Professional Documents
Culture Documents
45981
Sealed Lead-Acid Battery
Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction
allows safe operation in any position. Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified.
UB121100
U.L. recognized under file number MH 20567.
Maintenance-Free
Specification
Nominal Voltage 12 volts
Nominal Capacity 77º F (25º C)
20-hr. (5.50A) 110.0 Ah
10-hr. (10.23A) 102.3 Ah
5-hr. (18.70A) 93.5 Ah
1-hr. (66.00A) 66.0 Ah
Approximate Weight 65.7 lbs (29.8 kgs)
Internal Resistance (approx.) 5m
Shelf Life (% of normal capacity at 77º F (25º C))
3 Months 6 Months 12 Months
91% 82% 64%
Temperature Dependancy of Capacity (20 hour rate)
104 F (40 C) 77 F (25 C) 32 F (0 C) 5 F (-15 C) Charge Method (Constant Voltage)
102% 100% 85% 65% Cycle Use (Repeating Use)
AGM Operational Temperature Initial Current 33 A or smaller
Charge 32 F to 104 F (0 C to 40 C) Control Voltage 14.6 - 14.8 V
Discharge 5 F to 113 F (-15 C to 45 C) Float Use
AGM Storage Temperature 5 F to 104 F (-15 C to 40 C) Control Voltage 13.6 - 13.8 V
488 S. Royal Lane Coppell, Texas 75019 P 469.892.1122 T 866.892.1122 F 469.892.1123 sales@upgi.com
D1221-1
UPG No. 45981
UB121100
Maintenance-Free
Battery Charging Characteristics for Standby Use Battery Charging Characteristics for Cyclic Use
Charge volume
1 Discharge
1 Discharge 100 % (0.1CA*10h)
100 % (0.1CA*10h) -- 50 % (0.1CA*5h)
--50 % (0.1CA*5h) 2 Constant voltage charging
2 Constant voltage charging Charge voltage : 2.45V/cell
Charge voltage : 2.275V/cell Charge current : 0.3CA
Charge current : 0.1CA 3 Temperature : 25 (77 )
3 Temperature : 25 (77 )
Charge current
Charge current
www.upgi.com
488 S. Royal Lane Coppell, Texas 75019 P 469.892.1122 T 866.892.1122 F 469.892.1123 sales@upgi.com