Professional Documents
Culture Documents
NON-UL CITYMULTI Catalog - JUN2018 PDF
NON-UL CITYMULTI Catalog - JUN2018 PDF
INTERNATIONAL
WWW.MITSUBISHIPRO.COM
MITSUBISHI ELECTRIC IS A WORLD
LEADER IN PRODUCTS THAT HELP
PEOPLE LIVE BETTER
When it comes to providing personalized comfort in every room of every building, we are
here to help. No other company is as committed to creating environmentally friendly and
affordable technology that’s ideal for today’s home and work environments, no matter the
size or shape.
QUALITY
Mitsubishi Electric is consistently recognized by HVAC contractors as the #1 preferred brand
with the highest quality rating among manufacturers. With over 30 years of industry leadership,
we are proud to be America’s leading brand of variable refrigerant flow (VRF) technology.
PERFORMANCE
We deliver a complete range of compact and powerful heat pump products that are also
intelligent, quiet, and use energy effectively.
TRAINING
We provide comprehensive product and applications instruction through our regional training
centers across the United States and Mexico.
SUPPORT
We offer the most extensive network of experienced VRF zoning system professionals to
provide project consultation in the areas of application planning and design, plus installation
and startup. Post installation, we can provide support, including user training and operation
monitoring.
GROWTH
Our products and services provide opportunities for architects, engineers, distributors
and contractors to enhance and grow their businesses. With nearly 30 years of consistent
growth, we continue to lead the ductless and VRF market’s acceleration.
ECO CHANGES
Eco Changes is our commitment to continuously strive for a greener tomorrow through
cutting-edge global environmental technologies and outstanding strength in manufacturing.
IFC2
TABLE OF CONTENTS
VENTILATION
PremiSys® Dedicated Outdoor Air System. . . . . 36
PremiSys® Fusion. . . . . . . . . . . . . . . . . . 37
Lossnay ® Energy Recovery Ventilators (ERVs). . . 38
Dedicated Outdoor Air System (DOAS). . . . . . . 39
4
OVERVIEW OF CITY MULTI
PRODUCT OVERVIEW
QUIET OPERATION
20 40 60 80
OUTDOOR UNITS
Mitsubishi Electric offers an extensive air-source unit lineup that can be tailored to any
application’s requirements.
S-Series
Y-Series
6
OVERVIEW OF CITY MULTI
INDOOR UNITS
Mitsubishi Electric’s wide range of indoor units enables you to choose the style and
size that meets your requirements for layout and design.
PKFY
Wall-mounted
PEFY-VMS1 Low Profile
PEFY-VMA Medium Static
PEFY-VMH High Static
PMFY
Ceiling Cassette (1-way)
PFFY-VLEM Exposed
PFFY-VLRM Concealed
PCFY
Ceiling-suspended
PLFY-VBM (33"x33")
PLFY-VCM (22"x22")
Ceiling Cassette (4-Way)
PLFY-VLMD
Ceiling Cassette (2-Way) PFAV-Series
PMFY-VBM
Ceiling Cassette (1-Way)
CENTRALIZED CONTROLLERS
ZONE CONTROLLERS
8
OVERVIEW OF CITY MULTI
PAC-US444CN-1
LMAP04U Thermostat Interface
LonWorks® Interface
CITY MULTI outdoor units feature a lightweight modular design with a minimal
footprint, lower sound level, easy piping, maintenance and much more.
1. INVERTER-DRIVEN COMPRESSOR TECHNOLOGY
The compressor varies its speed to match the indoor cooling or heating demand to consume only the energy
required. No other compressor design can match the efficient performance.
2. EASY MAINTENANCE
In many cases, our systems allow an indoor unit to be serviced while other indoor units within the same piping
system are still in operation. Indoor units only require periodic filter changes and cleaning. The protective
coating comes standard on air-source outdoor units to lengthen coil life while additional Bermuda Special
treatment, designated -BS within the model number, provides enhanced protection for the rest of the outdoor
unit in sea-coast environments.
5. QUIET OPERATION
CITY MULTI air-source outdoor units operate at sound levels as low as 58 dB(A)—the level of a common office
environment, restaurant conversation or background music. Contributing features include our INVERTER-driven
compressor compartment sealed by insulation-lined metal panels, vibration-absorbing compressor mounts,
INVERTER-driven fan and Low Noise operating mode.
10
OVERVIEW OF CITY MULTI
12 12
OUTDOOR UNITS
Y–Series / S–Series
MITSUBISHI ELECTRIC
MITSUBISHI Cooling
ELECTRIC & Heating
Cooling / CITY /MULTI
& Heating CITY /MULTI
13 / 13
TONS 3.5 4.0 4.5 5.0 8.0 10.0 12.0
PFAV-Series
PFAV 95
107
14
SHOWCASE
16 20 25 35 40 50 TONS
563
573
307
-4˚ F (-20.0˚C) Y-Series 60˚ F (15.5˚C)
-13˚ F
CITY MULTI OUTDOOR UNIT OPERATING RANGES CITY MULTI OUTDOOR UNIT OPERATING RANGES
-10˚ F 0˚ F 10˚ F 20˚ F 30˚ F 40˚ F 50˚ F 60˚ F 10˚ F 20˚ F 30˚ F 40˚ F 50˚ F 60˚ F 70˚ F 80˚ F 90˚ F 100˚ F 110˚ F 120˚ F 130˚ F
-13˚ F
23˚F (-5.0˚C)
Outdoor Dry Bulb Temperature
F 20˚ F 30˚ F 40˚ F 50˚ F 60˚ F 70˚ F 80˚ F 90˚ F 100˚ F 110˚ F 120˚ F 130˚ F
23˚F (-5.0˚C)
MITSUBISHI
Y-Series ELECTRIC Cooling & Heating / CITY MULTI / 15
126˚ F (52.0˚C)
Y-SERIES
Y-Series outdoor units are flexible enough to cool or heat up to 50 individual zones, maximizing
building design options. The modular unit design features a small footprint and low operating sound.
▶▶ Single modules up to 16 tons with the ability to combine modules for systems
up to 47 tons
▶▶ Improved static pressure with new bellmouth-shaped hood, reducing fan rotation
and increasing the pressure at the hood outlet
▶▶ Effective use of space, with a smaller footprint and service space requirement
▶▶ Extended 10-year parts and compressor warranty available
Total Length 3
3,280 (1,000)
Indoor/Indoor 49 (15)
1. 295’ (90m) is available depending on model and installation conditions. For more detailed information, contact your local distributor.
2. 197’ (60m) is available depending on model and installation conditions. For more detailed information, contact your local distributor.
3. The maximum total piping in the system with the P1400 through P1500 model is 2624’ (800m).
16
OUTDOOR UNITS
Benefits
ULTIMATE IN ZONING
The CITY MULTI Y-Series uses a two-pipe system with a wide variety of indoor units and individual zone controllers
to provide the ultimate zoning system. Headers and T-branches simplify the piping design and provide design
freedom for placement of both piping and indoor units. Individual zones are managed by remote controllers
placed in each zone or by the centralized controller.
COOLING HEATING
DESIGN FLEXIBILITY
Flexibility is the key with the CITY MULTI Y-Series. The Y-Series can condition up to 50 zones. By using
T-branches and headers, the Y-Series provides the ultimate in piping design flexibility that is truly simple in
application.
S-SERIES (PUMY)
The CITY MULTI S-Series (PUMY) is a single-phase heat pump system perfect for light
commercial or large residential applications. Featuring best-in-class efficiency ratings and
ENERGY STAR® certification, PUMY systems are designed to deliver operational cost savings
and long-time performance to a homeowner or building owner. It uses the CITY MULTI
Controls Network (CMCN) to cool or heat up to 12 individual zones with a choice of indoor
unit styles.
KEY FEATURES
Indoor/Indoor 49 (15)
18
LEV KIT
CONTROL
BOX
LEV Assembly Model* Capacity Code Setting [Ton] Design Capacity Range [Btu/h]
20
INDOOR UNITS
PKFY Wall–mounted/PLFY Ceiling Cassette/PMFY Ceiling Cassette/
PCFY Ceiling–suspended/PEFY Ceiling–concealed Ducted/
PFFY Floor–standing/ PFAV-Series
5,800 7,500 9,600 12,300 15,400 19,100 24,200 27,300 30,700 38,200 47,800 54,600 76,400 95,000
Wall-mounted
PKFY–P VBM-E
PKFY-P VHM-E • • • • • • • •
PKFY-P VKM-E
Ceiling Cassette
(4-way)
PLFY-P VBM-E • • • • •
Ceiling Cassette
(4-way)
PLFY–P VCM-E • • • • • • •
Ceiling Cassette
(1-way)
PLFY-P VLMD-E • • • • • • • • •
Ceiling Cassette
(1-way)
PMFY–P VBM-E • • • •
Ceiling-suspended
PCFY-P VKM-E
• • • •
Ceiling-concealed
(Ducted
Low–Profile) • • • • • • •
PEFY–P–VMS1-E
Ceiling-concealed
(Ducted
Medium-Static) • • • • • • • • • • •
PEFY–P–VMA-E
Ceiling-concealed
(Ducted High-Static)
PEFY–P VMH-E • • • • • • • • • •
Floor-standing
(Exposed/
Concealed)
PFFY–P VLEM-E • • • • • •
PFFY-P VREM-E
22
INDOOR UNITS
PKFY (Wall–mounted)
KEY FEATURES
▶▶ Ranges from 5,800 to 38,200 Btu/h
▶▶ Compact, lightweight and features a built-in wireless sensor for use with an optional wireless
remote controller
▶▶ Extremely quiet, as low as 29 dB(A)
▶▶ Multiple fan speed settings
▶▶ Multiple vane settings and swing setting adjust airflow in vertical directions
▶▶ Front panel opens easily—no tools are needed to gain access to the filter
▶▶ Refrigerant and drain piping can be connected from the rear, right, base, or left of the unit
▶▶ Condensate Pump Systems are available when gravity drainage is not available
Benefits
QUIET OPERATION
The unit incorporates a random–pitch fan to assure quiet operation. The optimal design of the airflow passage
features a small fan diameter to allow for a compact installation. Thanks to practical casing configuration, airflow
generated by the fan is uniformly distributed.
FLEXIBLE INSTALLATION
Refrigerant and drain piping can be connected from the rear, right, base, or left of the unit, providing much
greater flexibility for piping and selecting an installation site.
The PLFY Series ceiling cassettes provide exceptional performance and air coverage.
Available styles: the PLFY-P-VBM, PLFY-P-VCM and PLFY-P-VLMD. These models can be
accessorized with installation trim panels (PLFY-ITP1 and PLFY-ITP2) to ensure seamless
integration into suspended ceilings.
PLFY-P-VBM-E
KEY FEATURES
▶▶ 33" x 33" cabinet size
▶▶ Capacity range of 8,000 to 48,000 Btu/h
▶▶ Sound levels as low as 27 dB(A)
▶▶ Ventilation air connection (Second connection found in Multi-function Casement)
▶▶ High-efficiency filter option (MERV-10 requires Multi-function Casement)
▶▶ Branch ducting capability
▶▶ Four-speed fan settings
▶▶ Integrated condensate lift mechanism to provide up to 33-7/16" of lift
PLFY-P-VCM-E
KEY FEATURES
PLFY-P-VLMD-E
KEY FEATURES
24
INDOOR UNITS
Benefits
QUIET OPERATION
This powerful indoor unit is whisper–quiet down to 27 dB(A) 4-, 3-, OR 2-WAY AIRFLOW
26
INDOOR UNITS
KEY FEATURES
▶▶ The PMFY is available in 7,500, 9,600, 12,300, and 15,400 BTU/h
▶▶ Standardized cabinet size for all models: 32"
▶▶ Airflow control technology operates as low as 27 dB(A) for
industry-leading quiet performance
▶▶ Integrated condensate lift mechanism to provide up to 23-5/8" of lift
▶▶ Full unit access through the front cover panel
Benefits
QUIET OPERATION
Specialized airflow control technology operates as
DRAIN MECHANISM
low as 27 dB(A) for industry-leading sound performance.
MITSUBISHI
MITSUBISHI ELECTRIC
ELECTRIC Cooling
Cooling && Heating
Heating / /CITY
CITYMULTI
MULTI/ 27
/ 27
PCFY (Ceiling–suspended)
The PCFY model features powerful air throw to cover entire spaces quietly and efficiently.
KEY FEATURES
▶▶ Available in 15,400, 24,200, 38,200, and 47,800 Btu/h capacities
▶▶ Auto-vane and wide-range outlet provides uniformly distributed
conditioned air to all corners of the room
▶▶ Four-speed fan settings
▶▶ Accessory filters are available to increase filtration effectiveness
▶▶ Optional pump kit is available for condensate removal
Benefits
▶▶ Measures infrared rays generated from surrounding suspension bolts and the durable attachment fixture.
walls and surface angles An optional pump kit is available to dispose
▶▶ Rotates 90 degrees in five-second intervals of condensate.
▶▶ Efficiently adjusts temperatures to ideal comfort
levels for occupants
28
INDOOR UNITS
The PEFY models are high-performance, ceiling-concealed, ducted indoor units. An excellent
choice for office buildings, schools, hotels, assisted living facilities and other applications
where ceiling space is available.
KEY FEATURES
▶▶ External static pressure settings are adjustable to meet varying application conditions
▶▶ Choice of fan speed settings
▶▶ Side access to control panel
▶▶ Integrated condensate lift mechanism (low-static, mid-static and VMH-E models)
QUIET OPERATION
The specially-designed centrifugal fan provides exceptionally quiet operation, even at high operating speeds.
30
INDOOR UNITS
KEY FEATURES
▶▶Rated Class 2 under UL Standard 900
▶▶Cabinet is constructed of non-insulated 20 gauge G–60 galvanized steel
▶▶Foam gasket provides airtight connection to indoor unit and access door
▶▶Return connection in rear can be easily field converted to bottom
Part Number Used on CITY MULTI Models Filters Included Net Weight (lbs.)
Part Number Used on CITY MULTI Models Filters Included Net Weight (lbs.)
Part Number Used on CITY MULTI Models Filters Included Net Weight (lbs.)
FBH2-2 PEFY-P27, P30-NMHU (1) — 20" x 16" x 2", (1) — 20" x 20" x 2" 24
MITSUBISHI
MITSUBISHI ELECTRIC
ELECTRIC Cooling
Cooling && Heating
Heating / /CITY
CITYMULTI
MULTI/ 31
/ 31
PFAV SERIES
PFAV series is a large-capacity floor-standing indoor unit with high airflow operation specially
designed for various types of large spaced application. The unit features a one-to-one
connection, meaning one indoor is connected to one outdoor unit. The lineup consists of two
models: standard model and fresh air intake model, selectable depending on usage.
OUTDOR UNITS
COMPACT OUTDOOR UNIT
PFAV-Series can only be connected to PUHY-YJM outdoor
units. The high heating capacity YJM Series offers a
small footprint and lightweight design, allowing easy Installation space 1.43m
transportation and saving installation space. Height
1650mm 200kg
(without legs)
HIGH RELIABILITY
Outdoor heat exchangers have been treated with an anti- Depth 2
Width 760mm
corrosion coating ensuring higher resistance against salt 920mm
LOCKING FUNCTION
To sustain optimal temperature and prevent operational errors, buttons can be locked to only On/Off control.
32
INDOOR UNITS
100 100
COOLING HEATING
80 80
relative humidity (%)
40 40
20 20
10 15 20 25 30 35 -10 02 10 0 30 40
Inlet air temperature (°CDB) Inlet air temperature (°CDB)
100 100
COOLING HEATING
80 80
relative humidity (%)
60 60
40 40
20 20
15 20 25 30 35 40 45 -10 02 10 0 30 40
Inlet air temperature (°CDB) Inlet air temperature (°CDB)
PFFY floor-standing models are available as exposed or concealed indoor units. At less than
nine inches deep, these units are easy to install in peripheral spaces, yet offer highly efficient
cooling and heating performance. Their low operating sound and compact size make them ideal
for hotel rooms, schools and office buildings.
KEY FEATURES
▶▶ Designed for applications requiring a built-in,
concealed, floor-standing unit
▶▶ The PFFY-P-VLRM unit can be field converted from top discharge
to front discharge
PFFY-P-VLRM
Exposed Type
Benefits
INSTALLATION FLEXIBILITY
The PFFY-P-VLRM-E unit can be field converted
from top discharge to front discharge to increase
installation flexibility.
34
VENTILATION
PremiSys DOAS/Lossnay Energy Recovery Ventilators (ERVs)/DOAS
The PremiSys series of rooftop ventilation products is a premier solution for conditioning
outdoor air for commercial buildings. Designed to handle 100% outdoor air with optional
energy recovery, PremiSys products offer premium features ideal for handling ventilation
air in variable refrigerant flow (VRF) applications.
The PremiSys models MP and MPE (with energy recovery), are pre-engineered to
provide semi-custom flexibility while maintaining the quality, consistency, and value
of a standardized product.
Nominal Nominal
Condensing Outdoor Supply Exhaust
Unit Size Tonnage Height Width Length Intake Weight
Section Intake Discharge Discharge
(tons) (lbs)
MP-1 5 – 15 59 53 99 22 30 2,700
Bottom
MP-2 15 – 30 73 68 109 27 30 4,500 End or N/A
Side
MP-4 20 – 43 90 68 156 22/27 30 6,400
MPE-1 5 – 15 59 53 150 22 30 3,400
Bottom
MPE-2 15 – 30 73 68 163 27 30 5,100 End or Side
Side
MPE-4 20 – 43 90 68 224 22/27 30 8,300
36
VENTILATION
PREMISYS® FUSION
The PremiSys series of rooftop ventilation products are a premier solution for conditioning
outdoor air for commercial buildings. Designed to handle 100% outdoor air with energy recovery
models, PremiSys products offer premium features ideal for handling ventilation air in
VRF applications.
The PremiSys Fusion is the latest addition to the family of dedicated outdoor air systems.
The MPF-1 and MPF-2 (split system with energy recovery) models are pre-engineered to provide
semi-custom flexibility while maintaining the quality, consistency, and value of a standardized
product. Take advantage of the split-system design to further enhance the flexibility of applying
Mitsubishi Electric products to any building.
Nominal
Condensing Nominal Outdoor Supply Exhaust
Unit Size Tonnage Height Width Length Intake
Section Weight (lbs) Intake Discharge Discharge
(tons)
KEY FEATURES
▶▶ Lossnay core
▶▶ Over 50% enthalpy exchange efficiency
▶▶ Four fan speeds (300, 470, and 600 models): extra low, low, high,
extra high
▶▶ M-NET connectivity for use with CITY MULTI central controllers
and BMS interfaces
▶▶ Sound pressure level: maximum sound level 40.5 dB(A)
▶▶ Three ventilation modes: Auto, Bypass, Heat Recovery
Benefits
The LGH-F-RX5 series is fully compatible with our mode is available without the use of other parts. An
controls network, further increasing the scope of total automatic mode allows the system to select recovery
38
VENTILATION
The award-winning PEFY–AF Dedicated Outside Air System comes in two configurations,
the CFM and the CFMR. Both configurations offer high capacity coils that will condition
incoming air, making it suitable for distribution to downstream fan coil units.
KEY FEATURES
CFM
40
MITSUBISHI ELECTRIC Cooling & Heating / CITY MULTI / 41
CONTROLS NETWORK
Benefits
EASY INSTALLATION
The CMCN uses simple, non-polar, two-wire control connections. All components are daisy-chained and added onto the
M-NET communication bus. It all adds up to less labor and materials with a quicker installation.
ENERGY ALLOCATION
A centralized controller network configured with the energy allocation option and watt-hour meter(s) can calculate the
HVAC energy consumption relative to each indoor unit on a per-tenant basis and generate a CITY MULTI energy allocation
per tenant. The Energy Allocation feature is available through the AE-200A/AE-50A/EW-50A centralized controllers.
SYSTEM INTEGRATION
Not only can our CMCN act as a standalone building management system, it can also integrate with existing systems via
LonWorks® or BACnet®.
42
CITY MULTI CONTROLS
The Integrated Centralized Control Web (ICCW) enables the user to control multiple AE-200A/
AE‑50A /EW-50A centralized controllers and provide enhanced functions from any networked PC,
tablet or smartphone. ICCW is capable of controlling up to 2,000 indoor units in conjunction with our
centralized controllers.
ENERGY ALLOCATION
KEY FEATURES
▶▶ Allocates the energy cost of the outdoor unit(s)
power consumption to building tenants based
on the capacity used by their indoor units
▶▶ Great for condos and multiple tenant spaces
▶▶ Requires a software license (SW-Charge)
TABLET SMARTPHONE
Centralized controllers support operations that supersede simple control of the HVAC system
and include system configuration, scheduling, batch operation, and malfunction monitoring
through license options. These license options further expand the functionality of our centralized
controller offerings.
OPTIONAL LICENSES
44
CITY MULTI CONTROLS
AE-200A
M–NET M–NET
50
units
M–NET
50
ETHERNET AE-50A units Total
200
units
M–NET
50
units
AE-50A
M–NET
50
units
AE-50A
M–NET M–NET
AE-50A
ETHERNET
AE-200A
STANDARD FEATURES
Function Description
Up to 200 indoor units can be controlled and monitored when three expansion controllers
Max No. of Indoor Units
(AE-50A and/or EW-50A) are networked together
46
CITY MULTI CONTROLS
The EW-50A is a web browser-only centralized controller for managing CITY MULTI and peripheral
systems. The EW-50A can also connect to an AE-200A over Ethernet to expand its monitoring
capability to up to 200 indoor units when three EW-50A units are used.
The EW-50A features advanced functionality with expanded monitoring, control, dual set point
and trending abilities.
M–NET
M–NET
Max
50
units
EW-50A
AE-200A
M–NET
EW-50A
M–NET Max
50
units
STANDARD FEATURES
FUNCTION DESCRIPTION
Max No. of Indoor Units Up to 50 indoor units can be controlled and monitored
CITY MULTI compressor speed and hi/low pressure/AdvancedHVAC Controller (DC-AIO) input/output status/Space
Displays temperature and humidity (from SmartME or AI controller)/Error code (four-digit code and the affected unit address)/Unoc-
cupied setback temperature range/Occupancy and brightness status from the SmartME remote controller
Temperature Setting Supports single and dual set point operation with extended set temperature range
Fan Speed Setting Hi/Mid–2/Mid–1/Low/Auto (Available fan speed settings depending on indoor unit)
Airflow Direction Setting Swing/Horizontal/Mid-0/Mid-1/Mid-2/Mid-3/Auto (settings vary depending on indoor unit model)
Individual prohibit operations for each remote controller function include ON/OFF/Set Temperature/Fan Speed
Permit/Prohibit Function
Direction/Operation Mode/Filter Reset
Inputs: Level Signal–Batch Start/Stop, Batch Emergency Stop Outputs: Start/Stop Status, Error/Normal Status
External Input/Output
(requires PAC-YG10HA)
Trending Data Fan operation time/Thermo-on time/Set temperature/Room temperature/AI controller temperature and humidity
M–NET
DIDO Board
TC–24B PAC–SC51KUA
STANDARD FEATURES
Function Description
Temperature Setting Supports single and dual set point modes/Set temperature from 57˚ F – 87˚ F depending on operation mode and indoor unit
Fan Speed Setting Hi/Mid–2/Mid–1 /Low/Auto (Available fan speed settings depending on indoor unit)
Airflow Direction Setting Airflow angles: 100˚ – 80˚ – 60˚ – 40˚ and swing/Airflow direction settings vary depending on indoor unit model
Permit/Prohibit Function Individual prohibit operations for each remote controller function (ON/OFF, Set Temperature, Operation Mode and Filter Reset)
Indoor Return Air Temperature Displays the measured return air temperature from each group
Error Indication Displays a four-digit code and the affected unit address
Schedule Operation Weekly schedule can be set by groups based on operation pattern
External Input/Output Inputs: Level Signal–Batch Start/Stop, Batch Emergency Stop Outputs: Start/Stop Status, Error/Normal Status
48
CITY MULTI CONTROLS
INPUT/OUTPUT CONTROLLERS
STANDARD FEATURES
Function Description
Display Displays measurement data via AE-200A, AE-50A, and EW-50A web browser
Fail-safe Device An internal capacitor will continue to track time for one week in the event of a power failure
Communication M–NET
ETHERNET M–NET
PAC–YG60MCA e50b
AE-200A PAC–YG66DCA
STANDARD FEATURES
Function Description
Inputs Qty two Digital Status Inputs and 2 Digital Error Inputs (Non–Voltage Contacts)
Outputs Qty two Digital Outputs (Non–Voltage Relay Contact | Use only VDC with outputs
Monitor Status, Fault | Requires AE-200A, AE-50A, EW-50A, or TC–24B Centralized Controller
Control On/Off, Start/Stop, Enable/Disable | Requires AE-200A, AE-50A, EW-50A, or TC–24B Centralized Controller
Schedule Operation Weekly schedule can be set by groups based on operation pattern
Requires AE-200A, AE-50A, EW-50A, or TC–24B Centralized Controller
Interlock Function Interlock M–NET devices and output contacts according to status of input contacts
Communication M–NET
ETHERNET M–NET
PAC–YG63MCA e50b
AE-200A PAC–YG66DCA
STANDARD FEATURES
Function Description
Inputs Qty two Analog Inputs (0/10 VDC, 4/20 mA, 1–5 VDC)
Interlock Function Interlock M–NET devices and output contacts according to measured values on inputs
Alarms Generate alarm based on user defined high and low limits
Communication M–NET
50
CITY MULTI CONTROLS
ZONE CONTROLLERS
SMARTME
KEY FEATURES
▶▶ Intuitive backlit touchscreen
▶▶ Group controls up to 16 indoor units in a single zone
▶▶ Onboard temperature, humidity, occupancy, and brightness sensors
▶▶ Monitors third-party equipment through AdvancedHVAC controller
▶▶ Supports dual set point and setback functions
PAR-U01MEDU
▶▶ Improved scheduling
▶▶ Color glow status indicator LED bar
▶▶ Dimensions (H x W x D): 4-3/4" x 5-9/16" x 1"
Smart ME Smart ME
AE-200A Controller Controller
The LED bar indicates the operation status by lighting and OCCUPANCY SENSOR
blinking with different colors and brightness (High/Low), or by The built-in Occupancy Sensor is used to detect movement
turning off. Multiple operation status indicators include blue in a room. If the sensor detects no motion or vacancy, it will
(Cooling), light blue (Drying), yellow (Fan), white (Auto), green activate the selected Energy Saving Function mode. The
(Setback), red (Heating) and lime (Energy Save). Advanced Occupancy Sensor returns the system to original operating
settings are available for selecting the desired color per mode, status after detecting movement. The user can adjust the
LED brightness (in conjunction with room brightness sensor), away time and detection sensitivity threshold level for
and temperature range indicator. the Occupancy Sensor. Brightness can also be used in
conjunction with motion to determine occupancy.
Wired remote controller ideal for easy operation, convenience, and energy savings
KEY FEATURES
▶▶ Controls up to 16 zones
▶▶ Large easy-to-see backlit LCD with two display modes:
Full or Basic
▶▶ Interlock and control Lossnay units
▶▶ Operation modes: Auto, Cool, Heat, Dry, Fan
▶▶ Fan speed settings
▶▶ Controls air direction (vane direction and ventilation)
PAR-33MAA ▶▶ Dimensions: 4-3/4" x 3/4" x 4-3/4"
▶▶ Dual set point functionality
▶▶ Daylight Saving Time (DST) included
SIMPLE MA
M-NET
KEY FEATURES
▶▶ Controls up to 16 zones
▶▶ Backlit LCD
▶▶ Operation modes of Cool, Heat, Simple MA
remote
Dry, Fan, Auto, Ventilation, Setback controller
52
CITY MULTI CONTROLS
ZONE CONTROLLERS
KEY FEATURES
▶▶ Handheld wireless remote control of up to 16 indoor units
▶▶ Operation modes of Cool, Heat, Dry, Fan, Auto, Ventilation
▶▶ Fan speed, airflow direction settings
▶▶ Compatible with P-Series and CITY MULTI systems
▶▶ Requires PAR-FA32MA Wireless Receiver. (Built-in as standard on PKFY models)
PAR-FL32MA
▶▶ Dimensions — Remote: 2-5/16" x 3/4" x 5-1/4"
Receiver: 2-3/4" x 7/8" x 4-12/16"
kumo cloud®
KEY FEATURES
▶▶ Compatible with CITY MULTI, M-Series and P-Series systems without
a central controller
▶▶ Requires the Mitsubishi Electric Wireless Interface (PAC-USWHS002-WF-1)
▶▶ Easy to connect the device to your router using the kumo cloud app
▶▶ App compatible software platforms:
Apple iOS 8.0 or later
Android 4.1 or later
Fire OS 4.1 or later
▶▶ Intuitive settings for simplified use:
Group units together
Organize groups into sites
Batch command units
▶▶ Error and filter status pop-up
▶▶ Advanced functions settings for M-Series and P-Series equipment
AdvancedHVAC Controller
The AdvancedHVAC controller features customizable applications for integrating CITY MULTI indoor units with
third-party equipment. Physical inputs and outputs can be used for reading sensors and energizing relays.
An analog output accessory can be added for modulating third-party equipment signals. Status of inputs and
outputs are displayed on the AE-200A, AE-50A, EW-50A web browser and the PAR-U01MEDU SmartME Remote
Controller screen.
54
CITY MULTI CONTROLS
SYSTEM INTEGRATION
The CMCN supports integration with Building Management Systems (BMS) via
LonWorks® and BACnet®
The Mitsubishi Electric LonWorks® interface, LMAP04U, supports up to 50 indoor units with a variety of network
variables on a per indoor unit basis. Input variables include, but are not limited to: On/Off, Operation Mode, Fan
Speed, Prohibit Remote Controller, and Filter Sign Reset. Output variables include but are not limited to: Model
Size, Alarm State, Error Code, and Error Address.
LONWORKS® INTERFACE
KEY FEATURES
▶▶ Up to 50 units (CITY MULTI, M-Series, P-Series and/or Lossnay) can
be connected with one LonWorks interface
▶▶ O
peration/Setting: Request On/Off, Set Point, Request Lossnay
Mode, Request Fan Speed, Request Local Prohibit On/Off and Set
Point, Request Forced Thermostat Off, Filter Sign Reset, Time Stamp,
Request Limit Temperature Setting Range, Request Simplified Locking
▶▶ Features a built-in power supply (208/230 VAC)
▶▶ Dimensions: 13-7/16" x 14-3/16" x 2-3/8"
The AE-200A/AE-50A/EW-50A centralized controllers are BTL® (BACnet Testing Laboratories) listed,
demonstrating their compliance with ASHRAE standards and their compatibility with building management
systems supporting the BACnet TCP/IP communication protocol.
BACNET® LICENSE
KEY FEATURES
▶▶ Connect up to 50 indoor units per licensed controller
▶▶ Supports the monitoring and operation of CITY MULTI indoor units, M-Series and P-Series
indoor units (requires additional adapter), and Lossnay ERV units
▶▶ BACnet TCP/IP
▶▶ Licensed feature of the centralized controller
PROJECT PROPERTIES
56
CITY MULTI CONTROLS
DSB INTERFACE
Optional functions to customize the system layout to your project are available, such as labeling groups with
a room name, adding equipment tags to pieces of equipment, and giving each system a project-specific
name. Other features, like a custom equipment schedule, submittal packages, and AutoCAD drawings are
available once the system layout has been finalized.
Use Maintenance Tool software to monitor pressure and temperature readings from CITY MULTI system sensors, display
and control system LEV settings, and display and remotely control all connected indoor units. Maintenance Tool software
also allows the technician to record and save system operational data for the purposes of trending and system analysis
off‑site as well as display malfunction logs and email error reports to personnel responsible for servicing the system.
MN CONVERTER
KEY FEATURES
▶▶ Allows technicians to monitor and collect CITY MULTI system data and
control various functions
CMS–MNG–E
▶▶ System monitoring accomplished through direct connection
between your PC and the M-NET bus line using the MN-Converter
The mode select screen allows the user to select the The operation status monitor screen displays the operational
method for connection to the CITY MULTI system, data for the connected system, including system pressures,
whether direct or remotely, or choose to analyze temperatures, LEV settings, compressor frequency, current
previously recorded data offline. operational mode, and more. Pre-recorded data can also be
viewed in an off-line version of this screen.
58
SPECIFICATION TABLES
Notes:
*1,*2 Nominal conditions
Indoor Outdoor Pipe length Level difference
27ºC DB/19ºC WB 35ºC DB/24ºC WB
Cooling 7.5m (24-9/16ft.) 0m (0ft.)
(81ºF DB/66ºF WB) (95ºF DB/75ºF WB)
Heating 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (24-9/16ft.) 0m (0ft.)
Notes:
*1,*2 Nominal conditions
*3 External static pressure option is available (0.12 in. WC, 0.24 in. WC).
*Nominal condition *1,*2 are subject to JIS B8615-2.
*Due to continuing improvement, above specification may be subject to change without notice.
OUTDOOR UNIT
Y Series
PUHY-P YSKB-A1(-BS)
Notes:
*1,*2 Nominal conditions
Indoor Outdoor Pipe length Level difference
27ºC DB/19ºC WB 35ºC DB/24ºC WB
Cooling 7.5m (24-9/16ft.) 0m (0ft.)
(81ºF DB/66ºF WB) (95ºF DB/75ºF WB)
Heating 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (24-9/16ft.) 0m (0ft.)
*3 External static pressure option is available (0.12 in. WC, 0.24 in. WC ).
*Nominal condition *1,*2 are subject to JIS B8615-2.
*Due to continuing improvement, above specification may be subject to change without notice.
OUTDOOR UNIT
Y Series
PUHY-P YSKB-A1(-BS)
Notes:
*1,*2 Nominal conditions
*3 External static pressure option is available (0.12 in. WC, 0.24 in. WC).
*Nominal condition *1,*2 are subject to JIS B8615-2.
*Due to continuing improvement, above specification may be subject to change without notice.
OUTDOOR UNIT
Y Series
PUHY-P YSKB-A1(-BS)
Notes:
*3 External static pressure option is available (0.12 in. WC, 0.24 in. WC).
*Nominal condition *1,*2 are subject to JIS B8615-2.
*Due to continuing improvement, above specification may be subject to change without notice.
OUTDOOR UNIT
Y Series
PUHY-P YSKB-A1(-BS)
Notes:
*1,*2 Nominal conditions
*3 External static pressure option is available (0.12 in. WC, 0.24 in. WC).
*Nominal condition *1,*2 are subject to JIS B8615-2.
*Due to continuing improvement, above specification may be subject to change without notice.
OUTDOOR UNIT
Y Series
PUHY-P YSKB-A1(-BS)
Notes:
*3 External static pressure option is available (0.12 in. WC, 0.24 in. WC).
*Nominal condition *1,*2 are subject to JIS B8615-2.
*Due to continuing improvement, above specification may be subject to change without notice.
OUTDOOR UNIT
Y Series
PUHY-P YSKB-A1(-BS)
Notes:
*1,*2 Nominal conditions
Indoor Outdoor Pipe length Level difference
27ºC DB/19ºC WB 35ºC DB/24ºC WB
Cooling 7.5m (24-9/16ft.) 0m (0ft.)
(81ºF DB/66ºF WB) (95ºF DB/75ºF WB)
Heating 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (24-9/16ft.) 0m (0ft.)
*3 External static pressure option is available (0.12 in. WC, 0.24 in. WC).
*Nominal condition *1,*2 are subject to JIS B8615-2.
*Due to continuing improvement, above specification may be subject to change without notice.
OUTDOOR UNIT
Y Series
PUHY-P YSKB-A1(-BS)
Notes:
*1,*2 Nominal conditions
Indoor Outdoor Pipe length Level difference
27ºC DB/19ºC WB 35ºC DB/24ºC WB
Cooling 7.5m (24-9/16ft.) 0m (0ft.)
(81ºF DB/66ºF WB) (95ºF DB/75ºF WB)
Heating 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (24-9/16ft.) 0m (0ft.)
*3 External static pressure option is available (0.12 in. WC, 0.24 in. WC).
*Nominal condition *1,*2 are subject to JIS B8615-2.
*Due to continuing improvement, above specification may be subject to change without notice.
OUTDOOR UNIT
Y Series
PUHY-P YSKB-A1(-BS)
Notes:
*1,*2 Nominal conditions
Indoor Outdoor Pipe length Level difference
27ºC DB/19ºC WB 35ºC DB/24ºC WB
Cooling 7.5m (24-9/16ft.) 0m (0ft.)
(81ºF DB/66ºF WB) (95ºF DB/75ºF WB)
Heating 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (24-9/16ft.) 0m (0ft.)
*3 External static pressure option is available (0.12 in. WC, 0.24 in. WC).
*Nominal condition *1,*2 are subject to JIS B8615-2.
*Due to continuing improvement, above specification may be subject to change without notice.
OUTDOOR UNIT
Y Series
PUHY-P YSKB-A1(-BS)
Notes:
*1,*2 Nominal conditions
*3 External static pressure option is available (0.12 in. WC, 0.24 in. WC).
*Nominal condition *1,*2 are subject to JIS B8615-2.
*Due to continuing improvement, above specification may be subject to change without notice.
OUTDOOR UNIT
Y Series
PUHY-P TKA(-BS)
Notes:
*1,*2 Nominal conditions
Notes:
*1,*2 Nominal conditions
Indoor Outdoor Pipe length Level difference
27ºC DB/19ºC WB
Cooling 35ºC DB(95ºF DB) 7.5m (24-9/16ft.) 0m (0ft.)
(81ºF DB/66ºF WB)
Heating 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (24-9/16ft.) 0m (0ft.)
Notes:
Notes:
Notes:
*1,*2 Nominal conditions
Notes:
*1,*2 Nominal conditions
Notes:
*1,*2 Nominal conditions
Notes:
*1,*2 Nominal conditions
Notes:
*1,*2 Nominal conditions
Notes:
*1,*2 Nominal conditions
in. 52-11/16 x 41-11/32 x 13 (+1) 52-11/16 x 41-11/32 x 13 (+1) 52-11/16 x 41-11/32 x 13 (+1)
Protection High pressure protection High pressure Switch High pressure Switch High pressure Switch
devices Inverter circuit (COMP./FAN) Overcurrent detection, Overheat detection Overcurrent detection, Overheat detection Overcurrent detection, Overheat detection
(Heatsink thermistor ) (Heatsink thermistor ) (Heatsink thermistor )
Compressor Compressor thermistor, Over current detection Compressor thermistor, Over current detection Compressor thermistor, Over current detection
Fan motor Overheating, Voltage protection Overheating, Voltage protection Overheating, Voltage protection
Refrigerant Type x original charge R410A 4.8kg R410A 4.8kg R410A 4.8kg
Net weight kg (lbs) 122(269) 122(269) 122(269)
Heat exchanger Cross Fin and Copper tube Cross Fin and Copper tube Cross Fin and Copper tube
Defrosting method Reversed refrigerant circuit Reversed refrigerant circuit Reversed refrigerant circuit
Optional parts Joint: CMY-Y62-G-E Joint: CMY-Y62-G-E Joint: CMY-Y62-G-E
Header: CMY-Y64/68-G-E Header: CMY-Y64/68-G-E Header: CMY-Y64/68-G-E
Branch box: PAC-MK32/52BC(B) Branch box: PAC-MK32/52BC(B) Branch box: PAC-MK32/52BC(B)
Notes:
*1,*2 Nominal conditions
Indoor Outdoor Pipe length Level difference
27ºC DB/19ºC WB
Cooling 35ºC DB(95ºF DB) 7.5m (24-9/16ft.) 0m (0ft.)
(81ºF DB/66ºF WB)
Heating 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (24-9/16ft.) 0m (0ft.)
in. 52-11/16 x 41-11/32 x 13 (+1) 52-11/16 x 41-11/32 x 13 (+1) 52-11/16 x 41-11/32 x 13 (+1) 52-11/16 x 41-11/32 x 13 (+1)
Protection High pressure protection High pressure Switch High pressure Switch High pressure Switch High pressure switch
devices Inverter circuit (COMP./FAN)
Overcurrent detection, Overheat Overcurrent detection, Overheat Overcurrent detection, Overheat Overcurrent detection, Overheat
detection (Heatsink thermistor) detection (Heatsink thermistor) detection (Heatsink thermistor) detection (Heatsink thermistor)
Compressor Compressor thermistor, Compressor thermistor, Compressor thermistor, Compressor thermistor,
Over current detection Over current detection Over current detection Over current detection
Fan motor Overheating, Voltage protection Overheating, Voltage protection Overheating, Voltage protection Overheating, Voltage protection
Refrigerant Type x original charge R410A 4.8kg R410A 4.8kg R410A 4.8kg R410A x 7.3kg
Net weight kg (lbs) 125(276) 125(276) 125(276) 137(303)
Heat exchanger Cross Fin and Copper tube Cross Fin and Copper tube Cross Fin and Copper tube Cross Fin and Copper tube
Defrosting method Reversed refrigerant circuit Reversed refrigerant circuit Reversed refrigerant circuit Reversed refrigerant circuit
Optional parts Joint: CMY-Y62-G-E Joint: CMY-Y62-G-E Joint: CMY-Y62-G-E Joint: CMY-Y62-G-E
Header: CMY-Y64/68-G-E Header: CMY-Y64/68-G-E Header: CMY-Y64/68-G-E Header: CMY-Y64/68-G-E
Branch box: PAC-MK32/52BC(B) Branch box: PAC-MK32/52BC(B) Branch box: PAC-MK32/52BC(B) Branch box: PAC-MK32/52BC
Notes:
*1,*2 Nominal conditions
Indoor Outdoor Pipe length Level difference
27ºC DB/19ºC WB
Cooling 35ºC DB(95ºF DB) 7.5m (24-9/16ft.) 0m (0ft.)
(81ºF DB/66ºF WB)
Heating 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (24-9/16ft.) 0m (0ft.)
PLFY-P VBM-E
Power source
Cooling capacity
*1
*1
kW
BTU/h
2.2
7,500
2.8
9,600
1-phase 220-240V 50Hz / 1-phase 220V 60Hz
3.6
12,300
4.5
15,400
5.6
19,100
*1 kW 2.5 3.2 4.0 5.0 6.3
Heating capacity
*1 BTU/h 8,500 10,900 13,600 17,100 21,500
PLFY-P20VBM-E PLFY-P25VBM-E PLFY-P32VBM-E PLFY-P40VBM-E PLFY-P50VBM-E
Power Cooling kW 0.03 0.03 0.03 0.04 0.04
Power source 1-phase 220-240V 50Hz / 1-phase 220V 60Hz
consumption Heating kW 0.02 0.02 0.02 0.03 0.03
*1 kW 2.2 2.8 3.6 4.5 5.6
Cooling capacity Cooling A 0.26 0.26 0.27 0.29 0.29
Current *1 BTU/h 7,500 9,600 12,300 15,400 19,100
Heating A 0.19 0.19 0.20 0.22 0.22
*1 kW 2.5 3.2 4.0 5.0 6.3
External finish Unit
Heating capacity Galvanized steel sheet
*1 BTU/h 8,500 10,900 13,600 17,100 21,500
(Munsell No.) Panel MUNSELL (6.4Y 8.9/0.4)
Power Cooling kW 0.03 0.03 0.03 0.04 0.04
Dimension Unit mm(in.) 258 x 840 x 840 (10-3/16 x 33-1/8 x 33-1/8)
Hconsumption
xWxD Heating kW 0.02 0.02 0.02 0.03 0.03
Panel mm(in.) 35 x 950 x 950 (1-3/8 x 37-7/16 x 37-7/16)
Cooling A 0.26 0.26 0.27 0.29 0.29
Current Unit kg(lbs.) 22 (49)
Net weight Heating A 0.19 0.19 0.22
Panel kg(lbs.) 60.20
(13) 0.22
External finish Unit Galvanizedfin steel
Heat exchanger Cross fin (Aluminum andsheet
copper tube)
(Munsell No.) Panel MUNSELL (6.4Y 8.9/0.4)
Type x Quantity Turbo fan x 1
Dimension Unit mm(in.) 258 x 840 x 840 (10-3/16 x 33-1/8 x 33-1/8)
H x W x Airflow
D *2 m3/min 11-12-13-14 12-13-14-16
rate
Panel mm(in.) 35 x 950 x 950 (1-3/8 x 37-7/16 x 37-7/16)
Fan (Lo-Mid2-Mid1-Hi) L/s 183-200-217-233 200-217-233-267
Unit kg(lbs.) 22 (49)
Net weight cfm 388-424-459-494 424-459-494-565
kg(lbs.) 6 (13)
External staticPanel
pressure in. WC 0
Heat exchanger Cross fin (Aluminum fin and copper tube)
Type DC motor
Motor Type x Quantity Turbo fan x 1
Output kW 0.050
*2 m3/min 11-12-13-14 12-13-14-16
Air filter Airflow rate PP Honeycomb
Fan (Lo-Mid2-Mid1-Hi) L/s 183-200-217-233 200-217-233-267
Gas ø12.7 (ø1/2) / ø15.88 (ø5/8)
(Flare) mm(in.)
cfm 388-424-459-494 ø12.7 (ø1/2) 424-459-494-565
Refrigerant (Compatible)
External static pressure in. WC 0
pipe diameter Liquid ø6.35 (ø1/4) / ø9.52 (ø3/8)
Type (Flare) mm(in.) ø6.35 (ø1/4) DC motor
Motor (Compatible)
Output kW 0.050
Field drain pipe diameter mm(in.) O.D. 32 (1-1/4)
Air filter PP Honeycomb
Sound pressure level *2 *3
dB(A) 27-28-29-31 27-28-30-31
ø12.7 (ø1/2) / ø15.88 (ø5/8)
(Lo-Mid2-Mid1-Hi) Gas mm(in.) ø12.7 (ø1/2)
Refrigerant (Flare) (Compatible)
pipe diameter Liquid ø6.35 (ø1/4) / ø9.52 (ø3/8)
(Flare) mm(in.) PLFY-P63VBM-E PLFY-P80VBM-E PLFY-P100VBM-E
ø6.35 (ø1/4) PLFY-P125VBM-E
(Compatible)
Power source 1-phase 220-240V 50Hz / 1-phase 220V 60Hz
Field drain pipe diameter mm(in.) O.D. 32 (1-1/4)
*1 kW 7.1 9.0 11.2 14.0
Cooling capacity
Sound pressure level *2 *3
*1 dB(A)
BTU/h 24,200 30,700
27-28-29-31 38,200 47,800 27-28-30-31
(Lo-Mid2-Mid1-Hi)
*1 kW 8.0 10.0 12.5 16.0
Heating capacity
*1 BTU/h 27,300 34,100 42,700 54,600
PLFY-P63VBM-E PLFY-P80VBM-E PLFY-P100VBM-E PLFY-P125VBM-E
Power Cooling kW 0.05 0.07 0.15 0.16
Power source 1-phase 220-240V 50Hz / 1-phase 220V 60Hz
consumption Heating kW 0.04 0.06 0.14 0.15
*1 kW 7.1 9.0 11.2 14.0
Cooling capacity Cooling A 0.36 0.51 1.00 1.07
Current *1 BTU/h 24,200 30,700 38,200 47,800
Heating A 0.29 0.43 0.94 1.00
*1 kW 8.0 10.0 12.5 16.0
External finish Unit
Heating capacity Galvanized steel sheet
*1 BTU/h 27,300 34,100 42,700 54,600
(Munsell No.) Panel MUNSELL (6.4Y 8.9/0.4)
Power Cooling kW 0.05 0.07 0.15 0.16
Dimension Unit mm(in.) 258 x 840 x 840 (10-3/16 x 33-1/8 x 33-1/8)
Hconsumption
xWxD Heating kW 0.04 0.06 0.14 0.15
Panel mm(in.) 35 x 950 x 950 (1-3/8 x 37-7/16 x 37-7/16)
Cooling A 0.36 0.51 1.00 1.07
Current Unit kg(lbs.) 23 (51) 27 (60)
Net weight Heating A 0.29 0.43 0.94 1.00
Panel kg(lbs.) 6 (13)
External finish Unit
Heat exchanger Cross fin Galvanized steel
(Aluminum fin andsheet
copper tube)
(Munsell No.) Panel MUNSELL (6.4Y 8.9/0.4)
Type x Quantity Turbo fan x 1
Dimension Unit mm(in.) 258 x 840 x 840 (10-3/16 x 33-1/8 x 33-1/8)
H x W x Airflow
D *2 m3/min 14-15-16-18 16-18-20-22 21-24-27-29 22-25-28-30
rate
Panel mm(in.) 35 x 950 x 950 (1-3/8 x 37-7/16 x 37-7/16)
Fan (Lo-Mid2-Mid1-Hi) L/s 233-250-267-300 267-300-333-367 350-400-450-483 367-417-467-500
Unit kg(lbs.) 23 (51) 27 (60)
Net weight cfm 494-530-565-636 565-636-706-777 742-848-953-1024 777-883-989-1059
kg(lbs.) 6 (13)
External staticPanel
pressure Pa 0
Heat exchanger Cross fin (Aluminum fin and copper tube)
Type DC motor
Motor Type x Quantity Turbo fan x 1
Output kW 0.050 0.120
*2 m3/min 14-15-16-18 16-18-20-22 21-24-27-29 22-25-28-30
Air filter Airflow rate PP Honeycomb
Fan (Lo-Mid2-Mid1-Hi) L/s 233-250-267-300 267-300-333-367 350-400-450-483 367-417-467-500
Gas ø15.88 (ø5/8) / ø19.05 (ø3/4)
(Flare) mm(in.)
cfm ø15.88 (ø5/8)
494-530-565-636 565-636-706-777 742-848-953-1024 777-883-989-1059
Refrigerant (Compatible)
External static pressure Pa 0
pipe diameter Liquid
Type (Flare) mm(in.) ø9.52 (ø3/8)
DC motor
Motor
Output kW 0.050 0.120
Field drain pipe diameter mm(in.) O.D. 32 (1-1/4)
Air filter PP Honeycomb
Sound pressure level *2 *3
dB(A) 28-29-30-32 30-32-35-37 ø15.88 (ø5/8) / ø19.0535-38-41-43
34-37-39-41 (ø3/4)
(Lo-Mid2-Mid1-Hi) Gas mm(in.) ø15.88 (ø5/8)
Refrigerant (Flare) (Compatible)
pipe diameter Liquid
(Flare) mm(in.) ø9.52 (ø3/8)
Notes:
*1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.
Cooling : Indoor 27°C(81°F)DB/19°C(66°F)WB,Outdoor 35°C(95°F)DB
Heating : Indoor 20°C(68°F)DB,Outdoor 7°C(45°F)DB/6°C(43°F)WB
*2 Airflow rate/Sound pressure level are in (Lo-Mid-Hi) or (Lo-Mid1-Mid2-Hi).
Notes:
*3 It is measured in anechoic room at power source 230V.
*1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.
Cooling : Indoor 27°C(81°F)DB/19°C(66°F)WB,Outdoor 35°C(95°F)DB
Heating : Indoor 20°C(68°F)DB,Outdoor 7°C(45°F)DB/6°C(43°F)WB
84
*2 Airflow rate/Sound pressure level are in (Lo-Mid-Hi) or (Lo-Mid1-Mid2-Hi).
PLFY-P VLMD-E
Power source
PLFY-P20VLMD-E PLFY-P25VLMD-E PLFY-P32VLMD-E
1-phase 220-240V 50Hz / 1-phase 220-230V 60Hz
PLFY-P40VLMD-E
Notes:
*1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.
Cooling : Indoor 27°C(81°F)DB/19°C(66°F)WB,Outdoor 35°C(95°F)DB
Heating : Indoor 20°C(68°F)DB,Outdoor 7°C(45°F)DB/6°C(43°F)WB
PMFY-P VBM-E
Power source
PMFY-P20VBM-E PMFY-P25VBM-E PMFY-P32VBM-E
1-phase 220-240V 50Hz / 1-phase 220V 60Hz
PMFY-P40VBM-E
Notes:
*1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.
Cooling : Indoor 27°C(81°F)DB/19°C(66°F)WB,Outdoor 35°C(95°F)DB
Heating : Indoor 20°C(68°F)DB,Outdoor 7°C(45°F)DB/6°C(43°F)WB
Notes: *2 Airflow rate/Sound pressure level are in (low-middle2-middle1-high).
*3 It is measured in anechoic room.
*1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.
Cooling : Indoor 27°C(81°F)DB/19°C(66°F)WB,Outdoor 35°C(95°F)DB
86
Heating : Indoor 20°C(68°F)DB,Outdoor 7°C(45°F)DB/6°C(43°F)WB
*2 Airflow rate/Sound pressure level are in (low-middle2-middle1-high).
INDOOR UNIT
Ceiling concealed type
PEFY-P VMS1(L)-E
Power source
PEFY-P15VMS1(L)-E PEFY-P20VMS1(L)-E PEFY-P25VMS1(L)-E PEFY-P32VMS1(L)-E PEFY-P40VMS1(L)-E PEFY-P50VMS1(L)-E PEFY-P63VMS1(L)-E
1-phase 220-240V 50Hz / 1-phase 220-240V 60Hz
*1 kW 1.7 2.2 2.8 3.6 4.5 5.6 7.1
Cooling capacity
*1 BTU/h 5,800 7,500 9,600 12,300 15,400 19,100 24,200
*1 kW 1.9 2.5 3.2 4.0 5.0 6.3 8.0
Heating capacity
*1 BTU/h 6,500 8,500 10,900 13,600 17,100 21,500 27,300
PEFY-P15VMS1(L)-E PEFY-P20VMS1(L)-E PEFY-P25VMS1(L)-E PEFY-P32VMS1(L)-E PEFY-P40VMS1(L)-E PEFY-P50VMS1(L)-E PEFY-P63VMS1(L)-E
Power *3 Cooling kW 0.05 [0.03] 0.05 [0.03] 0.06 [0.04] 0.07 [0.05] 0.07 [0.05] 0.09 [0.07] 0.09 [0.07]
Power source 1-phase 220-240V 50Hz / 1-phase 220-240V 60Hz
consumption Heating kW 0.03 [0.03] 0.03 [0.03] 0.04 [0.04] 0.05 [0.05] 0.05 [0.05] 0.07 [0.07] 0.07 [0.07]
*1 kW 1.7 2.2 2.8 3.6 4.5 5.6 7.1
Cooling capacityCooling A 0.42 [0.31] 0.47 [0.36] 0.50 [0.39] 0.50 [0.39] 0.56 [0.45] 0.67 [0.56] 0.72 [0.61]
Current *3 *1 BTU/h 5,800 7,500 9,600 12,300 15,400 19,100 24,200
Heating A 0.31 [0.31] 0.36 [0.36] 0.39 [0.39] 0.39 [0.39] 0.45 [0.45] 0.56 [0.56] 0.61 [0.61]
*1 kW 1.9 2.5 3.2 4.0 5.0 6.3 8.0
External
Heating finish
capacity Galvanized
*1 BTU/h 6,500 8,500 10,900 13,600 17,100 21,500 27,300
Dimension mm 200 x 790 x 700 200 x 990 x 700 200 x 1,190 x 700
Power *3 Cooling kW 0.05 [0.03] 0.05 [0.03] 0.06 [0.04] 0.07 [0.05] 0.07 [0.05] 0.09 [0.07] 0.09 [0.07]
HxWxD In. 7-7/8 x 31-1/8 x 27-9/16 7-7/8 x 39 x 27-9/16 7-7/8 x 46-7/8 x 27-9/16
consumption Heating kW 0.03 [0.03] 0.03 [0.03] 0.04 [0.04] 0.05 [0.05] 0.05 [0.05] 0.07 [0.07] 0.07 [0.07]
Net weight *3 kg(lbs.) 19(42) [18(40)] 20(45) [19(42)] 24(53) [23(51)] 28(62) [27(60)]
Cooling A 0.42 [0.31] 0.47 [0.36] 0.50 [0.39] 0.50 [0.39] 0.56 [0.45] 0.67 [0.56] 0.72 [0.61]
HeatCurrent
exchanger *3 Cross fin (Aluminium fin and copper tube)
Heating A 0.31 [0.31] 0.36 [0.36] 0.39 [0.39] 0.39 [0.39] 0.45 [0.45] 0.56 [0.56] 0.61 [0.61]
Type x Quantity Sirocco fan x 2 Sirocco fan x 3 Sirocco fan x 4
External finish Galvanized
m3/min 5-6-7 5.5-6.5-8 5.5-7-9 6-8-10 8-9.5-11 9.5-11-13 12-14-16.5
Airflow rate
Dimension mm 200 x 790 x 700 200 x 990 x 700 200 x 1,190 x 700
Fan L/s 83-100-117 91-108-133 91-117-150 100-133-167 133-158-183 158-183-217 200-233-275
H x(Lo-Mid-Hi)
WxD In. 7-7/8 x 31-1/8 x 27-9/16 7-7/8 x 39 x 27-9/16 7-7/8 x 46-7/8 x 27-9/16
cfm 176-212-247 194-229-282 194-247-317 212-282-353 282-335-388 335-388-459 424-494-583
Net weight *3 kg(lbs.) 19(42) [18(40)] 20(45) [19(42)] 24(53) [23(51)] 28(62) [27(60)]
External static press in. WC 5-15-35-50
Heat exchanger Cross fin (Aluminium fin and copper tube)
type DC motor
Motor Type x Quantity Sirocco fan x 2 Sirocco fan x 3 Sirocco fan x 4
output kW 0.096
m3/min 5-6-7 5.5-6.5-8 5.5-7-9 6-8-10 8-9.5-11 9.5-11-13 12-14-16.5
Air filter Airflow rate PP Honeycomb fabric (washable)
Fan L/s 83-100-117 91-108-133 91-117-150 100-133-167 133-158-183 158-183-217 200-233-275
Refrigerant Gas (Lo-Mid-Hi) mm(in.) ø12.7 (ø1/2) Brazed ø15.88 (ø5/8) Brazed
pipe diameter Liquid cfm 176-212-247 194-229-282 194-247-317 212-282-353 282-335-388 335-388-459 424-494-583
mm(in.) ø6.35 (ø1/4) Brazed ø9.52 (ø3/8) Brazed
External static press in. WC 5-15-35-50
Field drain pipe diameter mm(in.) O.D. 32 (1-1/4)
type DC motor
Sound pressure level
Motor
output kW 0.096
(Lo-Mid-Hi) dB<A> 22-24-28 23-25-29 24-26-30 24-27-32 28-30-33 30-32-35 30-33-36
Air filter PP Honeycomb fabric (washable)
(mesured in anechoic room)
Refrigerant Gas mm(in.) ø12.7 (ø1/2) Brazed ø15.88 (ø5/8) Brazed
pipe diameter Liquid mm(in.) ø6.35 (ø1/4) Brazed ø9.52 (ø3/8) Brazed
Field drain pipe diameter mm(in.) O.D. 32 (1-1/4)
Sound pressure level
(Lo-Mid-Hi) dB<A> 22-24-28 23-25-29 24-26-30 24-27-32 28-30-33 30-32-35 30-33-36
(mesured in anechoic room)
Notes:
*1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.
Cooling : Indoor : 27°CD.B./19°CW.B. (81°FD.B. / 66°FW.B.) Outdoor : 35°CD.B. (95°FD.B. )
Heating : Indoor : 20°CD.B. (68°FD.B.) Outdoor : 7°CD.B. / 6°CW.B. (45°FD.B. / 43°FW.B.)
Pipe length : 7.5m (24-9/16ft) Height difference : 0m (0ft)
Notes:
*2 The external static pressure is set to 15 Pa at factory shipment.
*3 [ *1 ]Cooling/Heating capacity indicates the maximum value at operation under the following condition.
is in case of PEFY-P15-63VMS1L-E
Cooling : Indoor : 27°CD.B./19°CW.B. (81°FD.B. / 66°FW.B.) Outdoor : 35°CD.B. (95°FD.B. )
Heating : Indoor : 20°CD.B. (68°FD.B.) Outdoor : 7°CD.B. / 6°CW.B. (45°FD.B. / 43°FW.B.)
MITSUBISHI ELECTRIC Cooling Pipe &length
Heating
: 7.5m/(24-9/16ft)
CITY MULTI /Height
87 difference : 0m (0ft)
PEFY-P VMA(L)-E
PEFY-P20VMA(L)-E PEFY-P25VMA(L)-E PEFY-P32VMA(L)-E PEFY-P40VMA(L)-E PEFY-P50VMA(L)-E
Power source 1-phase 220-230-240V 50 / 60Hz
Cooling capacity *1 kW 2.2 2.8 3.6 4.5 5.6
(Nominal) *1 BTU/h 7,500 9,600 12,300 15,400 19,100
Heating capacity *2 kW 2.5 3.2 4.0 5.0 6.3
(Nominal) *2 BTU/h 8,500 10,900 13,600 17,100 21,500
Power Cooling *3 kW 0.06 [0.04] 0.06 [0.04] 0.07 [0.05] 0.09 [0.07] 0.11 [0.09]
consumption Heating *3 kW 0.04 0.04 0.05 0.07 0.09
Cooling *3 A 0.53 [0.42] 0.53 [0.42] 0.55 [0.44] 0.64 [0.53] 0.74 [0.63]
Current
Heating *3 A 0.42 0.42 0.44 0.53 0.63
External finish Galvanized steel plate
mm 250 x 700 x 732 250 x 700 x 732 250 x 700 x 732 250 x 900 x 732 250 x 900 x 732
Dimension H x W x D
in. 9-7/8 x 27-9/16 x 28-7/8 9-7/8 x 27-9/16 x 28-7/8 9-7/8 x 27-9/16 x 28-7/8 9-7/8 x 35-7/16 x 28-7/8 9-7/8 x 35-7/16 x 28-7/8
Net weight kg(lbs) 23 (51) [22 (49)] 23 (51) [22 (49)] 23 (51) [22 (49)] 26 (58) [25 (56)] 26 (58) [25 (56)]
Heat exchanger Cross fin (Aluminum fin and copper tube)
Type x Quantity Sirocco fan x 1
m3/min 6.0 - 7.5 - 8.5 6.0 - 7.5 - 8.5 7.5 - 9.0 - 10.5 10.0 - 12.0 - 14.0 12.0 - 14.5 - 17.0
Airflow rate
L/s 100 - 125 - 142 100 - 125 - 142 125 - 150 - 175 167 - 200 - 233 200 - 242 - 283
Fan (Low-Mid-High)
cfm 212 - 265 - 300 212 - 265 - 300 265 - 318 - 371 353 - 424 - 494 424 - 512 - 600
External static
in. WC <0.14> - 0.2- <0.28>- <0.4>-<0.6> <0.14> - 0.2- <0.28>- <0.4>-<0.6> <0.14> - 0.2- <0.28>- <0.4>-<0.6> <0.14> - 0.2- <0.28>- <0.4>-<0.6> <0.14> - 0.2- <0.28>- <0.4>-<0.6>
pressure *4
Type DC motor
Motor
Output kW 0.085 0.085 0.085 0.085 0.085
Air filter PP honeycomb fabric.
Liquid (R410A) 6.35 (1/4) Brazed 6.35 (1/4) Brazed 6.35 (1/4) Brazed 6.35 (1/4) Brazed 6.35 (1/4) Brazed
mm(in.)
Refrigerant (R22,R407C) 6.35 (1/4) Brazed 6.35 (1/4) Brazed 6.35 (1/4) Brazed 6.35 (1/4) Brazed 9.52 (3/8) Brazed
pipe diameter Gas (R410A) 12.7 (1/2) Brazed 12.7 (1/20) Brazed 12.7 (1/20) Brazed 12.7 (1/20) Brazed 12.7 (1/2) Brazed
mm(in.)
(R22,R407C) 12.7 (1/2) Brazed 12.7 (1/20) Brazed 12.7 (1/20) Brazed 12.7 (1/2) Brazed 15.88 (5/8) Brazed
Field drain pipe diameter mm(in.) O.D.32 (1-1/4) O.D.32(1-1/4) O.D.32(1-1/4) O.D.32 (1-1/4) O.D.32 (1-1/4)
Sound pressure level (measured in anechoic room)
(Low-Mid-High) *3 *5 dB(A) 26-28-29 26-28-29 28-30-34 28-30-34 28-32-35
*3 *6 dB(A) 23-25-26 23-25-26 23-26-29 23-27-30 25-29-32
Notes:
Aux. duct
Indoor: 27°CDB/19°CWB(81°FDB/66°FWB), Outdoor: 35°CDB(95°FDB) duct attached to the unit and 1.5m
Pipe length: 7.5m(24-9/16ft.), Level difference: 0m(0ft.) below the unit.
*2 Nominal heating conditions Measurement location
Indoor: 20°CDB(68°FDB), Outdoor: 7°CDB/6°CWB(45°FDB/43°FWB)
Pipe length: 7.5m(24-9/16ft.), Level difference: 0m(0ft.) Aux. duct
*3 The values are measured at the rated external static pressure.
*4 The rated external static pressure is shown without < >.The factory setting *6 Measured in anechoic room with a 2m
is the rated value. air inlet duct and 2m air outlet 2m 2m
1.5m
PEFY-P VMH(S)-E
PEFY-P40VMH-E PEFY-P50VMH-E PEFY-P63VMH-E PEFY-P71VMH-E PEFY-P80VMH-E PEFY-P100VMH-E PEFY-P125VMH-E PEFY-P140VMH-E
Power source 1-phase 220-240V 50Hz / 1-phase 220-240V 60Hz
*1 kW 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0
Cooling capacity
*1 BTU/h 15,400 19,100 24,200 27,300 30,700 38,200 47,800 54,600
*1 kW 5.0 6.3 8.0 9.0 10.0 12.5 16.0 18.0
Heating capacity
*1 BTU/h 17,100 21,500 27,300 30,700 34,100 42,700 54,600 61,400
Power Cooling kW 0.19 / 0.23 0.24 / 0.30 0.26 / 0.33 0.32 / 0.40 0.48 / 0.58 0.48 / 0.59
consumption Heating kW 0.19 / 0.23 0.24 / 0.30 0.26 / 0.33 0.32 / 0.40 0.48 / 0.58 0.48 / 0.59
Cooling A 0.88 / 1.06 1.12 / 1.38 1.20 / 1.51 1.47 / 1.83 2.34 / 2.66 2.35 / 2.70
Current
Heating A 0.88 / 1.06 1.12 / 1.38 1.20 / 1.51 1.47 / 1.83 2.34 / 2.66 2.35 / 2.70
External finish Galvanized
mm 380 x 750 x 900 380 x 1,000 x 900 380 x 1,200 x 900
Dimension H x W x D
in. 15 x 29-9/16 x 35-7/16 15 x 39-3/8 x 35-7/16 15 x 47-1/4 x 35-7/16
Net weight kg(lbs.) 41 (91) 50 (111) 65 (144) 67 (148)
Heat exchanger Cross fin (Aluminum plate fin and copper tube)
Type x Quantity Sirocco fan x 1 Sirocco fan x 2
m3/min 10.0-14.0 13.5-19.0 15.5-22.0 18.0-25.0 26.5-38.0 28.0-40.0
Airflow rate
L/s 167-233 225-317 258-367 300-417 442-633 467-667
Fan (Lo-Hi)
cfm 353-494 477-671 547-777 636-883 936-1342 989-1413
External static 220V in.WC 0.2 - 0.4- 0.8
pressure *2 230,240V in. WC 0.4-0.6-0.8
Type 1-phase induction motor
Motor
Output *3 kW 0.08 0.12 0.14 0.18 0.26
Air filter (option) Synthethic fiber unwoven cloth filter (long life)
Gas
mm(in.) ø12.7 (ø1/2) ø15.88 (ø5/8)
Refrigerant (Flare)
pipe diameter Liquid
mm(in.) ø6.35 (ø1/4) ø9.52 (ø3/8)
(Flare)
Field drain pipe diameter mm(in.) O.D. 32 (1-1/4)
Sound pressure 220V dB(A) 27-34 32-38 32-39 35-41 34-42
level (Lo-Hi) *6 230,240V dB(A) 31-37 36-41 35-41 38-43 38-44
PCFY-P VKM-E
Notes:
*1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.
Cooling Indoor : 27°C(80.6°F)DB/19°C(66.2°F)WB,Outdoor 35°C(95°F)DB
Heating Indoor : 20°C(68°F)DB,Outdoor 7°C(44.6°F)DB/6°C(42.8°F)WB
90
INDOOR UNIT
Wall mounted type PKFY-P VBM-E PKFY-P VHM-E
PKFY-P VBM-E
PKFY-P VHM-E
PKFY-P VKM-E PKFY-P VKM-E
PKFY-P15VBM-E PKFY-P20VBM-E PKFY-P25VBM-E PKFY-P32VHM-E PKFY-P40VHM-E PKFY-P50VHM-E
Power source 1-phase 220-240V 50Hz / 1-phase 220V 60Hz
*1 kW 1.7 2.2 2.8 3.6 4.5 5.6
Cooling capacity
*1 BTU/h 5,800 7,500 9,600 12,300 15,400 19,100
*1 kW 1.9 2.5 3.2 4.0 5.0 6.3
Heating capacity
*1 BTU/h 6,500 8,500 10,900 13,600 17,100 21,500
Power Cooling *4 kW 0.04 0.04
consumption Heating kW 0.04 0.03
Cooling *4 A 0.20 0.40
Current
Heating A 0.20 0.30
External finish(Munsell No.) Plastic (1.0Y 9.2/0.2) Plastic (1.0Y 9.2/0.2)
Dimension H x W x D mm(in.) 295 x 815 x 225 (11-5/8 x 32-1/8 x 8-7/8) 295 x 898 x 249(11-5/8 x 35-3/8 x 9-13/16)
Net weight kg(lbs.) 10 (23) 13(29)
Heat exchanger Cross fin (Aluminum fin and copper tube)
Type x Quantity Line flow fan x 1
*2 m3/min 4.9-5.0-5.2-5.3 4.9-5.2-5.6-5.9 9-10-11 9-10.5-11.5 9-10.5-12
Airflow rate
Fan L/s 82-83-87-88 82-87-93-98 150-167-183 150-175-192 150-175-200
(Lo-Mid2-Mid1-Hi)
cfm 173-177-184-187 173-184-198-208 318-353-388 318-371-406 318-371-424
External static pressure in. WC 0
Type 1-phase induction motor DC motor
Motor
Output kW 0.017 0.030
Air filter PP Honeycomb
Gas ø12.7 (ø1/2) / ø15.88 (ø5/8)
mm(in.) ø12.7 (ø1/2)
Refrigerant (Flare) (Compatible)
pipe diameter Liquid ø6.35 (ø1/4) / ø9.52 (ø3/8)
mm(in.) ø6.35 (ø1/4)
(Flare) (Compatible)
Field drain pipe diameter mm(in.) I.D.16 (5/8)
Sound pressure level
dB(A) 29-31-32-33 29-31-34-36 34-37-41 34-38-41 34-39-43
(Lo-Mid2-Mid1-Hi) *2 *3
Notes:
*1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. *2 Airflow rate/Sound pressure level are in (low-middle2-middle1-high).
Cooling Indoor : 27°C(81°F)DB/19°C(66°F)WB,Outdoor 35°C(95°F)DB
Heating Indoor : 20°C(68°F)DB,Outdoor 7°C(45°F)DB/6°C(43°F)WB *3 It is measured in anechoic room.
PKFY-P63VKM-E PKFY-P100VKM-E
Power source 1-phase 220-230-240V 50Hz / 1-phase 220V 60Hz
*1 kW 7.1 11.2
Cooling capacity
*1 BTU/h 24,200 38,200
*1 kW 8.0 12.5
Heating capacity
*1 BTU/h 27,300 42,600
Power Cooling *4 kW 0.05 0.08
consumption Heating kW 0.04 0.07
Cooling *4 A 0.37 0.58
Current
Heating A 0.30 0.51
External finish(Munsell No.) Plastic (1.0Y 9.2/0.2)
Dimension H x W x D mm(in.) 365 x 1,170 x 295 (14-3/8 x 46-1/16 x 11-5/8)
Net weight kg(lbs.) 21 (46)
Heat exchanger Cross fin (Aluminum fin and copper tube)
Type x Quantity Line flow fan x 1
*2 m3/min 16-20 20-26
Airflow rate
Fan L/s 267-333 333-433
(Lo-Hi)
cfm 565-706 706-918
External static pressure in. WC 0
Type DC motor
Motor
Output kW 0.056
Air filter PP Honeycomb
Gas ø15.88 (ø5/8) / ø19.05 (ø3/4)
mm(in.) ø15.88 (ø5/8)
Refrigerant (Flare) (Compatible)
pipe diameter Liquid
mm(in.) ø9.52 (ø3/8)
(Flare)
Field drain pipe diameter mm(in.) I.D. 16(5/8)
Sound pressure level
dB(A) 39-45 41-49
(Lo-Hi) *2 *3
Notes:
*1 Cooling/heating capacity indicates the maximum value at operation under the following condition.
Cooling Indoor : 27°C(81°F)DB/19°C(66°F)WB, Outdoor : 35°C(95°F)DB
Heating Indoor : 20°C(68°F)DB, Outdoor : 7°C(45°F)DB/6°C(43°F)WB
PFFY-P VLEM-E
Notes:
*1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. *3 Measured point : 1m x 1m, Power supply : AC240V/50Hz
Cooling Indoor : 27°C(81°F)DB/19°C(66°F)WB,Outdoor 35°C(95°F)DB · 1dB(A) lower at AC230V/50Hz
Heating Indoor : 20°C(68°F)DB, Outdoor 7°C(45°F)DB/6°C(43°F)WB · 2dB(A) lower at AC220V/50Hz
· 3dB(A) lower at 1.5m x 1.5m point
*2 Air flow rate/Sound pressure level are in (Low-High)
*4 It is measured in anechoic room
Notes: .
*1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.
Cooling Indoor : 27°C(81°F)DB/19°C(66°F)WB,Outdoor 35°C(95°F)DB
Heating Indoor : 20°C(68°F)DB, Outdoor 7°C(45°F)DB/6°C(43°F)WB
PFFY-P VLRM-E
Notes:
*1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. *3 Measured point : 1m x 1m, Power supply : AC240V/50Hz
Cooling Indoor : 27°C(81°F)DB/19°C(66°F)WB, Outdoor 35°C(95°F)DB 1dB(A) lower at AC230V/50Hz
Heating Indoor : 20°C(68°F)DB, Outdoor 7°C(45°F)DB/6°C(43°F)WB 2dB(A) lower at AC220V/50Hz
3dB(A) lower at 1.5m x 1.5m point
*2 Air flow rate/Sound pressure level are in (Low-High)
*4 It is measured in anechoic room.
Notes:
1. Cooling/Heating capacity indicates the maximum value at operation under the following conditions.
94
PFAV Series
FRESH AIR INTAKE Model
PFAV-P VM-E-F
Notes:
1. Cooling/Heating capacity indicates the maximum value at operation under the following conditions.
Indoor Outdoor Pipe length Level difference
33°CDB/28°CWB 33°CDB/28°CWB
Cooling 7.5m (24-9/16ft.) 0m (0ft.)
(91°FDB/82°FWB) (91°FDB/82°FWB)
7°CDB/3°CWB 7°CDB/3°CWB
Heating 7.5m (24-9/16ft.) 0m (0ft.)
(45°FDB/37°FWB) (45°FDB/37°FWB)
Please recycle.
96