You are on page 1of 16
Impulse Voltage Test System == ay D> usc Voltage Test System ‘2400KV 260k4 Impulse Votage Test System Brief Introduction CIDY series impulse voltage test system simulates lightening impulse, lightening chopping impulse and switching impulse voltage waveforms with a wide range of voltage and energy, to test on high voltage power units. In coordination of steep wave device the system can test on insulators or insulator strings. The impulse voltage test system can be used as impulse current test system with a little changes, to test on surge arrestors for residual voltage test. The system can not only be used in industry, but also in research and training, The impulse voltage ranges from 100KV to 7200kV Applications ‘System can be used to test: power transformers cables arresters (impulse current test) generators, motors insulators bushings instrument transformers capacitors cther insulation materials scientific research and education Petes peers eens figuration, to satis eee ere rol system, user friendly operation interface Bei canbe used in combination with AC or DC test system ‘System is composed by impulse voltage generator, charging unit, damping voltage divider, chopping device, steep ‘wave device, control and measurement system, wave-shaping units and isolating impedance. ‘The impulse voltage generator is parallel charged through the charging unit. Trigger the ignition device, and all sphere gaps of the generator are triggered in synchronization and discharge in series. The voltage goes through divider and is displayed on control screen. ommuniatongonssauement 2 ehaging uit Sstecpwave device Beltngineedance 11 conta syst 3 mul vine generator vole dider—Seambiation tet stam 12. masrroment te "Note:4. tem 8 & 9 only for combined test on switchgears or cables. 2.Diferent color e used for etterent testing requirements. Green ones are the base standard configuration, System Components Options controlled silicon voltage regulation unit resistors for special wave shaping charging unit Owave-shaping resistors and inductors for impulse voltage generator ‘esidual voltage measurement of arestors chopping device (for transformer test) other wave-shaping elements steep wave device (for insulator test) air cushion, wheels for base voltage divider other parts may needed control system ‘measurement system Technical Specifications Waveforms : Standard lighting impulse: 1.2230%/50#20%US, surge at peak < 5%; Standard switching impuls 250820%/2500:60%4S Front time of lighting impulke wave <15uS ‘Min output voltage: 210%Un Charging voltage instability: <£1% Synchronization range: 220% Syiichtonous discharge malfunction: <2% Ignition range: 10%~ 100% Running tim discontinuous running (charge and discharge every 300s) when 270%Un, continuous running (charge and discharge every 120s) when <70% Un Efficiency of generator: lightening wave (no-load) 290 % 2~5us CJDY-E ‘Type E generator uses single insulating tube to prop the generator, suspended with two single-bushing capacitors. Stage voltage is 100KV. The generator is composed by capacitors, front-wave and tail-wave resistors and discharge gaps. The discharge gaps are housed in insulating tube with ventilation. Clean and dry air keeps flowing through the gaps to improve the synchronous performance even under heavy conditions. The generator and charging unit are fixed on separate moveable bases connected with corona-free wires. Loon) come 75/500 os as Ts 1600 COVEISO sos 1 033s 0 =uoR ao oovez25/300 as oso as 1960 cove 1740 os om 200 vez 004 2 020 20 am 210 | 1% ove 3140 as 0350 nm cove. 15/600 05 ons as 2200 COVES sms 1 ous 30 20 (ERD 1500 croves/600 0 fA 02 425002000 20 ‘cove 21800 as cos 0 200 coecy0 omg 1 om xo 0 (Cove e200 as ons 6 3500 covez500 os cass 200 CoNEASSOO 9m 8 a an oo a 0 coves smn as oss Py ‘core s0200 0s eons 30 400 Coreen 1am a 1 oss so so 40300 ‘core san200 as om 9 eo CJDY-G ‘Type G generator uses insulating tube to prop double-bushing capacitors. Stage voltage is 100kV. The generator is. ‘composed by capacitors, front-wave and tail-wave resistors and discharge gaps. All wave-shaping units are bt while the discharge gaps are exposed, The generator and charging unit are fixed on separate moveable bases. Type G generator is suitable for relative low voltage and low capacity loading objects. “o0N6-75/800| as ower 78 1590 Coreasam 303 1 om as a a) 1016225730 as 05 as 160 ‘pre 0/00 os ous 10 m0 ciovezae og ¥ 02 200 a0) ‘ore 700 a 037550 180 copieasrec0 as 083s as 2000 ciovesorcn emg 1 owsr 30 somo 801500 core-sc0 100 1s 02545 1mm 1680 zm ‘ove eco os Doses 0 2470 ‘oprGa00 ew 1 0225 se 28505 2m cioie-a ‘oo soso seo 2100 20 so ‘00 30 Dor soan00 0 ‘eo ou 4 ‘DoFs0y00 2600 00700 3000 000 00 e100 700 oF 20ma00 1400 7005 21900700 DoF s0240 240, 00 00 5 ‘oro DoF 043000 300 ‘co 5000 10205 21m 100 ‘oF 30360 3600 1855 2390050 or aovooo oo ‘co. ‘ooo ass e201 ‘DoF s0A0 ao 675 250) asso Dor soon 00 7100 7200 0800 500 1800 005300720 790 50 00 23500 ‘oea00 200 Chopping device ‘chops lightening impulse front wave or tail wave, Gap distance is adjusted via motor controlled by operation device. Trigger signals are isolated by optical fiber, Delay is realized by hardware together with software. = ‘pai8.300 00 3 1080 a8-100 = ‘ mo pgi.con 0 6 0 1300 atcoaaTAN 5-20 oo 5 mf ‘ogi.soo soo 8 sss 0 que 120 6 say a io Qs-160 100 8 00 00200 aie 800 1200 ° woo mito pQ82400 200 2 20 ao 20 ae-3o00 00 5 cre) ‘ogi 3500 seco 6 ose 98-100 ‘co 2 ie tam a-4e00 0 ES seas DB-Series Steep Wave Test Device ARETE vit neering se a vin nd lage cides Th scr See RTT eT veringcapactor spies gopceciea vs and fee By adjusting charging vologe el the genrtr ara regubtiogdstnceof he sleep wave sphere gap, the users abies conc font une of muse woage The sepeing capectoris able thstandectage of 60H, with expactane of 30pF The spec oup satan fr steopee tester pole ltrs deur The forme test reques eopbes es then 150040 whe te alert ques a max steps of 2500-40000 Fue Resistive voltage divider takes advantage of small dimension and low impedance in order to get fast response. The divider is oilimmersed. Same as steep wave sphere gap, the resistive voltage divider is also fixed on moveable base. ‘Specifications as below: Sid potmerinuision 560 Appoe2Stohn AperouORotm Taslins ODS BH

You might also like