Bulletin 71.

2:627F
February 2013

Type 627F Pilot-Operated Pressure


Reducing Regulator

W5607-1 W5641-1

Figure 1. Type 627F Pressure Reducing Regulators

Introduction pipeline. A two-bolt connection between the body


and diaphragm casing simplifies disassembly
The Type 627F pilot-operated (Type 6351F pilot) for maintenance.
pressure reducing regulator (Figure 1) provides   • Installation Adaptability—The diaphragm case
superior performance when used in pressure-factor and/or regulator body can be rotated in any of
measurement (fixed-factor billing) applications. The four positions to allow regulator installation in
Type 627F includes a factory-installed Type 6351F locations with limited space. The regulator may be
pilot and has external registration that requires a installed in any position without affecting operation
downstream control line. as long as the spring case vent is protected from
the elements.
Features  • T
 amper-Resistant—An adjusting screw locknut
and protective cap (Figure 2) is standard on all
 • A
 ccurate for Pressure-Factor Measurement Type 6351F pilots to discourage tampering with
Applications—Pilot action controls pressure to the pressure setting.
within ±1 percent of the absolute outlet pressure
 • W
 ide Range of Flow Capabilities—A selection of
(psia) setting at full valve disk travel, resulting in
body and orifice sizes is available to satisfy
higher capacity than could be obtained without
various flow requirements.
a pilot. This capability results in low-pressure
variations over broad flow ranges and inlet   • Tight Shutoff Capability—A flat-faced disk of
pressure ranges. Nitrile (NBR) provides excellent shutoff capability.
  • Easy to Maintain—Trim parts can be replaced
without removing the regulator body from the
D101544X012

www.fisherregulators.com
Bulletin 71.2:627F
Specifications

Body Sizes and End Connection Styles Construction Materials (continued)


Ductile iron: 3/4, 1, or 2 NPT Disk Assembly: Aluminum (standard) or
Steel: 3/4, 1, or 2 NPT; Stainless steel holder with Nitrile (NBR) disk
NPS 1 or 2 / DN 25 or 50, CL150 RF, O-Rings and Diaphragm: Nitrile (NBR)
CL300 RF, CL600 RF, PN 16/25/40 RF Tension Spring: Plated steel
Type 6351F Pilot
Maximum Inlet and Differential Pressures(1) Body: Stainless steel
See Table 2 Spring Case: Aluminum
Minimum Pressure Differential Diaphragm: Nylon fabric coated with Nitrile (NBR)
20 psid / 1.4 bar d Inner Valve Plug: Stainless steel/Nitrile (NBR) or
Stainless steel/Fluorocarbon (FKM)
Outlet Pressure Ranges(1) Stem: Stainless steel
5 to 100 psig / 0.34 to 6.9 bar Control Spring: Zinc-plated steel
See Table 1 Valve Spring: Stainless steel
Maximum Emergency Outlet Pressure(1) Pusher Post: Aluminum or Stainless steel
250 psig / 17.2 bar for all Type 627F actuators Diaphragm Plate, Lower Spring Guide, and
and Type 6351F pilot components. Adjusting Screw: Zinc-plated steel

Outlet Pressure Accuracy Temperature Capabilities(1)


±1% of absolute pressure setting(1) (psia or bar -20 to 180°F / -29 to 82°C
absolute) when inlet pressure is held within Pressure Registration
allowable variations shown in Table 3; droop does External through 1/4 NPT (internal) control
not exceed 1% of absolute pressure setting for line connection (see Figure 2)
flow rates shown in Tables 6 through 8.
Pilot Spring Case Vent Connection
Flow Coefficients 1/4 NPT (internal) with removable screened
See Table 4 vent assembly
IEC Sizing Coefficients Pilot Connections
See Table 5 1/4 NPT (internal)
Typical Regulating Capacities Approximate Weights
See Tables 6 through 8 and Capacity NPT body with Ductile Iron or Steel Casings:
Information section 10 pounds / 4.5 kg
Typical Performance Curve NPT body with Aluminum Casings:
See Figure 3 6.3 pounds / 2.9 kg
Flanged body with Steel Casings:
Construction Materials 18 pounds / 8.2 kg
Type 627F Main Regulator Flanged body with Ductile Iron Casings:
Body: Ductile iron (standard) or steel 14 pounds / 6.4 kg
Spring Case and Diaphragm Case: Die cast
Aluminum (standard), Ductile iron, or Steel External Dimensions
Orifice: Aluminum (standard) or Stainless steel See Figure 4

1. The pressure/temperature limits in this Bulletin and any applicable standard or code limitation should not be exceeded.

2
Bulletin 71.2:627F
FIELD INSTALLED
DOWNSTREAM
CONTROL LINE

SPRING SEAT BOLT,


THIS IS NOT AN
ADJUSTING SCREW

FILTER
(FACTORY
INSTALLATION RESTRICTION
OPTIONAL) (BLEED)

TENSION
SPRING

PILOT DIAPHRAGM
MAIN REGULATOR
DIAPHRAGM VALVE
DISK

PILOT ADJUSTING
SCREW

LEVER
TYPE 6351F PILOT

TYPE 627F REGULATOR

PILOT SUPPLY TUBING


(FACTORY INSTALLATION OPTIONAL)

A6558
INLET PRESSURE
OUTLET PRESSURE
ATMOSPHERIC PRESSURE
LOADING PRESSURE

Figure 2. Type 627F Pilot-Operated Pressure Reducing Regulator Operational Schematic

3
Bulletin 71.2:627F
Table 1. Outlet Pressure Ranges
PILOT CONTROL SPRING INFORMATION
OUTLET PRESSURE RANGE
PILOT TYPE Wire Diameter Free Length
Part Number Color Code
psig bar Inches mm Inches mm
5 to 35 0.34 to 2.4 1B788327022 Unpainted 0.142 3.61 2.13 54.1
6351F
35 to 100 2.4 to 6.9 1K748527022 Red 0.192 4.88 2.19 55.6

Table 2. Maximum Allowable Inlet Pressures and Pressure Differential

ORIFICE SIZE MAXIMUM INLET PRESSURE MAXIMUM PRESSURE DIFFERENTIAL


Inches mm psig bar psi bar
3/8 x 1/8 9.5 x 3.2 250 17.2 250 17.2
3/8 x 1/4 9.5 x 6.4 250 17.2 250 17.2
3/8 9.5 250 17.2 250 17.2
1/2 13 125 8.6 125 8.6

Table 3. Additional Specifications

ALLOWABLE INLET PRESSURE RANGE FOR MAINTAINING OUTLET PRESSURE WITHIN


ORIFICE SIZE ±1% OF THE ABSOLUTE OUTLET PRESSURE SETTING(1)
5 psig / 0.34 bar 30 psig / 2.1 bar 40 psig / 2.8 bar 60 psig / 4.1 bar 100 psig / 6.9 bar
Inches mm psig bar psig bar psig bar psig bar psig bar
3/8 x 1/8 9.5 x 3.2 30 to 250 2.1 to 17.2 55 to 250 3.8 to 17.2 65 to 250 4.5 to 17.2 85 to 250 5.9 to 17.2 125 to 250 8.6 to 17.2
3/8 x 1/4 9.5 x 6.4 30 to 250 2.1 to 17.2 55 to 250 3.8 to 17.2 65 to 250 4.5 to 17.2 85 to 250 5.9 to 17.2 125 to 250 8.6 to 17.2
3/8 9.5 30 to 250 2.1 to 17.2 55 to 250 3.8 to 17.2 65 to 250 4.5 to 17.2 85 to 250 5.9 to 17.2 125 to 250 8.6 to 17.2
1/2 13 25 to 125 1.7 to 8.6 50 to 125 3.4 to 8.6 60 to 125 4.1 to 8.6 80 to 125 5.5 to 8.6 120 to 125 8.3 to 8.6
1. For best performance, outlet pressure setting should be made using an inlet pressure that is midway between the highest and lowest expected inlet pressure.

Table 4. Flow Coefficients


3/4 NPT BODY NPS 1 / DN 25 BODY NPS 2 / DN 50 BODY
ORIFICE SIZE
Wide-Open Wide-Open Wide-Open Wide-Open Wide-Open Wide-Open
C1 C1 C1
Inches mm Cg Cv Cg Cv Cg Cv
3/8 x 1/8 9.5 x 3.2 12.5 0.43 29.1 12.5 0.43 29.4 12.5 0.43 29.2
3/8 x 1/4 9.5 x 6.4 50 1.63 30.6 50 1.71 29.3 52 1.66 31.3
3/8 9.5 108 2.99 36.1 108 3.42 31.6 115 3.39 33.9
1/2 13 190 4.87 39.0 190 5.29 35.9 200 5.01 39.9

Table 5. IEC Sizing Coefficients

ORIFICE SIZE XT
FD FL
Inches mm 3/4 NPT body NPS 1 / DN 25 body NPS 2 / DN 50 body
1/8 3.2 0.54 0.55 0.54 0.79
1/4 6.4 0.59 0.54 0.62 0.87
0.50
3/8 9.5 0.82 0.63 0.73 0.89
1/2 13 0.96 0.82 1.01 0.86

4
Bulletin 71.2:627F
Principle Operation To avoid overpressure, provide appropriate pressure
relieving or pressure limiting devices to ensure that
The superior performance of a Type 627F regulator is none of the limits in the specifications section is
due to the amplifying effect of the pilot and the two-path exceeded. Regulator operation within ratings does
control system (Figure 2). Changes in outlet pressure not prevent the possibility of damage from external
act quickly on the main regulator diaphragm which sources such as debris in the pipeline. Inspect the
repositions the valve disk to provide fast response to regulator for damage after any overpressure condition.
system changes. Simultaneously, the pilot amplifies Refer to the relief sizing coefficients in the
system pressure changes to position the main specifications table and the Capacity Information
regulator valve disk for precise pressure control. section to determine the required external relief
Inlet pressure is used for the pilot supply pressure. valve capacity.
If downstream flow increases, lowering the outlet
pressure below the regulator setpoint, pressure on the
pilot diaphragm and the lever side of the main regulator
Capacity Information
diaphragm decreases. The pilot opens to supply the Natural gas regulating capacities at selected inlet
required loading pressure increase. The increased pressures and outlet pressure settings are given in
loading pressure from the pilot overcomes the main Tables 6 through 8. Flows are in SCFH (60°F and
regulator spring force, and the main regulator valve 14.7 psia) of 0.6 specific gravity natural gas. To
disk moves farther open to supply the required flow. determine the equivalent capacities for other gases,
When downstream pressure increases due to lowered multiply the table capacity by the following appropriate
demand, greater pressure is registered on the pilot conversion factor: 0.775 for air, 0.789 for nitrogen,
diaphragm and the lever side of the main regulator 0.625 for propane, or 0.548 for butane. For gases of
diaphragm. The pilot closes, and the excess loading other specific gravities, multiply the given capacity by
pressure bleeds off to downstream, through the pilot 0.775, and divide by the square root of the appropriate
restriction. With the lower loading pressure, the spring specific gravity.
can move the main regulator disk closer to the orifice.
Then, if capacity is desired in normal cubic meters
Under no flow conditions, the excess loading pressure per hour (Nm3/h) at 0°C and 1.01325 bar, multiply
bleeds through the pilot restriction to the downstream SCFH by 0.0268.
system until the loading pressure and outlet pressure
equalize. The main valve is closed by the spring and To determine wide-open flow capacities for relief sizing
the bleed stops. use the following formula:

Installation 520   3417 P


Q  = CgP1SIN DEG
The Type 627F regulators may be installed in any GT C1 P1
position, as long as flow will be in the same direction
as that indicated by the body arrow. These regulators where,
should be installed so that their spring case vents are
protected from anything that might clog them.  C1 = Cg/Cv (see Specifications table)
 Cg = Gas sizing coefficient (see Specifications table)
Emerson™ provides an instruction manual with
  G = Gas specific gravity (air = 1.0)
every regulator shipped. Refer to this for complete
 P1 = Valve inlet pressure, psia
installation, operation, and maintenance instructions.
  P = Pressure drop across valve, psi
Included is a complete listing of individual parts and
  Q = Gas flow rate, SCFH
recommended spare parts.
  T = Absolute temperature of gas at inlet, °Rankine

Overpressure Protection To obtain the published capacities, the inlet and outlet
piping should be the same as the regulator size.
Overpressurizing any portion of a regulator or associated
equipment may cause personal injury, leakage, or
property damage due to bursting of pressure-containing
parts or explosion of accumulated gas.

5
Bulletin 71.2:627F
Table 6. F
 low Capacities in SCFH / Nm3/h of 0.6 Specific Gravity Natural Gas at 1% Droop in Absolute Outlet Pressure for 3/4 NPT
(Downstream Control Line in Body Size Piping)
OUTLET 3/4 NPT BODY SIZE
PILOT SPRING RANGE, INLET
PRESSURE
PART NUMBER, AND PRESSURE Orifice Diameter, Inches / mm
SETTING
COLOR CODE
psig bar psig bar 3/8 x 1/8 / 9.5 x 3.2 3/8 x 1/4 / 9.5 x 6.4 3/8 / 9.5 1/2 / 13
30 2.1 700 18.8 2840 76.1 5780 155 9730 261
40 2.8 860 23.1 3500 93.8 7480 200 13,100 351
50 3.5 1020 27.3 4140 111 8850 237 15,400 413
60 4.1 1170 31.4 4780 128 10,200 273 15,500 415
80 5.5 1490 39.9 6060 162 12,900 346 15,500 415
5 0.34
100 6.9 1800 48.2 7340 197 15,000 415 15,500 415
125 8.6 2200 59.0 8940 240 15,500 415 15,500 415
150 10.3 2580 69.1 10,500 281 15,500 415
200 13.8 3370 90.3 13,700 367 15,500 415
250 17.2 4170 112 15,500 415 15,500 415
30 2.1 690 18.5 2760 74.0 5480 147 8500 228
40 2.8 860 23.1 3500 93.8 7480 200 13,100 351
50 3.5 1020 27.3 4140 111 8850 237 15,400 413
60 4.1 1170 31.4 4780 128 10,200 273 17,800 477
80 5.5 1490 39.9 6060 192 12,900 346 19,500 523
10 0.69
100 6.9 1800 48.2 7340 197 15,700 421 19,500 523
125 8.6 2200 59.0 8940 240 17,500 469 19,500 523
5 to 35 psig / 150 10.3 2580 69.1 10,500 281 19,500 523
0.34 to 2.4 bar 200 13.8 3370 90.3 13,700 367 19,500 523
1B788327022 250 17.2 4170 112 16,900 453 19,500 523
Silver 30 2.1 590 15.8 2310 61.9 4360 117 6000 161
40 2.8 820 22.0 3250 87.1 6320 169 10,000 268
50 3.5 1000 26.8 4030 108 8010 215 13,400 359
60 4.1 1170 31.4 4780 128 10,200 273 17,800 477
80 5.5 1490 39.9 6060 162 12,900 346 22,600 606
20 1.4
100 6.9 1800 48.2 7340 197 15,700 421 24,000 634
125 8.6 2200 59.0 8940 240 19,100 512 28,000 750
150 10.3 2580 69.1 10,500 281 22,500 603
200 13.8 3370 90.3 13,700 367 28,000 750
250 17.2 4170 112 16,900 453 28,000 750
50 3.5 930 24.9 3680 98.6 7090 190 11,000 295
60 4.1 1140 30.6 4530 121 8880 238 14,800 397
80 5.5 1490 39.9 6060 162 12,900 346 22,600 606
100 6.9 1800 48.2 7340 197 15,700 421 27,400 734
30 2.1
125 8.6 2200 59.0 8940 240 19,100 512 33,300 892
150 10.3 2580 69.1 10,500 281 22,500 603
200 13.8 3370 90.3 13,700 367 28,000 750
250 17.2 4170 112 16,900 453 28,000 750
60 4.1 1030 27.6 4070 109 7770 208 10,400 279
80 5.5 1450 38.9 5790 155 11,400 306 19,000 509
100 6.9 1790 48.0 7340 197 15,700 421 27,400 734
40 2.8 125 8.6 2200 59.0 8940 240 19,100 512 33,300 892
150 10.3 2580 69.1 10,400 279 20,000 536
200 13.8 3370 90.3 13,500 362 20,000 536
250 17.2 4170 112 16,900 453 20,000 536
60 4.1 820 22.0 3210 86.0 5970 160 7500 201
70 4.8 1130 30.3 4450 119 8430 226 10,600 284
80 5.5 1370 36.7 5420 145 10,500 281 17,000 456
100 6.9 1770 47.4 7060 189 14,000 375 23,300 624
50 3.5
35 to 100 psig / 125 8.6 2200 59.0 8940 240 19,100 512 33,300 892
2.4 to 6.9 bar 150 10.3 2590 69.4 10,400 279 22,500 603
1K748527202 200 13.8 3370 90.3 13,500 362 29,000 777
Red 250 17.2 4170 112 16,900 453 29,000 777
80 5.5 1220 32.7 4790 128 9050 243 12,000 322
100 6.9 1700 45.6 6730 180 13,100 351 21,600 579
125 8.6 2170 58.2 8700 233 17,300 464 28,400 761
60 4.1
150 10.3 2580 69.1 10,300 276 22,500 603
200 13.8 3370 90.3 13,500 362 29,400 788
250 17.2 4170 112 16,900 453 32,000 858
100 6.9 1490 39.9 5870 157 11,100 297 17,000 456
125 8.6 2080 55.7 8250 221 16,000 429 26,600 713
75 5.2 150 10.3 2550 68.3 10,200 273 20,300 544
200 13.8 3370 90.3 13,500 362 29,400 788
250 17.2 4170 112 16,900 453 36,200 970
– Maximum operating inlet pressure is exceeded.

- continued -

6
Bulletin 71.2:627F
Table 6. F
 low Capacities in SCFH / Nm3/h of 0.6 Specific Gravity Natural Gas at 1% Droop in Absolute Outlet Pressure for 3/4 NPT
(Downstream Control Line in Body Size Piping) (continued)
OUTLET 3/4 NPT BODY SIZE
PILOT SPRING RANGE, INLET
PRESSURE
PART NUMBER, AND PRESSURE Orifice Diameter, Inches / mm
SETTING
COLOR CODE
psig bar psig bar 3/8 x 1/8 / 9.5 x 3.2 3/8 x 1/4 / 9.5 x 6.4 3/8 / 9.5 1/2 / 13
35 to 100 psig / 125 8.6 1660 44.5 6680 179 12,500 335 18,000 482
2.4 to 6.9 bar 150 10.3 2360 63.3 9320 250 17,900 480
100 6.9
1K748527202 200 13.8 3330 89.2 13,400 359 26,600 713
Red 250 17.2 4170 112 16,900 453 36,200 970
– Maximum operating inlet pressure is exceeded.

Table 7. F
 low Capacities in SCFH / Nm3/h of 0.6 Specific Gravity Natural Gas at 1% Droop in Absolute Outlet Pressure for NPS 1 / DN 25
(Downstream Control Line in Body Size Piping)
OUTLET NPS 1 / DN 25 BODY SIZE
PILOT SPRING RANGE, INLET
PRESSURE
PART NUMBER, AND PRESSURE Orifice Diameter, Inches / mm
SETTING
COLOR CODE
psig bar psig bar 3/8 x 1/8 / 9.5 x 3.2 3/8 x 1/4 / 9.5 x 6.4 3/8 / 9.5 1/2 / 13
30 2.1 700 18.8 2840 76.1 6040 162 10,100 271
40 2.8 860 23.1 3500 93.8 7480 200 13,100 351
50 3.5 1020 27.3 4140 111 8850 237 15,400 413
60 4.1 1170 31.4 4780 128 10,200 273 17,800 477
80 5.5 1490 39.9 6060 162 12,900 346 18,500 496
5 0.34
100 6.9 1800 48.2 7340 197 15,700 421 18,500 496
125 8.6 2200 59.0 8940 240 18,500 496 18,500 496
150 10.3 2580 69.1 10,500 281 18,500 496
200 13.8 3370 90.3 13,700 367 18,500 496
250 17.2 4170 112 16,900 453 18,500 496
30 2.1 690 18.5 2760 74.0 5840 157 8930 239
40 2.8 860 23.1 3500 93.8 7480 200 13,100 351
50 3.5 1020 27.3 4140 111 8850 237 15,400 413
60 4.1 1170 31.4 4780 128 10,200 273 17,800 477
80 5.5 1490 39.9 6060 162 12,900 346 22,600 606
10 6.9
100 6.9 1800 48.2 7340 197 15,700 421 22,600 606
125 8.6 2200 59.0 8940 240 19,100 512 22,600 606
5 to 35 psig / 150 10.3 2580 69.1 10,500 281 22,500 603
0.34 to 2.4 bar 200 13.8 3370 90.3 13,700 367 22,600 606
1B788327022 250 17.2 4170 112 16,900 453 22,600 606
Silver 30 2.1 590 15.8 2310 61.9 4820 129 6400 172
40 2.8 820 22.0 3250 87.1 6830 183 10,500 281
50 3.5 1000 26.8 4030 108 8500 228 13,400 359
60 4.1 1170 31.4 4780 128 10,200 273 17,800 477
80 5.5 1490 39.9 6060 162 12,900 346 22,600 606
20 1.4
100 6.9 1800 48.2 7340 197 15,700 421 27,400 734
125 8.6 2200 59.0 8940 240 19,100 512 33,300 892
150 10.3 2580 69.1 10,500 281 22,500 603
200 13.8 3370 90.3 13,700 367 29,400 788
250 17.2 4170 112 16,900 453 33,300 892
50 3.5 930 24.9 3680 98.6 7720 207 11,700 314
60 4.1 1140 30.6 4530 121 9540 256 15,600 418
80 5.5 1490 39.9 6060 162 12,900 346 22,600 606
100 6.9 1800 48.2 7340 197 15,700 421 27,400 734
30 2.1
125 8.6 2200 59.0 8940 240 19,100 512 33,300 892
150 10.3 2580 69.1 10,500 281 22,500 603
200 13.8 3370 90.3 13,700 367 29,400 788
250 17.2 4170 112 16,900 453 36,200 970
60 4.1 1030 27.6 4070 109 8530 229 11,000 300
80 5.5 1450 38.9 5790 155 12,200 327 20,000 536
35 to 100 psig /
100 6.9 1790 48.0 7340 197 15,700 421 27,400 734
2.4 to 6.9 bar
40 2.8 125 8.6 2200 59.0 8940 240 19,100 512 33,300 892
1K748527202
150 10.3 2580 69.1 10,400 279 22,500 603
Red
200 13.8 3370 90.3 13,500 362 29,400 788
250 17.2 4170 112 16,900 453 36,200 970
– Maximum operating inlet pressure is exceeded.

- continued -

7
Bulletin 71.2:627F
Table 7. F
 low Capacities in SCFH / Nm3/h of 0.6 Specific Gravity Natural Gas at 1% Droop in Absolute Outlet Pressure for NPS 1 / DN 25
(Downstream Control Line in Body Size Piping) (continued)
OUTLET NPS 1 / DN 25 BODY SIZE
PILOT SPRING RANGE, INLET
PRESSURE
PART NUMBER, AND PRESSURE Orifice Diameter, Inches / mm
SETTING
COLOR CODE
psig bar psig bar 3/8 x 1/8 / 9.5 x 3.2 3/8 x 1/4 / 9.5 x 6.4 3/8 / 9.5 1/2 / 13
70 4.8 1130 30.3 4450 119 9300 249 11,200 300
80 5.5 1370 36.7 5420 145 11,400 306 18,300 490
100 6.9 1770 47.4 7060 189 14,900 399 24,400 654
50 3.4 125 8.6 2200 59.0 8940 240 19,100 512 33,300 892
150 10.3 2590 69.4 10,400 279 22,500 603
200 13.8 3370 90.3 13,500 362 29,400 788
250 17.2 4170 112 16,900 453 36,200 970
80 5.5 1220 82.7 4790 128 10,000 268 12,900 346
100 6.9 1700 45.6 6730 180 14,200 381 22,900 614
35 to 100 psig / 125 8.6 2170 58.2 8700 233 18,400 493 30,300 812
60 4.1
2.4 to 6.9 bar 150 10.3 2580 69.1 10,300 276 22,500 603
1K748527202 200 13.8 3370 90.3 13,500 362 29,400 788
Red 250 17.2 4170 112 16,900 453 36,200 970
100 6.9 1490 39.9 5870 157 12,300 330 18,000 482
125 8.6 2080 55.7 8250 221 16,900 453 28,100 753
75 5.2 150 10.3 2550 68.3 10,200 273 20,300 544
200 13.8 3370 90.3 13,500 362 29,400 788
250 17.2 4170 112 16,900 453 36,200 970
125 8.6 1660 44.5 6680 179 13,900 373 19,400 520
150 10.3 2360 63.3 9320 250 20,000 536
100 6.9
200 13.8 3330 89.2 13,400 359 28,300 758
250 17.2 4170 112 16,900 453 36,200 970
– Maximum operating inlet pressure is exceeded.

Table 8. F
 low Capacities in SCFH / Nm3/h of 0.6 Specific Gravity Natural Gas at 1% Droop in Absolute Outlet Pressure for NPS 2 / DN 50
(Downstream Control Line in Body Size Piping)
OUTLET NPS 2 / DN 50 BODY SIZE
PILOT SPRING RANGE, INLET
PRESSURE
PART NUMBER, AND PRESSURE Orifice Diameter, Inches / mm
SETTING
COLOR CODE
psig bar psig bar 3/8 x 1/8 / 9.5 x 3.2 3/8 x 1/4 / 9.5 x 6.4 3/8 / 9.5 1/2 / 13
30 2.1 700 18.8 2840 76.1 6150 165 10,100 271
40 2.8 860 23.1 3500 93.8 7760 208 13,800 370
50 3.5 1020 27.3 4140 111 9180 246 16,300 437
60 4.1 1170 31.4 4780 128 10,600 284 18,800 504
80 5.5 1490 39.9 6060 162 13,400 359 23,800 638
5 0.34
100 6.9 1800 48.2 7340 197 16,300 437 28,900 775
125 8.6 2200 59.0 8940 240 19,800 531 30,000 804
150 10.3 2580 69.1 10,500 281 23,400 627
200 13.8 3370 90.3 13,700 367 30,000 804
250 17.2 4170 112 16,900 453 30,000 804
30 2.1 690 18.5 2760 74.0 5870 157 9500 255
40 2.8 860 23.1 3500 93.8 7760 208 13,800 370
50 3.5 1020 27.3 4140 111 9130 246 16,300 437
5 to 35 psig / 60 4.1 1170 31.4 4780 128 10,600 284 18,800 504
0.34 to 2.4 bar 80 5.5 1490 39.9 6060 162 13,400 359 23,800 638
10 0.69
1B788327022 100 6.9 1800 48.2 7340 197 16,300 437 28,900 775
Silver 125 8.6 2200 59.0 8940 240 19,800 531 35,100 941
150 10.3 2580 69.1 10,500 281 23,400 627
200 13.8 3370 90.3 13,700 367 30,500 817
250 17.2 4170 112 16,900 453 37,600 1008
30 2.1 590 15.8 2310 61.9 4750 127 7000 188
40 2.8 820 22.0 3250 97.1 6820 183 10,900 292
50 3.5 1000 26.8 4030 108 8570 230 13,900 373
60 4.1 1170 31.4 4780 128 10,600 284 18,800 410
80 5.5 1490 39.9 6060 162 13,400 359 23,800 638
20 1.4
100 6.9 1800 48.2 7340 197 16,300 437 28,900 775
125 8.6 2200 59.0 8940 240 19,800 531 35,100 941
150 10.3 2580 69.1 10,500 281 23,400 627
200 13.8 3370 90.3 13,700 367 30,500 817
250 17.2 4170 112 16,900 453 37,600 1008
– Maximum operating inlet pressure is exceeded.

- continued -

8
Bulletin 71.2:627F
Table 8. F
 low Capacities in SCFH / Nm3/h of 0.6 Specific Gravity Natural Gas at 1% Droop in Absolute Outlet Pressure for NPS 2 / DN 50
(Downstream Control Line in Body Size Piping) (continued)
OUTLET NPS 2 / DN 50 BODY SIZE
PILOT SPRING RANGE, INLET
PRESSURE
PART NUMBER, AND PRESSURE Orifice Diameter, Inches / mm
SETTING
COLOR CODE
psig bar psig bar 3/8 x 1/8 / 9.5 x 3.2 3/8 x 1/4 / 9.5 x 6.4 3/8 / 9.5 1/2 / 13
50 3.5 930 24.9 3680 98.6 7670 206 12,100 324
60 4.1 1140 30.6 4530 121 9540 256 15,300 410
5 to 35 psig / 80 5.5 1490 39.9 6060 162 13,500 362 23,800 638
0.34 to 2.4 bar 100 6.9 1800 48.2 7340 197 16,300 437 28,900 775
30 2.1
1B788327022 125 8.6 2200 59.0 8940 240 19,800 531 35,100 941
Silver 150 10.3 2580 69.1 10,500 281 23,400 627
200 13.8 3370 90.3 13,700 367 30,500 817
250 17.2 4170 112 16,900 453 37,600 1008
60 4.1 1030 27.6 4070 109 8440 226 12,000 322
80 5.5 1450 38.9 5790 155 12,300 330 19,700 528
100 6.9 1790 48.0 7340 197 16,300 437 28,900 775
40 2.8 125 8.6 2200 59.0 8940 240 19,800 531 35,100 941
150 10.3 2580 69.1 10,400 279 23,400 627
200 13.8 3370 90.3 13,500 362 30,500 817
250 17.2 4170 12 16,900 453 37,600 1008
70 4.8 1130 30.3 4450 119 8460 227 14,000 375
80 5.5 1370 36.7 5420 145 11,300 303 17,900 480
100 6.9 1770 47.4 7060 189 15,000 402 24,200 649
50 3.4 125 8.6 2200 59.0 8940 240 19,800 531 35,100 941
150 10.3 2590 69.4 10,400 279 23,400 627
200 13.8 3370 90.3 13,500 362 30,500 817
35 to 100 psig / 250 17.2 4170 112 16,900 453 37,600 1008
2.4 to 6.9 bar
80 5.5 1220 32.7 4790 128 9860 264 14,000 375
1K748527202
100 6.9 1700 45.6 6730 180 14,100 378 22,400 600
Red
125 8.6 2170 58.2 8700 233 18,500 496 30,000 804
60 4.1
150 10.3 2580 69.1 10,300 276 23,400 627
200 13.8 3370 90.3 13,500 362 30,500 817
250 17.2 4170 112 16,900 453 37,600 1008
100 6.9 1490 39.9 5870 157 12,100 324 18,800 504
125 8.6 2080 55.7 8250 221 17,300 464 27,600 740
75 5.2 150 10.3 2550 68.3 10,200 273 21,700 582
200 13.8 3370 90.3 13,500 362 30,500 817
250 17.2 4170 112 16,900 453 37,600 1008
125 8.6 1660 44.5 6680 179 13,700 367 21,200 568
150 10.3 2360 63.3 9320 250 19,400 520
100 6.9
200 13.8 3330 89.2 13,400 359 28,500 764
250 17.2 4170 112 16,900 453 37,600 1008
– Maximum operating inlet pressure is exceeded.

52
OUTLET PRESSURE, psig

OUTLET PRESSURE, bar

51
3.5

50 ± 1%

2
3.4
49

0 0.00
0/0 5 / 0.1 10 / 0.3 15 / 0.4 20 / 0.5 25 / 0.7 30 / 0.8 35 / 0.9

FLOW RATE THOUSANDS OF SCFH / Nm3/h OF 0.6 SPECIFIC GRAVITY NATURAL GAS

2   3/8-INCH / 9.5 mm ORIFICE. ACTUATOR SPRING 35 to 100 psig /


2.4 to 6.9 bar RANGE (RED COLOR CODE) PILOT SPRING 200 psig / 13.8 bar
INLET PRESSURE

Figure 3. Typical Performance Curve for 3/4 NPT Type 627F Regulator

9
Bulletin 71.2:627F

10.5 / 267

5.50 / 140

8.06 / 205
1.00 /
25.4

TYPE P594-1 A
TYPE 6351F FILTER
B
(OPTIONAL)

Ø 4.69 /
119
G D
12B2138_E

F
9.12 / 232

5.50 / 140
TYPE 6351F

1/4 NPT SUPPLY 8.06 / 205


CONNECTION
WITH OPTIONAL
TYPE P594-1 FILTER
B

Ø 4.69 /
119

G D

12B7144_C
INCHES / mm

Figure 4. Dimensions

Table 9. Dimensions
BODY SIZE DIMENSIONS, Inches / mm
END CONNECTION
STYLE A B D F G
Inches DN

3/4 ---- NPT 4.06 103 1.94 49 6.75 171 ---- ---- 2.00 51
1 ---- NPT 4.06 103 1.94 49 6.75 171 ---- ---- 2.00 51
CL150 RF 7.25 184 3.62 92 2.12 54
CL300 RF 7.75 197 3.88 99 2.44 62
1 25 6.75 171 4.38 111
CL600 RF 8.25 210 4.12 105 2.44 62
PN 16/25/40 7.80 198 3.90 99 2.31 59
NPT 5.00 127 2.50 64 7.12 181 ---- ---- 2.62 67
CL150 RF 10.00 254 5.00 127 3.00 76
2 50 CL300 RF 10.50 267 5.25 133 3.25 83
7.12 181 4.75 121
CL600 RF 11.25 286 5.62 143 3.25 83
PN 16/25/40 10.31 262 5.16 131 3.25 83

10
Bulletin 71.2:627F
Ordering Information
Application Construction
When ordering, specify: Refer to the specifications and to each referenced
table; specify the desired selection whenever there is a
  1. Type of regulator choice to be made. The standard assembly position is
  2. Body size shown in Figure 1, but an alternate assembly position
  3. Body material and trim material may be factory-ordered or can be accomplished in the
field by unbolting the body or spring case using the
  4. Orifice size in inches / mm instructions in the appropriate section of the instruction
  5. Control spring range in psig / bar manual. For installation dimensions, refer to Figure 4.

Ordering Guide
Body Material, Body Size, and End Connection Style Trim Material (Select One)
(Select One)     Aluminum***
Ductile Iron     Stainless steel***
    3/4 NPT*** Orifice Size (Select One)
    1 NPT***     3/8 x 1/8-inch / 9.5 x 3.2 mm**
    2 NPT***     3/8 x 1/4-inch / 9.5 x 6.4 mm**
WCC Steel     3/8-inch / 9.5 mm***
    3/4 NPT***     1/2-inch / 13 mm***
    1 NPT*** Outlet Pressure Range (Select One)
    NPS 1 / DN 25, CL150 RF**     5 to 35 psig / 0.34 to 2.4 bar, Unpainted***
    NPS 1 / DN 25, CL300 RF**     35 to 100 psig / 2.4 to 6.9 bar, Red***
    NPS 1 / DN 25, CL600 RF**
    NPS 1 / DN 25, PN 16/25/40** Pilot Supply Filter (Optional)
    2 NPT***     Type P594-1
    NPS 2 / DN 50, CL150 RF**
Pilot Supply Steel Tubing (Optional)
    NPS 2 / DN 50, CL300 RF**
    NPS 2 / DN 50, CL600 RF**     With Type P594-1 Filter
    NPS 2 / DN 50, PN 16/25/40**     Without Filter
Spring Case and Diaphragm Casing Material Replacement Parts Kit (Optional)
(Select One)     Yes, send one replacement parts kit to match this order.
    Aluminum***
    Ductile iron***
    WCC steel***

11
Bulletin 71.2:627F

Specification Worksheet
Application:
Specific Use
Line Size
Gas Type and Specific Gravity
Gas Temperature
Does the Application Require Overpressure Protection?
   Yes    No  If yes, which is preferred:
    Relief Valve    Monitor Regulator    Shutoff Device
Is overpressure protection equipment selection assistance
desired?
Pressure:
Maximum Inlet Pressure (P1max)
Minimum Inlet Pressure (P1min)
Downstream Pressure Setting(s) (P2)
Regulators Quick Order Guide Maximum Flow (Qmax)
*** Readily Available for Shipment Performance Required:
** Allow Additional Time for Shipment Accuracy Requirements?
* Special Order, Constructed from Non-Stocked Parts. Consult Need for Extremely Fast Response?
Your local Sales Office for Availability.
Other Requirements:
Availability of the product being ordered is determined by the component with the
longest shipping time for the requested construction.

Industrial Regulators Natural Gas Technologies TESCOM

Emerson Process Management Emerson Process Management Emerson Process Management


Regulator Technologies, Inc. Regulator Technologies, Inc. Tescom Corporation
USA - Headquarters USA - Headquarters USA - Headquarters
McKinney, Texas 75069-1872, USA McKinney, Texas 75069-1872, USA Elk River, Minnesota 55330-2445, USA
Tel: +1 800 558 5853 Tel: +1 800 558 5853 Tels: +1 763 241 3238
Outside U.S. +1 972 548 3574 Outside U.S. +1 972 548 3574     +1 800 447 1250
Asia-Pacific Asia-Pacific Europe
Shanghai 201206, China Singapore 128461, Singapore Selmsdorf 23923, Germany
Tel: +86 21 2892 9000 Tel: +65 6770 8337 Tel: +49 38823 31 287
Europe Europe Asia-Pacific
Bologna 40013, Italy Bologna 40013, Italy Shanghai 201206, China
Tel: +39 051 419 0611 Tel: +39 051 419 0611 Tel: +86 21 2892 9499
Chartres 28008, France
Middle East and Africa
Tel: +33 2 37 33 47 00
Dubai, United Arab Emirates
Tel: +971 4811 8100

For further information visit www.fisherregulators.com

The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls International LLC,
a business of Emerson Process Management.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or
guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such
products at any time without notice.
Emerson Process Management Regulator Technologies Inc. does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and
maintenance of any Emerson Process Management Regulator Technologies Inc. product remains solely with the purchaser.

©Emerson Process Management Regulator Technologies, Inc., 1990, 2013; All Rights Reserved

You might also like