MAP SENSOR
OUTPUT VOLTAGE INSPECTION
™
Connect the test harness to the ECM (page 5-8). as
Measure the voltage at the test harness terminals
(page 5-9), 34
3.0
CONNECTION: B7 (+)—B1 (
STANDARD: 2.7~3.1V ca
25
The MAP sensor output voltage (above) is meas-
ured under the standard atmosphere (1 atm = 1,030
hPa). 2.0
‘The MAP sensor output voltage is affected by the
distance above sea level, because the output
voltage is changed by atmosphere. Ae
Check the sea level measurement and be sure that |"
the measured voltage falls within the specified
value.
10
05
0 500-1000 15002000 :m
(1, 650) (3, 300) (4,950) (6, 600) (feet)EL SYSTEM (Programmed Fuel Injection)
MAP SENSOR REMOVAL/INSTALLA-
TION
Open and support the front end of fuel tank (page
3-4)
Disconnect the MAP sensor connector.
Disconnect the vacuum tube y
Remove the screw and MAP sensor from the air pr ee
cleener housing
Installation is in the reverse order of removal.