You are on page 1of 2

FMSRV (DN20-50)

Forbes Marshall Safety Relief Valve

Description
The Forbes Marshall Safety Relief Valve FMSRV is a
high lift safety valve with gun metal seat, valve and brass
internals suitable for use on steam, air and water.
Size and Pipe Connections
DN 20, 25, 40 and 50
Screwed BSPT/BSP/NPT
Available with IBR certificate

Limiting Conditions

PMA maximum operating pressure 17.5 bar g


TMA maximum operating temperature 220°C
Cold hydraulic test pressure 35 bar g
Material

For following set pressure ranges 6 colour coded No. Part Material Standard
springs are available
1 Seat Gun metal BS1400
05 to 15 psi (0.344 to 1.03 bar g) White Seat ring Gun metal BS1400
2
15 to 35 psi (1.03 to 2.41 bar g) Yellow 3 Valve Gun metal BS1400
4 Spindle lock nut Brass IS 4170
35 to 75 psi (2.41 to 5.17 bar g) Green
5 Bonnet Cast Iron IS 210 Gr FG260
75 to 125 psi (5.17 to 8.62 bar g) Blue IS 4170
6 Spindle Brass
125 to 175 psi (8.62 to 12.06 bar g) Red 7 Spring Stainless steel 302 IS 4454

175 to 250 psi (12.06 to 17.24 bar g) Black 8 Bottom spring guide C 20 -
9 Top spring guide C 20 -
10 Adj. locking nut Brass IS 4170
Operating Range IS 4170
11 Adj. Bolt Brass
12 Cap C20 -
13 Lever Aluminium -
14 Lever fulcrum pin C20 -
15 Seat ring locking screw Brass
IS 4170
10 15 17.5 and nut (not shown)
The product must not be used in this region.

Dimensions: (approx. ) in mm

Size DN A B C Wt (kg)
20 48 60 145 1.4
25 60 65 160 2.1
40 73 84 205 4.5
50 80 108 250 6.5

Energy Conservation | Environment | Process Efficiency www.forbesmarshall.com


Capacity Chart Installation
The safety relief valve should always be fitted with the centre
STEAM line of the spring housing vertically above the valve. If the
4600
4400
4200
DN50 discharge pipe is not self-draining then a separate drain pipe
4000
3800 with continuous fall should be provided.
3600
3400
3200
The outlet from the safety relief valve should be arranged to
3000
2800
DN40
discharge to a safe place where it is visible but cannot cause
kg / hr

2600
2400
2200
damage or injury to persons.
2000
1800
1600
These valves are not suitable for mounting on boilers
1400
1200
DN25
1000
800
DN20
600 How to Order
400
200
0 Example: 1 No. Forbes Marshall Safety Relief Valve, FMSRV,
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
Set Pressure in bar g DN20 with BSPT ends and a set pressure of 6 bar g.

WATER Available Spares


80000
Valve head and spindle kit
DN50
70000
Spring kit
60000
Litres / hr

50000
How to Order Spares
40000
DN40 Always order spares by using the description given in the
30000 column headed available spares. For codes refer user
20000
DN25 manual.
DN20
10000

0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

Set Pressure bar g

AIR
1600
1550
1500
1450
DN50
1400
1350
1300
1250
1200
1150
1100
1050
dm3 / sec

1000
950
900 DN40
850
800
750
700
650
600
550
500 DN25
450
400
350
300 DN20
250
200
150
100
50
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

Set Pressure in bar g

Opp 106th Milestone B-85, Phase II, Chakan Indl Area A-34/35, MIDC H Block
Bombay Poona Road Sawardari, Chakan, Tal. Khed Pimpri, Pune - 411 018. INDIA.
Kasarwadi, Pune - 411 034. INDIA Dist. Pune - 410 501. INDIA Tel : 91(0)20-27442020, 39851199
Forbes Marshall Tel : 91(0)20-27145595, 39858555 Tel : 91(0)2135-393400 Fax : 91(0)20-27442040
Krohne Marshall Fax : 91(0)20-27147413 CIN No.: U28996PN1985PTC037806
Forbes Marshall Arca Email : seg@forbesmarshall.com, ccmidc@forbesmarshall.com www.forbesmarshall.com
Codel International © All rights reserved. Any reproduction or distribution in part or as a whole without written permission of Forbes Marshall Pvt Ltd, its associate companies
Forbes Solar or its subsidiaries (“FM Group”) is prohibited.

Forbes Vyncke Information, designs or specifications in this document are subject to change without notice. Responsibility for suitability, selection, installation, use,
operation or maintenance of the product(s) rests solely with the purchaser and/or user. The contents of this document are presented for informational
Forbes Marshall Steam Systems purposes only. FM Group disclaims liabilities or losses that may be incurred as a consequence of the use of this information.

DOC# FMSS/1117/TIS-FMSRV(20-50)/R2

You might also like