Produced on 18/04/2020 with Xpress Selection V8.9.0 - database DIL 15.2.

Project name Independence ship agents office


Project address Argentina
Reference Barbara Matilla
Client name Independence ship agents SA
Revision DUO two

Selection parameters of the indoor units can be found under the chapter Indoor unit details
Selection parameters of the outdoor units can be found under the chapter Outdoor unit details
Only the data published in the data book are correct. This program uses close approximations of these data.

1. Material List
Model Qty Description
REYQ18TY1 2 Heat recovery VRV IV HR
BS4Q14AV1 2 Branch selector unit
BSQ160AV1 2 Branch selector unit
BSQ250AV1 2 Branch selector unit
FXAQ20AVM 2 VRV A(AVM) - Unidad montada en pared
FXMQ80PVE 2 VRV M - Unidad de conducto montada en el techo
FXNQ25MAVE 1 VRV N - Unidad de suelo oculta
FXNQ32MAVE 12 VRV N - Unidad de suelo oculta
FXNQ40MAVE 9 VRV N - Unidad de suelo oculta
FXNQ50MAVE 2 VRV N - Unidad de suelo oculta
KHRP25A72T + KHRP25M72TP 6 Refnet branch piping kit
KHRP26A22T 15 Refnet branch piping kit
BRC1E63 28 Wired Remote Controller (Navigation Remote Controller)
KHFP26A100C 1 Closed pipe kit
R410A 28,8kg Extra refrigerant charge
Piping ¼" 101,0m
Piping ⅜" 84,5m
Piping ½" 132,0m
Piping ⅝" 117,5m
Piping ¾" 63,0m
Piping ⅞" 39,0m
Piping 1⅛" 66,0m

2. Indoor Unit Details


2.1. Table of Abbreviations
Name Logical name of the device
FCU Device model name
Tmp C Indoor conditions in cooling (dry bulb temp. / RH)
Rq TC Required total cooling capacity
Max TC Available total cooling capacity
Rq SC Required sensible cooling capacity
Max SC Available sensible cooling capacity

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 1
Tevap Evaporating temperature of indoor unit coil
Tmp H Indoor temperature in heating
Rq HC Required heating capacity
Max HC Available heating capacity
Airflow Supplied airflow
Sound Sound pressure low and high
PS Power supply (voltage and phases)
MCA Minimum Circuit Amps
WxHxD WidthxHeightxDepth
Wght Weight of the device

2.2. Cerrito - REYQ18TY1


Capacity data at conditions and connection ratio (118%) as entered
Name FCU Tmp C Rq TC Max TC Rq SC Max SC Tevap Tmp H Rq HC Max HC Airflow
°C kcal/h kcal/h kcal/h kcal/h °C °C kcal/h kcal/h m³/min
Central FXMQ80PVE 24,0 / 50% n/a 6711 n/a 5397 6,0 20,0 n/a 8604 25,0
Server FXAQ20AVM 24,0 / 50% n/a 1678 n/a 1488 6,0 n/a n/a n/a 9,1
Salon FXNQ50MAVE 24,0 / 50% n/a 4173 n/a 3005 6,0 20,0 n/a 5421 14,0
Salon FXNQ40MAVE 24,0 / 50% n/a 3355 n/a 2419 6,0 20,0 n/a 4302 11,0
Salon FXNQ40MAVE 24,0 / 50% n/a 3355 n/a 2419 6,0 20,0 n/a 4302 11,0
Salon FXNQ40MAVE 24,0 / 50% n/a 3355 n/a 2419 6,0 20,0 n/a 4302 11,0
Privado Contador FXNQ32MAVE 24,0 / 50% n/a 2710 n/a 1961 6,0 20,0 n/a 3442 8,0
Salon FXNQ32MAVE 24,0 / 50% n/a 2710 n/a 1961 6,0 20,0 n/a 3442 8,0
Salon FXNQ32MAVE 24,0 / 50% n/a 2710 n/a 1961 6,0 20,0 n/a 3442 8,0
Salon FXNQ32MAVE 24,0 / 50% n/a 2710 n/a 1961 6,0 20,0 n/a 3442 8,0
Office FXNQ40MAVE 24,0 / 50% n/a 3355 n/a 2419 6,0 20,0 n/a 4302 11,0
Salon FXNQ40MAVE 24,0 / 50% n/a 3355 n/a 2419 6,0 20,0 n/a 4302 11,0
Privado Director FXNQ32MAVE 24,0 / 50% n/a 2710 n/a 1961 6,0 20,0 n/a 3442 8,0
Privado Contador FXNQ25MAVE 24,0 / 50% n/a 2108 n/a 1582 6,0 20,0 n/a 2753 7,0

Required cooling capacity towards the outdoor unit: 44998kcal/h.


Required heating capacity towards the outdoor unit: 55497kcal/h.
The sum of the required indoor unit capacities is 44998kcal/h for cooling and 55497kcal/h for heating.
However, the outdoor unit selection uses reduced load values for cooling of 22499kcal/h (= -50%) and for heating
of 27749kcal/h (= -50%).
Be aware that unrealistic reductions may lead to reduced comfort levels, different noise levels or increased wear
and tear.

Name Sound PS MCA WxHxD Wght


dBA A mm kg
Central 39-43 220V 1ph 2,3 1000×300×700 36
Server 28,5-33 220V 1ph 0,6 795×290×266 12
Salon 35-40 220V 1ph 0,6 1350×610×220 27
Salon 34-39 220V 1ph 0,6 1070×610×220 23
Salon 34-39 220V 1ph 0,6 1070×610×220 23
Salon 34-39 220V 1ph 0,6 1070×610×220 23
Privado Contador 33-36 220V 1ph 0,6 1070×610×220 23
Salon 33-36 220V 1ph 0,6 1070×610×220 23
Salon 33-36 220V 1ph 0,6 1070×610×220 23
Salon 33-36 220V 1ph 0,6 1070×610×220 23
Office 34-39 220V 1ph 0,6 1070×610×220 23
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 2
Salon 34-39 220V 1ph 0,6 1070×610×220 23
Privado Director 33-36 220V 1ph 0,6 1070×610×220 23
Privado Contador 33-36 220V 1ph 0,3 930×610×220 19

Outdoor unit placed at the same level as the indoor units.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 3
2.3. Libertad - REYQ18TY1
Capacity data at conditions and connection ratio (118%) as entered
Name FCU Tmp C Rq TC Max TC Rq SC Max SC Tevap Tmp H Rq HC Max HC Airflow
°C kcal/h kcal/h kcal/h kcal/h °C °C kcal/h kcal/h m³/min
Salon FXNQ50MAVE 24,0 / 50% n/a 4173 n/a 3005 6,0 20,0 n/a 5421 14,0
Salon FXNQ40MAVE 24,0 / 50% n/a 3355 n/a 2419 6,0 20,0 n/a 4302 11,0
Salon FXNQ40MAVE 24,0 / 50% n/a 3355 n/a 2419 6,0 20,0 n/a 4302 11,0
Salon FXNQ40MAVE 24,0 / 50% n/a 3355 n/a 2419 6,0 20,0 n/a 4302 11,0
Salon FXNQ32MAVE 24,0 / 50% n/a 2710 n/a 1961 6,0 20,0 n/a 3442 8,0
Salon FXNQ40MAVE 24,0 / 50% n/a 3355 n/a 2419 6,0 20,0 n/a 4302 11,0
Salon FXNQ32MAVE 24,0 / 50% n/a 2710 n/a 1961 6,0 20,0 n/a 3442 8,0
Salon FXNQ32MAVE 24,0 / 50% n/a 2710 n/a 1961 6,0 20,0 n/a 3442 8,0
Sala priv FXNQ32MAVE 24,0 / 50% n/a 2710 n/a 1961 6,0 20,0 n/a 3442 8,0
Sala reuniones FXNQ32MAVE 24,0 / 50% n/a 2710 n/a 1961 6,0 20,0 n/a 3442 8,0
Sala reuniones FXNQ32MAVE 24,0 / 50% n/a 2710 n/a 1961 6,0 20,0 n/a 3442 8,0
Central FXMQ80PVE 24,0 / 50% n/a 6711 n/a 5397 6,0 20,0 n/a 8604 25,0
Server FXAQ20AVM 24,0 / 50% n/a 1678 n/a 1488 6,0 n/a n/a n/a 9,1
Sala priv FXNQ32MAVE 24,0 / 50% n/a 2710 n/a 1961 6,0 20,0 n/a 3442 8,0

Required cooling capacity towards the outdoor unit: 44955kcal/h.


Required heating capacity towards the outdoor unit: 55325kcal/h.
The sum of the required indoor unit capacities is 44955kcal/h for cooling and 55325kcal/h for heating.
However, the outdoor unit selection uses reduced load values for cooling of 22477kcal/h (= -50%) and for heating
of 27663kcal/h (= -50%).
Be aware that unrealistic reductions may lead to reduced comfort levels, different noise levels or increased wear
and tear.

Name Sound PS MCA WxHxD Wght


dBA A mm kg
Salon 35-40 220V 1ph 0,6 1350×610×220 27
Salon 34-39 220V 1ph 0,6 1070×610×220 23
Salon 34-39 220V 1ph 0,6 1070×610×220 23
Salon 34-39 220V 1ph 0,6 1070×610×220 23
Salon 33-36 220V 1ph 0,6 1070×610×220 23
Salon 34-39 220V 1ph 0,6 1070×610×220 23
Salon 33-36 220V 1ph 0,6 1070×610×220 23
Salon 33-36 220V 1ph 0,6 1070×610×220 23
Sala priv 33-36 220V 1ph 0,6 1070×610×220 23
Sala reuniones 33-36 220V 1ph 0,6 1070×610×220 23
Sala reuniones 33-36 220V 1ph 0,6 1070×610×220 23
Central 39-43 220V 1ph 2,3 1000×300×700 36
Server 28,5-33 220V 1ph 0,6 795×290×266 12
Sala priv 33-36 220V 1ph 0,6 1070×610×220 23

Outdoor unit placed at the same level as the indoor units.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 4
3. Outdoor Unit Details
3.1. Table of Abbreviations
Name Logical name of the device
Model Device model name
Tmp C Outdoor temperature in cooling
CC Available cooling capacity
Rq CC Required cooling capacity
Tmp H Outdoor conditions in heating (dry bulb temp. / RH)
HC Available heating capacity (integrated heating capacity)
Rq HC Required heating capacity
Piping Largest distance from indoor unit to outdoor unit
Bse Refr Standard factory refrigerant charge (5m actual piping length)
excluding extra refrigerant charge
For calculation of extra refrigerant charge refer to the databook
Ex Refr Extra refrigerant charge
PS Power supply (voltage and phases)
MCA Minimum Circuit Amps
WxHxD WidthxHeightxDepth
Wght Weight of the device

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 5
3.2. Outdoor Details
Name Model Comb Tmp C CC Rq CC Tmp H HC Rq HC
% °C kcal/h kcal/h °C kcal/h kcal/h
Cerrito REYQ18TY1 118 32,0 38406 22499 0,0 / 50% 33134 27749
Libertad REYQ18TY1 118 32,0 37231 22477 0,0 / 50% 32702 27663

Name Model Piping Refrigerant


m Type Bse Refr Ex Refr
kg kg
Cerrito REYQ18TY1 62,0 R410A 11,8 13,0
Libertad REYQ18TY1 77,0 R410A 11,8 15,8

Name Model PS MCA WxHxD Wght


A mm kg
Cerrito REYQ18TY1 400V 3ph 36 1240×1657×765 342
BS 3 BS4Q14AV1 230V 1ph 0,4 370×298×430 17
BS 4 BSQ160AV1 230V 1ph 0,1 388×207×326 11
BS 5 BSQ250AV1 230V 1ph 0,1 388×207×326 14
Libertad REYQ18TY1 400V 3ph 36 1240×1657×765 342
BS 6 BS4Q14AV1 230V 1ph 0,4 370×298×430 17
BS 7 BSQ160AV1 230V 1ph 0,1 388×207×326 11
BS 8 BSQ250AV1 230V 1ph 0,1 388×207×326 14

4. Piping Diagrams
Pipes marked with * in the diagrams must be connected to the device with a reducing joint.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 6
4.1. Piping Cerrito
Cerrito
REYQ18TY1

9,0m [4] 17,0m


⅝"×1⅛"×⅞" ¼"×½"
KHRP25A72T +
KHRP25M72TP
Server
FXAQ20AVM
1,0m 1,0m
⅝"×1⅛"×⅞" ⅜"×⅞"×¾" BS 3
KHRP25A72T +BS4Q14AV1 1,5m
KHRP25M72TP ⅜"×⅝" *

Central
FXMQ80PVE
15,0m
¼"×½"

Privado Director
FXNQ32MAVE
6,0m
¼"×½"

Office
FXNQ40MAVE
8,0m 1,0m
⅜"×⅝" * ¼"×½"
KHRP26A22T

Privado Contador
FXNQ25MAVE
4,0m
¼"×½"

Privado Contador
FXNQ32MAVE
15,0m [4] 1,0m 1,0m 2,0m
½"×1⅛"×¾" ⅜"×⅝"×½" ⅜"×⅝" ¼"×½"
KHRP25A72T + KHRP26A22T
KHRP25M72TP
BS 4 Salon
BSQ160AV1 FXNQ32MAVE
2,0m 2,0m
⅜"×⅝" ¼"×½"
KHRP26A22T

Salon
FXNQ32MAVE
3,0m 2,0m
⅜"×⅝" ¼"×½"
KHRP26A22T

Salon
FXNQ32MAVE
3,0m
¼"×½"

Salon
FXNQ40MAVE
15,0m 1,0m 2,0m
⅜"×¾"×⅝" * ⅜"×¾" * ¼"×½"
KHRP26A22T

BS 5 Salon
BSQ250AV1 FXNQ40MAVE
2,0m 2,0m
⅜"×⅝" ¼"×½"
KHRP26A22T

Salon
FXNQ40MAVE
3,0m 2,0m
⅜"×⅝" ¼"×½"
KHRP26A22T

Salon
FXNQ50MAVE
3,0m
¼"×½"

Salon
FXNQ40MAVE

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 7
4.2. Piping Libertad
Libertad
REYQ18TY1

25,0m [6] 7,0m


⅝"×1⅛"×⅞" ¼"×½"
KHRP25A72T +
KHRP25M72TP
Server
FXAQ20AVM
2,0m 1,0m
⅝"×1⅛"×⅞" ⅜"×⅞"×¾" BS 6
KHRP25A72T +BS4Q14AV1 2,0m
KHRP25M72TP ⅜"×⅝" *

Central
FXMQ80PVE
6,0m 2,0m
⅜"×⅝" * ¼"×½"
KHRP26A22T

Sala reuniones
FXNQ32MAVE
4,0m
¼"×½"

Sala reuniones
FXNQ32MAVE
10,0m 2,0m
⅜"×⅝" * ¼"×½"
KHRP26A22T

Sala priv
FXNQ32MAVE
5,0m
¼"×½"

Sala priv
FXNQ32MAVE

14,0m 1,0m 1,0m 2,0m


½"×1⅛"×¾" ⅜"×⅝"×½" ⅜"×⅝" ¼"×½"
KHRP25A72T + KHRP26A22T
KHRP25M72TP
BS 7 Salon
BSQ160AV1 FXNQ32MAVE
3,0m 2,0m
⅜"×⅝" ¼"×½"
KHRP26A22T

Salon
FXNQ32MAVE
2,0m 2,0m
⅜"×⅝" ¼"×½"
KHRP26A22T

Salon
FXNQ32MAVE
4,0m
¼"×½"

Salon
FXNQ40MAVE
15,0m 1,0m 2,0m
⅜"×¾"×⅝" * ⅜"×¾" * ¼"×½"
KHRP26A22T

BS 8 Salon
BSQ250AV1 FXNQ40MAVE
2,0m 2,0m
⅜"×⅝" ¼"×½"
KHRP26A22T

Salon
FXNQ40MAVE
2,0m 2,0m
⅜"×⅝" ¼"×½"
KHRP26A22T

Salon
FXNQ40MAVE
4,0m
¼"×½"

Salon
FXNQ50MAVE

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 8
5. Wiring Diagrams
P1P2 = Please select the cable type and size in accordance with the databook.
F1F2 = Please select the cable type and size in accordance with the databook.

5.1. Wiring Cerrito


P1,P2
Cerrito Server BRC1E63
REYQ18TY1 FXAQ20AVM
IN F1,F2 F1,F2
L1,L2,L3,N 36A 3ph L,N 0,6A 1ph
L,N 0,4A 1ph

P1,P2
Central BRC1E63
FXMQ80PVE
IN F1,F2 F1,F2
OUT F1,F2 L,N 2,3A 1ph
BS F1,F2 P1,P2
Privado Director BRC1E63
FXNQ32MAVE
BS 3 IN F1,F2 F1,F2
BS4Q14AV1 L,N 0,6A 1ph
P1,P2
Office BRC1E63
FXNQ40MAVE
IN F1,F2 F1,F2
L,N 0,6A 1ph
P1,P2
Privado Contador BRC1E63
FXNQ25MAVE
IN F1,F2 F1,F2
L,N 0,3A 1ph
P1,P2
Privado Contador BRC1E63
FXNQ32MAVE
F1,F2
L,N 0,6A 1ph
L,N 0,1A 1ph P1,P2
BS 4 Salon BRC1E63
BSQ160AV1 FXNQ32MAVE
OUT F1,F2 IN F1,F2 F1,F2
L,N 0,6A 1ph
P1,P2
Salon BRC1E63
FXNQ32MAVE
F1,F2
L,N 0,6A 1ph
P1,P2
Salon BRC1E63
FXNQ32MAVE
F1,F2
L,N 0,6A 1ph
P1,P2
Salon BRC1E63
FXNQ40MAVE
F1,F2
L,N 0,6A 1ph
L,N 0,1A 1ph P1,P2
BS 5 Salon BRC1E63
BSQ250AV1 FXNQ40MAVE
OUT F1,F2 IN F1,F2 F1,F2
L,N 0,6A 1ph
P1,P2
Salon BRC1E63
FXNQ40MAVE
F1,F2
L,N 0,6A 1ph
P1,P2
Salon BRC1E63
FXNQ50MAVE
F1,F2
L,N 0,6A 1ph
P1,P2
Salon BRC1E63
FXNQ40MAVE
F1,F2
L,N 0,6A 1ph

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 9
5.2. Wiring Libertad
P1,P2
Libertad Server BRC1E63
REYQ18TY1 FXAQ20AVM
IN F1,F2 F1,F2
L1,L2,L3,N 36A 3ph L,N 0,6A 1ph
L,N 0,4A 1ph

P1,P2
Central BRC1E63
FXMQ80PVE
IN F1,F2 F1,F2
OUT F1,F2 L,N 2,3A 1ph
BS F1,F2 P1,P2
Sala reuniones BRC1E63
FXNQ32MAVE
IN F1,F2 F1,F2
L,N 0,6A 1ph
P1,P2
Sala reuniones BRC1E63
FXNQ32MAVE
BS 6 F1,F2
BS4Q14AV1 L,N 0,6A 1ph
P1,P2
Sala priv BRC1E63
FXNQ32MAVE
IN F1,F2 F1,F2
L,N 0,6A 1ph
P1,P2
Sala priv BRC1E63
FXNQ32MAVE
F1,F2
L,N 0,6A 1ph

L,N 0,1A 1ph P1,P2


BS 7 Salon BRC1E63
BSQ160AV1 FXNQ32MAVE
OUT F1,F2 IN F1,F2 F1,F2
L,N 0,6A 1ph
P1,P2
Salon BRC1E63
FXNQ32MAVE
F1,F2
L,N 0,6A 1ph
P1,P2
Salon BRC1E63
FXNQ32MAVE
F1,F2
L,N 0,6A 1ph
P1,P2
Salon BRC1E63
FXNQ40MAVE
F1,F2
L,N 0,6A 1ph
L,N 0,1A 1ph P1,P2
BS 8 Salon BRC1E63
BSQ250AV1 FXNQ40MAVE
OUT F1,F2 IN F1,F2 F1,F2
L,N 0,6A 1ph
P1,P2
Salon BRC1E63
FXNQ40MAVE
F1,F2
L,N 0,6A 1ph
P1,P2
Salon BRC1E63
FXNQ40MAVE
F1,F2
L,N 0,6A 1ph
P1,P2
Salon BRC1E63
FXNQ50MAVE
F1,F2
L,N 0,6A 1ph

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 10
6. Device Options
6.1. BS-Box Options
Model Description Used by
KHFP26A100C Closed pipe kit BS 6 [BS4Q14AV1]

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 11