You are on page 1of 2

Beam Design Summary

Span ABC

Beam AB (singly reinforced beam)

Location M (kN-m) As required No. and Ast provided


diameter of (mm^2)
bars
Exterior 39.99 551 3 No. 19 852
Negative
Midspan 45 637 3 No. 19 852
Positive
Interior 70 1039 3 No. 22 1161
Negative

Beam BC (singly reinforced beam)

Location M (kN-m) As required No. and Ast provided


diameter of (mm^2)
bars
Exterior 39.99 551 3 No. 19 852
Negative
Midspan 45 637 3 No. 19 852
Positive
Interior 70 1039 3 No. 22 1161
Negative

Span GHI

Beam GH (singly reinforced beam)

Location M (kN-m) As required No. and Ast provided


diameter of (mm^2)
bars
Exterior 36.65 510 3 No. 19 852
Negative
Midspan 41.89 585 3 No. 19 852
Positive
Interior 65.17 978 3 No. 22 1161
Negative

Beam Hi has the same design as beam GH


Span ADG and CFI

Beam AD (singly reinforced beam)

Location M (kN-m) As required No. and Ast provided


diameter of (mm^2)
bars
Exterior 22.80 423 3 No. 19 852
Negative
Midspan 26.06 467 3 No. 19 852
Positive
Interior 40.54 576 3 No. 19 852
Negative

Beam DG and Beam FI has the same design as Beam AD

Span DEF

Beam DE(doubly reinforced beam)

Location M (kN-m) As required No. and Ast provided


diameter of (mm^2)
bars
Exterior 53.02 697 3 no.22 for 1548
Negative tension
3 n0. 19 for
compression
Midspan 60.59 726 3 no.22 for 1548
Positive tension
3 n0. 19 for
compression
Interior 94.25 1343 3 no.22 for 1548
Negative tension
3 n0. 19 for
compression

Beam EF has the same design as Beam DE