You are on page 1of 7
SZCOWIN® Te LOrTE O~ SZYL-SPS-800W (1.5KVA) Solar power system operating i structions See table below fonrecommended home appliances and the daily use time: system components: 1. Solar modules: 36v/200W"4PCS Glass lamination, with 10 meters Satelite | AC2sW 1 4 r00WH aa receiver 2. Battery: J2V/IOOAH*APCS SMF Lead- w acsow | 1 4 2o0wH | The total acid Storage Batteries load 3. _ Inverter: 24V/1S00W inside Power power ane Computer | actoow | 1oow1 | 4 come | should be 4. Controller: 24V/40A inside Power ako er eee Fan actaow | sow | 5 soot 5. Power Control Cabinet ze: ee ont light aceow | 208 | 8 1280WH directional wheels ence at Total 455 2580WH 7. Two Solarinterfoce Note: ‘The below appliances can be connected to the Do not connect any of the below appliances: power system: a 5 ) a TV Laptop Computer conditioners cooker SZYL-SPS-800W(L.SKVA) SOLAR POWER SYSTEM OPERATING INSTRUCTIONS I The main features TABLE OF CONTENTS L.SZYL-SPS-800W(1.SKVA) Solar power system, designed for remote users of household electricity, is an off-grid AC power supply system. 2.The system is complete with 4 solar PV panels and a power control box/cabinet. The power control box/cabinet, specifically developed and designed as an indoor unit and houses a solar charge controller, an TOPIC PAGE NUMBER inverter and 4 batteries. 3.The system uses microprocessors and special control algorithms to reach I. The main features ot intelligent control. 4Scientific charging and discharging protection. When there is Il System components reference drawing 1 over-discharge, the battery will have a compensation and maintenance voltage charging. When it is in normal use, the charging method is direct IIL Installation and use 3 charge and float charge combined. This is necessary to extend the battery life and to make charge control more accurate with high-precision IM. Technical Parameters 5 See aan 5.The configuration of the LED digital display device, allows the system to display battery real-time voltage, AC output voltage, easy for user to understand the system's real-time operating conditions. 6.The system comes with over-charged, over discharged, overload VI. Cautions 7 protection, unique electronic short circuit protection and anti-reverse protection (ff battery connect counter, fuse fusing, after the corrected connecting fuse can be used normally). These protections do not damage other parts. There is TVS protection against Thunder, hence the system is durable and reliable. 7.With the public power bypass function, when the battery power is low, the AC load can switch to the public power source. 0 System component reference drawing V, Packing list 6 | (1) Front of the Power control box Thanks for purchasing our home solar power system. To ensure safe use, 3 please read the instructions carefully before use. (2) Side of the Power control box LAC voltage meter 2.DC voltage moter 3.LED display light 4 System switch 5.AC switch 6.AC Socket 7.Cooling fan Solar charging port 9.AC bypass input st Installation and use 1. Open the rear door of the chassis, and install the fuse in the PE bag in the safety seat on the system’ s electrical board. (Remove the nuts on both ends of the fuse holder, insert the fuse on the two screw posts of the fuse seat, then the nut on the stud and tighten it with a wrench). Please refer to fig. 1. 2. Open the control box’s power switch (tum the switch button to the "on" Position), after 1-2 seconds, the DC header on the board will display the current voltage status of the battery. After it starts normally, the controller displays the current system power. (Note: When the controller voltage is under 20.8V, that means the system has entered the feed state, it should be recharged in time. After the system voltage recovery is up to 25.2V, then the power is ready to use). The system’ s normal operating voltage range is: 22-28. Connect the lead wire of the solar panel to the solar input interface "SOLAR PANELL" or “SOLAR PANEL2" on the side of the control box. When there is sunlight and the lead wire is connected correctly, the LED on the system board will have a charge display. 3. When confirming that the system is in full power, open the "AC switch* button on the chassis. and press "Il", once you can hear the "beep* sound, the system enters the self-test status to indicate that the system is tured on. (Note: Self-Test status-before the system has a stable output, please ccheck if the external environment and the system itself are normal or not. Ifall the system’ parameters are normal, it will be in normal working condition. During this period, it takes approximately 10 seconds, AC switch for the three-shift switch are, 0 for switch off, I for energy-saving mode, It for switching on AC power. Also, note that when system load is below 50W, the system will automatically enter into the energy-saving mode. Note: To avoid damaging the inverter, please note the following: (1) Avoid short-circuiting when using load, (2) The total load demand should be within the specified power rating of the inverter. Total power must be less than 1.2KW (P < 1200W) range. (3) First put on the main switch, before putting on the AC switch (4) See table below for the recommended home appliances and their daily use time: ‘Daily ri Appliance! | power | Quantity | working Remarks Equipment 7 consumption | | Pours Suieie | | theta] | aczsw 1 an 0WH | fd power ee | should be W AC SOW H aH 200WH [tess than Computer| AC 100W i att ixw | Fan | Ac io0w | owe SH Cigar [ac roow | 20wes StL TaROW Total__|_ACASSW 25801 The below appliances can be connected to the power system: Lamps Fans Ceiling fans TV Laptop Computer Do not connect any of the below appliances: t a —_ ug a xX Water heaters PUMPS refrigerators air conditioners cooker heating 2s Waterhanters, pumps sfrigeators ait 4. System shutdown, First, shut down the load on the system, and then turn off the AC switch on the side of the chassis for proper shutdown, (Note: When the system is powered on, it can be in normal use; however, when there is no load, you only need to put off the AC switch on the chassis. If the system is not used for a long time, then turn off the chassis’ total power switch. The time interval for turning on the power switch again should be a minimum of one minute, otherwise an error may occur. IV Technical Parameters Solar Panel Lon savers ‘Enhance charging 29.68 voltage BMAX |__ Float voltage Balanced charge vollage | 29 | | The conte lows | Finn ce | ‘current by solar ‘maximum solar charging 308 modules __| current | 6 Inverter power supply DC input rated veatt DCinpat raed curent | 82.58 voltage = Pa ae ‘DC undervoltage recovery roltage = Eee ee ca DC overvoltage recovery voltage | Rated Capacity om Onputrated power vor | iz Fett ‘Dynamic Response (Load * Rated oviptcurent "ete, | Onipatvated voltage | acer, tte ie os an fequency es vam, es | Waveform distortion rate | | pegs ee (THD) (Linear load) Tae 0% | Maximum system total current effcensy | | Neiee mete |

You might also like