Mounting and Commissioning 33 commssonng [RL-PARALLE Setting parameter at address 5371 (secondary setting value) Rye Re Measured parallel resistance (secondary measured value) Prpur Popa Associated active power in p.u. for the measured parallel resistance Use DIGSI to set the parallel load resistance with parameter 5311 R1-PARALLEL and the calculated correction value with parameter 5313 CORR. R1-PAR... Activate the protection function with parameter 5301 1008 SEF-PROT. = ON, NOTE oie You can set parameter 5311 R1-PARALLEL to the resistance R, measured in the idle state, The following example provides orientation for the size of the correction value. The secondary values depend ‘on the system conditions. Therefore, they can deviate from the values in the example, The load resistance converted to the secondary side was 61 @ (parameter 5311 RI-PARALLEL). The following table shows the measured values: [Measured value R SEF [Measured value active power a) ae state R610 Maxiraum active power (or R= 59.10 lexample, 0.85 FIS,) OFS, BBS, 4 Rip-Riy 5910-619 AUPARALLEL 7, -P,,, "818 086-0 ~ 000664417 CORR. R-PAR. In the example, you would set parameter $313 CORR. RL~PAR. to the value -0.037 3.3.22 Creating Oscillographic Recordings for Test General [At the end of commissioning, closing tests may be carried out to assure the stability ofthe protection during the dynamic processes. A maximum of information on protection behaviour is supplied by fault recordings. Prerequisite ‘Along with the possibility of storing fault recordings via pickup of the protection function, the 7UME2 also has ‘the capability of capturing the same data when commands are given to the device via the service program DIGSI, the serial interface, or a binary input. For the later event, >7r'ig. wave. Cap. must be allocated to a binary input. Triggering of the recording then occurs, for example, via the binary input when the protected object is energised. ‘Such externally started test fault recordings (.., without a protection pickup) are handled by the device as rrormal fault recordings, i. for each measurement record a fault log is opened with its own number, for unequivocal allocation, However, these recordings are not displayed in the fault indication buffer, as they are not fault events. Triggering Oscillographic Recording To tigger test measurement recording with DIGSI, click on Test in the left part of the window. Double click the entry Test Wave Form in thelist of the window. 488 SIPROTEC 4, 7UM62, Manual (€53000-61176-C149- Edition 08.2078 Mounting and Commissioning 33 Commissioning a co es aa oy] Figure 3-40 Triggering oscillographic recording with DIGSI—Example A test measurement record is immediately started. During recording, an indication is given in the left part of the status bar. Bar segments additionally indicate the progress of the procedure. For display and evaluation of the recording, you require one of the programs SIGRA or ComtradeViewer. SIPROTEC 4, 7UM62, Manual 465 (€53000-61176-C149-C, Editon 08,2018

You might also like