RAPT 6.3.18.

0 4/19/2017 5:38:33 PM Page 24/25


Licensee: DP Architects Sdn Bhd Frame Description: HGI GL1b License No.: 106470631800114WPN1
Design Comments:-
- - Column Grid 3 - Required Bar Size is smaller than the Preferred Bar Size. Maintaining the same cover will require slightly less reinforcement
than calculated.
- - Column Grid 4 - Required Bar Size is smaller than the Preferred Bar Size. Maintaining the same cover will require slightly less reinforcement
than calculated.
- - Span 3 - Required Bar Size is greater than the Preferred Bar Size. Maintaining the same cover will require slightly more reinforcement than
calculated. RAPT has increased the required reinforcement by the ratio of the effective depths for the 2 bar sizes in the reinforcement layout.

Span 4
Top Reinforcement Bottom Reinforcement

Max Section Max Section


Locat Space Area Depth Width Rebar Reqd Space Area Depth Width Rebar Reqd
mm mm mm2 mm mm A mm mm2 mm mm A
1 300 0 52.5 1964 No Steel Added 0 3167.91 557.5 380 4 T32 @ 86.3
163 300 0 52.5 1964 No Steel Added 0 3167.91 557.5 380 4 T32 @ 86.3
325 300 0 52.5 1964 No Steel Added 0 1394.8 557.5 380 2 T32 @ 259
488 300 0 52.5 1964 No Steel Added 0 447.2 557.5 380 1 T32 @ 999
609 300 0 52.5 1964 No Steel Added 0 0 557.5 380 No Steel Added
611 300 0 52.5 1964 No Steel Added 0 0 557.5 380 No Steel Added
800 300 0 52.5 1964 No Steel Added 0 0 557.5 380 No Steel Added
990 300 0 52.5 1964 No Steel Added 0 0 557.5 380 No Steel Added
1320 300 0 52.5 1964 No Steel Added 0 0 557.5 380 No Steel Added
1650 300 0 52.5 1964 No Steel Added 0 0 557.5 380 No Steel Added
1980 300 0 52.5 1964 No Steel Added 0 0 557.5 380 No Steel Added
2310 300 0 52.5 1964 No Steel Added 0 0 557.5 380 No Steel Added
2640 300 0 52.5 1964 No Steel Added 0 0 557.5 380 No Steel Added
2970 300 0 52.5 1964 No Steel Added 0 0 557.5 380 No Steel Added
3349 300 0 52.5 1964 No Steel Added 0 0 557.5 380 No Steel Added
3351 300 0 52.5 1964 No Steel Added 0 0 557.5 380 No Steel Added
3606 300 0 52.5 1964 No Steel Added 0 1226.21 557.5 380 2 T32 @ 259
3860 0 0 52.5 1964 No Steel Added 0 2124.86 557.5 380 3 T32 @ 129.5
Shear Reinforcement
Spacing of Sets
2 legs 2 legs 2 legs Shear
Area T8 T10 T12 Comments
mm2/mm mm mm mm A
0.43 236 368.2 418.1 Minimum Steel
0.43 236 368.2 418.1 Minimum Steel
0.43 236 368.2 418.1 Minimum Steel
0.43 236 368.2 418.1 Minimum Steel
0.43 236 368.2 418.1 Minimum Steel
0.43 236 368.2 418.1 Minimum Steel
0.43 236 368.2 418.1 Minimum Steel
0.43 236 368.2 418.1 Minimum Steel
0.43 236 368.2 418.1 Minimum Steel
0.43 236 368.2 418.1 Minimum Steel
0.43 236 368.2 418.1 Minimum Steel
0.43 236 368.2 418.1 Minimum Steel
0.43 236 368.2 418.1 Minimum Steel
0.43 236 368.2 418.1 Minimum Steel
0.43 236 368.2 418.1 Minimum Steel
0.43 236 368.2 418.1 Minimum Steel
0.43 236 368.2 418.1 Minimum Steel
0.43 236 368.2 418.1 Minimum Steel

Design Comments:-
- - Column Grid 4 - Required Bar Size is smaller than the Preferred Bar Size. Maintaining the same cover will require slightly less reinforcement
than calculated.
- - Span 4 - Required Bar Size is greater than the Preferred Bar Size. Maintaining the same cover will require slightly more reinforcement than
calculated. RAPT has increased the required reinforcement by the ratio of the effective depths for the 2 bar sizes in the reinforcement layout.