Ss (Sus) W + p2 PDF

You might also like

You are on page 1of 1

CAESAR II 2018 Ver.10.00.00.

7700, (Build 170726) Date: AUG 29, 2020 Time: 15:6


Job Name: HAMMER
Licensed To: SPLM: Edit company name in <system>\company.txt
STRESS SUMMARY REPORT: Highest Stresses Mini Statement
CASE 7 (SUS) W+P2

LOAD CASE DEFINITION KEY

CASE 7 (SUS) W+P2

Piping Code: B31.3 = B31.3 -2016, Jan 31, 2017

CODE STRESS CHECK PASSED : LOADCASE 7 (SUS) W+P2

Highest Stresses: ( KPa ) LOADCASE 7 (SUS) W+P2


Ratio (%): 33.3 @Node 5
Code Stress: 34452.2 Allowable Stress: 103421.4
Axial Stress: 10083.2 @Node 30
Bending Stress: 29094.6 @Node 80
Torsion Stress: 696.5 @Node 85
Hoop Stress: 20979.8 @Node 10
Max Stress Intensity: 39189.4 @Node 80

08/29/20 15:12:50 Page 1