You are on page 1of 19
AREVA SEGIA.P.TRANSCO/CRR: DATE :5.09.2011, ‘The Chief Engineer, CONSTRCUTION, A.P.TRANSCO, \VIDYUTSOUDHA, HYDERABAD Sir. SUB ; susmission of standard drawings for 132 KY &220KV CVTS -REG We herewith submitting two sets of standard dravings for 132 kv and 220 KY capacitor veltage transformers for standardizing the drawngs whic required for various projects, We request you to kindly approve the same 5 Thanking you, 4 Yours faithfully, For AREVA T & DINDIA LIMITED, CR HeiowcRy- IC. RAMA MOHANA RAO) ku Mag VAIDYANATHAN upkno O27 4oF 23903 ene On ee AREVAT&D. AREVAT &.D nets United, 5-4-187/1st Floor MG. Road, KarbalaMicun, Secunderabad -500 003 Fel 291 402794 8820/21 Fax. + 81 402784 9003 wewareve.cern REGISTERED OFFICE | E- 48/7, OXMLAINDUSTIUALS AREA, PrASE I NEW DELHI 110020 a aX BREVA CUSTOMER : APTRANSCO P.O. No. : AS APPLICABLE PROJECT : AS APPLICABLE PRODUCT : 132 kV/4400 pF CAPACITOR VOLTAGE TRANSFORMER (CCV-145) STANDARD | REV. SL.No, | DRAWING DESCRIPTION No. No. : ‘STANDARD GUARANTEED TECHNICAL PARTIGULARS FOR OF] PADS | 00 | 430 KViA400 pF 3.V.T (CCV-145) 02 | 7128-1008 | 00 | STANDARD DRAWING FOR 132 kW/4400 pF C.V.1 (CCV-145) ‘OUTLINE DIAGFAM os | 7196-11177 | 00 | STANDARD DRAWING FOR 132 KV/4400 pF G.V.T (CGV-145) NAVE PLATE 04 | 714-8988 | 00 | STANDARD DRAWING FOR 132 kV/4400 pF C.Y.T (GOV-145) SECTIONAL VIEW 05 | 7158-274 | 00 | STANDARD DRAWING FOR 132 kV/4400 pF ©.N.T (GCV-145) YCnMINAL CLAWP i STANDARD DRAWING FOR 132 &¥/4400 pF C.V.T (CCV-148}, 06 | TIeB1063 | 00 | SECONDARY TERMINAL BOX o7 | 728.556 | 00 | STANDARD DRAWING FOR 122 kV/4400 pF C.V.T (CCV-445) PORCELAIN HOJSING 08 | 7138-227 | 00 | STANDARD DRAWING FOR 132 kV/4400 pF C.\.T (CCV-145) SPECIAL NAME 2LATE FEV No DESCRIPTION CHAD ‘APPD DATE TITLE LIST OF STANDARD DOCUMENTS FOR 132 kV/4400 pF CAPACITOR VOLTAGE TRANSFORMER (CREEPAGE : 25mm. | kV) CHKD : K.Ammasai 05.09.20; 11 DOC. No. *00-A-403 REY. 00 05.09.2011 APPD : V.S.Nagendra AREVA ‘SYANOAR GUARANTEE TESTRVGAL PIRTIGULAT FOR 182 400 pF CAPACITOR /OLTAGE TRANSFORMER (CCV-145) ‘TD, DC. Ne 7004-404 3 Tits a 1 finiscurssanoandasons Aneva TaD oA ITED teu Tarte Dons B | houndeanersppe nan cov us v alone sto /o cae 088 Ig ec r/saeto se aT rr ¥ rinse lace vy np ris Pro hrs ssonaes Tee i R it ese te a ls nd pt ash cent sig ws = = ey fran eon w 78M es pi era en vA m0 Lares ystam vonage w vs id 7] IE Bg | fase morocco stn 1 2c 18 nso sere SS) SIE SE) | sfecreoceerstene serie iain — a a z Fl ese 14}eipsctonce se BB) BE | sloneimomounne " 00 10854 Ie) S) BAY | sharon etna wie >s00 Bn 8 s FO | fsaknra nen ing woe a srg 3) S| BBL | cleoumm ie seal beds alg) 3 g 18[0,e min pawer frequency test wage Eay e| 2) sg] | “Besos shine 2 ae BL] S| SS) | sebsnmme poor musi wats ks Bl 2) & 3| [sa Ferica Mime 4 Rs 3 EL, (8.5) | srloenmu cere reamnane nance oad Sipol FE) | pronmana we sens zs é3 a Zl fx) BRL | 22ft 280 merase: mpuice witstenctest vatage Se Z| B 5 | | “leroaor Wi ssa Ig 8.3 “|! BBY | exfemosoomsose nteniy su Bay Ble) ge fwiisierevotage of caput (ry 8 wet) i Netepptoante 3 ¢ =) 2) 2B) | 2xlocona stron otiae ems 92 g| @ Be | lactmeononces ann stil 3 2) 22 [em se Re eo] Bo) | apredsesnison 3 340 a ed BB] | sets ‘9 “ ig aE aafeene cv we ame Yes byucng ean | F | | eloaatgan wanperecesiaot ested [es : - rs Sos ones e stlompsse since ia ss Re s1fgesed eros Pas ako oer > a 5 oko amnasat Aveo. gana VsNagendre APPROVED FIR TURAKEY PROJECTS AWale y Ccuier ENGINEER CONSTRUCTION-1 APTRANSCOMIOYUTA SQUOHA/HYO, aa F TaRISINIS Labaans OLD Ee ssorsaceiz| ra Aaisucyrimat justin) MATEY ‘SMANIOM SO 53108 bee bon! fa? our) opp is eis | poorer sonar ope on vay OY ile Eis =" wreova rune ae pai] Oa ais Ft i (sri-no0) EAD woorr /nee VHONOS HINAGIA/OOSNYWLe!Y 3/2 be zy 404 SONIMYEG OVONVIS aay INOS ( HAINIONA J3IHO S le HSE ies [Ran sce set Se eres Ty Wel ayes, Be | + FH S19300d AINUNL VOI OFADHdEY # |e é fs LI {08 ONTLEYS, Ss X= Wisa 3 3 z (8s @ ~ uISoddo kTIvNOOvIa) E | Coas sssmvivis) é 08x4 8Ein “SON Z i. z no ousums (c20-% NABQOW/93/VTUB_VALIOW/7BHE/ISM + NIVTBOWOd 40 SAV “£0 “GALVOON! JON St SONYEIOL 3EIHN STEVOT dC 38 TW Z017'SI 9 SY JONVETIOL WERNEO 80 UASIWATS 310 LOH 38 TIVES >AvwL ~sSMOTION SY DINYL LINN OUNOWN OMLOTTD HSIN SO SEVAXOUdEY RIV CELYOIONI SLHEIBM 70 ‘64 OPE | 110 30 HOB £0 ‘962-931) NK S04 “264 OF INA BOLDED BOM =6% FL = ALNYND WO ZO ws 9232 — 3ONVISIO 3OVEBRO TWLOL 10 LON “io qwaaNm (se: [SONS WHABET SMT IO SVG a wa Ea Gia) HSE TH oS IVE AVY (OH Oe) Sus Swish OER AST 38 lafelsisi Cony TB IT POE WME A oN0935| ewis| (avis) me ONT : = g Transformer(cer 2011 Prepared & Approved during October “T Standardised Drawing for 132 KW/4400 pF Current Voltage Transformer (cev- Title: Standard Drawings for 132 KV/4400 148) out line diagram, Sel Ble heh, 3 Ske I & RILAPY, ew TAREVA 100 Indi Lite, This must be rained 5 g Nf ecrreonia in Since su win Tess | Ee 8 ony ether purpose nor may'N be_copled or tent wthout our written p ze Q 768 | 65 o| OOSNVULLAY | Jou iouosng, 2 7 a gi 2\5[ | alae Ft jee Sees g a 3| z 3 i 4 Nos. #6 HOLES L F 4 E} Ba hope CAPACITOR VOLTAGE TRANSFORMER = Bla é See Slo|e| Ele ez 258 3 ole S| g258 ea 4 > a2 | | | wl ps) Zag e325 s| |g] 9/838 gs Fz C2 = c S| |e) S28 BSoe a| | 3\z5 2889 S| 8) glae aBed | 3] |e) glee ggEe . S| [e/B/e2] Bakke | 2| |e) zig8 SE ' Bg! jo] S25 RAE 8} | £i pl>S Biz a) gee el g 25 1 S| |S'WP/ESi og Ed et Liesl 8 fs | 8) (2B) = a aa al TRIS) O a a3 2 a 3) 3 BB - 5 #) 8] * 8s = : g| eli 3 ||: Corrier blocking device WEIGHT 3 ¢ 3 L: Reactor 40 k § Z| 3 £ = Vologe limiter device 3 9g al § 5 ranstormer Primor e i] 8 g 5: Transformer Secondary YEAR | g BD! Damping device N.: tow Nellage terminal of the eM @ | HF : Low voltage terminal of the 2 (8 l a2 5 1: “Ground terminal SL.No. > = (3/8/2 Fi: Fuse a Ss | ai ie Sondarde TEG60044-5/60356 go l2| liz Type Seay SHEL IR) me || Teeshcltaraen tenes | Feo s>(e> ie] 24 5B | | Roted voltage 2 132Ky) ZB E28) = Highest aystem voltoge 158 $8 (8) [4] 29 Insuletion evel 275KV/650%Vp ‘| gs &3 Rated. frequency 150 He 25/2 |e] 82 Nominal intermediate veltoge : 2 A/S 28) Sole) 23 cow || tetas rect ToedNt, 1.5-30Sec . Balk) SSUES || He Capacitance | 8400" pF Fz) 2/8) SFR) A || Primary copocitonce cr: Sarr 182] ESE] SS CYB || Scondery Gopccllonce co: 2at92 BF | G5 Bes 3] Be BE | [Connection Ratio ced BS ass] Fuse a 3g leo8 i gas 2 Jaxin [1320004787110 /73V | 50 VA Cl 0.2 | 1A eg" |S 318) 2 ce B | [oman [rs2000(7io/v 50 va cos ioA| | | | ee i TSR st sh ‘CAUTION : WF TERNAL UST BE EARTHED F NOT USED FOR CARRIER H 5 5 a) P4 "pane WTRMRAL SHULD ALWAYS BE EANTHED & | © |p z : . al 8|alalé APTRANSCO’ sla OPE 5 ° ® & 7 aX AREVA T&D Indio Limited ele fh] la ABEVA Instrument Tronstermere Ohiion-Ingio | = T3-B-117/00 | + = [4 z i" z A z DESCRIPTION : Fav TERNAL Pa HV TERMINAL PLATE SHLD BELLOW BOTTOM FLAT FOR BEL (CASKET FOR PGRCELAN TO FRE [END FLANGE, PORCELAN INSULATOR +] [GAPACTOR STACK ASSENBLY [EOTTOW PLATE FOR STACK ASST ignelure_ Date This must be rotumed [5 Tener Nowe cour written permiesn, OL FILING PLUG (ENED) [GASKET FOR Sec, TERMINAL BOT EARTH BLT foANeING CCU fou oR PLUG ittbe cooled 0 lent trout Bonnecten with out enauey/ AREVA TD India United, APPROVED FOR TUANKEY PAQJECTS “hs lete 1 CHIEF ENGINEER / CONSTRUCTION-1 i APTRANSCO/VIDYUTH SQUOHA/HYO. o ou oRAN PLUS (2) Voltage a eS BS a Transformer(ccy-145) (AREVA make), RN [arma [osoese] STANDARD DRAWINGS FOR STDIGTP-DWGiApproval No, 212-2-sheet3 Revision No.0 /appokoemalan] ’ ‘srotowal vow | 2% AREVA TaD incia Limited | AREA nstument tronstormers Divson-tdio Ci HF le: Standard Drawings for 132 KV/4400 pF Current Voltage Transformer (cev- | 145) sectional view: = z i NOTES: — 01. REFERENCE 1.$:$561—1970 (02. FOR GENERAL TOLERANCE REFER COARSE 1.$:2102 (Port—1) 1983, 03. MAKE OF TERMINAL CLAMP : MEGHA ENGG. / VENSUN ENGG. 04. TERMINAL CLAMP SHALL BE SUITASLE FOR BOTH HORIZONTAL AND | VERTICAL TAKE-OFF. H 931.77 (Moose) [om waz icanerist 05 [Hex NUT z mi Ere LI 28.62 (ZEBRA) @¢_[ SPaING WASER [4] FOR MID BOLT | ws atte oor Os [ALAT WASHER [FOR WIZ BOLT | ws nor oe 3 a2 HEKBOLT = wiaxio0 J OT _| CLARE PIECE 2 | 95195195 ST Tene | _oescRPTON | OTH] STOak SPECT REARS Eg3| Sal nS 253 siz 288 23 ‘APPROVED FOR TURNKEY PROJECTS 4 zi 928.62 (ZEBRA) 931.77 (Moose) Am 3 “\%9 0%, iu SECTION-"AA” Corer ENGINEER CONSTRUGTION-4 ss3| APTRANSCO/VIDYUTH SOUDHA/HYS, Standardised Drawing for 132 KV/4400 pF Current Voltage Wa [RE [ncaa Woe wai OR aE ‘Transformer(cev-145) (AREVA make). [DRN. earmens [eson| STANDARD ORAWINGS FOR REF. GTP. - i co 1324 /4400pF C.¥.T (Cov=148) SN STD/GTP-DWG/Approval No. 212-2-sheet4 Revision No. 0 et arene © <4 sereenve2] | Prepared & Approved during October — 2011 De MV Teo waa mites Bes ustomer ref: APTRANSCO FAREVA Instrument Tronstormers Division-india Faro} : Standard Drawings for 132 KV/4400 pF Current Voltage Transformer (ccv- 5) terminal clamp [ tl ray ibe copied or lent without Connection wit our ened AREVA TAD Indio Lied, LEAD FROM Fuse—— 20 | 29 [set] Sat] 302] 502 rilra|er}ez| er | eo 2a | 20 | Sai] Sar] S02) 502 NOTES: — 1. FL & F2 = 10 Amps FUSE 2, HE ~ LOW VOLTAGE TERMINAL OF THE co 3. N = LOW VOLTAGE TERMINAL OF THE EMU 4. E ~ VOLTAGE UMITER DEVICE 5. CONFORM TO [P—55 AS PER IS~13947—(PART-I)-1993, Sine] DESCRIPTION Take ASSEN 1 OMNECTOR ASSEUELY Tost ‘ROME STR CABLE GLAND PLATE LEAD FROM MULTIUSHING pp LEAD ROM MULMBUSHING ——- CIMT ENCLOSURE PROTECTION CLASS OF SECONDARY TERMINAL BOX APPROVED FOR TURNKEY PROJECTS ADar\o p01 CHIEF ENGINEER | CONSTRUCTION-1 APTRANSCO/VIDYUTH SOUOHA/HYD, 6. 4 Nos. 3/4 Inch CABLE GLAND (UNDER SCOPE OF AREVA SUPPLY) Standardised Drawing for 132 KV/4400 pF Current Voltage a a aun Mmm. URES OMERWSE SOREN. | SCALE : NTS. 2 poses ore ARO ORAWINGS FOR [Aer Transformer(cey-145) ( metmake)d | CHD. V32KV/4400pF C.V.T (CCV~145) STD/GTP-DWG/Approval No. 212:2:sheetS Revision No.0 | [arroanawafonan] ' setowoatr terumat pox | > -Ea-p [2ercamsco] [Prepared & Approved during October—2011 BX EVA THD tosio. Limites Piece 1063 CEC IC aE AREVA hstrument Transformers Dision-Indio ROTO 10 Title: Standard Drawings for 132 KV/4400 pF Current Voltage Transformer (cev- 145) secondary terminal bo = I See eeeeeeeoe Cc I — i z z venns oF ] ee = SHED PARAMETERS AS PER EC:BIS-1086 | “Greene PoRcELAWW | REQUIREMENT | i TOBTANCE BEWEEN SHED=€ [ Be7e am | > 30 mh 1 | ano serine SAGNC wD SET} EeeEEEE Ee great) | ‘OveRHANG (S/°1) El ereeee eter > Bg “SRATIO BETWEEN CREEPAGE STANCE a ay ae AND CLEARANCE Iai /at - 4 Bd “ERAT GETWEEN CREEPAGE O'STANGE Pry a7 3) [ND CLEARANCE 162/22 = See BONFFERENGE BETWEEN Two CONSECUTIVE 5 25 |e 214 SHED. OVERHANGS PIP? _| iad ([Gonezrase rector ae p<] ee} [TiPRorie FacToR 109, > oF 233 a + FOR POLLUTION LEVEL I (25mm /AV) AS PER IEC~615 HEAVY DETAILS OF SHED PROFILE iW i FOR INFORMATION ONLY TES ae 1. TOTAL CREEPAGE OISTANCE : 3625 mm (Hin) 3a] | 2, APPUCABLE STANOARO LS : $621 / IEO-62155 / IEO-a18 Ssal ‘3g 3. WAKE OF PORCELAN : WS/BHEL /ADITYA eARLA zc /MODERN rigez, 2 4, GENERAL TOLERANCE : £(0.04441.5)mm. WHEN “4” IS < 300 men. H e8) EPOXY JONT “H0.0736+5)mIm. WHEN “et IS 3300mm. VERE "3" 15 THE igs DENSON 1M enn. a8 5. ONE PRY JOT (aximum) A esi Standardised Drawing for 132 KV/4400 pF Current Voltage Transformer(cev-145) (AREVA make). of STD/GTP-DWGiApproval No. 212-2-sheet6 Revision No.0 i 34 ———~ i ul E Prepared & Approved during October — 201 : | a Customer ref : APTRANSCO af i B34 Standard Drawings for 132 KV/4400 pF Current Voltage Transformer (cev- 238) |145) porcelain housing | 28 7% NAME [GATE | Ai mine Wo ORS CRORE EME SoTL fii fg] erven Fon tumee Paez i pelea eae oe 273/35 fox. 1S2KV/4400pF CV.T (CCV=145) © = 2oe| 215 HY \yeabeon [APPO. fs nose] os 0071 PORCELAIN HOUSING =} . 232) 2|21 CHIEF ENGINEER ACt Indie. Limite DRG. Ne. Ht APTRANSCO/VIOYUTH SOUDHA/HYO. Bo AREA Te In Les gg [zeseB=55e fe: ik AREVA Instrument Teonsformers OWision-Iadio Joe = L z 7 | 1 fiat x Standardisec Drawing for 132 KV/4400 pF Current Voltage ii alg 2 | Transformar(cev-145) (AREVA make). is z “BR 4 STDIGIP-DWG/Approval No, 212-2-sheet7 Revision No.0 J |g|B | Geteewsce] | Prepared & approved during October —2011 S| 5 | stomerref : APTRANSCO 3s [El Te pene Drinus for 132KV/4400 pF Current Voltage Transformer (cov) ia | ei: Mobis | 5 8 BL) 1, MATERIAL OF NAME PLATE ~ STAINLESS STEEL (0.5 mm. THICK) a2 FOR OUTDOOR PROOF 2; Joe 2. FOR GENERAL TOLERANCE REFER COARSE 1.5 2102 ; | ~2 pe 128 ct 3 ae 4 7 Esy ae, CUSTOMER. : AFTRANSCO S23] 8 ro) P.O. No, : AS APPLICABLE o gée g PROJECT —: AS APPLICABLE ; | TEA BITOT za 2 Nos. 95 DRILLED HO.ES arpraven £08 TURNNey PROJECTS ea awww’ P bE ION-1 ees) ingen | CONSTRUCTI poe Caney ISSO NIOYU rst SOUOHA/HYO- | S28 T wane [OaTe | al owcioms i Winn MESS OMERNSE SEGRE. | SCALE? _ NTS. 2.2 ¥ ORW. [eammosa [ooosam STANDARD ORAVING FOR REF. | 2 9 CHO. 152k¥/44009F C.V.T (CCV-145) & 2 9 APD. |vsnegenae| os 00-1 SPECIA. NAME PLATE i f+ i , RG. No. f $38 AREVA T&D Indio Limited igh” 252] AREVA Instrument Transformers Division-Indio Frey ne 00 | AX AREVA CUSTOMER APTRANSCO P.O. No. : AS APPLICABLE PROJECT : AS APPLICABLE PRODUCT + 220 kV/4400 pF CAFACITOR VOLTAGE TRANSFORMER (CCV-245) STANDARD | FEY. SL.No. | DRAWING DESCRIPTION No. No. | saewae oo _| STANDARD GU/RANTEED TECHNICAL PARTICULARS FOR, 220 KVi4400 pF ¢.V.T (CCV-245} 02 | 7128-1007 | 00 | STANDARD DRAWING FOR 220 kV/4400 pF ©.V.T (CCV-245) OUTLINE DIAGRAM 03. | 713.8-1118 | 00 | STANDARD DRAWING FOR 220 kV/4400 pF C.V.T (CCV.245) NAME PLATE 04 | 7148-989 | 00 | STANDARD DRAWING FOR 220 kV/4400 pF C.V.T (GOV-245) SECTIONAL VIEV os | 7158-275 00 | STANDARD DRAWING FOR 220 k¥/4400 pF C.V.T (GCV-245) ‘YERMINAL CLANP STANDARD DRAWING FOR 220 kV/4400 pF C.V.T (COV.245) 6 | 68-1064 | 00 | SECONDARY TERMINAL BOX ov | 728-B-857 00 | STANDARD DRAWING FOR 220 kV/4400 pF C.V.T (GCV-245} PORCELAIN HOUSING 08 | 719-228 | 00 | STANDARD DRAWING FOR 220 kV/4400 pF C.V.T (CCV.245) SPECIAL NAME PLATE REV No DESCRIPTION CHD ‘APPD DATE TITLE : LIST OF STANDARD DOCUMENTS FOR 220 kV/4400 pF CAPACITOR VOLTAGE TRANSFORMER (CREEPAGE ; 25mm. / kV) CHKD : K.Ammasai 08.09.2011 APPD : V.S.Nagendra 05.09.2011 ae a AREVA, ~ (GUARANTEED TECHNICAL PARTICULARS FOR 4 20 WV/A§00 5 CAPACFOR YOLTAGE TRANSFORKIER 2 M S006, No, 700-4406 Tie : sfesrutserer nae a across AREVATEO NOINLASTED 2. numer Tarts ON ha 45 2} aoc ype cession coves 2 alee cpieie te orto e> ott accose y 4} pte pinay taper w 20393 2 sag nag wag slped sont wotme v FruSteer nosis beets § afrebert ears Thee Se ‘Trane rope te 2 4s 1 acd opt each ont ng vn = ss 9am sinstaneus buen my ag ha 2 tof tera buon va 150 ge + riers eyiem vonage ww 288 ze velo eae arn epg ed ie 12 connous 1.5 Un 90 see Gyr Ler eaecieseaeriniy =e LF ig zg % a hain gg oe ce ie Pl} vhructecer 3 2 belt 19 ion ine owe kequency tes! voltage: = € acta wins 2 BAe 20]One sninuie power roquency tot veltage me ee Base samen faye od so 0 aS chs ana icp vitae ns e re vs 108 baz ss)esonso eco seating save cee Sy we svete as= = 24lconna oxncon age on a8 dnt 25s. rate ican ota Bs Sa Jsrestaur owns gmeev) e800 3 46 13 | ashraatwain eres) * 49 & = arfoseny aero ” e aes ashimnenercvts ae remnaicalysoaee ‘es by ong easels rae i eaFumin erangonen at esteg ey sfeatacatengenatnur! verte FESS cfs slew eee 2: trnseo Foros tds ga > sed Foro Ps ‘APPROVED FOR TURRICY PROJ ota galrane a ene N VAIS wae CHIEF ENGINEER ) CORSTRUCTION-1} ‘APRD : me APTRANSCO/MIOYUTH SOUDHAHYD, gy “nae a RVI ‘Standardised Guaranteed Technical Farticulars for 221 14400 pF Capacitor VoltageTransformer(cev-245)( AREVA makey | FAS. STD/GTP-DWG/Approval No. 2123 Revision No. 0 | ERMECe) [Prepared & Approved during Octoter-2011 | loose Dipul-voisinig Srewojsuo21 quauinnsyy WASEY, as , eh rewun opu cer varw = XJ x Nougni S02 waawiona aa f= 6 wviovia aNTuno rsoespasiac Gams Ot RCMP : (ere-n92) 490 stoort /n0ce a0 Ba 203 SONG aUvOWIS —_[ireoca[ eu] “sgoarOud AANNUNL Od OUADHdEY SunLOMALS LAOSAIS OL LAD _ ‘303 S10" Deo SON y OSHS NOTLABeIa SIN Sivos | aoe aio son ww ay sso nr | aLval SAFN ‘W08 ONES X= WW1s0 o* ____| ow (ss 2 ~ ausoado ATIvKODvIO) | (aais ssmnavis) LOS YGH OKTIN "SON Z NAECOR/O3/ Tela VALIGW/"BHE/iSm © NIVIEDWOd JO BVH “LO ‘CRLYOION! LON $1 JONVESIOL SASH evOMadY 38 TIM ZO1Z'SI 292 Sy SONVACTIOL WENO 90 5 OSSINVATYD ID LOK 38 TVHS vl ~SMOTION S¥ DHL LINN OUIND¥N OMOTH HSN 50 ! ALVANOMeaY SY CALYOION! Su wae aw) t 50 O1¥ § LAO 30 LOM £0 md ONT 3 H “Wo aweanin (Ses—Si/96z-9aI) Na BOs “35% OF WO SUTINAS (Z08=95)) INN UaLtovEVD wos “SOY Zz, ocee. =P auNyne “10 20 | sin 219 ~ sowwisia Jovusse9 WO! 10 | =TS3I0N \ SONS WNVEEL SHIT JO SIVIIO poz. wH Beef Standardised Drawing for 220 KV/4100 pF Current Voltage Transformer(cev-245) (AREVA nake). STDIGTP-DWG/Approval No. 212-4-sheeti Revision No.0 i ram, Teea.ve | Wowawosi0 [NS L z Prepared & Approved during October — 2011 Customer ref: APTRANSCO _ Title: Standard Drawings for 220 KW/4400 pF Current Voltage Transformer (cev- 245) out line FaiuOIsND ny other purpose ner AREA TD Ingle Limited This must be return onnecton with cur snauiey/ Tender he = may Te be copied oF fot without aur waten permission Seid omen Fz 4 Nos, 95 HOLES. z OOSNVULAV T10z — 49q0309 Suunp porouddy 79 paredaig “(eM VATU) (SpZ-A99)s9MOJsUEI, 40084 YoodLNO wos S. CAPACITOR ‘VOLTAGE TRANSFORMER ct 02 Sal So] oe Z01Z'S| 3SUYOO YINIY IONVETIOL TANI UNOS “= 4 2 8 g a a é 5 a (OIMLUAY S'0) TERS SSFINWIS - ALVId SAN 3O TWRFaLV) O'ON UOISIASY THOUFFTIC “ON [eAarddy/OA\C-dLO/CLS. -Ad9) JULLO;sUAY aBLVJOA UDLIND AE YOPH/AM 02C 40} SBULMCIG PrepUEIS -9N1, £_98eHOA IWO.IND Ad OOPP/AM OCT 10 SurMeIG posiprepurg, iS FOR FOF FO Fe () (ESRECREREEEE | | solv eo fe be hed [an] | 6 3 OPE oO 1 Carrier blocking device WEIGHT | Reactor Voltage limiter device 410 kg Transformer Primary : Transformer Secondory YEAR : Low voltage terminal of the EMU eat on IF : Low voltage terminal of the CC!) No, c E 5 s 5 : Domping device N HI T F : Ground terminal W 33|2| Fuse & } ‘Stondords 1EC-60044-5/60358 i Sipe Bcc al |i TEE burden simultaneous | 60 va if Thermal urden Ma Rated voltage 2204, a] |e fighest system voltage 28h 212 Insulation evel + 460ky /asaKvp Rated frequency Sey INOS HiNaatn/oosi NEL INBISNOD / 4833NIDNG 3319 ANG 104 al POW! O1pU) GL AREY Nominol intermediote voltoge : 21KVA/S Voltage factor {.2cont, 1.5-30Sec HF Capocitonce 4400" oF Primary Gopocitance Cl: 4881 BF Secondory Capacitonce C2: 47186 pF |connection] Ratio lAccu*8}? Glass Fuse Yo-in [220000 4/3/1104 /8V | 50 VA Cl 0.2 SU3afUd BRET Yo anouddy auvid aN (s¥2-A09) 4'A°9 80047 /AMoze “CAR eH; i Nos SONIMVYG GvaNVIS "Eas BAU Ser ws w By se@GMO-TH | Suva] BNYN DipuF-UoIshIG siewi0jsu0., juounney VASE Ey "on “Ou “za] Sin Sos oo jetis—a—erz| 2e-2n _[2200004/3/1104/V | $0 VA Ci 0.5 [S01~302—3n|2200004/3/10-T10A/5V| 50 VA Cl SP {AUTON H TERMINAL UST BE EARTICO IF NOT USED FoR enna TRANSMISSON. WN TERMINAL SHOULD ALWAYS BC EARTHED, "APTRANSCO" Bx 000 180 10 Umiea AREVA Iniurent Tonsormere Ovsan-indl 713-8-1818/00 — z Signatur This moat be retrned our wrthes permiawon, | ete Tender Nom Connection with our enery/ Ikbe copied ar Tent whnout BREVA TAD Indio Linites 08 confident in ‘ny other purpose nor lety of OW FILING PLUG (SEALED) i ® lL pra PLus @ __DESCRIPTION eeuLow Sorrow FLATE FOR BELGW (Gasket FOR PORCELAN TO FORTE ENO FLANGE [CAPACITOR STACK ASSET S0rTOM LATE £08 SIAGC ASSY LW. BUSHING pualseORER_ ASSENSLT [16 [eAsKeT FoR THK REACTOR ASSOUSLY. ot TAR GOWER PLATE TSccoNOARY TERNAL BOX (CASKET FOR SEC TERNAL BO EARTH BOLT 20_[DWWPNG CROUT Zion, Dean PLUG Pa Standardised Drawing for 220 KV/4400 pF Current Voltage Transformer(ecv-245) (AREVA make). se Provecrs CHIEF ENGINEER APTRANSCOMDYUT ea eC TONGN YUTH SOUDH AHO, (HL GOS AW wm. NESS ORE SER [ SCALE) NTS || STD/GTP-DWG/Approval No. 212-4-sheet3 Revision No. 0 ‘STANDARD DRAWINGS FOR [REF zat /Asooph ET (COV-248) SECTIONAL VIEW i Prepared & Approved during October — 2011 AREYA T&D India Limited eT antag 9 APTRANSCO TAREVA [nstrument Tronsformers Divsion-indie [1 “=E—8 tandard Drawings for 220 KV/4400 pF Current Voltage Transformer (ccv- duiypp pourmsa.y, (SrZ -a90) AoUMAOysUEAT aBEyfOA FUBLIND Ad OOFF/AN OZ 205 sBumwIC] prep at = oppUl—voIsiANg svewojsu0s, jwounnsy WARY ODSNVULAY 2 Jarrouvisny powun our aa vay XJ — . * on oe T10z—49q0390 Bussnp poroiddy 7 powdag | [asswveccr fs 6 ‘anvio TAINS rose prtoreal aga —— F | {Sr2-A90) L'A°9 ssoore/Mm0zz ‘oho DON UoIsIAoY FOOUSF-CIe ON TAoiddy/D MC-dLO/GLS, Ve Su] wos sonmmvua auvanwis —_[asoro] roma] Twa! 9 Sp7-A99)J9ULLOJSUEA, Saris ma mas oe es Se Grew Vay) Growyomoues,) 1 aBey10A. sH941n9 ad QOPP/AM 022 105 BuIMEIG posipmepuLIg, é | Fe ‘i VV 4-NOLLO3S 2 ere SpN¥ISIO 39¥9580 NSIALIG Olver | Big Hirer 197181 SONVEYEO OMY | ae = 7 Cl BONIS 30VEERD NEINLIE OWE ae Fe =p i: (1a/s) SNHIRENO z 2 2 GGHS any ONOVES NEMUIE Ove? | |" som Gore | waroe< [unt ents a SW0BHS N3ML99 JONVASIC sage DepSuNOGE | NWGOee dO : Sa | ats RRA | opst-cia-o31 way SY SuaLSHWeva OSHS l 7 reece ce oereeeeeee EET E i a H es a? > im aie fan at g-% | Standardised Drawing for 220 KV/4400 pF Current Vollage “ | Be sformer(cev- (AREVA make). iI | | a ER STD/GTP-DW3/Approval No. 212-4-sheet7 Revision No.0] i | | acreanaco| | Prepared & Approved during October ~2011 ig] | Customer tet: APTRANSCO — Zu Title: Standard Drawings for 220 KV/4400 pF Current Voltage Transformer (cev- | & 3 245) special name plate | Bis |T 51g | 3 a NOTES :- 7 31°) 1, MATERIAL OF NAME PLATE ~ STAINLESS STEEL (0.5 mm. THICK) ae FOR OUTDOOR PROOF 5S | 2. FoR GENERAL TOLERANCE REFEP COARSE LS 2102 a ‘ 4 uz = 1 eso {=3 g.4 CUSTOMER : APTRANSCO s2%{ 8) +10 Po. No. AS APPLICABLE ° | 1882 | . 2 PROJECT: AS APPLICABLE i FATT | 38 2. Nos. #5 DRILLED HOLES — APPROVED FO TUaWiE? PROJECTS Se . cuier encfieck 7 EONSTRUCTION-+ a APTRANSCO/VIDYUTH SOUDHayH¥D “NAME [DATE [Al DUENSONS ARE on. UNESS OTMERWSE SpeDneED. | SCALE > DRN. |K.Ammesoi |05.09.11 STANDARD DRAWING FOR REF. CHD. 220kV/4400pF C.V.T (CCV-245) <=4 ‘APD, [vSnagenrelosoa SPECIAL VANE PLATE DRG. Ne \ B% —AREVA THD India Lirvitea 713 A=228 AREVA Instrument Transformers Division~Indio Faeywe, 00 |

You might also like