EQUIPMENT OVERHEAT THERMAL SWITCHES — ADJUSTMENT / TEST


1. Equipment Overheat Thermal Switch — Operational Test
A. Preparation
SPECIAL TOOLS AND TEST EQUIPMENT
Heat gun ................................................................................................ GSE5100473 or equivalent
Thermometer .......................................................................................... GSE5100456 or equivalent
Thermometer .......................................................................................... GSE5100516 or equivalent
NOTE: Either thermometer may be used to check the trip point of the thermal switches.
(1) Reference
• Safe Ground Maintenance Procedure, 20-00-00, Maintenance Practices
• Open / Close - Checks, 20-00-00, Maintenance Practices
• External Electrical Power Application, 20-20-10, Maintenance Practices
• Supplemental Heating - Removal / Installation, 25-27-00, Removal / Installation or
Code 252070
• Floorboard Clip Nut - Check, 53-00-00, Inspection / Check or Code 530027
(2) Aircraft Preparation
(a) Prepare aircraft for safe ground maintenance. See Safe Ground Maintenance
Procedure, 20-00-00, Maintenance Practices.
(3) Ensure the following Circuit Breakers (CB) are depressed:

CB NAME CB PANEL CB LOCATION


WARN LTS PWR #2 LEER WARN TONES / LTS
WARN LTS PWR #1 REER WARN TONES / LTS

(4) Remove interior furnishings and carpeting as required to gain access to floorboards being
removed.
(5) Remove floor heater mats, if installed. See Supplemental Heating - Removal / Installation,
25-27-00, Removal / Installation or Code 252070.
(6) Gain access to thermal switch by removing the following access covers and / or floorboards
as required (see Figure 501 and Figure 502):
NOTE: The table provides the standard production location of the overheat thermal
switches. The switches may have been relocated during aircraft outfitting to monitor
additional equipment.

THERMAL
SWITCH ACCESS PANEL /
LOCATION REF DES FLOORBOARD
LEER 056S4 223AZ
LEER 056S5 223AZ
LEER 056S6 223AZ
REER 056S20 224AZ

26-14-01
Page 501
June 15/16
MAINTENANCE MANUAL

THERMAL
SWITCH ACCESS PANEL /
LOCATION REF DES FLOORBOARD
REER 056S21 224AZ
Forward floor 056S24 1C
Forward floor 056S25 3C
Forward floor 056S26 3C
Forward floor 056S30 4C
Forward floor 056S31 5C
Baggage EER 056S8 Baggage EER
Baggage EER 056S9 Baggage EER

(7) Apply electrical power to aircraft. See External Electrical Power Application, 20-20-10,
Maintenance Practices.
(8) On MFD DISPLAY SWITCHING and DISPLAY SYSTEM CONTROL panels, select all
switches to NORM.
B. Procedure
NOTE: The switches close at approximately 150° ±5°F (65° ±5°C) and open at approximately
135° ±5°F (57° ±5°C).
(1) Select and hold EQPT OVHT switch.
NOTE: The EQPT OVHT switch is located in the SYSTEM TEST section of the cockpit
overhead panel.
(2) Verify the following messages are displayed on CAS:
(a) L Pylon Hot (red)
(b) R Pylon Hot (red)
(c) L Aft Floor Hot (red)
(d) C Aft Floor Hot (red)
(e) R Aft Floor Hot (red)
(f) Aft Equipment Hot (red)
(3) Release EQPT OVHT switch.
CAUTION: EXTREME CARE SHOULD BE USED WHEN USING THE HEAT GUN.
EXCESSIVE HEAT COULD DAMAGE THE SWITCHES.
(4) Using heat gun, heat applicable thermal switch until switch closes, then verify switch trip point
using thermometer. Remove heat source as soon as switch closes.
NOTE: If switch is not operating within range, ensure to verify part number with IPC before
replacing.
(5) Verify applicable message is displayed on CAS. See Table 501.

26-14-01
Page 502
June 15/16
MAINTENANCE MANUAL

(6) Pull applicable circuit breaker and verify message is no longer displayed on CAS. See Table
501.
C. Follow On
(1) Depress circuit breaker pulled in Step 1.B.(6).
(2) On MFD DISPLAY SWITCHING and DISPLAY SYSTEM CONTROL panels, select all
switches to post flight position.
(3) Remove electrical power from aircraft. See External Electrical Power Application, 20-20-10,
Maintenance Practices.
(4) Inspect for presence of foreign objects.
(5) If floorboard was removed in Step 1.A.(6), perform Floorboard Clip Nut - Check, 53-00-00,
Inspection / Check or Code 530027.
(6) Perform Open / Close - Checks, 20-00-00, Maintenance Practices.
(7) Install access panels and / or floorboards removed in Step 1.A.(6).
(8) Install floor heater mats removed in Step 1.A.(5). See Supplemental Heating - Removal /
Installation, 25-27-00, Removal / Installation or Code 252070.
(9) Install carpeting and interior furnishings removed in Step 1.A.(4).
(10) Record all maintenance actions in accordance with current governing authority.

Table 501: Thermal Switch / CAS Message

THERMAL REF TEMP EICAS


SWITCH DES (°F) LOCATION(1) MESSAGE CIRCUIT BREAKER
LEER 056S4 150 Inboard edge of L EER Hot WARN LTS PWR #2
upper shelf (amber)
056S5 150 Inboard edge of
2nd shelf from
bottom
056S6 150 Outboard edge of
lower shelf, behind
MAU
REER 056S20 150 Inboard edge of R EER Hot WARN LTS PWR #1
upper shelf (amber)
056S21 150 Outboard edge of
2nd shelf from
bottom, behind
TCAS

26-14-01
Page 503
June 15/16
MAINTENANCE MANUAL

THERMAL REF TEMP EICAS


SWITCH DES (°F) LOCATION(1) MESSAGE CIRCUIT BREAKER
Forward floor 056S24 150 FS 133, BL 0, WL Forward Floor WARN LTS PWR #1
60 Area Hot
(amber)
056S25 150 FS 205, RBL 11,
WL 66
056S26 150 FS 229, RBL 12,
WL 61
056S30 150 FS 253, RBL 4,
WL 68
056S31 150 FS 277, RBL 6,
WL 65
Baggage EER 056S8 150 Bottom inboard Baggage EER WARN LTS PWR #2
edge of upper Hot (amber)
shelf, above
FSECU
056S9 150 Side of EER,
behind emergency
battery
(1)
The switch location is the standard production location. The switches may have been relocated during aircraft outfitting
to monitor additional equipment.

26-14-01
Page 504
June 15/16
MAINTENANCE MANUAL

224AZ

224BZ

223AZ

31800F00

Electronic Equipment Rack Access Covers


Figure 501

26-14-01
Page 505
June 15/16
MAINTENANCE MANUAL

FS FS FS
145 229 426
ZONE 122 ZONE 124

1E-1 4D-1 5D-1 6E-1 8E-1

2D 3E 4E 5E 7E 8E
6E
1D 2C 3D 4D 8D
5D 6D 7D
1E
1C 3C 4C 5C 7C 8C
1G 2B 6C

1B 3B 4B 5B 6B 7B 8B
1F 2A 3A 4A
1A 5A 6A 7A 8A

6A-1 8A-1

ZONE 121 ZONE 123


FS FS FS
145 229 426

31367F00

Forward Midcabin Floorboards


Figure 502

26-14-01
Page 506
June 15/16
MAINTENANCE MANUAL

2. Baggage Compartment Below Floor Overheat Thermal Switch — Functional Test


A. Preparation
SPECIAL TOOLS AND TEST EQUIPMENT

Heat gun ................................................................................................ GSE5100473 or equivalent


Power supply ......................................................................................... GSE2400108 or equivalent
Thermometer .......................................................................................... GSE5100456 or equivalent
Thermometer .......................................................................................... GSE5100516 or equivalent
NOTE: Either thermometer may be used to check the trip point of the thermal switches.
(1) References
• Safe Ground Maintenance Procedure, 20-00-00, Maintenance Practices
• Open / Close - Checks, 20-00-00, Maintenance Practices
• External Electrical Power Application, 20-20-10, Maintenance Practices
• Supplemental Heating - Removal / Installation, 25-27-00, Removal / Installation or
Code 252070
• Floorboard Clip Nut - Check, 53-00-00, Inspection / Check or Code 530027
(2) Aircraft Preparation
(a) Prepare aircraft for safe ground maintenance. See Safe Ground Maintenance
Procedure, 20-00-00, Maintenance Practices.
(3) Ensure the following Circuit Breakers (CB) are depressed:

CB NAME CB PANEL CB LOCATION


WARN LTS PWR #2 LEER WARN TONES / LTS
WARN LTS PWR #1 REER WARN TONES / LTS

(4) Remove interior furnishings and carpeting as required to gain access to floorboards being
removed.
(5) Remove floor heater mats, if installed. See Supplemental Heating - Removal / Installation,
25-27-00, Removal / Installation or Code 252070.
(6) Gain access to applicable thermal switch by removing the following floorboards as required
(see Figure 503):
NOTE: The table provides the standard production location of the overheat thermal
switches. The switches may have been relocated during aircraft outfitting to monitor
additional equipment.

THERMAL
SWITCH ACCESS PANEL /
LOCATION REF DES FLOORBOARD
Left aft floor 056S12 14E
Left aft floor 056S13 14B
Left aft floor 056S14 14H
Center aft floor 056S15 14A

26-14-01
Page 507
June 15/16
MAINTENANCE MANUAL

THERMAL
SWITCH ACCESS PANEL /
LOCATION REF DES FLOORBOARD
Center aft floor 056S16 14E
Right aft floor 056S27 14J
Right aft floor 056S28 14E
Right aft floor 056S29 14C

(7) Apply electrical power to aircraft. See External Electrical Power Application, 20-20-10,
Maintenance Practices.
(8) On MFD DISPLAY SWITCHING and DISPLAY SYSTEM CONTROL panels, select all
switches to NORM.
B. Procedure
NOTE: The switches close at approximateley 250° ±5°F (121° ±5°C) and open at approximately
235° ±5°F (112° ±5°C).
(1) Select and hold EQPT OVHT switch.
NOTE: The EQPT OVHT switch is located in the SYSTEM TEST section of the cockpit
overhead panel.
(2) Verify the following messages are displayed on CAS:
(a) L Pylon Hot (red)
(b) R Pylon Hot (red)
(c) L Aft Floor Hot (red)
(d) C Aft Floor Hot (red)
(e) R Aft Floor Hot (red)
(f) Aft Equipment Hot (red)
(3) Release EQPT OVHT switch.
CAUTION: EXTREME CARE SHOULD BE TAKEN WHEN USING THE HEAT GUN.
EXCESSIVE HEAT COULD DAMAGE THE SWITCHES.
(4) Using heat gun, heat applicable thermal switch until switch closes, then verify switch trip point
using thermometer. Remove heat source as soon as switch closes.
NOTE: If switch is not operating within range, ensure to verify part number with IPC before
replacing.
(5) Verify applicable message is displayed on CAS. See Table 502.
(6) Pull applicable circuit breaker and verify message is no longer displayed on CAS. See Table
502.
C. Follow On
(1) Depress circuit breaker pulled in Step 2.B.(6).

26-14-01
Page 508
June 15/16
MAINTENANCE MANUAL

(2) On MFD DISPLAY SWITCHING and DISPLAY SYSTEM CONTROL panels, select all
switches to OFF.
(3) Remove electrical power from aircraft. See External Electrical Power Application, 20-20-10,
Maintenance Practices.
(4) Inspect for presence of foreign objects.
(5) Perform Floorboard Clip Nut - Check, 53-00-00, Inspection / Check or Code 530027.
(6) Perform Open / Close - Checks, 20-00-00, Maintenance Practices.
(7) Install floorboards removed in Step 2.A.(6).
(8) Install floor heater mats removed in Step 2.A.(5). See Supplemental Heating - Removal /
Installation, 25-27-00, Removal / Installation or Code 252070.
(9) Install carpeting and interior furnishings removed in Step 2.A.(4).
(10) Record all maintenance actions in accordance with current governing authority.

Table 502: Thermal Switch / CAS Message

THERMAL REF TEMP EICAS


SWITCH DES (°F) LOCATION(1) MESSAGE CIRCUIT BREAKER
Left aft floor 056S12 250 FS 707, LBL 18 L Aft Floor Hot WARN LTS PWR #2
(red)
056S13 250 FS 733, LBL 14
056S14 250 FS 755, LBL 16
Center aft floor 056S15 250 FS 694, RBL 3 C Aft Floor Hot WARN LTS PWR #2
(red)
Center aft floor 056S16 250 FS 707, RBL 21
Right aft floor 056S27 250 FS 755, RBL 16 R Aft Floor Hot WARN LTS PWR #1
(red)
056S28 250 FS 733, RBL 20
056S29 250 FS 707, LBL 3
(1)
The switch location is the standard production location. The switches may have been relocated during aircraft outfitting
to monitor additional equipment.

26-14-01
Page 509
June 15/16
MAINTENANCE MANUAL

FS FS FS
632 684 758

ZONE 142 ZONE 144

14D 14K
12E 13E

12D 13D 14F


14C-1
14E 14J
12C 13C

14A 14C
12B 13B

14H
14B
12A 13A

ZONE 141 ZONE 143

FS FS FS
632 684 758

37272F01

Aft Midcabin Floorboards


Figure 503

26-14-01
Page 510
June 15/16
MAINTENANCE MANUAL

3. Aft Equipment Overheat Thermal Switches — Functional Test


A. Preparation
SPECIAL TOOLS AND TEST EQUIPMENT

Heat gun ................................................................................................ GSE5100473 or equivalent


Power supply ......................................................................................... GSE2400108 or equivalent
Thermometer .......................................................................................... GSE5100456 or equivalent
Thermometer .......................................................................................... GSE5100516 or equivalent
NOTE: Either thermometer may be used to test the trip point of the thermal switiches.
(1) Reference
• Safe Ground Maintenance Procedure, 20-00-00, Maintenance Practices
• External Electrical Power Application, 20-20-10, Maintenance Practices
(2) Aircraft Preparation
(a) Prepare aircraft for safe ground maintenance. See Safe Ground Maintenance
Procedure, 20-00-00, Maintenance Practices.
(3) Ensure the following Circuit Breakers (CB) are depressed:

CB NAME CB PANEL CB LOCATION


WARN LTS PWR #2 LEER WARN TONES / LTS
WARN LTS PWR #1 REER WARN TONES / LTS

(4) Gain access to tail compartment.


(5) Apply electrical power to aircraft. See External Electrical Power Application, 20-20-10,
Maintenance Practices.
(6) On MFD DISPLAY SWITCHING and DISPLAY SYSTEM CONTROL panels, select all
switches to NORM.
B. Procedure
NOTE: The switches close at approximateley 250° ±5°F (121° ±5°C) and open at approximately
235° ±5°F (112° ±5°C).
(1) Select and hold EQPT OVHT switch.
NOTE: The EQPT OVHT switch is located in the SYSTEM TEST section of the cockpit
overhead panel.
(2) Verify the following messages are displayed on CAS:
(a) L Pylon Hot (red)
(b) R Pylon Hot (red)
(c) L Aft Floor Hot (red)
(d) C Aft Floor Hot (red)
(e) R Aft Floor Hot (red)
(f) Aft Equipment Hot (red)

26-14-01
Page 511
June 15/16
MAINTENANCE MANUAL

(3) Release EQPT OVHT switch.


CAUTION: EXTREME CARE SHOULD BE USED WHEN USING THE HEAT GUN.
EXCESSIVE HEAT COULD DAMAGE THE SWITCHES.
(4) Using heat gun, heat applicable thermal switch until switch closes, then verify switch trip point
using thermometer. Remove heat source as soon as switch closes. See Table 503.
NOTE: If switch is not operating within range, ensure to verify part number with IPC before
replacing.
(5) Verify applicable message is displayed on CAS. See Table 503.
(6) Pull applicable circuit breaker and verify message is no longer displayed on CAS. See Table
503.
C. Follow On
(1) Depress circuit breaker pulled in Step 3.B.(6).
(2) On MFD DISPLAY SWITCHING and DISPLAY SYSTEM CONTROL panels, select all
switches to OFF.
(3) Remove electrical power from aircraft. See External Electrical Power Application, 20-20-10,
Maintenance Practices.
(4) Inspect for presence of foreign objects.
(5) Close access opened in Step 3.A.(4).
(6) Record all maintenance actions in accordance with current governing authority.

Table 503: Thermal Switch / CAS Message

THERMAL REF TEMP EICAS


SWITCH DES (°F) LOCATION(1) MESSAGE CIRCUIT BREAKER
Aft equipment 056S10 250 Upper tail Aft Equipment WARN LTS PWR #2
compartment, FS Hot (red)
838, left stringer 5
056S11 250 Upper tail
compartment, FS
838, right stringer
5
(1)
The switch location is the standard production location. The switches may have been relocated during aircraft outfitting
to monitor additional equipment.

26-14-01
Page 512
June 15/16