You are on page 1of 2
VALVULA 7700 VALVE Para instalar en techo o pared /To install on wall or ceiling 2231 2250 2251 Flo 084s Flo.0801 Fi9 0093, Flo 0096 Paced ‘al echo Calog Paced ‘al echo celing Deseripion ‘Boson con resitnca with heating cord Con resistencia \withnesting cord Sin resstencla ‘without heating cord Sin resistencia ‘without heating card 29 Kgs. 28 Kgs. 17 Kgs. 1.6 Kgs. \Valvula destinada a equilbrar presiones mediante un paso de ale, a través dela misma, entre el interiory exterior de una cémara figorifica Estas diferencias de presién que corregimos meciante esta valvula, ‘se producen normalmente por las siguientes causas a modo de empleo: ~ Puesta en marcha de los elementos de desescarche en los evaporadores. - Por una fuerte entrada de mercancia en el seno de a cimara. - Por una prolongada apertura de las puertas. Por cambios de presiones atmosféricas exteriores ajenas ala cémara, yy que provocan también los mismos inconvenientes. Deseripeién: 1.Gaja exterior en aluminio fundido, 2.Tapa en poliestireno antichoque con refila de proteccién. 43. Rejla de proteccién inoxidable. 4.Pletina de aluminio anodizado con junta de estanqueldad, 6. Membranas méviles en aluminio anodizado provistas de otra ‘membrana en Neopreno para asegurar una absoluta estanqueldad, 7. Resortes en acero inoxidable que mantienen las membranas cerradas ‘por debajo de 10 mm. presién columna de agua, 8. Tubo de fibrocemento pasante, en el interior del cual se alojaré la cafia calefactora 9. Juntas de estanqueldad. 10, aria calefactora 25 W-220V con tomade tiera 11,Cajade conexion Formula de aplicacién: 13 T(273 +t) Num, de valvulas Volumen fariacion de temperatura x minutos x°C -=Temperatura en elinterior dela camaraoC 273y 13 =Constantes Ejemplo: Volumen =5,000m3 T=15 minutos para 1°C 30°C AB1S.000— £500. = 1 Ze vélvula—>2 vilvulas 15(273-30) 3685, above data are exactly observed, the two valves willensure that an, evenly distributed pressure of 30 kg/m2 isnot exceed. sta cura si estbleida desouts dls ensovosefctuados sabe la vavula 2200 “iocagtam Noreen Grn ipon tebe tests cog out th vove 200, ‘CAUDAL DEUNA VALVULA EN FUNCION DE DIFERENTES PRESIONES eee FLOW OF VALVE IV RELATION TO PRESSURES Fw 200) 175 150] 125 100] 8 25| ease The walls of cold room are constantly subjected to strains caused by pressure variations ether from inside or from outside. Inorder to contro said pressures, Valve 2200 has been created in order ta balance internal and extemal pressures through venting. Internal pressures Defrosting of evaporators loading of goods, extended opening of doors ‘entail warming up ofthe ai, hence overpressure risk of violent opening ‘ofthe doors or yielding of the walls. Likewise Cooling down oftheairand ‘consequently of the room, will result in underpressure and possibilty collapse ofthe walls. Forexample se or fall of temperature by 1 degree C. creates a pressure of ‘about 40 mm. water column i.e 40Kg/m2: fora 100m2 ceiling, an evenly distributed load of metric tons. ‘External pressures ‘Another foctor has tobe considered : atmospheric pressure. ‘Changes in weather (e.g. storms ) may cause pressure variations acting on the outside of walls withthe same drawbacks as internal pressures Description of Valve 2200: Itisaheating , mechanically operated valve, with two water tight mobile flaps, ‘one for admission and the other for exhaust. itis adjustable to operate over a given pressures ofabout 10 mm. water column. Itconsists in two elements: ‘A.Mechanical element, outside the room. tis composed: +1 Case made of aluminium light alloy epoxy coated (1) +1 gear case (2) made of polyestyrene, equipped with stainless protective gid T Anodized dura plate (4) with gasket (5) = 2Mobile flaps (6) consisting n anodized plates between wich a neoprene diaphragm is placed to ensure tightness. 2 stainless springs (7) hold the two flapsin closed position as long asthe press does not exceed 10 mm, water column. 1 Mibro-ciment tube 8 with gasket (9) oes through the wallsansis, ‘attached tothe case 1) bya tight fixture Heating element fixed inside the tube with a tightening band. It prevents frostin ‘and consist in: A25 W. heating od (10), 220 supply with round connection. 1 Tight connecting box (11), attached to the heating rod, The following formula determines the number of valve needed fora given case. ‘Num. of valves: 13¥. T(273 +0) V=Volumen ofthe room T= Time variation in min. for 1°C t= Temperature oftheroomin °C 23813 ‘onstant values 135.000 6500 15(273-30) 3645 178 valve —> 2valves 0 1020S

You might also like