Water Heater Refrigerator Freezer Dishwasher Disposal

GAS 1,400 VA 600 VA 1,030 VA 690 VA 1/4hp


4,500 VA 1,500 VA 700 VA 1,100 VA 828 VA 1/3hp
3,500 VA 1,600 VA 800 VA 1,200 VA 1,127 VA 1/2hp
6,000 VA 1,700 VA 900 VA 1,300 VA 1,587 VA 3/4hp
9,000 VA 1,800 VA 1,000 VA 1,400 VA 1,840 VA 1 hp
1,900 VA
2,000 VA

Central Vac Mini Refrig Compactor Insta Hot Range Hood


1,440 VA 170 VA 780 VA 6,670 VA 400 VA
1,600 VA 230 VA 850 VA 700 VA
1,800 VA 340 VA 400 VA

Yellow cells are for Your entries


Enter numerals only, DO NOT type V
Central Air Strip Heat Units
Select Blower/fan Total Load Blue cells are fixed and the first val
5kW + 800VA = 5,800 VA
7.5kW + 800VA = 8,300 VA
8kW + 800VA = 8,800 VA Condensing Units / Heat Pum
9.6kW + 1,200VA = 10,800 VA Select Condensing Unit
10kW + 1,200VA = 11,200 VA 1 ton 1,840VA
12.5kW + 1,600VA = 14,100 VA 1.5 ton 2,200VA
15kW + 1,600VA = 16,600 VA 2 ton 2,850VA
17.5kW + 1,600VA = 19,100 VA 2.5 ton 3,600VA
20kW + 1,600VA = 21,600 VA 3 ton 4,275VA
+ = 3.5 ton 5,000VA
4 ton 5,700VA
5 ton 7,130VA
Microwave
1,630 VA
1,000 VA
1,100 VA
1,200 VA
1,300 VA
1,400 VA
1,500 VA
1,700 VA

Ironing Center
1,500 VA
1,800 VA
2,400 VA

cells are for Your entries


numerals only, DO NOT type VA.

cells are fixed and the first value is the


default

Condensing Units / Heat Pumps Supplementary Heat & Blower


Condensing Unit Heat Pump Select Blower/fan Total Load
1,840VA 2.5 kW + 1,200VA = 3,700VA
2,200VA 2,230VA 3 kW + 1,200VA = 4,200VA
2,850VA 3,100VA 4 kW + 1,200VA = 5,200VA
3,600VA 3,496VA 4.5 kW + 1,200VA = 5,700VA
4,275VA 4,370VA 5 kW + 1,600VA = 6,600VA
5,000VA 5,152VA 6.5 kW + 1,600VA = 8,100VA
5,700VA 5,313VA 7.5 kW + 1,600VA = 9,100VA
7,130VA 6,371VA + = VA
+ = VA
+ = VA
Residential Standard Calculation 9/25/1997 Job Name
by: John Sokolik Version 2010 D
STEP 1 Article 220.42 & 220.52 Company Name
sq. ft General Lighting load VA Company Address
Small Appliance VA City, State, Zip
Laundry circuit VA Telephone and Fax
Gen.Lgt, Sm App.& Laun. Load VA 8/5/2020 12:31
VA @ 100%= VA
VA @ 35% = VA
VA @ 25% = VA
STEP 2 Article 220.50 & 220.51 ✘ General Lighting Demand Load VA
A/C Condenser & Fixed Electric Space Heating QTY Total 0 ###
A/C #1 VA AHU 1 Select VA Qty Total Heat Load VA ###
A/C #2 VA AHU 2 Select VA Qty Total CU Load VA ###
A/C #3 VA AHU 3 Select VA Qty ###
A/C #4 VA AHU 4 Select VA Qty Greater of Heat @ 100% vs.A/C @ 100% VA ###
A/C #5 VA AHU 5 Select VA Qty ###
STEP 3 Article 220.53 Appliance Demand Load VA ###
4,500 VA Water Heater VA ###
1,400 VA Refrigerator VA Dryer Demand Load VA
600 VA Freezer VA D
1,400 VA Dishwasher VA Range Demand Load VA ###
1,127 VA Disposal VA <
400 VA Range Hood VA Service Demand VA >
1,200 VA Microwave VA
✘ 1,440 VA Central Vac VA Demand Load A
170 VA Mini Refrig VA
780 VA Compactor VA Neutral Demand A
6,670 VA Insta Hot VA
1,500 VA Ironing Center VA Min.Service Req. A
select Jacuzzi Tub VA
select Sprinkler Pump VA Min. Feeder size 0
select Well Pump VA Min. Neutral size 0
select Fountain Pump VA Eq. Grding Cond. 0
select Elevator VA Copper
Pool Equip. Panel VA 100% Demand
Garage doors VA No Demand
Welder VA No Demand Total Appliance Load VA
4 or more demand @ 75% plus 100% demand loads VA
STEP 4 Article 220.54
Electric Clothes Dryers
STEP 5 Article 220.55
Electric Ranges Col C demand W
or Number of appliances
Cooktop Col B demand
Check Box for Gas Range Cooktop Col B demand Use this area for your own notes
Oven(s) Col B demand
Oven(s) Col B demand
Number of appliances Dem. Factor 0%
Cooktop & Oven Demand Load W
jmp1jds@comcast.net
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>><<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<

Pool Panel Feeder Calculation (See Note) A B N Continuous Non-continuous


Continuous Motors 0 ...... 0 0 0 Motors Motors
Non-continuous 0 ...... 0 0 0 select 240v select 240v

Spa heater 11 kVA ...... 0 0 select 240v select 240v

Pool heater 3.5 ton ...... 0 0 select 240v select 240v

Pool heater 5 ton ...... 0 0 select 240v select 240v


Pool Light select 0 ...... 0 0 0 select 240v select 240v
Blower select2333 0 240v 0 0 0
other load 0 240v 0 0 0 0.0 Motor Neutral Load
other load 0 240v 0 0 0
Min.Copper Pool Feeder AWG A A A Max.Unbalanced Neutral Load
Minimum Panel Rating A Phase Amperes Neut. load
Company Name
Company Name

Address
Company Address

City, State, Zip Code


City, State, Zip