You are on page 1of 3

Hoofdstuk 30 ice and rain protection.

Vragen vacbi

1.
Witch slats are supplied with hot air

A) all slats
B) the four out board slats B
C) the three inboard slats.

2.
What happens when the wing anti-ice p/b is set on the ground
A) the wing anti ice valves do not open
B) the wing anti ice valves remain open
C) the wing anti ice valve open for 30 sec
C

3.
What happens in case of loss of electrical supply with engines running
A) the valves moves to the closed position
B) The valves moves to an intermediate position
C) the valves moves to the open position. C

4.
How are the valves controlled
A) By a p/b for each engine
B) By a general p/b
C) Automatically A

5.
When is the tat probe heated
A) On ground not in flight
B) In icing conditions only
C) In flight not on ground C

6.
When is the pitot probe heated
A) in flight not on ground
B) in icing conditions only
C) normal heating in flight, low on ground C

7.
What happens in case of a WHC failure
A) the failed WHC connects to the other
B) The other WHC replaces the failed one
C) The heating of the related side is lost C
8.
what happens when the eivmu power supply c/b is pulled

A) Noting happens
B) The windshield heating is cut off
C) The windows and windshield are heated C

9.
How are the left(right) window heating elements connected
A) In series
B) In parallel
C) Independently A

10.
What happens when the temperature reaches +60 C
A) The heating is cut off
B) Noting
C) The whc is disconnected A

11.
How is each wiper controlled
A) by a three position rotary selector
B) By a p/b
C) Automatically related to the weather condition A

12.
When is the rain repellent system inhibited
A) In flight
B) On ground
C) On ground when engines are shut down C

13.
What should be done in case of inadvertent operation
A) Wash at the earliest opportunity
B) Wash at the next overhaul
C) No action is necessary A

14.
How is the water ice protection system controlled
A) Automatically
B) By a p/b in the cockpit
C) By a p/b on the forward attendant panel A

15.
Where can the system status be read
A) On the e/w display of the ecam system
B) On the status display of the ecam system
C) On the pim and indication module of the cids and on the mcdu C

.
16.
When are the heating elements switched on
A) At first engine start up
B) At door closure
C) In case of icing condition C

17.
How many heating elements does each locking plate have
A) One
B) Two
C) Four B

18.
How is the control unit supplied
A) With 115V AC
B) With 28V DC
C) With 5V DC A

19.
What is the purpose of the PSCU signal
A) To prevent unnecessary heating
B) To prevent damage to heaters in case of over temperature
C) To manually control the heating via the emergency escape slide control lever. A

20.
How many levels of ice detection are provided
A) Two
B) Three
C) Seven A

21.
When is the ice detection inhibited
A) At last engine shut down
B) At electrical power off
C) On ground below 1500 FT C

You might also like