• Up to 16 outputs

• Voltages up to 48V, Current up to 300A


• Fast-on output connection
• Worldwide approvals & CB report
• Medical Approval Option
• 3 Year Warranty

Key Market Segments & Applications


Instrumentation Broadcast

Alpha Series Medical


Automation
ATE
Industrial Computing
400, 600, 1000 and 1500W Security Lifesciences/Laboratory
AC/DC Modular Network Servers and Routers

Features and Benefits


Features Benefits
• Low Profile • Simpler to install in system
• Fast-on output terminal • Reduces installation time/errors
• Medical Approval available • Suitable in medical applications

INPUT
Alpha 400 90 - 264Vac
Alpha 600 90 - 264Vac, 160 - 358Vdc
Input Voltage
Alpha 1000 85 - 264Vac, 120 - 360Vdc
Alpha 1500 85 - 264Vac (1000W below 150Vac input)
Input Frequency 47 - 63Hz (440Hz with reduced PFC - consult factory)
Inrush Current <50A at 25°C and 264Vac (cold start)
250Vac HBC Fast Acting (not user accessible)
10A for 400W
Input Fuse
12A for 600W
20A for 1000W and 1500W
Leakage Current 1.1mA max at 264Vac & 63Hz
Lower Leakage Option see configuring guide
Power Factor 0.99 typical

OUTPUT
Voltage / Current See module output table
Turn on Delay 1.5s max at 90Vac (150Vac for Alpha 1500W) & 100% rated output power
Rise Time <50ms to 90% of voltage, monotonic rise above 10%
Turn on Overshoot <5% or 250mV Load type dependant, no overshoot with resistive load
Efficiency 75% typical at 230Vac & 100% rated power, config dependent
at 90Vac & 100% rated output power
Hold up 15ms min
13ms for 1000W, 8ms for 1500W and at 207Vac for 1500W
Ripple & Noise <2% (or 100mV if greater) Pk- Pk, using EIAJ test method & 20MHz bandwidth
Voltage Accuracy <1% of set Voltage
Remote Sense Yes Standard on single output modules
Minimum Load No on any output
Temperature Coefficient <0.02% of rated voltage per °C
Load Regulation <0.5% or 25mV for 0-100% load change (with sense connected, <2% without)
Line Regulation <0.5% for 90 - 264Vac input change (210-264Vac for 1500W)
Cross Regulation <0.2% for 100% load change on any other output
<10% of set voltage for 50% load change (above 25% load)
Transient Response Recovery
500µs for recovery to 1% or 100mV of set voltage (1000µs for S module)
Over Voltage Protection Standard for all outputs
Over Current Protection Standard for all outputs
Short Circuit Protection <150% of rated current, when output voltage <1%
Over Temperature Protection Yes Shuts down all outputs. Cycle ac off / on to reset
Note shutdown temp varies according to ambient, output power and input V

Alpha Series 1
SAFETY APPROVALS
Date Amendments Date Amendments
EN 60950-1 2001 IEC 60601-1a 1988 A1, A2
UL 60950-1 2003 UL 60601-1a 2003
CSA22.2 No 60950-1 2003 CSA 60601-1a 2003
IEC60950-1* 2001 CE Mark LV Directive 2006/95/EC (EN60950-1)
* CB Certificate and report available on request a - Only for LL, RL and TL leakage variants. CA400 + CA1000 only

PRODUCT, GENERIC & COLLATERAL STANDARDS


Compliant to High
Low Voltage Power Supply, EMC EN61204-3: 2001 Class A emissions for CA1000 / CA1500
Severity Immunity
Medical Electrical Equipment, EMC EN61601-1-2: 2001 Compliant Class A emissions for CA1000 / CA1500
Immunity for residential, commercial and light
EN61000-6-1: 2001 Compliant
industrial environments
Immunity for industrial environments EN61000-6-2: 2001 Compliant
Emissions for residential, commercial and
EN61000-6-3: 2001 Compliant CA1000 and CA1500 not compliant
light industrial environments
Emissions for industrial environments EN61000-6-4: 2001 Compliant

EMISSIONS
Class B (as per CISPR.22) See application note for details.
Radiated Electric Field EN55022
Class A for Alpha 1000/1500 Only for ‘S’ type leakage versions

Class B (as per CISPR.22) Only for ‘S’ type leakage versions.
Conducted Emissions EN55022
Class A for Alpha 1000/1500 ‘M’ & ‘L’  types meet Class A
Conducted Harmonics EN61000-3-2: 2001 Compliant to Class A
Flicker EN61000-3-3: 1995 + A1:2001 Compliant - dmax only.

IMMUNITY Criteria
Air discharge 15kV
Electrostatic Discharge EN61000-4-2 Level 4 A
Contact discharge 8kV
Electromagnetic Field EN61000-4-3 Level 3 10V/m (tested to 12V/m) A
Input 4kV
Fast / Burst Transient EN61000-4-4 Level 4 Outputs 2kV, A
Tested at 5kHz and 100kHz
Line to Line (Differential) 1.1kV
Surge Immunity EN61000-4-5 Level 3 A
Line to Earth (Common Mode) 2.2kV
Conducted RF Immunity EN61000-4-6 Level 3 10V (tested to 12V) A
Power Frequency Magnetic Field EN61000-4-8 Level 4 30A Continuous A
A
Voltage Dips, Variation, Interruptions EN61000-4-11 Class 3
B for 5s interruptions

Voltage Fluctuations EN61000-4-14 Class 3 For 100 to 240V nominal A

ENVIRONMENT
Temperature 0°C to 70°C operational, -40° to 85°C storage (max 12 months)
Derating 50°C to 70°C derate each output by 2.5% per °C
Low Temperature Start-up -20°C
Humidity 5-95% RH non condensing
Shock 3000 shocks, each of 10g (16ms) half sine
Vibration 10 - 200Hz @ 1.5g
Altitude 3,000 metres operational (15,000 metres non operational)
Pollution Degree 2, Material group 3
IP Rating IP 10

ISOLATION
Input to Output Reinforced 4.3 kV (dc) Output to Earth Operational 500 V (dc)
Input to Earth Basic 2.3 kV (dc) Output to Output Operational 500 V (dc)

2 Alpha Series
OUTPUT VOLTAGES (single output modules) (twin output modules)
Adjustment V1 Adjustment V2 Adjustment
Amps Slots Module Amps Amps Slots
Module Range (Volts) Range (Volts) Range (Volts)
A 4.5 - 5.5 60 2 E 5 - 16 8 5 - 16 8 1
AA 4.5 - 6.5 60 2 EB 4.5 - 5.5 9 4.5 - 5.5 9 1
B 4.5 - 5.5 25 1 EQ 4.5 - 5.5 9 2.7 - 3.9 9 1
BB 4.5 - 6.5 25 1 H 18 - 32 5 18 - 32 5 1
C 5 - 16 16a 1 P 18 - 29 5 5 - 16 8 1
D 18 - 29 8 1
F 9 - 16 33 2
G 17.5 - 29 25b 2
J 30 - 48 10c 2
K 18 - 29 15 2
L 1.8 - 3.2 25 1
M 5 - 16 8 1
N 18 - 32 5d 1
Q 2.7 - 3.9 25 1
R 2.7 - 3.9 60 2
S 2.5 - 5.7 85 2
T 1.8 - 3.2 60 2
a) 12A max above 12V
U 10 - 21 16 1
b) 21A max above 24.5V
W 4.5 - 5.5 15 1 c) Derate output current by 0.25A / V above 40V
Z 4.5 - 5.5 25 1 d) 1A max above 29V

Alpha Configuring Guide

The extensive range of output modules and options make it possible to achieve many combinations of Volts and Amps. To achieve the opti-
mum configuration, please contact our sales office. However you can also create your own configuration from this datasheet by using the
guide below.
Configuring from Datasheet
1 Calculate total output power to determine Alpha 400W, 600W, 1000W or 1500W and select converter, then select required Cooling and
Leakage Current from the following table:-

CA 400 QF LL

400 (5 slots)
Output 600 (5 slots)
Power 1000 (7 slots) empty Standard 1.1 mA
1500 (8 slots) Earth Leakage ML 500µA
Current LL 240µA
empty Forward air - Standard (at 264Vac, 63Hz) RL 110µA
Cooling QFa Forward air - Quiet fan
TL 50µA
RAb Reverse air
Notes:
a) CA400/600 only. CA400 derates to 300W, CA600 derates to 475W
b) Contact sales office for details

2 Select Output Modules and Options from the Output Voltages tables.
Example - if you require 5.2V / 18A with output inhibit : -
a) select B as closest match for voltage and current and prefix with voltage (e.g. 5.2B)
b) add suffix for option (if required)
‘_PA’ for parallel/current share (for N+1 redundant applications)
‘_PP’ for parallel (increase current from one PSU)
‘_IN’ for inhibit
‘_RP’ for remote programming
‘_MF’ (only applicable on 1st module) for global inhibit, ac fail and 5V/50mA standby supply
c) repeat for other outputs
Ensure that the total width of all selected modules is within the slots for the chosen converter. For example:-
CA600LL 5A 12/12E 24D which represents a four output 600W Alpha with Forward air, 240µA Earth Leakage, with:-
Output 1 =   5V / 60A with remote sense
Output 2 = 12V /  8A
Output 3 = 12V /  8A
Output 4 = 24V /  8A with remote sense
3 Contact TDK-Lambda to validate configuration and issue a part number.

Alpha Series 3
Option Connections
4 1 1 slot, 2 output 1 slot, 1 output 2 slot, 1 output
5 2 IN, PA,
6 3
PP, RP + +
Option +

-
- -

Pin IN option PA option PP option RP option MF option


1 n/c + Sense + Sense + Sense Inhibit (low) + 6

MF option
+
2 Module Good Module Good n/c - Sense 5V supply - 5
4
Remote sense
3 Inhibit Star point n/c Control 2 Power Fail
3
- + 2
-
4 n/c - Sense - Sense n/c 0V
1

5 - Power - Power n/c Control 1 Inhibit (high)


6 - Power Star point n/c n/c n/c

Alpha 400

Alpha 600

4 Alpha Series
Alpha 1000

Alpha 1500

Alpha Series 5
   %%%# 

  !     #


& *+7 +1').+7 /3-71+= :+39+
 42+8>1+.'8+1 1,6')42(+
  +7 #1/7 +:43 %
!
6'3)+ #3/8+* /3-*42
"+1 

    "+1     
'< 

    '<       
,6'3)+,68*01'2(*')42 54;+674198/437908*01'2(*')42
;;;,68*01'2(*')42 ;;;908*01'2(*')42
8'1= !'1+7 ,,/)+
$/' *+/ ':46'846/  
   #
 /3/7+114 '17'24  /((98>
8'1= /:'8 '7.147.' 
"+1 
   

76'+1
'< 
      "+1  


/3,4/8'1/'/88*01'2(*')42 '<  
 
;;;/88*01'2(*')42 /3,43+2/))4/1
;;;3+2/))4/1
 
!&

'6141*!86'77+  $""
 ).+63 "+).3/)'1 !955468
+62'3= !8 +8+67(96-
"+1      "+1    

'<      !'1+7


/3,4-+62'3=*+8*01'2(*')42 47)4;
;;;*+8*01'2(*')42 "+1     

/3,48*01'2(*'69
;;;8*01'2(*'69

9786/' !'1+7 ,,/)+


6+*786'77+
+4(+67*46,
9786/'
"+1 

'< 

/3,4-+62'3=*+8*01'2(*')42
;;;*+8*01'2(*')42

    

Document number 69698 - Rev 4.3 - Jan 11

6 Alpha Series

You might also like