Dd Hvunoai TEST REPORT OF INDUCTION MOTOR [Customer Name: SH @eIAe [Manufacture Name: Hyundai Heavy Industries Co.,Ltd Project Name: Banggai Ammonia Plant Serial No. 16F414008-001 Model No. __HLS165RB259R2D Tiem No. BAP-THMEC-POO117-007 Type: HL-XD_[Frame:__160L Bearing No. _D.E: 63092ZC3__N.D.E: 63092203 15 KW] 420 Volts] 27.8 _ Amps 4 Poles 50 Hz]_1470__ 1pm Enc: 1P55 Mounting] *Rotation —C.W Rotor Cage @} Rating: 81 Tnsul.Class: F NIA CCW © Wound Etficiency (%) 90.6 Max Amb.Temp Service Factor Characteristics Test tance 0.44600 at 23 & | No Load Locked Rotor Test U-Vv vV-W uw Worage _(v) | 420.0 N/A N/A | Stator Go [o.4as00 @ [0.44700 g]o.44500 @ Frequency (Hz) 50 N/A N/A Rotor Coil N/A 2 N/A Qt N/A 2 (Current (A) 11.72 N/A N/A lLoss___(kw)_| 0.630 N/A Nimans] Seeman Volga: 7 y Load Characteristic(Circle Method) [tor*"Toraue) _(%6) 25 50 75 100 Torque and starting current Curent (A) N/A N/A N/A 26.80 N/A Max. Torque & 240.00 Efficiency (6) _| N/A | N/A | N/A | 90.90 | N/A_| Starting Current ]_172.00 Power Factor _(%) N/A N/A N/A 84.64 N/A _| Starting Torque (s 200.00 Slip (%) N/A N/A N/A 1.67 N/A Rated Torque (Kg.m)| 9.9 Temperature Rise Test 100% N/A Vv N/A A N/A hrs N/A __rpm_Amb.Temp: N/A c Stator Rotor Bearing Load (%) - a 5 Core. Frane = ee va Core. Brush pe | NDE 100 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Over Current Test Vibration Test Note 160_% Load 15 sec. ~~ Over speed Test x. iP 125% Syn.Speed___120 sec insulation Resistance (0) (D.C. 500 V) — < mm/sirms)} Slator Coil Before Above 1000 After Above 1000 . J rnmiston) Rotor Coil Before N/A __ After N/A Position |Horizontal] Vertical Axial Tested By E.T.D Before N/A___ After N/A DE 10.3 [0.4 [0.2 Jo.3 Jo.2/0.3 Heater Before N/A__ After N/A NDE {0.4 |0.6 ]0.3 [0.4 N/A High Voltage Test Noise Test Stator Coil 1840 Vv 60_sec 74.6 dB(A) at 1M Rotor Coil NA Vv N/A_sec Accessories and other data ETD [WAV N/A sec Space neater PNA Phase N/A (W) Heater Lowa v N/A sec. pace neater NWA __W)__N/A_@) Name of item Accessory type. Oy Check result Remark, Winding sensor N/A N/A N/A N/A Bearing sensor NIA NA A N/A Remarks: = Rotation & Terminal on View Coupling Side * T.M: Thermo Meter Method * R.M : Resistance Method + Earthing Test : Good + Type of Ex-Protection : Ex d IIB T4 IECEx Certificate ig pe of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres {ores and dota of the IECEx Scher vist wir ecoxcom Contiicate No: IECEx BAS 13.0076x Issue No.0 ‘Coricate isto Status Current Date of sus: 2oiaor-a1 Page tof 3 Applicant Hyundai Heavy Industries Company Limited Electro Electric Systems Division 4 Jeonha-Dong, Bong-Gu Uisan City 682-792 Korea, Republic of Electical Apparatus: A range of motors of frame size 160M to 200LL. Optional eecessory Type of Protection: _Flameproot and flameprootincreased safety, Marking: Ex d lB T4Ta-20°C to +60°C Gb Exe lI T4 Ta -20°C to 460°C Gb Approved for issue on behalf ofthe IECEX po MPourey Contication Body: Position: Goneral Manager ‘Signature: (for printed version) 4. This certifcate and schedule may only be reproduced in ful isnot transferable and remains the property of te issuing body. ‘suthentoty ofthis certificate may Be varied by visting the Official ECE Websito, Certificate ised by: ‘SCS Baseefa Limited pocina Sutere Pak mee Senton SGS Baseefa) beyshire cy one United Kingdom IECEx Certificate of Conformity Certificate No, VECEx BAS 18.076x Dato of issue: 2oieorst save No: 0 Page 2013 Manufacturer: Hyundai Heavy Industries Company Limited Etectro Electric Systems Division + Jeonna-Dong, Bong-Gu isan Cty 82-702, Korea, Republic of ‘Additonal Manufacturing location @r “This certificate is issued as verfleation that a sample(s), representative of production, was assessed and tested and {ound o comply with the FEC Standard lst below and that the manufacturers qually systam, relating tothe Ex produets| ‘covered by this certificate, was assessed and found to comply withthe IECEx Qualfy system requirements. This ‘certtcat fs granted subject othe conditions as set out in IECEX Scheme Rule, IECEX 02 and Operational Documents ‘as amended STANDARDS: ‘The electrical apperatus and any acceptable variations to it spectied in the schedule of this certificate and the identified documents, was found to comply wit the flowing standards: 1EC 60079.0 : 2007-10 Explosive atmasphores - Part O:Equipment - General requrements Editon: 5 IEC 60079-1 : 2007-04 Explosive atmospheres -Pat 1: Equipment protection by fameproof enclosures Editon: 6 EC 6079-7 : 2006-07 Explosive atmospheres - Part 7: Equipment protection by increased safely “e* Eéltion: 4 This Cerificate does not indicate compliance wih electrical safety and performance requirements other than those ‘expressly Included i the Standards listed above. ‘TEST & ASSESSMENT REPORTS: A sample(s) ofthe equipment ised has successfully met the examination and test requiremants as recorded in ‘Test Report (GerBASIEXTR13.0150/00 ‘Quality Assessment Reoor GBIBASIQARO9.0004/03, IECEx Certificate of Conformity Certticate No, IECEx BAS 13.0076x Date of Issue 2014-01-31 Issue No.0 Page 30f 3 Schedule EQUIPMENT: Equipment and systems covered by this certificate areas follows: The range of 8 motors of rame size 160M to 200LL comprises a stator kame, end shields, terminal nirace plato main {and an optional auxiary terminal box al manufactured fom cat ron, The singie ended civ shaft fs supported by rong ‘slement bearings and has an external cooing fan al the non-orive end. The motors may be fol mounted or mouse Oy & {rive end lange. The end:-sield and terminal box fasteners are hexagon socket head type with a minimum grade of 12.9 Heel, The frame can be provided wih a terminal neck and adaptor plate forthe main terminal box and an adaptor plate or terminal neck forthe attachment of an auxllay terminal box. The main terminal bax may be a fameproof enclosure within te. rovisions of tis reportlertiicate or an increased eafay torminal bax to IECEx BAS 10,0066 or Baseefa 1OATEXO139U. (Cabie glands to IECEx BAS 06.0013 or IECEx SIR 07.0096X and cable bushings to IECEx PTB 06.0090) are provided tween the motor frame and the main terminal box and betwoen the mote ram and auxiary Wrminel box respectively, ‘The 2 poe to 8 pole motors are rated up to GB0V SOIEOHz and have a maximum rating as indcated below for use in a ‘maximum ambient temperature of 40°C. The motors ae de-ated as indicated below for use i a Maxum ambient Temperature of 60°C. Maximameating Frame size aa Taw 202. 60. 2a 7800 2a 80d, 30.0 200 200 Zoot 294 ‘The motors continuously rated for St cuty when connected to @ 3 phase eupply having form and symmetry not worse than ‘that defines in IEC60094-1 and operated wit the defined vatage anc frequency nits for Zane A’ Cable entry notes are provided as specified on the certified drawings forthe accommodation of fameproo cable entry devices, with oF without he interposition ofa famoproot threaded adap. Unused entries oe to be fled wih sulabe ‘certited famepront stopping plugs CONDITIONS OF CERTIFICATION: YES as shown below: 4. The motors are provided with lampath gaps which are less than those permitied by IEC 60078-1 and are not to be enlarged in service 2, When used on variable frequency supplies, the thermal protection devices must be connected to a protection circuit to {o-oneraise the machine inthe event of operation o the protection devices, 3. When used on a variable frequency up to @ maximum of Hz for 2 pole motors and GOHz for motors with greater than 2 poles tne winding thermal sensors must be interlocked to de-energise the machine ala winding temperature of 145°C 4. The motors may be used within an ambient temperature of -20°C 10 -55°C when the internal temperature is monitored by the winding temperature sensors andthe motors interlocked to prevent the motor from being energised unlass the internal temperature is greater than -200C and the heaters are de-energiced when the motors energised. 5. The Ex d motors may be marked IPS6, The Ex de motors may be marked IPSS if filed with increased safety terminal Doxes to ECEx BAS 10.0000U without a breathed 6. Any cetiied equipment (aot components) supplied by others isto be attached using the mounting arrangement rovided by the motor manufacturer, and is fo be sutable fr the gas group, temperature classficaion and temperature ange of the motor ‘Amex: Annex for ECEx BAS *3.0076X pa SGS Baseefa Limited Rocthand Business Pak | stagen ane, Buxton, Derbyshire een iron im (Baseefa United Kingdom ANNEX to IECEx BAS 13,0076X Issue No. 0 Date: 2014/01/30 Variation 0.1 ‘To permit increased outputs as specified wit a temperature classification of 4 at an ambient temperature between 40°C and 60°C on a variable frequency supply rom inverters upto & maximum of Oz for 2 pole motors and GOH= for motors wih greater than 2 poles 2s indicted below. Type Current range Switching frequency yuna N100 Series UptoS2A ‘3KHE or higher Hyundal N700 Senos Upto 2608 ‘kHz or higher Hyundai N8OO Serias Upto 3854 ‘kz or higher Variation 0.2 Topermittemperatue classifications of 2 pole to 8 pole machines of TS and T6 Ta 40°C to +60°C when de-ated as speced on a ssusoidal supply Variation 0.3, To permit service factor greater than 1.0 when the motors are de-ated as specified Variation 04 Topermitthe use on supplies within the volage and requency lenis fer Zone Bae defined in JECEOO34-1 when de-ated as specified Variation 05 To permit perodic duty cycles of $2, $3, 4, 6 fr temperature classes T1103 only as defined in I5C60034-1 For S2 duty cyces the maximum time s 90 minutes with intervals of 10,30, 60 and 90 minutes. Fer 3, $4, S6 he duy cycle shal be 10 minutes and th eye curation factor shal be TOM. 25%, 40%, or 60% Variation 0.8 “To permit the use within an ambient temperature range of -20°C to 56°C the mar must be ited wth a space heater and winding senor to moniter he intemal temperature to maintain the lemperaiute above 20°C “The Ex terminal box used must have been subject toa roune pressure estat 1.62 times the reference pressure stated on the raving. Exe terminal boxes toIECEx BAS 10.0066 are permit Variation 0.7 “To permit marking IP rating PSE to 1EC60S29 Variation 0.8 “To permit alemative temperature clasifieation of T3, T2 and T1 without any design changes to the machines of an increase in the maximum ambient temperate Variation 0.8 ‘To permit the ternative cooling arangements TEFC (independent fan ckiven by ausiiary motor) and TEAO. For TEFC the cooling it provided from a remote fan driven by an auxitary motor and ducting, Page 1 of 2 SGS Baseefa Limited Rockhead Business Park ‘Staden lane, Buxton, Derbyshire SK17 9Rz United Kingdom Baseefa ANNEX to IECEx BAS 13,0076X Issue No. 0 Date: 2014/01/30 For TEAC tne cooing is provide by the driven machine. In both cases the fan, fan cowing ducting te. is supplied by cthors. Timm Air Velo (eee) fx Ware 96 and number of poss Frame Sie 2. 4 ‘oP F 600A ies. is 70. 75 604. 145. 125 70, 70 1800 180. 18.5 a5. 35. 0 3500 755. 35. Eo 200 16.0 158 105 105, ZOOL 160 156. 108 05. Variation 0.10 To permit bearing temperature detectors, vibration ‘motor manufacturer. and heater elements fo windings Variation 0.44 Probes etc, supplied by others attached by the mounting methods provided by the To permit motors with pole number greater than 8, and mul speed motors upto @ maximum of 3600 revimin. Variation 0.12 ‘To permit the use of a drain IECEx BAS 10.0120X or IECEx SIR 08,0131X Page 2 of 2 | Certificate Number Issued 31 January 2014 Baseefa3ATEX0087X SGS Baseefa Page 1of 5. : EC - TYPE EXAMINATION CERTIFICATE 2 Equipment or Protective System Intended for use in Potentially Explosive Atmospheres Directive 94/9/EC 3° EC- Type Examination Baseeful3ATEX0087X, Certificate Number: 4 Equipment or Protective System: A Range of IIB Motors of Frame Size 160M to 200LL 5 Manufacturer: Hyundai Heavy Industries, Company Limited. 6 Address: Electro Electric Systems Division 1 Jeonha-Dong, Dong-Gu, Ulsan City 682-792, Korea 7 This equipment or protective system and any acceptable variation thereto is specified in the schedule to this certificate and the documents therein referred to 8 Bascefa, Notified Body number 1180, in accordance with Article 9 of the Council Directive 94/9/EC of 23 March 1994, certifies that this equipment or protective system has been found to comply with the Essential Health and Safety Requirements relating to the design and construction of equipment and protective systems intended for use in potentially explosive atmospheres given in Annex I! tothe Directive ‘The examination and test results are recorded in confidential Report No, GR/BAS/EXTR3.0150/00 9 Compliance with the Essential Health and Safety Requirements has been assured by compliance with EN 60079-0: 2009 EN60079-1 007 EN 6079-7; 2007 except in respect of those requirements listed at item 18 of the Schedule 10 Ifthe sign “X” is placed after the certificate number, it indicates that the equipment or protective system is subject to special conditions for safe use specified in the schedule to this certificate, IL This EC - TYPE EXAMINATION CERTIFICATE relates only to the design and construction of the specified equipment or protective system. Further requirements of the Directive apply to the manufacturing process and. supply ofthis equipment or protective system. These are not covered by this certificate 12 ‘The marking ofthe equipment or protective system shall include the following @ 2G Ex d MB TS Ta-20°C to +60°C Gh oF Ex de IB T4 Ta -20°C to +60°C Gb Bascefa Customer Reference No. 6014 Project File No, 13/0368 “This document is iss by the Company subject w is General Condon: for Ceriication Services accesible at pilus mien Tama ‘Coudiionsasnx and the Supplementary Terms and Conditions accesible a pny pesca comes sp Altntion s dao the limitation of Hiab, indemnification and jwrisiton issues defined therein. Any holder ofthis docoment advised tha intermaton contained hee eect the Company's findings athe tne o ts intervention only and within the Fits of Cen insrctions, i ary. I does not necewaly indicate thatthe ‘yuipment may be used in particular industries or circumstances. The Companys sole responsiblity is to it Client and this document doesnot exonerate Dates to transaction fro exerisng al their rights and obligations unde the transaction documents. This document cant be reproduced execpt in fil Schedule ineide, without prior writen approval ofthe Company. Any unauthorized alteration, forgety or fesieaton ofthe const of appearance ofthis document is unlawrl and fenders may be prosecuted othe fullest extent ofthe av SGS Baseefa Limited VT a Rockhead Business Park, Staden Lane, < am Buxton, Derbyshire SK17 ORZ Telephone +44 (0) 1208 766600 Fax +44 (0) 1298 766601 RS SINCLAIR ‘e-mail infow@bazeata.com wob site ywwww.bascefa.com GENERAL MANAGER ogoeel wage Na R Regie sts: one Bsn ar hema Chir CHEN On behalf of SGS Baseefa Limited Certificate Number Issued 31 January 2014 Baseefa13ATEX0087X SGS_ Baseefa Page 2 of 5 B Schedule 4 Certificate Number Baseefal3ATEX0087X 1S Description of Equipment or Protective System The range of IIB motors of frame size 160M to 200LL comprises a stator frame, end shields, terminal interface plate main ‘and an optional auxiliary terminal box all manufactured from cast iron. The single ended drive shaft is supported by rolling clement bearings and has an external cooling fan at the non-drive end, The motors may be foot mounted or mounted by a drive end flange. The terminal box fasteners are grade 12.9 steel ‘The frame can be provided with a terminal neck and adaptor plate for the main terminal box and! an adaptor plate or terminal neck for the attachment of an auxiliary terminal box. The main terminal box may be a flameproof enclosure ‘within the provisions of this certificate or an increased safety terminal box to Baseefal0ATEXO139U. Cable glands to ‘SiraO9ATEX1092 and cable bushings to PTB97ATEX1047U are provided between the motor frame and the main terminal bbox and between the motor frame and auxiliary terminal box respectively. The 2 pole to 8 pole motors are rated up to 690V SO/60Fz and have « maximum rating as indicated below for use in a ‘maximum ambient temperature of 40°C. The motors are de-rated in aceordance with table 9 of EN60034-1 for use in a ‘maximum ambient temperature of 60°C. Frame size | Maximum rating (KW), 160M 202 160L 247 180M. 247 T80L 30.0 200 40.0 (2000 49.4 The motors are continuously rated for S1 duty when connected to a 3 phase supply having form and symmetry not worse than that defined in EN 60034-1 and operated within the defined voltage and frequency limits for Zone A Cable entry holes are provided as specified on the certified drawings for the accommodation of flameproof cable entry devices, with or without the interposition of a flameproof thread adapter. Unused entries are to be fitted with suitable Certified flameproof stopping plugs. ‘The cable entry devices, thread adapters and stopping plugs shall be suitable for the equipment, the cable and the ‘conditions of use and shall be certified as Equipment (not a Component) under an EC Type Examination Certificate to Directive 94/9/EC. Variation 0.1 To permit increased outputs as specified with a temperature classification of T4 at an ambient temperature between 40°C ‘and 60°C on a variable frequency supply from inverters up to a maximum of 60Hz for 2 pole motors and 90H.z for motors with greater than 2 poles as indicated below. Type ‘Current range | Switching frequenc) Tiyundai N100 Series Upio9.2A 3 KHz oF higher Hyundai N700 Series Upto 260 A [3 kiz or higher [Hyundar N800 Series ip to 385A 3dIz or higher Certificate Number Issued 31 January 2014 Baseefa13ATEX0087X SGS" Baseefa Page 3 of 5 Variation 0.2 ‘To permit temperature classifications of 2 pole to 8 pole machines of TS and T6 Ta +40°C to +60°C when de-rated as specified on a sinusoidal supply. Variation 0.3 ‘To permit a service factor greater than 1.0 when the motors are de-rated as specified. Variation 0.4 To permit the use on supplies within the voltage and frequency limits for Zone B as defined in EN 60034-1 when de-rated as specified, Variation 0.5 ‘To permit periodie duty cycles of S2, $3, S4, $6 for emperature classes TI to T3 only as defined in EN 60034-1 For S2 duty cycles the maximum time is 90 minutes with intervals of 10, 30, 60 and 90 minutes. For $3, $4, $6 the duty cycle shall be 10 minutes and the cyclic duration factor shall be 15%, 25%, 40%, or 60%. Variation 0.6 To permit the use within an ambient temperature range of -20°C to -55°C the motor must be fitted with space heater and ‘winding sensors to monitor the internal temperature to maintain the temperature above 20°C. ‘The Bx d terminal box used must hae been subj trove presets t 1.62 times the reference peau sted on x ri boxes to BasefaIOATEXOIS9U ae pied Variation 07 To permit marking I ang IPS o ENGOS29 Variation 08 To permit alternative temperature classification of T3, T2 and TI without any design changes to the machines or an increase in the maximum ambient temperature. Variation 0.9 ‘To permit the alternative cooling arrangements TEFC (independent fan driven by auxiliary motor) and TEAO, For TEFC the cooling is provided from a remote fan driven by an auxiliary motor and ducting. For TEAO the cooling is provided by the driven machine. In both cases the fan, fan cowling ducting etc. is supplied by others. ‘Minimum Air Velocity (m/sec) for ame size and number of poles Frame Size 2P aP. P ‘8P 160M. 143 125 7.0, 7.0 T60L 145 125 7.0. 7.0, 180M 15.0 155 BS 85. 1s0L | 15.0 155 85 aS: 200k | 16.0 156, 105 105 2o0Lt | 160) 15.6 105 105 Certificate Number Issued 31 January 2014 Baseefat3ATEXOO87X SGS Baseefa Pago 4of 5. Variation 0.10 To permit bearing temperature detectors, vibration probes etc. supplied by others attached by the mounting methods Provided by the motor manufacturer, and heater elements for windings. Variation 0.11 ‘To permit motors with pole number greater than 8, and multi speed motors up to a maximum of 3600 revimin. Variation 0.13, ‘To permit the use of a drain Baseefal 0ATEX0262X or Sira 09ATEX1320X. 16 Report Number Bascefa Certification Report GB/BAS/EXTR13.0150/00 17 Specific Conditions of Use 1, The motors are provided with flamepath gaps which are less than those permitted by EN60079-1 and are not to be enlarged in service, 2. When used on variable frequency supplies, the thermal protection devices must be connected to a protection circuit to de-energise the machine in the event of operation of the protection devices, 3. When used on a variable frequency up toa maximum of 60Hz for 2 pole motors and 90H for motors with greater than 2 poles the winding thermal sensors must be interlocked to de-energise the machine at a winding temperature of 145°C, 4 The motors may be used within an ambient temperature of -20°C 10 -35°C when the internal temperature is ‘monitored by the winding temperature sensors and the motor is interlocked to prevent the motor from being ‘energised unless the internal temperature is greater than -20°C and the heaters are de-energised when the motors energised. 5. The Ex d motors may be marked IPS6. The Ex de motors may be marked IPS6 if fitted with increased safety terminal boxes to Baseefu0ATEXO139U without a breather/drain. 6. Any certified equipment (not components) supplied by others is to be attached using the mounting arrangement provided by the motor manufacturer, and is to be suitable for the gas group, temperature classification and {temperature range of the motor. 18 Essential Health and Safety Requirements All relevant Essential Health and Safety Requirements are covered by the standards listed at item 9. 19 Drawings and Documents Number Sheet Issue Date Description 3M-168586 1of! 2013-05-28 General Assembly ~ Frame size 160M 3M-168098 — Lof! 2013-05-14 General Assembly ~ Frame size 160L 3M-168590 lof! 0_—2013-05-28 General Assembly ~ Frame size 180M. 3M-168170 lof] 0 -——2013+05-16 General Assembly ~ Frame size 1801 3M-168604 1of1 02013-0528 General Assembly — Frame size 2001, 3M-168254 Lo] 2013-05-17 General Assembly - Frame size 200LL 3M-168339 1 of 1 2013-05-21 Main Terminal Box Assembly - Ex d Frame size 160M to 1801, 3M-168372 of | 2013-05-22 Main Terminal Box Assembly - Ex d - Frame size 200L to 225 3M-168397 1 of | 2013-05-22 Auxiliary Terminal Box Assembly - Ex d - Frame size 71 to 280LL 3M-126701 1 of | 2010-03-01 Accessory T/box Assembly ~ Ex d IIC~ Frame size 71 to 280LL. 3M-I71484 1 of 1 2013-08-24 General Assembly for Drain Details ~ Frame size 71 to 280LL Certificate Number ! Issued 31 January 2014 Baseefa13ATEX0087X Baseefa Page 5 of 5 Number Sheot_ Issue —-Date_—_—Deseription 3M-I71569 ofl 02013-0826 General Assembly for Bearing Cap Drill Deals Frame size 160M {0 200LL IM.127621 Loft 020100401 Fan Assembly 4M-096522 1of! 02010-0205 Bushing 4M-097073 Loft 02010-0402 Cable Gland 4M-110932 Loft —@-—=—«2013-07-22 Cable Gland 3M-169996 ofl —-2013407.08 Name Plate Arrangement 4M-104206 of! 0 2011-11-04 Rating Pate 4M.003932 of! 0 2002-08-06 Gas and Cable Temperature Waring Plate AM-110755 —10f1 2013-07-08 Marking Pate~ Group B- Ex dide Hu 1t027 0 2013-10-10 Technical Description HL-XD motors Frame size 71 to 280 Exdllb- inc 2013-001- Ro ‘These drawings are common to other certificates a indicated on, and held on, general file 6014/01

You might also like