/O terminals, and between
expansion modules
external terminals and housing (measured with 500 VDC
megohmmeter) Internal utility relays 800 (with latching function)
Environmental restrictions No excessive dust or corrosive gas Special utility relays 160
Data memory (16-bit) 10,000 words
Power supply Temporary memory (16-bit) 32 words
Model KV-U4 KV-U5 Timers/counters Total: 250 (including two analog timers)
Input supply voltage 100 to 240 VAC ±10% 50/60 Hz 24 VDC ±10% High-speed counter 2-phase high-speed counter: 0 to 65535 counts (max. input
response frequency: 30 kHz)
Output voltage 24 VDC ±10% –
High-speed counter comparator 4 (2 each for high-speed counters) Direct output allowed
Ripple/noise 240 mV p-p max. –
Maximum direct clock pulse 50 kHz 2 independent axes (with X-Y positioning)
Output current 1.4 A (Total of power supplied to connected 3.5 A
modules and service power supply) Number of element comments storable 1000
Weight (excluding brackets) Approx. 340 g Approx. 90 g Memory backup Program memory: EEPROM: Rewritable 50,000 times
Data memory, counter: Data retained for 5 years
minimum at 25°C
I/O built-in CPU KV-300
Maximum current consumption 160 mA
Input
Weight Approx. 110 g
Input modes 24 VDC input mode 5 VDC input mode
Rated voltage 26.4 VDC max.
Input voltage and current 24 VDC 5.3 mA 5 VDC 1 mA I/O distribution module KV-R1A
Threshold voltage (ON) 19 V 3.5 V Communication mode 1: N 2-wire communication
Threshold current (OFF) 1.5 mA – Connection Multi-branching or multi-drop
Threshold voltage (OFF) – 1.5 V Transmission rate 1.25 Mbit/s
Common ground 10 I/O per common terminal Maximum transmission delay 500 µs
Input time constant Normal: 10 ms ±20% Transmission distance1. 120 m (total length)
When HSP instruction is used: 25 µs ±20% Maximum number of Input terminals: 5 (80 inputs)
When special utility relay 2813 is ON: 10 µs ±20% I/O terminal modules Output terminals: 5 (80 outputs)
(for both OFF/ON switching)
Transmission media2. 2-core wire (VCTF 0.75 mm2) or AWG 18 twisted pair
Output
Error control method 2-bit reverse check
Type of output Transistor NPN
Maximum current consumption 75 mA
Rated load 30 VDC 0.1 A
Weight Approx. 100 g
Maximum leakage current at OFF 100 µA
1. Total length of the transmission cable. 2. Use unshielded cable.
Maximum residual voltage at ON 0.3 V
Maximum switching time 10 µs (for both OFF/ON and ON/OFF switching)
Common ground 4 I/O per common terminal
Analog I/O module KV-AN6
A/D specifications
Analog input (switch selectable) Voltage: ±10 V/±5 V Current: 0 to 20 mA
Input module Absolute input Voltage: ±12 V max. Current: ±30 mA max.
Connector I/O I/O distribution terminal Input impedance Voltage: 1 MΩ Current: 350 Ω
Model KV-C16X KV-C32X KV-R8X KV-R16X Analog input channels 4 channels
Inputs 16 32 8 16 Resolution 1/4000
Connection Connector (Conforms to MIL Standard) Terminal block Digital data format 16-bit binary, complement of two
Input voltage and current 24 VDC (5.3 mA) 24 VDC (5.3 mA) Effective bits are the 12 bits starting from the most significant bit.
5 VDC (1 mA) switchable Total accuracy ±1% of full scale
Threshold voltage (ON) 19 V (Input mode: 24 VDC) 19 V Conversion rate 720 µs/4 ch
3.5 V (Input mode: 5 VDC)
Isolation method Photocoupler: Not isolated between channels or between A/D and
Threshold current (OFF) 1.5 mA (Input mode: 24 VDC) 1.5 mA D/A converters
Threshold voltage (OFF) 1.5 V (Input mode: 5 VDC) – D/A specifications
Input time constant (OFF➞ON) (ON➞OFF) Analog output1. Voltage: ±10 V/±5 V Current: 4 to 20 mA
(3-way switchable) (0 ms) 25 µs ±20% (0 ms) 75 µs ±20%
Output impedance Voltage: 100 Ω
(1 ms) 1 ms ±20% (1 ms) 1 ms ±20%
(10 ms) 10 ms ±20% (10 ms) 10 ms ±20% Max. load resistance Current: 400 Ω
Common ground 16 I/O per 32 I/O per 8 I/O per 16 I/O per Analog output channels 2 channels
common terminal common terminal common terminal common terminal Conversion rate 360 µs/2 ch
Input supply voltage – 24 VDC ±10% Current consumption 240 mA max.
Maximum current consumption 15 mA max. 25 mA max. 30 mA max. Weight Approx. 200 g
Weight Approx. 80 g Approx. 95 g Approx. 130 g Approx. 180 g 1. Voltage output: switch selectable; current output: use separated terminal

Output module
Connector I/O I/O distribution terminal
Model KV-B16R KV-B16S KV-C32T KV-R8R KV-R16R KV-R8T KV-R16T
Output type Relay Triac Transistor (NPN) Relay Transistor
Outputs 16 16 32 8 16 8 16
Connection Removable terminal block Connector Terminal block —
(conforms to MIL Standard)
Rated load 250 VAC 2 A 250 VAC 0.3 A 30 VDC 0.2 A 250 VAC 2 A
30 VDC 2 A Continuous load current 30 VDC 2 A 30 VDC 0.3 A
8 A per common 1.2 A per common 8 A per common
Peak load current 5A 20 A — 5A –
Maximum OFF➞ON 10 ms 1/2 cycle + 2 ms 10 µs 10 ms 50 µs
switching time ON➞OFF 10 ms 1/2 cycle + 2 ms 100 µs 10 ms 50 µs
Maximum leakage current at OFF — 2 mA 100 µA — 100 µA —
Maximum residual voltage at ON — — 0.5 V — 0.5 V
Common ground 8 I/O per 8 I/O per 32 I/O per 4 I/O per 8 I/O per 16 I/O per
common terminal common terminal common terminal common terminal common terminal common terminal
Input supply voltage — — — 24 VDC ±10%
Maximum current consumption 150 mA 85 mA 55 mA 85 mA 150 mA 35 mA 50 mA
Weight Approx. 200 g Approx. 200 g Approx. 70 g Approx. 160 g Approx. 240 g Approx. 130 g Approx. 180 g

7
Dimensions Unit: mm

KV-U4 KV-U5 KV-R1A

27.3
Super-small PLCs
also available!
90 90 90 35.4

4 4 4

60 31.7 4.5 25 85

KV-300 End unit

27.3

90 35.4

115
88.5

4.4 25 8.5 80 The KV-10/80 Series of PLCs pro-


85 vide integral local control of up to
108
80 I/Os without the need for addi-
(35) 100
tional I/O units. Expansion I/O
KV-C16X/C32T KV-C32X units provide up to 128 I/Os.

Contact us for details today.


27.3

90 35.4
90

4 4

4.4 13.1 4.4 18 85


(45) 100

KV-B16R/B16S/AN6 KV-L2 KV-P3E


90 29.5

27.3

90 90 35.4 168

4 4

(68) 88 70 24
4.4 35 4.4 35

KV-R16R/R16T/R16X 2 x φ4.6
KV-R8R/R8T/R8X 2 x φ4.6
(mounting hole) (mounting hole)
7.2 7.2

50 35.4 50 42 35.4
42

5.2 157 35 5.2 107 35


165 59.3 115 59.3

Visit our website for other Keyence products at


Specifications are subject to change without notice.

KEYENCE CORPORATION OF AMERICA


Corporate Office
50 Tice Blvd., Woodcliff Lake, NJ 07677, U.S.A.
Boston Office Atlanta Office Cincinnati Office Minneapolis Office Phoenix Office
Phone:781-453-2244 Fax:781-453-2255 Phone:770-951-1222 Fax:770-951-1958 Phone:513-554-1227 Fax:513-554-1229 Phone:952-924-9779 Fax:952-249-9143 Phone:602-225-2400 Fax:602-225-2425
New Jersey Office Tampa Office Michigan Office St. Louis Office Portland Office
Phone:201-291-4000 Fax:201-291-8860 Phone:813-998-9886 Fax:813-998-9887 Phone:734-591-9922 Fax:734-591-1722 Phone:314-275-9174 Fax:314-275-9175 Phone:503-699-0500 Fax:503-699-8400
Pennsylvania Office Cleveland Office Indianapolis Office Texas Office Northern California Office
Phone:610-768-8993 Fax:610-337-1067 Phone:216-464-7530 Fax:216-464-7540 Phone:317-843-2616 Fax:317-843-2647 Phone:972-733-6790 Fax:972-733-6791 Phone:925-225-1550 Fax:925-225-1440
Charlotte Office Columbus Office Chicago Office Denver Office Los Angeles Office
Phone:704-423-0070 Fax:704-423-0066 Phone:614-799-3400 Fax:614-799-3401 Phone:847-969-0001 Fax:847-969-0453 Phone:303-756-5242 Fax:303-756-8301 Phone:310-851-8635 Fax:310-851-8681

©KEYENCE CORPORATION, 1995 KV300WIN-KA-C-1-0898 Printed in Japan