You are on page 1of 2
| YESHA ELECTRICALS TRADING & MANUFACTURING PANNEL, PLANT AUTOMATION AL! |NDLUISTRIAL SERVICE PROVIDER CONTACT NO: +91 9409034216 EMAIL: yeshaeiectiyahoo.cu.in SERVICING TECHNICAL PEPORT DATE: 10/08/2019 Customer: TEADIT PACKING AND GASKETS PVT. LTD. - MANJUSAR GIDC Our Ref: YE/52/19-20 Item 01:Drive for horizontal SWG machine-Siemens 1.5KW 200V 1PHASE Problem: Drive is blasting when it is switched on the power. Diagnostic: Found PCB (control), SMD, power module and PCE keypad display damaged due to short circuit Actions: ‘© Repairing PCB (control); ‘© Replacing SMD component; ‘© Repairing power module; ‘+ Repairing PCB Keypad display; * Labor for drive installation and configuration ftem 02:Transformer for stretching machine - 15KVA, 3PHASE, “40'v (20A] I 220V (40A), Freq SOH2 Problem: The transformer is not feeding the machines once switched on and connected to the power net. Diagnostic: Found water Inside the transformer and the copper coils found burned due to short circuit. Actions: ‘© Rewinding the copper coil; ‘+ Replace the indication lamps (3 nos); ‘* Replace the terminal block; Labor for transformer installation Item 03:Transformer for Chinese vertical SWG machine Problem: The transformer is not feeding the machine once sw'ched | and connected to the Chinese vertical SWG machine. Diagnostic: Found water inside the transformer and the copper coils found burned due to short circuit. Actions: ‘* Rewinding the copper coil; * Replace the indication lamps (3nos); ‘* Replace the terminal block; ‘+ Labor for transformer installation, {tem 04:Cable of the transformer for stretching machine - 4 CORE 10MM Page 1 YESHA ELECTRICALS tr TRADING & MANUFACTURING PANNEL, PLANT AUTOMATION ALL INDUSTRIAL SERVICE PROVIDER. CONTACT NO: +91 9409034216 EMAIL: yeshaelect@yahoo.co.in Problem: Cable damaged. Diagnostic: Cable blasted due to the short circuit in the transformer of the stretching machine. Actions: ‘+ Replace the cable from the main panel up to th» stretch ing * Labor to place the new cable on the busway and make Item 05:Fuse of the distribution pane! Problem:Machines in the spiral wound area are not fed by power. Diagnostic: Due to the short circuit on the transformer ‘he fuse was burned as jts function in the system to protect the main power. i Action: 7 ¢ Replace the fuses on the main panel; ‘+ Labor forthe replacement. Item 06:Footswitch for DJ machine Problem:Footswitch not working. Diagnostic: Switch contacts damage due to the short cit ‘Action: _-@_Replace the contacts, cle ‘* Labor forthe replacement. inside), and dry inside the footswitch; office : 8-84, Bhaktinagar Opp. Novino, Makarpui2 ,Volodava 307 030 (Mi) 9409034216 yeshaelect@yahoo.co.in_

You might also like