(4) Remove interior furnishings and carpeting as required to gain access to floorboards being
removed.
(5) Remove floor heater mats, if installed. See Supplemental Heating - Removal / Installation,
25-27-00, Removal / Installation or Code 252070.
(6) Gain access to thermal switch by removing the following access covers and / or floorboards
as required (see Figure 501 and Figure 502):
NOTE: The table provides the standard production location of the overheat thermal
switches. The switches may have been relocated during aircraft outfitting to monitor
additional equipment.
THERMAL
SWITCH ACCESS PANEL /
LOCATION REF DES FLOORBOARD
LEER 056S4 223AZ
LEER 056S5 223AZ
LEER 056S6 223AZ
REER 056S20 224AZ
26-14-01
Page 501
June 15/16
MAINTENANCE MANUAL
THERMAL
SWITCH ACCESS PANEL /
LOCATION REF DES FLOORBOARD
REER 056S21 224AZ
Forward floor 056S24 1C
Forward floor 056S25 3C
Forward floor 056S26 3C
Forward floor 056S30 4C
Forward floor 056S31 5C
Baggage EER 056S8 Baggage EER
Baggage EER 056S9 Baggage EER
(7) Apply electrical power to aircraft. See External Electrical Power Application, 20-20-10,
Maintenance Practices.
(8) On MFD DISPLAY SWITCHING and DISPLAY SYSTEM CONTROL panels, select all
switches to NORM.
B. Procedure
NOTE: The switches close at approximately 150° ±5°F (65° ±5°C) and open at approximately
135° ±5°F (57° ±5°C).
(1) Select and hold EQPT OVHT switch.
NOTE: The EQPT OVHT switch is located in the SYSTEM TEST section of the cockpit
overhead panel.
(2) Verify the following messages are displayed on CAS:
(a) L Pylon Hot (red)
(b) R Pylon Hot (red)
(c) L Aft Floor Hot (red)
(d) C Aft Floor Hot (red)
(e) R Aft Floor Hot (red)
(f) Aft Equipment Hot (red)
(3) Release EQPT OVHT switch.
CAUTION: EXTREME CARE SHOULD BE USED WHEN USING THE HEAT GUN.
EXCESSIVE HEAT COULD DAMAGE THE SWITCHES.
(4) Using heat gun, heat applicable thermal switch until switch closes, then verify switch trip point
using thermometer. Remove heat source as soon as switch closes.
NOTE: If switch is not operating within range, ensure to verify part number with IPC before
replacing.
(5) Verify applicable message is displayed on CAS. See Table 501.
26-14-01
Page 502
June 15/16
MAINTENANCE MANUAL
(6) Pull applicable circuit breaker and verify message is no longer displayed on CAS. See Table
501.
C. Follow On
(1) Depress circuit breaker pulled in Step 1.B.(6).
(2) On MFD DISPLAY SWITCHING and DISPLAY SYSTEM CONTROL panels, select all
switches to post flight position.
(3) Remove electrical power from aircraft. See External Electrical Power Application, 20-20-10,
Maintenance Practices.
(4) Inspect for presence of foreign objects.
(5) If floorboard was removed in Step 1.A.(6), perform Floorboard Clip Nut - Check, 53-00-00,
Inspection / Check or Code 530027.
(6) Perform Open / Close - Checks, 20-00-00, Maintenance Practices.
(7) Install access panels and / or floorboards removed in Step 1.A.(6).
(8) Install floor heater mats removed in Step 1.A.(5). See Supplemental Heating - Removal /
Installation, 25-27-00, Removal / Installation or Code 252070.
(9) Install carpeting and interior furnishings removed in Step 1.A.(4).
(10) Record all maintenance actions in accordance with current governing authority.
26-14-01
Page 503
June 15/16
MAINTENANCE MANUAL
26-14-01
Page 504
June 15/16
MAINTENANCE MANUAL
224AZ
224BZ
223AZ
31800F00
26-14-01
Page 505
June 15/16
MAINTENANCE MANUAL
FS FS FS
145 229 426
ZONE 122 ZONE 124
2D 3E 4E 5E 7E 8E
6E
1D 2C 3D 4D 8D
5D 6D 7D
1E
1C 3C 4C 5C 7C 8C
1G 2B 6C
1B 3B 4B 5B 6B 7B 8B
1F 2A 3A 4A
1A 5A 6A 7A 8A
6A-1 8A-1
31367F00
26-14-01
Page 506
June 15/16
MAINTENANCE MANUAL
(4) Remove interior furnishings and carpeting as required to gain access to floorboards being
removed.
(5) Remove floor heater mats, if installed. See Supplemental Heating - Removal / Installation,
25-27-00, Removal / Installation or Code 252070.
(6) Gain access to applicable thermal switch by removing the following floorboards as required
(see Figure 503):
NOTE: The table provides the standard production location of the overheat thermal
switches. The switches may have been relocated during aircraft outfitting to monitor
additional equipment.
THERMAL
SWITCH ACCESS PANEL /
LOCATION REF DES FLOORBOARD
Left aft floor 056S12 14E
Left aft floor 056S13 14B
Left aft floor 056S14 14H
Center aft floor 056S15 14A
26-14-01
Page 507
June 15/16
MAINTENANCE MANUAL
THERMAL
SWITCH ACCESS PANEL /
LOCATION REF DES FLOORBOARD
Center aft floor 056S16 14E
Right aft floor 056S27 14J
Right aft floor 056S28 14E
Right aft floor 056S29 14C
(7) Apply electrical power to aircraft. See External Electrical Power Application, 20-20-10,
Maintenance Practices.
(8) On MFD DISPLAY SWITCHING and DISPLAY SYSTEM CONTROL panels, select all
switches to NORM.
B. Procedure
NOTE: The switches close at approximateley 250° ±5°F (121° ±5°C) and open at approximately
235° ±5°F (112° ±5°C).
(1) Select and hold EQPT OVHT switch.
NOTE: The EQPT OVHT switch is located in the SYSTEM TEST section of the cockpit
overhead panel.
(2) Verify the following messages are displayed on CAS:
(a) L Pylon Hot (red)
(b) R Pylon Hot (red)
(c) L Aft Floor Hot (red)
(d) C Aft Floor Hot (red)
(e) R Aft Floor Hot (red)
(f) Aft Equipment Hot (red)
(3) Release EQPT OVHT switch.
CAUTION: EXTREME CARE SHOULD BE TAKEN WHEN USING THE HEAT GUN.
EXCESSIVE HEAT COULD DAMAGE THE SWITCHES.
(4) Using heat gun, heat applicable thermal switch until switch closes, then verify switch trip point
using thermometer. Remove heat source as soon as switch closes.
NOTE: If switch is not operating within range, ensure to verify part number with IPC before
replacing.
(5) Verify applicable message is displayed on CAS. See Table 502.
(6) Pull applicable circuit breaker and verify message is no longer displayed on CAS. See Table
502.
C. Follow On
(1) Depress circuit breaker pulled in Step 2.B.(6).
26-14-01
Page 508
June 15/16
MAINTENANCE MANUAL
(2) On MFD DISPLAY SWITCHING and DISPLAY SYSTEM CONTROL panels, select all
switches to OFF.
(3) Remove electrical power from aircraft. See External Electrical Power Application, 20-20-10,
Maintenance Practices.
(4) Inspect for presence of foreign objects.
(5) Perform Floorboard Clip Nut - Check, 53-00-00, Inspection / Check or Code 530027.
(6) Perform Open / Close - Checks, 20-00-00, Maintenance Practices.
(7) Install floorboards removed in Step 2.A.(6).
(8) Install floor heater mats removed in Step 2.A.(5). See Supplemental Heating - Removal /
Installation, 25-27-00, Removal / Installation or Code 252070.
(9) Install carpeting and interior furnishings removed in Step 2.A.(4).
(10) Record all maintenance actions in accordance with current governing authority.
26-14-01
Page 509
June 15/16
MAINTENANCE MANUAL
FS FS FS
632 684 758
14D 14K
12E 13E
14A 14C
12B 13B
14H
14B
12A 13A
FS FS FS
632 684 758
37272F01
26-14-01
Page 510
June 15/16
MAINTENANCE MANUAL
26-14-01
Page 511
June 15/16
MAINTENANCE MANUAL
26-14-01
Page 512
June 15/16