Super Micro PLC
● Simplified wiring
Unmatched flexibility for
significant cost & time savings
The Keyence Solution: The new KV I/O Distribution System requires only
two wires for all wiring between the PLC and each I/O. Plus, it eliminates the intermedi-
ate terminal blocks used in conventional systems. What's more, its fast – you can ex-
pect scan times of close to 0.5 ms, even with the maximum of 1774 I/Os.
2
The Flexibility for Brand M
Compact 178.3
Keyence systems are one-third the volume and require only one- 260
half the footprint of conventional units. So control panels are 379
smaller and wiring space is significantly reduced.
New Modular Design Keyence components set new standards for compact design.
Keyence's original modular de-
sign allows easy mounting on a
DIN rail and employs a quick-dis-
connect lock mechanism. No ad-
ditional rack or base is required
when extending the system con- Connector I/O Modules
figuration. Our expansion connector I/O module (only 14 mm thick)
can be added to the CPU. It is available in five models,
including 16-inputs or 16-outputs (Triac/Relay), and 32-
inputs or 32-outputs (Transistor).
line equipment. KV
Ladder Builder for KV L2
U4
CPU can communicate with
In this example, a Keyence sensor multiple CPUs to edit
measures sheet thickness for control- programs and monitor
ling the speed of an extruder motor. operation.
What's more, a computer
can monitor a CPU while
communicating with an-
other computer through
the serial port. RS-232C RS-422A
And thanks to the built- KV KV KV
in Display Interface
Mode, you can easily 300
L2
connect a commercially
KV KV
available display unit to
the CPU.
The problem: Installation problems are inevitable when ma- The Keyence Solution: With Ladder Builder Software,
chinery, control panels, and PLC programs are developed indepen- you save programming and debugging time. Our original Desktop
dently. Complicated, time-consuming rewiring, machinery readjust- Simulator feature lets you check program operation in advance –
ment, and reprogramming are unavoidable. Even worse, on-site de- without first connecting to machinery, I/O devices, or even a PLC. By
bugging becomes slow and labor-intensive, because the program verifying your program on computer, you can troubleshoot problems
can't be seen. The result is delayed production and increased cost before installation, avoiding tedious rewiring and adjustment on-site.
pressures.
Registration Monitor
Ladder Builder for KV can display multiple timing charts
of devices simultaneously. This enables convenient
checking of all element on/off timing.
Monitor
Real time monitoring without stopping the machine
Ladder diagram and element on/off status can be monitored real time.
Timing charts can be monitored simultaneously.
Editor
Easy editing using Windows® functions
16 BIT
COUNTER
CTH1
nnnn
CTH 16-bit (0 to 65535) up-counter for clock pulses
with input response frequency of 30 kHz.
Packed with convenient features
16 BIT CTC Hardware-based comparator compares between Built-in ramp up/down program
COUNTER #ddddd preset & current values of high-speed counter. Merely enter three parameters, including pulse frequency, in data
COMPARATOR CTCn This comparator turns ON when these values
are equal. memory to control stepper motors and pulse-input AC servomo-
tors. Output is not affected by scan-time delay.
Application instructions
Instruction Symbol Mnemonic Function Frequency
(Hz)
UP-DOWN UDC xxx UDC Sets a 16-bit up-down counter.
UP #ddddd
COUNTER DW
RES
(FNC52) Operation
HIGH SPEED HSP HSP Reduces input relay time constant to 25 µs for higher
nnnn
(FNC18) input response. Start Output pulse count
MASTER MC MC Selects ON/OFF status of R coils, Ts, or Cs. Acceleration Deceleration Time (ms)
CONTROL (FNC24) time time
END STAGE ENDS Turns current stage OFF when input is ON.
ENDS (FNC14) Unique Special Utility Relays
16 KEY INPUT HKEY
nnnn HKEY Reads hexadecimal key data and outputs this data to 2807
mmmm
(FNC 17) special utility relays.
This relay enables the KV CPU to transmit text data automatically
Arithmetic instructions Interrupt instructions via the serial port without any commands from an external com-
TRIMMER SETTING TMIN INTERRUPT DISABLED DI puter.
TRANSFER BCD TBCD INTERRUPT ENABLED EI
TRANSFER BIN TBIN INTERRUPT INT 2813
ASCII CONVERT ASC RETURN INTERRUPT RETI This relay sets the time constants of inputs 000 to 009 to 10 µs at
REVERSE ASCII CONVERT RASC the same time.
SQUARE ROOT ROOT
Note: Only the principal instructions are listed above.
6
Specifications
Environmental specifications (Common to all modules) System specifications KV-300
Ambient temperature 0 to 50°C, KV-P3E: 0 to 45°C Programming languages Ladder diagram and extended ladder diagram
Relative humidity 35 to 85% Number of instructions Basic: 16 Application: 34 Arithmetic: 26 Interrupt: 4
Withstand voltage 1500 VAC applied between power terminal and I/O terminals, and Instruction processing time Basic instruction: 0.15 µs min., 0.6 µs average
between external terminals and housing (1 min.) Application instruction: 0.30 µs min., 10.0 µs average
Excluding the AC power supply module/DC power distribution
module, KV-AN6 and KV-L2 Max. number of steps 8000
Noise immunity Noise generated by noise simulator: 1500 V p-p min. 1 µs Input/output 14 to 1774 (when max. number of I/O distribution modules
and 50 ns (including 14 I/Os of CPU) are connected)
14 to 366 (when max. number of connector I/O modules are
Vibration resistance 10 to 55 Hz. Double amplitude of 1.5 mm max. applied in X, Y,
connected)
and Z directions (2 hrs) 1G when mounted to DIN rail
Maximum number of 11 (13 if KV-AN6 and KV-L2 are included.)
Minimum insulation resistance 50 MΩ between power terminal and I/O terminals, and between
expansion modules
external terminals and housing (measured with 500 VDC
megohmmeter) Internal utility relays 800 (with latching function)
Environmental restrictions No excessive dust or corrosive gas Special utility relays 160
Data memory (16-bit) 10,000 words
Power supply Temporary memory (16-bit) 32 words
Model KV-U4 KV-U5 Timers/counters Total: 250 (including two analog timers)
Input supply voltage 100 to 240 VAC ±10% 50/60 Hz 24 VDC ±10% High-speed counter 2-phase high-speed counter: 0 to 65535 counts (max. input
response frequency: 30 kHz)
Output voltage 24 VDC ±10% –
High-speed counter comparator 4 (2 each for high-speed counters) Direct output allowed
Ripple/noise 240 mV p-p max. –
Maximum direct clock pulse 50 kHz 2 independent axes (with X-Y positioning)
Output current 1.4 A (Total of power supplied to connected 3.5 A
modules and service power supply) Number of element comments storable 1000
Weight (excluding brackets) Approx. 340 g Approx. 90 g Memory backup Program memory: EEPROM: Rewritable 50,000 times
Data memory, counter: Data retained for 5 years
minimum at 25°C
I/O built-in CPU KV-300
Maximum current consumption 160 mA
Input
Weight Approx. 110 g
Input modes 24 VDC input mode 5 VDC input mode
Rated voltage 26.4 VDC max.
Input voltage and current 24 VDC 5.3 mA 5 VDC 1 mA I/O distribution module KV-R1A
Threshold voltage (ON) 19 V 3.5 V Communication mode 1: N 2-wire communication
Threshold current (OFF) 1.5 mA – Connection Multi-branching or multi-drop
Threshold voltage (OFF) – 1.5 V Transmission rate 1.25 Mbit/s
Common ground 10 I/O per common terminal Maximum transmission delay 500 µs
Input time constant Normal: 10 ms ±20% Transmission distance1. 120 m (total length)
When HSP instruction is used: 25 µs ±20% Maximum number of Input terminals: 5 (80 inputs)
When special utility relay 2813 is ON: 10 µs ±20% I/O terminal modules Output terminals: 5 (80 outputs)
(for both OFF/ON switching)
Transmission media2. 2-core wire (VCTF 0.75 mm2) or AWG 18 twisted pair
Output
Error control method 2-bit reverse check
Type of output Transistor NPN
Maximum current consumption 75 mA
Rated load 30 VDC 0.1 A
Weight Approx. 100 g
Maximum leakage current at OFF 100 µA
1. Total length of the transmission cable. 2. Use unshielded cable.
Maximum residual voltage at ON 0.3 V
Maximum switching time 10 µs (for both OFF/ON and ON/OFF switching)
Common ground 4 I/O per common terminal
Analog I/O module KV-AN6
A/D specifications
Analog input (switch selectable) Voltage: ±10 V/±5 V Current: 0 to 20 mA
Input module Absolute input Voltage: ±12 V max. Current: ±30 mA max.
Connector I/O I/O distribution terminal Input impedance Voltage: 1 MΩ Current: 350 Ω
Model KV-C16X KV-C32X KV-R8X KV-R16X Analog input channels 4 channels
Inputs 16 32 8 16 Resolution 1/4000
Connection Connector (Conforms to MIL Standard) Terminal block Digital data format 16-bit binary, complement of two
Input voltage and current 24 VDC (5.3 mA) 24 VDC (5.3 mA) Effective bits are the 12 bits starting from the most significant bit.
5 VDC (1 mA) switchable Total accuracy ±1% of full scale
Threshold voltage (ON) 19 V (Input mode: 24 VDC) 19 V Conversion rate 720 µs/4 ch
3.5 V (Input mode: 5 VDC)
Isolation method Photocoupler: Not isolated between channels or between A/D and
Threshold current (OFF) 1.5 mA (Input mode: 24 VDC) 1.5 mA D/A converters
Threshold voltage (OFF) 1.5 V (Input mode: 5 VDC) – D/A specifications
Input time constant (OFF➞ON) (ON➞OFF) Analog output1. Voltage: ±10 V/±5 V Current: 4 to 20 mA
(3-way switchable) (0 ms) 25 µs ±20% (0 ms) 75 µs ±20%
Output impedance Voltage: 100 Ω
(1 ms) 1 ms ±20% (1 ms) 1 ms ±20%
(10 ms) 10 ms ±20% (10 ms) 10 ms ±20% Max. load resistance Current: 400 Ω
Common ground 16 I/O per 32 I/O per 8 I/O per 16 I/O per Analog output channels 2 channels
common terminal common terminal common terminal common terminal Conversion rate 360 µs/2 ch
Input supply voltage – 24 VDC ±10% Current consumption 240 mA max.
Maximum current consumption 15 mA max. 25 mA max. 30 mA max. Weight Approx. 200 g
Weight Approx. 80 g Approx. 95 g Approx. 130 g Approx. 180 g 1. Voltage output: switch selectable; current output: use separated terminal
Output module
Connector I/O I/O distribution terminal
Model KV-B16R KV-B16S KV-C32T KV-R8R KV-R16R KV-R8T KV-R16T
Output type Relay Triac Transistor (NPN) Relay Transistor
Outputs 16 16 32 8 16 8 16
Connection Removable terminal block Connector Terminal block —
(conforms to MIL Standard)
Rated load 250 VAC 2 A 250 VAC 0.3 A 30 VDC 0.2 A 250 VAC 2 A
30 VDC 2 A Continuous load current 30 VDC 2 A 30 VDC 0.3 A
8 A per common 1.2 A per common 8 A per common
Peak load current 5A 20 A — 5A –
Maximum OFF➞ON 10 ms 1/2 cycle + 2 ms 10 µs 10 ms 50 µs
switching time ON➞OFF 10 ms 1/2 cycle + 2 ms 100 µs 10 ms 50 µs
Maximum leakage current at OFF — 2 mA 100 µA — 100 µA —
Maximum residual voltage at ON — — 0.5 V — 0.5 V
Common ground 8 I/O per 8 I/O per 32 I/O per 4 I/O per 8 I/O per 16 I/O per
common terminal common terminal common terminal common terminal common terminal common terminal
Input supply voltage — — — 24 VDC ±10%
Maximum current consumption 150 mA 85 mA 55 mA 85 mA 150 mA 35 mA 50 mA
Weight Approx. 200 g Approx. 200 g Approx. 70 g Approx. 160 g Approx. 240 g Approx. 130 g Approx. 180 g
7
Dimensions Unit: mm
27.3
Super-small PLCs
also available!
90 90 90 35.4
4 4 4
60 31.7 4.5 25 85
27.3
90 35.4
115
88.5
90 35.4
90
4 4
27.3
90 90 35.4 168
4 4
(68) 88 70 24
4.4 35 4.4 35
KV-R16R/R16T/R16X 2 x φ4.6
KV-R8R/R8T/R8X 2 x φ4.6
(mounting hole) (mounting hole)
7.2 7.2
50 35.4 50 42 35.4
42