Scotch Marine Boilers
Engineered Solutions For HVAC,
Laundry & Drycleaning, Commercial
& Industrial Applications
a
Taree,
10 HP to 200 HP
Steam or Hot Water
Low or High Pressure
Gas, Oil, Dual Fuel, or Low-NOx
Safe + Sure + SimpleLattner Scotch Marine Steam Boile:
Premium Quality 3 Pass DBS Series
Standard equipment includes:
lm Rugged dry back series constructed in accordance
with ASME Pressure Vessel Code and registered with
the National Board.
Generous 5 square feet of heating surface per boiler
horsepower.
1 Thick tube sheet with 2%" diameter tubes. Tubes are
‘welded on second pass.
1 Corrugated furnace included on units 100 horsepower
and larger.
'™ Davited doors on boilers 60 horsepower and larger.
912" x 16" manway on boilers 80 horsepower and larger.
Removable painted jacket with minimum of 2 inch, 8
pound density, fiberglass insulation.
IH ASME stamped safety valve(s) sized in accordance
with ASME Pressure Vessel Code.
1 Flanged stack outlet with thermometer.
1 Float type primary low water cut-off and pump control
Probe type auxiliary low water cut-off with manual
reset.
lm Water gauge glass assembly and water column blow:
down valves.
lm Pressure controls for mit, burner control, and excess
steam pressure with manual reset.
Natural gas, LP gas, #2 oil, dual fuel, or low-NOx
burner.
18 Full modulation burners on boilers 60 horsepower
and larger.
ENEMA 1 bumer control and electrical service panels
1 120 volt step-down control transformer for 3 phase
burners.
'® Solid state flame safeguard control. Includes ultraviolet
sensor with LED fault and run code indicator.
Corrugated Furnace
oor Acoeos
Boer
Steam Out
Manway
Stack Connection
Steam Space
PALL Fron access
= boors
fe 314 Pass
Te 2nd Pass
=
fst Pass,
ae
Furnace Azcote Door
~
3 Pass Heat Transfer
Boles Base Frame
Optional Features:
Insurance code compliance including GE GAP
(formeriy IRI), FM, & Kemper.
ASME Pressure Vessel Code piping package with P6
cata report.
lm Surface skimmer with automatic timer or conductivity
blow-off controls.
Night set back controls.
™ Lead lag boiler sequencing controls.
I TEFC blower motors.
1H Variable CAM, fucliair ratio adjustment equipment.
Additional alarms (specify)
'™ Custom boller feed systems, control packages,
and blowdown separators.
Current DBS Users:
lm Nordstroms Department Stores (California)
1m Evans Garment Restoration (ttinois)
Argonne National Laboratories (Iinois)
Andes Candies (Wisconsin)
m Ramada Hotels (Qatar)Lattner Scotch Marine Hot Water Boilers
Premium Quality 3 Pass DBW Series
Standard equipment includes:
m Rugged dry back series constructed in accordance with
ASME Pressure Vessel Code and registered with the
National Board
Generous 5 square feet of heating surface per boiler
horsepower.
|B Thick tube sheet with 2% diameter tubes. Tubes are
welded on Second pass.
Corrugated furnace included on units 100 horsepower
and larger.
'™ Davited doors on boilers 60 horsepower and larger.
12" x 16" manway on boilers 80 horsepower and
larger.
lm Removable painted jacket with minimum of 2 inch, 8
ound density fiberglass insulation
ASME stamped safety valve(s) sized in accordance
with ASME Pressure Vessel Code.
lm Flanged stack outlet with thermometer.
m Probe type primary low water cut-off
Temperature controls for limit, burner control, excess
temperature with manual resat, and low fire hold
| Combination tomporature/prossure gauge.
Natural gas, LP gas, #2 oil, dual fuel, or low-NOx
burner.
15 Full modulation burners on boilers 60 horsepower
and larger.
ENEMA 1 burner control and electrical service panels.
'® 120 volt step-down control transformer for 3 phase
burners.
® Solid state flame saleguard control with ultraviolet sen-
sor with LED fault and run code indicator.
Concentric Furnace Design
Davited Front Doors
Optional Features:
1 Insurance code compliance including GE GAP
(formerly IR), FM, & Kemper.
Surface skimmer with automatic timer or conductivity
biow-off controls,
1m Temperature set back controls
B Lead lag boilor coquencing controls
1B TEFC blower motors.
1 Variable CAM, fuel/air ratio adjustment equipment
Additional alarms (specity)
Current DBS Users:
18 Monrovia Nurseries (Calfornia)
1B Naval Surface Warfaro Contor (Indiana)
1 Naval and Marine Corps Reserve Center (Alabama)
8 Olympic Wood Products (Washington)
'™ Private Gardens Greenhouses (Belgium)Lattner Expanded Product Line
Single Source All Your Steam & Hot Water Boiler Equipment
Complete Packages:
= Gas, Oil, Dual Fuel, or
Low-NOx
® Electric Boilers
im Feedwater/Condensate
Return Systems
® Blowdown Separators
m= Water Softeners
= Chemical Feed Systems
™ Custom Skid Designs
= And More..
ASME
National Board & UL
To receive a FREE CD
with 1000s of sample
specifications,
CALL TOLL FREE
800-345-1527
JATINER
Latiner Boiler Manufacturing Co.
1411 oth St. SW
Cedar Rapids, 1A 52404
319-366-0778
800-345-1527
Fax: 319-366-0770
info @ latinerboiler.com
www.lattnerboiler.com
Vertical Tubeless
WLF Boilers:
VILE serios steam boilers, 8
‘2e2: 95 0 60 HP.4 pase
high ettciency. Compact ana
feliabie: Natural and LP gas
ULListes
Vertical Tubeless
HE. Boilers
HE. series steam boiler,
B sizes. 1.5 20 HP.
[Atmospheric burners. com-
pact dosign. Natural and
LP aa.
Horizontal Firetube
HRT Boile:
HAT cores steam boilers,
up to OO HP Extra dry
steam, Avaliable with
stmosphric and ercod
oralt burners
Cabinet Series
Electric Steam &
Hot Water Boilers
Catinot sovoe oleic
steam and hot water bolers.
lp to 3600 KW. Custom con
figurations and multple vel
age optons UL listed
‘Space Saver
Hot Water Boilers
‘Space Saver series elect
ot water boilers, up 10 165,
KW. Comoset 2 x2 t x4
ff Sutablo for closet nstala,
tors. ULUSted.
Electric Steam
Boilers
Horieortal seriee elactric
sieam voters. upto 148 KV.
Higi ard low pressure, mul
tiple voltage eptione, oacy:
Complete Skid
Packages
Complete skid packages
Including mrourting, wine,
‘and piping of boles and
Felatea equipment. Single
pont comections optional
Blowdown Separators
& Automatic
Aftercooler
lowdown
‘separators for
reduction ot steam|
pressuo and
feflventtemporatare
‘Automatic contol and
attereoolers opional
Condensate Return
Systems
‘Staridard and custom con
densate returns including
‘ieyplo, dupior, and trpox
systems, Conia ang pre-
heating options avaiable,Lattner Boiler Company
HOT WATER
SCOTCH MARINE HOT WATER BOILERS
25THRU 300 B.H.P. + 5 SQ.FT/ BHP.
DIMENSIONAL DATA
3-PASS DESIGN
30 TO 160 PSIG
HOT WATER
[ss [ ora [ esos
| OVAL TOE wea
[seo et [asf or
| sume eae ee
[Ree SH TERS nla _|-a |= | | ww
OTS HES
ee over =o zeae ee ae
I] Boek eTOOUTSOEL WES Bes [ses seas aie ais ae
[900 =r sopaspas pase > «| «>
[ies meres
ee wae wpe pease
i] To nor WATER CoECTON i a
N_[Toomamoomer ws s_[ ws] es | os a
| TOBURNEN CENTERLINE aos as ass os ss a
CLEARANCES APRON
S| TORE uses Fron) See eee
1 [To omeN es ROK ope esses as
UT roreveve 105s Ree) [os va
| Toren DOOR REA) i A i
Wo] Tosser Doom Sz) a as [ee 77
1 [Toren REA OR SE] ees [a =
TSCAL DENSON, CHES
18 | CMETER FERAL RET a
e_-FuRice nse DANE TER aoe 8 olen at
1 WoTHOF uke OTE = [ar
FE SDK OFT COWETER BO] fw fa | lw
TE SoHE OUTLET CEA SE ae eee
esas
| WATER RETURN CORECTIN mean ene ae [one [a
TD WATER CUTE COMES aa] —3—] 4] +P shia | se srie- | sie | ore
(onan rf cei eee eee ae g
| REEF aes mag os posed
5 ever wave
AT WATER RETR aaa aaa
Ta .ooaon WATER OUTLET eats
[TiN A ew ao oe oe [zo
[cs ari REEF VALE es a a a
“3 | LooaTow RELEF VANE 1
‘Specteatons Sujet to Change Waout Notee
‘ule No, OS 121.97
1411 Ninth Street SW * P.O. Box 1527 + Cedar Rapids, lowa 52406 USA
Tel: 319-986-0778 + Toll Free: 800-345-1627 + Fax: 319-366-0770 + e-mail latiner@aol.comLattner Boiler Company
STEAM
SCOTCH MARINE STEAM BOILERS
30 THRU 300 BHI
+ SSQFT/BHP.
DIMENSIONAL DATA
3-PASS DESIGN
15 To 150 PSIG
STEAM
cm aa a
| STEAM OUTPUT. ae gai was [io [ars [aro aren | ae [este sits_| oo] 608
HEATING SURFACE soft 200900 | a0 | 200 [ao] os sr [oro oa
‘WATER CONTENT, aaa rear a as asa ||
SHIPPNG WEIGHT WELDER sr [sen [sco | stn 500 [roe | sno | aco | zoo zr
x =
3 aes [zoe aaa] aes [aot [ as [at faa
ig Heo] eats ore] 2s |
0 Spe [tos toe fee tor] tes os |e |r
e ates [se papa ete Ps se
— abet e as tt | tt
S “ a
Laon +++ ae
A | Sve Sete pepe aa =a
I —| tole Umass sate pe pss [6 | 6 2 | 64
«ae ee ee aaa ase
THEGHTS nae —_—
tT Oot i ae
i Tose oi epee [| =| |e | s_ | is
H—[Tobion own oa Sc i
2 [Teena cat [ce ca
[ote ore spepete pe, s**t @
R—[ ose cere apis se ee 55
CLEARANCES no
S| Todaw be on ae eee a =
1 | Yoepen eo tn) [as op -2 | 2 |e, a
Tow ate [70 Cs i a
| Tospe om. apa a a a
W | Tope sr ete [sr] | | a 7
| Tope war duo ape en a a oa
DENSIONS ine
7 | Nara we om See es ee 7
‘| anwirowelpeht a %
‘oo | Fross sonar( sata a a ca
Fe | Sm oat aa oe eee (am
Fiz Stl ton fesleem ase e |r) erera 3
"VALVE CONNECTION SIZES Te
| Fei Tae ee oe eee Tie
| Siam te Spe = or
| Bw om. oa a z
a Sa ae, 1p rupee tia [2 [2 fea a | 3 z
‘esate 1550 z
3 | Sim at 150 Ze ee
“2 Bow dom, ps Tee
‘Saya, Sp Sea nz [a fr cer
| Say ae 1p ei ar ger eg
13 | Sim ati ester eee ar
te | Bordo cian eet apap aa at a |e |
LA _| Sua becom aon ooo [we et te
Le | Sir com eon eel ee ee ee a
‘Specteaton Sbjct to Change Wihout Netce ‘Buln No, DS2-