became a reality
Since its establishment in 1960, Mecalor has been focused on providing
the best cost-effective solutions for thermal control applications. The
trust of our customers in an outstanding service and high quality products
legitimate our proven leadership in the markets we operate.
WHAT The Reason to Exist
HOW
If you want a partner who will settle down only when
delivering the best, you have come to the right place.
WHY Love to innovate, boldness to challenge the status quo and pleasure to solve complexissues
are part of our brand. We believe that our greatest legacy will be the trust shown by customers
in our work.
Competence Pillars
Automotive Industry
Hospital Market
Pharmaceutical Industry
Food Industry
Electric Appliances
Data Centers
Others
Engineering Department
of the Mecalor in São Paulo
First World Engineering
Made in Brazil
Our commitment
The passion to overcome limits is our driving force. We are determined to
offer products and services with the best available technology and with
first world quality standards. To make this dream a reality, we count on
the commitment of an exceptional team consisting of professionals with
decades of years of experience in the company guiding the youths with a
lot of energy and willingness to learn.
Quality Policy
Professional
Happiness
Seek the development of the
Customer people and make them have
Satisfaction pride in their work.
Continuous Innovation
To be recognized as a
technological company of
reference in innovation and
pioneerism.
Table of Contents
Products by Application
Process Cooling 20
Plastic Transformation 30
DryCooler 38
Diagnostic Medicine 44
Drug Stability 50
Climatic Tests 62
Integrated Projects 84
Microchannel
Room air
maximum temperature
Expansion Valve
42ºC Water
filter
Replacement
Cold water
Industrial water
maximum temperature
Expansion Valve
Replacement
Cold water
22
MiniChiller MCA Compact Chiller MSA
Refrigeration capacity of 3 to 5,000 kcal/h Refrigeration capacity of 5 to 75,000 kcal/h
Easy-to-operate micro-processed control PLC with touch screen and complete diagnosis of failures
Economic and easy installation Double refrigeration circuit from 30,000 kcal/h
kcal/h kW kVA Width Length Height m³/h mca Liters m³/h Process kg
MCA-3 3,000 2.1 3.0 483 656 868 0.8 24 20 2,400 3/4" 150
MCA-5 5,000 2.6 3.8 483 666 868 1.4 30 20 2,400 3/4" 165
MSA-5 6,000 3.5 6.0 670 920 1,285 1.5 30 30 7,500 1" 180
MSA-9 9,500 4.6 7.5 670 920 1,285 1.5 30 30 7,500 1" 200
MSA-15 16,500 6.3 10.5 802 951 1,381 3.2 30 30 8,000 1.1/2" 300
MSA-22 22,500 8.8 13.7 858 1,257 1,538 6.2 30 60 8,000 1.1/2" 370
MSA-30 30,400 10.5 18.6 831 1,360 1,945 6.2 30 60 9,200 1.1/2" 430
MSA-45 43,600 17.6 27.7 831 1,660 1,945 16.4 30 90 17,700 2" 500
MSA-60 63,800 23.4 37.8 831 1,660 1,945 16.4 30 90 17,700 2" 525
MSA-75 74,200 25.6 43.3 831 2,230 1,945 16.4 30 110 26,400 2" 600
1. A dual independent cooling circuit is standard in model MSA-30 and above.
2. Refrigeration capacities apply to chilled water leaving at 10°C and returning at 14°C, with 27°C room temperature.
3. Active power with chiller operating at full capacity, and chilled water at 10°C.
4. Total power for electric supply sizing purposes shall not be considered as power consumption. For data of customized equipment, please contact Mecalor's engineering department.
Process Cooling 23
MSW Compact Chiller
Refrigeration capacity of 5 to 75,000 kcal/h Integrated stainless steel tank and pump
Adjustable cold water temperature from 5 to 25°C PLC with touch screen and complete diagnosis of
R-410A ecological refrigerant failures
Double refrigeration circuit from 30,000 kcal/h
Water condensation
with high efficiency plate
heat exchanger
kcal/h kW kVA Width Length Height m³/h mca liters m³/h Process Condensation kg
MSW-5 6,000 2.4 5.1 670 920 1,031 1.5 30 30 1.4 1" 1" 180
MSW-9 9,500 3.4 7.2 670 920 1,031 1.5 30 30 2.3 1" 1" 200
MSW-15 16,000 4.8 9.4 802 900 1,406 3.2 30 65 4.2 1.1/2" 1.1/2" 300
MSW-22 23,000 6.9 12.5 802 900 1,406 6.2 30 80 5.7 1.1/2" 1.1/2" 370
MSW-30 32,000 8.7 17.7 828 1,250 1,573 6.2 30 110 8.4 1.1/2" 1.1/2" 500
MSW-45 45,000 13.8 24.8 828 1,250 1,573 16.4 30 110 11.4 1.1/2" 1.1/2" 700
MSW-60 66,000 19.0 33.3 828 1,250 1,573 16.4 30 110 15.2 2" 2" 800
MSW-75 76,000 21.5 40.2 830 1,250 1,573 16.4 30 110 15.2 2" 2" 850
1. A dual independent cooling circuit is standard in model MSW-30 and above.
2. Refrigeration capacities apply to chilled water leaving at 10°C and returning at 14°C, with industrial water at 30°C.
3. Active power with chiller operating at full capacity, and chilled water at 10°C.
4. Total power for electric supply sizing purposes shall not be considered as power consumption. For data of customized equipment, please contact Mecalor's engineering department.
24
RLA Industrial Chiller
Refrigeration capacity of 80 to 850,000 kcal/h Integrated stainless steel tank and pump
Adjustable cold water temperature from 5 to 25°C PLC with touch screen and complete diagnosis of failures
R-410A ecological refrigerant Double refrigeration circuit from 30,000 kcal/h
Maximum
power
efficiency
kcal/h kW kVA Width Length Height m³/h mca Liters m³/h Process kg
RLA-80 75,500 23.5 44.1 1,146 2,604 2,619 16.5 30 290 43,000 3" 1,100
RLA-100 98,000 35.4 58.5 1,146 2,604 2,619 28.0 30 290 43,000 3" 1,300
RLA-130 127,500 47.6 73.9 1,146 2,604 2,619 40.0 30 290 43,000 3" 1,500
RLA-170 163,000 55.9 89.7 1,146 3,154 3,003 40.0 30 290 64,500 3" 1,600
RLA-210 208,000 72.1 112.4 1,146 3,154 3,003 60.0 30 290 64,500 3" 1,700
RLA-260 258,500 88.3 142.9 2,400 2,580 2,760 70.0 30 420 86,000 4" 2,000
RLA-330 324,000 107.9 176.6 2,400 3,740 2,760 86.0 30 420 129,000 4" 2,500
RLA-400 404,500 139.0 219.0 2,400 3,740 2,760 103.0 30 420 129,000 4" 3,900
RLA-500 481,500 161.6 292.3 2,400 5,071 2,760 145.0 30 730 172,000 6" 4,400
RLA-620 622,000 205.2 338.8 2,400 6,240 2,760 148.0 30 730 215,000 6" 5,200
RLA-750 762,000 266.8 429.2 2,400 7,401 2,760 170.0 30 730 258,000 6" 6,000
Process Cooling 25
RLAC air conditioning chiller
Complies with ARI standard for air conditioning Air condensation with microchannel heat exchangers
units Refrigeration capacity of 100 to 420 TR PLC with touch screen and complete diagnosis of
Integrated process water filter failures
R-410A ecological refrigerant Washable air filters for condensers
Independent double refrigeration circuit
Maximum
power
efficiency
Inverter
Rated Capacity (1) Condensation Compressors Cooling fluid Hydronic Kit Adiabatic Kit Soft start
Model (1) Compressor
TR kcal/h Air (A) Water (W) Scroll (S) Bolt (P) Scroll (S) Bolt (P) - - - -
26
RLW industrial chiller
Refrigeration capacity of 80 to 850,000 kcal/h Water condensation with plate heat exchanger
Compact and low noise level Integrated stainless steel tank and pump
R-410A ecological refrigerant PLC with touch screen and complete diagnosis of failures
Maximum power efficiency Integrated water filter for evaporator and condenser
Robust
build with
fairing
kcal/h kW kVA Width Length Height m³/h mca liters m³/h Process Condensation kg
RLW-80 76,000 21.5 40.2 1,327 1,801 2,107 16.5 30 280 20.3 3" 3" 1,100
RLW-100 100,000 29.0 55.5 1,327 1,801 2,107 28.0 30 280 23.9 3" 3" 1,300
RLW-130 137,000 38.4 68.9 1,327 1,801 2,107 40.0 30 280 34.2 3" 3" 1,500
RLW-170 170,000 46.8 84.7 1,327 1,801 2,107 40.0 30 280 40.2 3" 3" 1,600
RLW-210 220,000 60.0 108.8 1,327 1,801 2,107 60.0 30 280 49.3 3" 3" 1,700
RLW-260 268,000 74.3 131.9 2,160 2,606 2,425 70.0 30 720 63.2 4" 4" 2,000
RLW-330 336,000 92.3 167.6 2,160 2,606 2,425 86.0 30 720 79.5 4" 4" 2,500
RLW-400 420,000 117.4 211.8 2,160 2,606 2,425 103.0 30 720 100.0 4" 4" 3,900
RLW-500 491,000 138.0 271.2 2,160 2,606 2,425 145.0 30 720 116.7 6" 6" 4,400
RLW-620 630,000 174.0 317.5 2,160 2,606 2,425 148.0 30 720 151.4 6" 6" 5,200
RLW-750 786,000 237.0 389.1 2,160 2,606 2,425 170.0 30 720 193.4 6" 6" 6,000
Process Cooling 27
Tailor-made solutions
With over 50 years of experience
in thermal engineering, Mecalor
is able to meet the most stringent
customer demands, both in product
customization and integration
of engineering and installation
services to its supply scope.
Pumping station
28
Process Cooling 00
ElectroPlastic
Integrated solution for the
plastic industry
Plastic
Transformation
Thermal control in the plastic forming process
An accurate temperature control is crucial in the plastic industry For each application and processed raw material,
there is an ideal cooling or heating solution.
USES
Chiller
DryCooler
ThermoRegu-
lator
ThermoChiller
Cold Air
Dry Air
ThermoChiller
140ºC
Modular and Compact DryCooler Thermoregulator Chillers Line ThermoChiller Dry, cold air units Heat Exchanger
(TC)
32
DUO TermoChiller
Water condensation with plate heat exchanger Low (ΔT) for higher precision of the items produced
Water filter for evaporator and condenser Temperature control in two zones, from 10 to 90°C
High water flow and pressure for injection and Water refrigeration and heating
blow Integrated stainless steel tank and pumps R-410A ecological refrigerant
kcal/h kW kW kVA Width Length Height m³/h mca m³/h Process Condensation kg
DUO 9/6 9,000 2x6 5.4 17.4 450 900 1,100 1.6 40 2.5 1" 3/4" 250
DUO 15/6 15,000 2x6 7.2 19.2 450 900 1,100 3.2 40 4.0 1" 3/4" 300
DUO 22/9 22,000 2x9 12.0 30.0 560 1,250 1,380 7.0 40 6.0 1.1/2" 1.1/4" 350
DUO 28/9 28,000 2x9 13.5 35.1 560 1,250 1,380 7.0 40 7.5 2" 1.1/4" 375
DUO 35/9 35,000 2x9 19.6 37.5 560 1,250 1,380 12.5 40 10.0 2" 1.1/4" 400
DUO 45/12 45,000 2 x 12 24.3 48.3 800 1,750 1,870 12.5 40 12.5 2" 1.1/2" 600
DUO 60/12 60,000 2 x 12 28.3 52.3 800 1,750 1,870 12.5 40 15.0 2.1/2" 2" 900
DUO 100/18 100,000 2 x 18 39.5 75.5 800 1,750 1,870 23.9 40 24.0 2.1/2" 2.1/2" 1,200
1. Capacities apply to water leaving at 10°C and condensation water at 35°C.
2. The operating electric power applies to equipment operation at full capacity, without any heating resistances, and chilled water leaving at 10°C.
3. Total power for electric supply sizing purposes shall not be considered as power consumption.
4. These data apply to each one of the two process pumps.
Plastic Transformation 33
Thermoregulator
1. The cooling capacity depends on the operating conditions. The TMR model has been sized to reach a T of 2°C between the cold source and process water.
2. This power value applies when the equipment is operating/cooling without the heating resistance.
3. Dimensions apply to the water-based TMR only. Contact us for the oil-based TMR.
34
Flexo Thermochiller
Adjustable temperature from 5 to 20°C for calenders and 25 to 50°C for the central drum
Single model of 20,000 kcal/h for flexographic printers of 4 to 12 colors
Air condensation with higefficiency microchannel heat exchangers
Accurate control of the central drum with stability of ±0.5°C
Hydraulic pump and circuit completely in stainless steel
Temperature control in two independent zones
Operation Piping
Cooling (1)
Heating Dimensions in millimeters Process pumP(3) Weight
Model Power(2) Diameter
1. This capacity applies to process water leaving at 15°C and room temperature at 40°C.
2. The power applies to equipment operation at full capacity, and chilled water at 10°C.
3. These data apply to both process pumps.
Plastic Transformation 35
Cold Air Unit CAU
Remote air condenser option (split type) Air temperature control with precision of ±0.5°C
Independent units for air ring and IBC Serves one layer extruder or COEX extruder up to 7 layers
Water condensation with plate heat exchanger Air temperature from 5 to 25 ºC to ensure productivity
It can be installed on the structure of the Bubble extruders with production up to 1000 kg/h of PEAD/
extruder PEBD
Heat Exchanger TC
UAF-W-1500 1,500 150 6.4 950 1,276 1,765 8" - 7 1.1/2" 350
UAF-W-2500 2,500 250 11.0 950 1,200 1,765 8" - 11 1.1/2" 450
UAF-W-4000 4,000 500 16.9 1,250 1,282 2,185 10" - 14 3" 800
UAF-W-6000 6,000 700 21.9 1,250 1,282 2,185 10" - 24 3" 950
1. The Cold Air Unit (UAF) operates with an adjustable air temperature between 5 and 20°C. The heat exchanger (TC) operates with air temperature 5°C above the available chilled water temperature.
2. Sizing based on the average LDPE plastic film production, with air at 15°C, valid for the air ring.
3. Active electric power with UAF operating at full capacity.
36
Dry Air Unit (DAU)
Power efficiency of 40 to 50% superior when compared to the use of desiccant rotor (chemical)
Allows cold water up to -5°C in the injection and blow molds without generating condensation in the cavities
It can be an individual unit per mold or a dry air central unit for one line of machines
Dehumidification technology by refrigeration with dew point of up to 4°C
Increases productivity and eliminates stains on the injected or blown items
Regeneration (reheating of dry air) through the condenser itself
Specially developed for injection and blow molds
Dry air flow rate Operation Power (1) Dimensions in millimeters Air outlet diameter Weight
Model
m³/h kW Width Length Height Inches kg
Plastic Transformation 37
MODULAR
DRYCOOLER
1. Capacity for São Paulo (base: ASHRAE Annual Evaporation Conditions 1%) process water leaving at 35oC and returning at 41oC. Please consult us for other cities and conditions.
2. Active electric power with DryCooler operating at full capacity. It does not include the power of the pumping station, which is provided on a separate basis.
3. Active electric power with DryCooler Compact operating at full capacity, including the process pump.
40
Water and power saving
Payback of 12 to 36 months
Reduces water consumption and treatment by 98%
Eliminates maintenance and cleaning costs of the heat exchangers and pipes
Zero waste of water with continuous humidification water recovery
Fans with
variable
speed
Hot and
wet air
130 µ
Return
Modular DryCooler 41
Return on Investment
The operating cost of the DryCooler is much lower when compared to cooling towers. This means a very attractive
payback, even considering a higher initial investment.
Required cooling capacity kW 1,200 Each 120 kW unit with industrial water serves around four 300-ton injectors.
Cooling water flow rate m³/h 188 Based on T. bulbo úmido = 24oC e (T.entrada - T.saída) = 5oC
Water provided by the utility company R$ /m³ 7.21 Average rate Brazil
Sewage rate of the utility company R$ /m³ 5.43 Average rate Brazil
DryCool-
Cost variable Unit Tower Remarks
er
Replacement water % flow rate 1,9% 0,06% DryCooler operating with humidification during 8 hours/day, 200 days a year
Cost of replacement water R$/month 27,815 878 Based on water and sewage cost, along with replacement water volume
Water treatment R$/month 3,300 104 Survey conducted with water treatment companies
Maintenance R$/month 42 124 Replacement of DryCooler's evaporation panel and tower's insulation/fans
Cleaning of heat exchangers R$/month 3,000 0 Required manpower to remove the scales created by water at the towers
Electric power R$/month 2,072 7,776 Electric power of R$ 0.30 / kWh and utilization factor of 70% for the DryCooler
Total operating cost R$/month 36,228 8,882 Monthly overall cost to operate each piece of equipment
Payback Term months 18.6 Recovery time of investment difference between Tower and DryCooler
42
High efficiency in hot days
Accurate temperature control of the industrial water of 30 to 35°C
Automatic air humidification system for hotter days
The chart below is based on the factory measurements, and it illustrates this effect. This result is possible only
thanks to the evaporation panel with large contact area (which enables low air speed), and also to the recirculation
pump, which retrieves the non-evaporated excess water, thus assuring the least possible water consumption.
Modular DryCooler 43
Diagnostic
MEDICINE
The certification granted to Mecalor attests the trust granted to us by worldwide leaders in radiology equipment.
46
IHA Medical Chiller
Exclusive for application in magnetic resonance (MRI), linear accelerator, PET-CT and Tomography (CT)
Stainless steel AISI 304 structured prepared for outdoor installation
R-410A ecological refrigerant does not damage the ozone layer
High durability and reliability in the most adverse conditions
Includes water filter and automatic safety by-pass
Low noise level for application in clinics and hospitals
Integrated stainless steel tank and pump
Robust and super compact design
Maximum power saving
IHA-75-RI dual 102 25.6 831 2,233 1,945 15.0 30 110 2" 600
1. The dual refrigeration circuit features two independent refrigeration circuits (compressors, evaporators and condensers).
2. Refrigeration capacities apply to chilled water leaving at 15°C and returning at 19°C, with 27°C room temperature.
3. Electric power with chiller operating at full capacity, and chilled water at 15°C. Consumption will be proportional to the actual thermal load.
4. Cabinet dimensions do not include the projection of external hydraulic, filter and bypass connections.
Diagnostic Medicine 47
Cooling and Air Conditioning Redundant Ch
Smart relay
In Mecalor's Integrated System, the chillers provide chilled water both for the
MR equipment and the rooms' air conditioning system.
Command Room
48
hillers Quench Pipe
Complies with all the specifica-
tions
Control panel
Simplicity and access
via internet
Technical Room
Examination Room
Diagnostic Medicine 49
Drug
Stability
Climatic Chamber
Integrated system
Climatic Chamber
Tailored solutions
Design and installation
Compatible with the regulatory standards
52
The scope may include: Conception
Mounting of the insulation panels
Installation of the air conditioner, air distribution ducts and racks
Installation, operational and performance qualifications (IQ, OQ and PQ)
Drug Stability 53
Stability Study
54
Photostability
The photostability climatic chamber ensures high precision during the visible light and UV radiation exposure
tests, complying with the recommendations of the National Health Surveillance Agency (ANVISA), Food and
Drug Administration - FDA and International Conference on Harmonisation - ICH, specifically ICH-Q1B
Inner Volume (3) Exposure Areas Dimensions in millimeters Rated Current (1) Installed Power (2) Drain Weight
Model
liters Qty. Width Length Height A kVA Inches kg
EC / 0,2 / AR-URC 200 12 1,027 582 1,796 11.4 2.5 3/4" BSP 250
Drug Stability 55
Precision
Air Conditioning
Hostdime
Complete solution
for data centers
Self Contained Precision Air Conditioner
The Self Contained Precision Air Conditioner – CPAS is an evaporation unit that includes compressor, evaporator,
fan and protection and control instrumentation.
kW ton (TR) Qty. m³/h Width Length Height Coefficient Compressor Fan Resistnece Humidifier Inches Inches kg
CPAS-12 13.4 3.8 1 5,000 740 740 1,977 0.96 4.9 1.2 4.5 2.3 5/8” x 1/32” 5/8” x 1/32” 250
CPAS-16 16.6 4.7 1 5,000 740 740 1,977 0.96 6.4 1.2 4.5 2.3 5/8” x 1/32” 5/8” x 1/32” 250
CPAS-20 21.6 6.1 1 7,500 740 740 1,977 0.96 8.8 1.2 4.5 2.3 5/8” x 1/32” 3/4” x 1/32” 250
CPAS-24 25.1 7.1 1 7,500 740 740 1,977 0.95 9.8 1.2 4.5 2.3 5/8” x 1/32” 3/4” x 1/32” 250
CPAS-30 30.0 8.5 1 9,000 1,500 740 1,977 0.91 12.3 1.2 4.5 2.3 3/4” x 1/32” 7/8” x 1/32” 350
CPAS-50 50.0 14.2 2 14,000 1,500 740 1,977 0.96 21.0 2.4 4.5 2.3 3/4” x 1/32” 7/8” x 1/32” 500
CPAS-70 64.0 18.2 2 18,000 1,500 740 1,977 0.87 28.0 2.4 4.5 2.3 7/8” x 1/32” 1.1/8” x 1/16” 500
CPAS-90 84.0 23.9 3 24,000 2,260 740 1,977 0.91 35.8 3.6 4.5 4.6 7/8” x 1/32” 1.1/8” x 1/32” 700
CPAS-120 110.0 31.3 4 30,000 3,000 1,200 1,977 0.91 41.6 4.8 4.5 4.6 1.1/8” x 1/32” 1.3/8” x 1/32” 900
CPAS-150 150.0 42.7 4 35,000 3,000 1,200 1,977 0.88 55.2 4.8 4.5 4.6 1.1/8” x 1/32” 1.3/8” x 1/32” 900
1. Sensible cooling capacity with condensation temperature at 45°C, air return temperature at 24°C and 45% relative humidity.
2. Resistance and humidifier power shall be considered only for units that include relative humidity and air heating control.
3. SHR (Sensitive Heat Ratio) or FCS (Sensitive Heat Factor). The best energy efficiency is indicated by values next to 1.0 in this coefficient.
4. Models CPAS-70 and above have two refrigeration circuits.
58
Fan & Coil type Precision Air Conditioning
The CPCS air conditioner is a fan & coil unit that insufflates air with controlled temperature and relative humidity
with precision in environments with high sensitive heat factor.
kW ton (TR) Qty. m³/h Width Length Height Coefficient Fan Resistnece Humidifier m³/h Inches Inches kg
CPCS-12 12.4 3.5 1 5,000 740 740 1,980 0.96 1.2 4.5 2.3 2.4 1" 1" 200
CPCS-16 16.6 4.7 1 5,000 740 740 1,980 0.96 1.2 4.5 2.3 3.0 1" 1" 200
CPCS-20 19.3 5.5 1 7,500 740 740 1,980 0.96 1.2 4.5 2.3 3.7 1.1/4" 1.1/4" 200
CPCS-24 23.5 6.7 1 7,500 740 740 1,980 0.95 1.2 4.5 2.3 4.4 1.1/4" 1.1/4" 200
CPCS-30 27.4 7.8 1 9,000 1,480 740 1,980 0.91 1.2 4.5 2.3 6.7 1.1/2" 1.1/2" 250
CPCS-50 48.0 13.7 2 14,000 1,480 740 1,980 0.96 2.4 4.5 2.3 9.9 1.1/2" 1.1/2" 400
CPCS-70 64.0 18.2 2 18,000 1,480 740 1,980 0.87 2.4 4.5 2.3 13.4 2" 2" 400
CPCS-90 84.0 23.9 3 24,000 2,220 740 1,980 0.91 3.6 4.5 4.6 17.2 2" 2" 500
CPCS-120 110.0 31.3 4 30,000 2,960 1,200 1,980 0.91 4.8 4.5 4.6 24.8 2.1/2" 2.1/2" 600
CPCS-150 150.0 42.7 4 35,000 2,960 1,200 1,980 0.88 4.8 4.5 4.6 28.7 2.1/2" 2.1/2" 600
1. Sensible cooling capacity with chilled water at 7°C, air return temperature at 24°C and 45% relative humidity.
2. Resistance and humidifier power shall be considered only for units that include relative humidity and air heating control.
3. SHR (Sensitive Heat Ratio) or FCS (Sensitive Heat Factor). The best energy efficiency is indicated by values next to 1.0 in this coefficient.
Climatização de Precissão 59
CPCO container
Cold Cold
Designed for air conditioning of Corridor Corridor
kW ton (TR) Qty. m³/h Width Length Height Coefficient Compressor Fan Resistnece Humidifier Inches Inches kg
CPCO-17 17.0 4.8 2 5,000 1,300 1,800 490 0.96 6.5 1.8 4.5 2.3 5/8” x 1/32” 5/8” x 1/32” 250
CPCO-35 38.0 10.8 3 9,000 1,900 1,800 490 0.91 14.1 2.7 4.5 2.3 3/4” x 1/32” 1.3/8” x 1/32” 350
1. Sensible cooling capacity with condensation temperature at 45°C, air return temperature at 24°C and 45% relative humidity.
2. Resistance and humidifier power shall be considered only for units that include relative humidity and air heating control.
3. SHR (Sensitive Heat Ratio) or FCS (Sensitive Heat Factor). The best energy efficiency is indicated by values next to 1.0 in this coefficient.
60
CPM Mini Precision Air Conditioner
Condenser
Conditioner
CPM-7 7.0 2.0 2,400 7,500 800 x 1.100 x 500 670 x 670 x 710 1.0 3.2
1. Cooling capability through sensible heat, with room temperature at 45°C, air return temperature at 32°C and 30% RH.
2. SHR (Sensible Heat Ratio) is an energy efficiency indicator The closer to 1.0 the better.
3. Active power with the conditioner / condenser set operating at full capacity.
The reliability and durability of products of the automobile and electric appliance sector, among others, should
be confirmed before being placed in the market. The possibility of repeating tests accurately, according to strict
standards, is a requirement easily met by Mecalor's climatic chambers.
Cyclic tests
Programming of temperature/humidity ramps and levels.
Vibration
A amostra montada em um shaker é submetida a ensaios climáticos.
Energy efficiency
Calorimeter testing to determine PROCEL seal class.
Solar radiation
UV Tests to evaluate the combined effect of solar radiation and a variety of climates.
64
Airbag Testing
Climatic Tests 65
Temperature and Humidity
66
Climatic Tests 67
Walk-in Chambers
Tray for cables or devices in single block diagram or mounted at the installation site
Operation of -70°C to 150°C, with relative humidity control
Stainless steel internal finishing
Displays with multiple glasses
Access Ramp
68
Climatic Tests 69
Thermal Shock Tests
The time of stay, transfer speed and number of cycles can be scheduled.
The test component moves between a cold compartment and a hot compartment
Possible use of one of the compartments as an independent chamber
Temperature and humidity control within the range of -70°C to 180°°C
Special internal dimensions
Cable tray
-70°C 180°C
70
Vibration Tests
Designed to operate with the shaker purchased by the customer or as a normal climatic chamber
Specified amplitude and duration combined with climatic conditions of temperature and humidity
Customer defines the conditions to which the test body is to be submitted
Shaker
Climatic Tests 71
Thermal Comfort in Aircrafts
WATER OUTLET
WATER INLET
DRAIN Water
Replacement
LINER TEMPERATURE
CONDITIONING SYSTEM DOGASPER TEMPERATURE AND
HUMIDITY CONDITIONING SYSTEM REMOTE CONDENSER
72
Climatic Tests 73
Water Spray Test
74
Explosion Tests
Tests under controlled extreme temperature, pressure, flow, vibration and pulse conditions of up to 150 bar of pressure
Parameters can be simulated in chambers built to operate in classified explosion-proof areas.
Climatic Tests 75
Engine Testing
Admission air flow with pressure, flow, temperature and humidity maintained precisely constant
Possibility of simulating altitudes and the rapid response in tests with acceleration and deceleration cycles
BYPASS
76
Thermal Shock Tests
for Radiators
Climatic Tests 77
Automotive Air Conditioning Tests
Customized tests for car air conditioning, including air conditioner, heater and radiator
Control of temperature, humidity, flow and air pressure, as well as cooling fluid
Electric Fans
Hot Air System
Air Diffuser
Condenser
Compressor
Accumulator-Drier Filter
Evaporator Box
Control Panel Evaporator
Aerothermal Test
Bench
78
Solar Radiation Simulation
The resulting thermal load from the heating of frame and glasses, and the inner side of the vehicle too, will
affect its performance. Additionally, high temperatures and the light spectrum distribution can shorten the
lifetime of plastic and painted parts. Solar panels provided by Mecalor can be equipped with infrared lamps (for
radiation heating only) or metal halide ones (for sunlight-like spectrum).
Climatic Tests 79
Vehicle Performance Tests
Performance tests to determine power, torque, consumption and compliance with pollution standards (emission
tests) are performed in chambers, foreseeing the vehicle's thermal load in operation, along with air replacement
and exhaustion of gases. A similar situation occurs in durability tests, with the vehicle mounted on hydraulic
pistons, which simulate road conditions. A simulation of sunlight and rain can be incorporated to the chamber
design.
80
Climatic Tests 81
Air Measurement Chambers
Accurate measurements of flow rates and dry bulb / wet bulb temperatures allow determining the cooling
capacity of evaporators in air conditioning devices, drawing the characteristic curve of fans and performing
tightness tests in vehicles. The end-mounted fan compensates load loss in the tunnel automatically.
82
Appliance Tests
Climatic Tests 83
Complete solution with
equipments and
hydraulic installation
Integrated
Projects
Integrated Projects
Quality equipment can have its operation
impaired with the incorrect installation.
86
After Sales
Services
PIT
STOP
As f as t as y ou need
Internal Team
Mobile Workshop
Field Technicians
90
Safety. Tranquility. Quality
Costumer Satisfaction
The average grade achieved
Market Leader
in the last months it was 9.1 + 20.000 chillers in
operation around the world
Preços
Melhor custo
benefício do mercado
brand!
Any technical information included in this catalog
may be changed without previous notice.
Printed in 2019.
Portuguese version
Versión en español
HEADQUARTERS
vendas@mecalor.com
+55 11 2188 1700
Rua da Banduíra, 219 - São Paulo | SP
BRANCH
contacto@mecalor.com
Carretera Estatal 431, Km 1+300, Ejido El Colorado,
El Marqués Conjunto PkCo, Bodega 30 Norte,
C.P 76246 . Querétaro, Qro. México
www.mecalor.com