03.04.2020, hlps:itke. mastercam.com/Prni50723.aspx Working from home with a network software license Problem Mastercam needs tobe used after moving ftom a physical office to a work from home environment Solution Ifthe Mastercam licenses are on a networkable sorftware license, the lient machine needs to have access to the network the server's broadcasting the license across. This can be achieved by the client system connecting to their work network via a Virtual Private Network (VPN) connection and the CodeMeter WebAdmin configured to point directly tothe IP address ofthe license server, Due to the VPN connection, the automatic search will nat find the lense, so each client must be configured to look forthe server's IP adaress. 4. To point a client directly to the network software license host, launch the CodeMeter Control Center from the Windows Start menu, CodeMeter folder. 2. In the lower right comer of the CodeMeter Control Center, click WebAdmin. The default web browser of the system will open to the following address: hitp:localhost:2235 © Codemeter Contiot Center -o x File Process. View Help Ueenee | Events No CodeMeter License information avaiable No Cicentairer found, CodeMeter service is running. Webadmin 3, Click the Cor uration tab on the top of the WebAdmin page. Select add new Server. hips mastercam.com/Print50723.a8p% we hips: mastercam.com/Print50723.aspx CodeMeter WebAdmin (03.04.2020 Pres ea } ye eaeRam™ Configuration v Pe ere Basic Configuration > Server Search List Server Search List| Proxy || WebAdmin | Backup Server Search List 1. Automatic server search (255.255.255.255) o @ add new server 4, Type the IP address of the server hosting the Mastercam software license. Oc Race 4B asic ceniguration |) Server Search tit Server Search List | Proxy | | WebAdmin | Backup Server Search List 1. Automatic server search (255.255.255.255) 9 Enter tha Server's name or 1D addrace: 5. Once the IP address of the server is entered, click Apply before exiting the WebAdmin page. Now, Mastercam will look for that IP address when trying to find an available license. Note 1: Nothing on the server needs to change to work remotely from it.I the Heense Is broadcasting across the Network, and \VPN clients are allowed access to port 22350 on the server, they willbe able fo check a Mastercam license out from the server. If this setup does not work, make sure there are no frewall settings treating remote connections differently than onsite ones. Note 2: If @ customer wants to Remote Desktop Protocol (RDP) into a computer sil inthe office, Mastercam wil run on this ‘system over a Remote session. This is because the host computer sill has direct access to the network that the network software license is broadcasting across. This is not an optimal situation, but twill work. Posted Today @ 12:19:43 AM by Jesse Quagliaroli https:/kb.mastercam.com/KnowledgebaseArticle50723.aspx tps mastercam.com/Print50723.25p%

You might also like