DM@IAL MAMrorss RL OT SUF WK-6889 DIGITAL GAUGE INTRODUCTION SZ8H" WK-6889 digital manifold adopt intelligent computer chips, high accuracy pressure & temperature sensors. High resolution LCD can show actual temperature, sub cooling, superheat, vacuum. They are programmed with 88 refrigerant pressure and saturated temperature data taken from the latest NIST database which can measure sub cooling and superheat accurately and help you: analysis usage amount of refrigerants. THANKS FOR USING OUR PRODUCTS! Features & Switch between refrigerant pressure and vacuum. % Programmed with 88 refrigerant pressure and saturated temperature data taken from the latest NIST database & Measuring Vacuum and shown in percentage. & Low battery indicator. Long battery life of 30 hours. + Show actual temperature, sub cooling, superheat, vacuum, + High resolution LCD with background lamp, Low voltage DC 8V design. * 2 way aluminum alloy manifold with diaphragm design. Sensors: 2 pressure sensors and 2 temperature sensors SPECIFICATION 1. Pressure units: KPA INHg , KgF/cm2, PSI, Bar 2. Vacuum units: Torr, mmHg, Micron, % 4, Power: 1.5V AAX 4= 6V 5, Pressure measuring: actual pressure. 6, Temperature units: °F, °C 7. Measuring range: Vacuum: -101 Kpa~0 Kpa Proof pressure: 0 MPa~ 6MPa Refrigerant pressure: 0 MPa~ 4MPa 8, Sensor resolution: 1 KPa 9. Sensor accuracy: 20.5% 10. Overload limit: 100Bar, 10Mpa 11, Operating temperature: -20°C~+60C 12, Battery life: 30 hours 13, Sensor temperature range: -50C-150C (-58F- 302F ) 14. Temperature accuracy: <50C (+-0.1C) ,>50-1006 (+/-0.26) , >100C (+/- 10) 16. Auto-off: 15 min with disabling capability. 1.OPERATION INSTRUCTION 1.KEYPAD FUNCTIONS Item|Keypad Function 1_| P%e)_| Turns the manifold onioff (eq) | Zero cut(use it after the manifold is turned on) Select pressure units Select refrigerant (scroll upward) ‘wich stuatedaculterpereue mode and sub oolnglupthaet mode | Select temperature units Select refrigerant (scroll downward) 7S\@) (W) | Vacuum mede 9 | {aw | LCD background lamp on/off WARNING: (236) press and hold this Key for 3 sec to zero out the reading only when the manifold is turned on and the reading is NOT zero. (DO NOT press this key when the manifold is start to work) 2.0PERATION INSTRUCTION @.Tum the manifold on/off: press key. (2).Zero out the reading: press “ ’ key to zero out the reading of pressure. 3).Select units: press key to select pressure units. Press* key to switch temperature units. / to select refrigerant For fast selection, press and hold the key. @.Background lamp: press * LAW ’ key to turn on/off the lamp. @.Select refrigerant: press @ Measuring Vacuum: press * key to enter into vacuum mode. @.Measuring temperature: when temperature sensors are connected, a actual temperature reading will be shown on LCD. If the sensors are disconnected, the reading will not be shown anymore, ®.When measuring temperature(temperature sensors attached), press ' *key to select display refrigerant temperature or sub cooling, superheat. 3 3.MANIFOLD DIAGRAM OVER COREFRIGERANTS NS TexTURE SOFT RUBHER EUTTON Camp tema tenrerae HIGH ACCURACY ‘TEXTURE DapeRcl SUPER SHOCK PROOF 4.LCD DISPLAY AB: “ABB: Low Side “BEB, <— kPa Torr inklg KgFief High Side, ABBE} PSI Bar mmHg Micron LCD display instruction S/N Function Low pressure actual temperature Saturated temperature or superheat Saturated temperature (low pressure) Select units Battery indication Refrigerant and vacuum percentage Vacuum indicate High pressure actual temperature Saturated temperature or sub cooling B\o\e|S|@lalsla|ale Saturated temperature (high pressure) VACUUM OPERATION AND CHARGING: 1,.VACUUM OPERATION IN REFRIGERATION SYSTEM 1.Press | key to turn the manifold,if necessary,press" key to turn background lamp on 2.Press " key to enter into vacuum mode Connect A/C system, eigital manifold and vacuum pump as shown below «Prove “[ZERO]” key to zero out the reaing on LED Aecoring fg ietng rol Jac pnd ater 2° nn af vam Seer Etat wn on LCD. Haher vercent mean nigher vacuum Caer eee eee aks. fhe reading on manifold Keep SHR ans ne akin steak NOTES faysttn preseure teasing 7Minen vacuum operation's Thished, dove the vales on manifold first and then close the vacuum pump. At last, press key to tum off the manifold ‘Vacuum operation diagram vy Vacuum pump 2.Refrigerant charging operation after vacuum operation: 1.As shown below, connect cylinder, A/G system and manifold, 2.Press" "key to turn the manifold on Press and hold’ {LAMP]" key to tum the background lamp on. 3.Press " or "key to choose a refrigerant which will be charged IMake sure you chase same refrigerant on bath low and high side cauges NOTE ress and hols" ]*or"[R]"key for fast selection 4 Press" "and" [We] "key to select pressure and temperature unit 5.Press key to zero out the reading 6.Open the valve on left of manifold (BLUE), open the valve on cylinder, then turn on the refrigeration system. T.Aiter refrigerant charging operation is finished, close the valve on cylinder 8. Open the valve on right of manifold (RED), test the system pressure S.If refrigeration system is work normally, close the both vaive on manifold (RED and BLUE) and then turn off the refrigeration, system. Press * * key to turn off the manifold. Refrigerant charging operation is finished Refrigerant charging operation diagram Cylinder and charging scale Refrigerant technical parameter 5.LCD display Following refrigerants:Liq=Liquid Vap=Vapor 4. vacuum measuring LCD display Unit Refrigerant Refrigerant [Unit Refrigerant Refrigerant Txt I 25 | RAOORIQ | RADAVAP 2) RS RL 4o_| RUBIO RIOTB VAP ao) Rie Ri ap ea Ra 4) Rus RLS ag | RUDALIQ | RLORVAP 3) Rite Re $8 RAIOB-LIQ | RAOB-VAP eR RD So] RaatIQ [Ria VAP as BLE SL] RALBLIQ | RAIB VAP aR RD St [RADA RIDAVAF 9) Ris RLS 33 | RIGALIO | RUSAVAP 1 Rw RL Si] Raa8 UO RIA VAP. a] RG RE 35_[RIMBLIQRINBVaP 2) RMA RIMA So RilsALIQ | RUSA VAP ee ia] Rie Ris 37] RELIG RUB VAP a) Rise LE 38 RiloA-LIQ | RU6A-VAP 2.Pressure measuring LCD display ( refrigerant temperature) 4 RLS aug 3_mileatig __Rhsacar 16] RUA RIA | RERALIQ—-RUSSA-VAP 17_|RIS2A RISA o1 | RNPALIQ RIVA VAF isto RID 2] Rusti) ROA VAP is Ra RE 3 RETALIQ | RAAVAP a) R218 B18 of | Ruwig | Rebar a) RD me 65 | RIDALIQ” | RO2VAP | RNEA | RTE oo RIB RII VAP Rs ay oF | RR2C-LIQ RDC Var 2 REA ROGER 6] RO2D-LI9 RUIDVaP a5) Rasca—_| RMSCA © | ROU | ROSAVAP 36) RFA RISA | RDEALIQ | REAVAP a RO 200, TL |RUsALIg | ROSAVAP ET m2 | R408 U1 | RDOAVAF 3.Pressure measuring LGD display (sub cooling & superheat) 29 RIALIQ | RvoAVaP [73 | RAZTALLIC RAQTA-VAP ‘Rie RvB Var || 74] Risa LIQ REA VAP SI) Rnic-tigRanie-vaP— || 75] a0 20 a2) Rima.tig | Rigza.var—||76 | asotig | RsoovaP 33 Rie LI RAB VAP] Rs0r LIQ RSOL VAP Si] Ritsa-LIg” |) Rigsa-var—|[7 | Rsm2-LIg | Rs02.VAP a5) Rise IG RWB ap ||| asus. Lig asus VAP So RASA-CIQ”Rabda-VAP— | 70] RS0e-L1Q—RSOFVAP 37) Rinsa Lig Rwsavar—|['si_|Rs07a. IQ |Rs07a VAP Rides Lig Rasa Var — || 82] Roos LIQ Rs0sa VAP 35 RAMALLIQ—-Ranva-vaP—||"g3[RSnR0-11Q | RoDaR-VAP 40 Ri0me 110 Rave Vap—||-s1_|Rs00a LIQ Rss VAP aI RITTCLQRaNIC-VaP—] 85] Ral Ret 42) RIDDLIQ | RavmD-VaP— || g5_| Ro RaD0x 45 Rue LIQ Rave VaP— |_| R7I7 RIT Ga RangALIQ—Ratsa-VaP—] [as R7ae Bu 9 10 Measuring actual sub cooling & superheat Superheat is the difference between the actual temperature (sensor temperature) of the refrigerant (gas) as it leaves the evaporator and the boling point temperature of the refigerant in the evaporator coil (saturated temperature). After boiling, the refrigerant continues to warm up. The number of degrees that ‘warmed up” after boiling 1s called the superheat. Under worst-case conditions (low load for fixed orifice systems), the refrigerant in the evaporator boils off near the end of the evaporator coil. To make sure liguid doesn't enter the compressor under the worst case condition, the AC manufacturers publish charts. The charts indicate what the supetheat should be at a gwen indoor wet bulb measurement and outdoor air temperature. Measuring supetheat is your best indication on a fixed ontice system of the proper refngerant charge and operating conditions. tt everything else is working properly and the actual superheat is too high, add refrigerant. it's too low, remove refngerant. Sub cooling isthe difference between the boling point of the refigerant in the condenser (saturated temperature) and the actual temperature (sensor temperature) of the refrigerant as it leaves the condenser The degrees that the refiigerant “cools down’ below the boiling point is the Sub-cooling. Under worst case scenano low load for thermostatic expansion valve systems (TXV) the sub cooling will continue to rise. If the sub cooling fises too high, liquid may be backed into the compressor causing damage and failure (On TXV systems, the subcooling is the best indication of the state of the charge in the retngerant system since these systems are designed to maintain constant superheat, Properly charging a system ensures maximum efficiency and longer equipment ite Ter TARGET SUPERHEAT AND SUBCOOLING Follow all equipment manufacturer's specifications, warnings and suggestions. To determine the target superheat (fixed orifice system) or sub cooling (charts vary dramatically from one system to another), you will typically need three things. Outdoor dry bulb (outdoor air temperature), indoor wet bulb, and the manufacturers target supetheat chart or sub cooling chart 12 GENERIC TARGET SUPERHEAT & SUBCOOLING CHARTS” "The required superheat chart is an example of a generic superheat chart of a typical fixed orifice, split residential system. The required sub cooling chart is an example of a typical chatt for a TXY, split residential system. These charts should not be used for charging. They are only examples to show what the manufacturer's charts may look like. Follow all manufacturer's indications, instructions and warnings above those in this manual REQUIRED SUB COOLING WET BULB TEMPERATURE ¥ a_|a elo le ae Shs [fo 9s cs Bh [so [seas as & Fa EC & [oo ye [as fae [asta Biss 18773530 3 [100 ahs fas hao hs 3 or Fo 2 io as ]i2 ao sf 8 Eas [io [s et REQUIRED SUPERHEAT WET BULB TEMPERATURE s0_[s2 [su [50 [58 [oo [oz [os [oo [os 7 set fe [it [a0 9s [36 [90 Ls 0 @ joe [7 a0 faa fas fas far fe a7 30 [33 38 Bs 6/10 [13 [36 18 [2 [28 36, = 7 (10 [33 i [19 [ar 33 Bos 68 [ase 3 = (0 ss fe fis 25 E iss sa 26 3 [0 s_ (8 2s Bs 5 22 = [100 20 & laos 7 0 rg us a The indoor wet bulb measurement should be taken as close to the evaporator coil inlet as possible. The outdoor dry bulb reading should be taken as close to the condenser air inlet as possible. 3 PARTS AND ACCESSORY 1.WK-6889 manifold:1 set 2. Red, yellow, blue charging hoses 1pes each. 3.Clamp thermal temperature sensors: 2 pes 4.4.5V AA alkaline batteries: 4 pes 5.INSTRUCTION MANUAL 6.Carrying case 1 pes

You might also like