Pont No, qe Req;A B qu d Vu ∅Vc Check

(ksf) (ft2) (ft) (ksf) (in) (k) (k)


1. 3.288 5.16 2.27 4.66 1.75 5.18 5.44 OK
2. 3.288 2.86 1.7 4.58 0.84 2.18 2.31 OK
3. 3.288 12.89 4 3.84 4.43 17.4 19.8 OK
4. 3.288 18.17 4.3 4.76 5.83 23.83 28 OK
5. 3.288 16.65 4.1 4.8 5.43 21.6 24.9 OK
6. 3.288 20.39 4.5 4.88 6.38 26.8 32.1 OK
7. 3.288 13.43 3.7 4.68 4.49 16.9 18.6 OK
8. 3.288 16.58 4.1 4.72 5.37 21.3 24.6 OK
10. 3.288 23.2 4.8 4.89 36 7.06 30.8 37.9 OK
12. 3.288 29.9 5.5 4.8 8.56 40.6 52.6 OK
13. 3.288 20 4.5 4.7 6.22 26.1 31.3 OK
14. 3.288 19.3 4.4 4.57 5.88 24.3 28.9 OK
15. 3.288 32.4 5.7 4.75 8.96 43.4 57.1 OK
16. 3.288 31.2 5.6 4.78 8.77 42 54.9 OK
17. 3.288 19.9 4.5 4.66 6.18 25.9 31.1 OK
18. 3.288 15.11 4 4.48 4.96 19.5 22.2 OK
19. 3.288 26.9 5.2 4.69 7.75 35.5 45 OK
20. 3.288 25.2 5 4.81 7.43 33.2 41.5 OK
21. 3.288 16.7 4.1 4.75 5.39 21.4 24.7 OK
23. 3.288 6.09 2.5 4.68 2.16 6.7 6.73 OK
24. 3.288 5.87 2.4 4.88 2.05 6.2 6.49 OK
Table 4.2. Design of Isolated Footing for the two and a half Storeyed Building