ELEMENT Al As B Bi C Ca Ce Co Cr Cu Mg Mn Mo N Nb
Typical
1.1 2.4 0.3 4.1 6.9 0.4 6.0 1.2 1.6 0.6 2.8 1.2 1.7 3.5 2.6
DL [ppm]
ARL 3460 Metal Analyzer déf.
Guaranteed
≤ 2.2 ≤ 6.2 ≤ 0.9 ≤ 8.3 ≤ 12 ≤ 1.5 ≤ 11 ≤ 2.0 ≤ 4.0 ≤ 1.8 ≤ 5.6 ≤ 2.0 ≤ 3.9 ≤ 6.9 ≤ 5.0
DL [ppm]
Level [%] SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD
0.001 0.00006 0.00015 0.00002 0.00018 0.00023 0.00007 0.00025 0.00005 0.00015 0.00006 0.0001 0.00005 0.0002 0.0003 0.00013
15.3.2001
0.002 0.00009 0.00015 0.00004 0.00026 0.00023 0.00014 0.00025 0.00005 0.00015 0.00007 0.0001 0.00005 0.0002 0.0003 0.00016
0.005 0.00016 0.00015 0.00012 0.00042 0.00023 0.00033 0.00025 0.00005 0.00015 0.00009 0.00025 0.00005 0.0002 0.00045 0.00022
17:16
0.01 0.00025 0.00020 0.00038 0.00062 0.00023 0.00065 0.00030 0.00010 0.0002 0.00012 0.0005 0.00008 0.0003 0.0006 0.00035
0.02 0.00038 0.00025 0.0010 0.00085 0.0003 0.0013 0.00050 0.00015 0.0003 0.00018 0.0009 0.00015 0.0006 0.0008 0.0005
0.05 0.0007 0.00035 0.0006 0.0013 0.0004 0.0005 0.0003 0.0022 0.00032 0.0010 0.0013 0.0010
Page 5
0.1 0.0012 0.00050 0.0010 0.0007 0.0008 0.0006 0.0043 0.0006 0.0015 0.0018 0.0015
0.2 0.0020 0.0020 0.0015 0.0012 0.0012 0.0080 0.0011 0.0020 0.0025 0.0025
0.3 0.0030 0.0025 0.0020 0.0015 0.0020 0.0026 0.0030 0.0031 0.0048
0.5 0.0050 0.0037 0.0030 0.0020 0.0035 0.0048 0.0050 0.009
1. 0.008 0.0062 0.0060 0.0035 0.0065 0.0091 0.008 0.017
2. 0.010 0.010 0.0050 0.010 0.0135 0.010 0.030
3. 0.015 0.015 0.007 0.015 0.017 0.012
4. 0.020 0.020 0.008 0.020 0.021 0.015
5. 0.025 0.010 0.025 0.039 0.025
10. 0.05 0.015 0.065 0.040
20. 0.025
30. 0.035
40. 0.045
Remarks: This data applies when homogeneous samples are prepared by recommended sample preparation methods.
The precision given is typical performance. Guaranteed values will be 1.5 times higher.
For multibase instruments, some analytical performance may vary based on the analytical line selected.
Values in brackets for detection limits can be obtained by using the most sensitive lines, or a longer analysis time.
Guaranteed DLs are calculated at 95% confidence limit.
ARL 3460 - TYPICAL DETECTION LIMITS (3 sigma) AND PRECISION VALUES (1 sigma) FOR IRON BASE
ELEMENT Ni P Pb S Sb Si Sn Ta Te Ti V W Zn Zr
Typical
1.8 2.0 3.3 1.5 8.5 3.6 1.8 16 4.3 0.7 1.4 9.0 3.0 1.7
DL [ppm]
ARL 3460 Metal Analyzer déf.
Guaranteed
≤ 5.1 ≤ 4.2 ≤ 5.7 ≤ 3.0 ≤ 23 ≤ 8.4 ≤ 3.5 ≤ 32 ≤ 22 ≤ 1.0 ≤ 2.0 ≤ 20 ≤ 5.0 ≤ 3.3
DL [ppm]
Level [%] SD SD SD SD SD SD SD SD SD SD SD SD SD SD
0.001 0.00015 0.00008 0.00017 0.00009 0.00025 0.00015 0.0001 0.0006 0.00015 0.00003 0.00007 0.00045 0.0002 0.00012
15.3.2001
0.002 0.00015 0.00009 0.00020 0.00014 0.00025 0.00015 0.0001 0.0006 0.00025 0.00005 0.00007 0.00045 0.00025 0.00012
0.005 0.00015 0.00010 0.00035 0.00028 0.00027 0.00015 0.0001 0.00075 0.0004 0.00012 0.00007 0.00050 0.0003 0.00013
17:16
0.01 0.00015 0.00013 0.0007 0.00050 0.00033 0.00020 0.00015 0.0010 0.0007 0.00022 0.0001 0.00050 0.00035 0.0003
0.02 0.00016 0.00026 0.0014 0.0009 0.00046 0.00025 0.00025 0.0015 0.0005 0.0002 0.00055 0.00038 0.0006
0.05 0.0003 0.0006 0.0035 0.0020 0.0010 0.00030 0.00040 0.0025 0.0010 0.0005 0.00065 0.00042 0.0015
Page 6
0.1 0.0005 0.0016 0.007 0.0040 0.0022 0.0007 0.00065 0.0035 0.0020 0.0008 0.00085 0.0052
0.2 0.0009 0.0033 0.014 0.0075 0.0012 0.0030 0.0015 0.0015 0.021
0.3 0.0013 0.005 0.021 0.012 0.0018 0.0050 0.0020 0.002 0.046
0.5 0.0020 0.009 0.0028 0.010 0.0030 0.003 0.10
1. 0.004 0.019 0.0053 0.020 0.006 0.005
2. 0.007 0.010 0.011 0.010
3. 0.011 0.015 0.015 0.015
4. 0.013 0.02 0.020 0.020
5. 0.016 0.025 0.025
10. 0.035 0.045
20. 0.065 0.09
30. 0.10 0.15
40. 0.13
Remarks: This data applies when homogeneous samples are prepared by recommended sample preparation methods.
The precision given is typical performance. Guaranteed values will be 1.5 times higher.
For multibase instruments, some analytical performance may vary based on the analytical line selected.
Values in brackets for detection limits can be obtained by using the most sensitive lines, or a longer analysis time.
Guaranteed DLs are calculated at 95% confidence limit.
ARL 3460 Metal Analyzer déf. 15.3.2001 17:16 Page 1
Accuracy Stability
Precision is only a small part of providing accurate Stability of the instrument is of the utmost importance
analyses. The most important factor is the accuracy when doing routine analysis. Typical mid-term stability
and quality of the calibration standards. Next is the measured over 24 hours shows that the standard
development of the calibration curve relative to a deviation achieved is below two times the precision
specific analytical task. Matrix matching and high value, which is excellent.
energy pre-burn reduce or eliminate matrix effects,
and spectral interferences are significantly reduced by The example below shows the long term stability of
applying appropriate corrections. two elements recorded over a period of more than 15
days without any intermediate drift correction. The
The example shown below illustrates the significant values almost never went outside the control limits.
improvement with the CARL calibration.
Moving Average Chart: C%
0.0200
0.0180
0.0160
0.0140
0.0120
0.0300
0.0280
0.0270
0.0260
0.0250
Performance guarantee
Thermo ARL guarantees the precision shown in the
attached tables using homogeneous samples and
recommended sample preparation
Thermo ARL
ARL Applied Research Laboratories S.A.
En Vallaire Ouest C, case postale, CH-1024 Ecublens, Switzerland
Tel. ++41-(0)21-694 71 11, Fax ++41-(0)21-694 71 12
e-mail: marketing@thermoarl.com - www.thermoarl.com
The descriptions contained herein were correct at the time of printing and
are subject to alteration without notice. All orders are accepted subject to
our current conditions of sale, copies of wich are available on request.
© Thermo ARL-CH publication OE-05-941-1100-CH-e