the debut GTS-220 Series as the innovative successor to the best selling GTS-210 Series Total Stations. The GTS-210 Series with "Waterproof" design brought revolution to the surveying industry with features and durability. Now the new GTS-220 Series has up-graded its basic functions for distance and angle measurement in addition to GTS-220 series maintaining superb durability against the environment. The GTS-220 Series is also provided with a longer life battery of 10 hours, and various kinds of application programs makes surveying work quick and simple in the field. The features included with the "All Weather" highly productive GTS-220 Series Total Stations are setting a new standard for surveying! <Specification> Model Name GTS-223 GTS-225 GTS-226 GTS-229 TELESCOPE Length 150mm Objective Lens 45mm (EDM 50mm) Diameter Magnification 30 × Image Erect Field of View 1°30′ Resolving Power 2.5″ Minimum Focus 1.3m Distance DISTANCE MEASUREMENT Condition 1 1 prism 3,000m (9,900ft) 2,000m 3 prisms 4,000m (13,200ft) (6,600ft) 9 prisms 5,000m (16,400ft) 2,700m (8,900ft) 3,400m (11,200ft) Condition 2 1 prism 3,500m (11,500ft) 2,300m 3 prisms 4,700m (15,400ft) (7,500ft) 9 prisms 5,800m (19,000ft) 3,100m (10,200ft) 4,000m (13,200ft) Condition Sight haze with visibility about 20 km (12.5 miles) 1: moderate sunlight with light heat shimmer. Condition No haze with visibility about 40 km (25 miles), 2: overcast with no heat shimmer. ±(3mm + Accuracy ±(2mm + 2ppm× D)m.s.e. 3ppm× D)m.s.e. D: Measuring distance (mm) Least Count in Measurement Fine Mode 1mm (0.005 ft.)/0.2mm (0.001 ft.) Coarse Mode 10mm (0.02 ft.)/1mm (0.005 ft.) Tracking Mode 10mm (0.02 ft.) Measurement 11 digits: max. display 9999999.9999 Display Measuring Time Fine Mode 1mm: 1.2sec. (Initial 4 sec.) 0.2mm: 2.8sec. (Initial 5 sec.) Coarse Mode 0.7sec. (Initial 3 sec.) Tracking Mode 0.4sec. (Initial 3 sec.) (The initial time will be different by a condition and setting EDH off time.) Atmospheric -999.9 to +999.9ppm (By 0.1ppm) Correction Range Prism Constant -99.9 to +99.9mm (By 0.1mm) Correction Range ANGLE MEASUREMENT Method Absolute Reading Detecting System H: 2 sides V: 1 side H: 1 side V: 1 side 5″/10″ 1″/5″ Minimum Reading (1 / (0.2 / 1mgon) 2mgon) 3″ 5″ 6″ 9″ Accuracy * (1mgon) (1.5mgon) (1.8mgon) (2.7mgon) Measuring Time Less than 0.3 sec. Diameter of circle 71mm DISPLAY Dot matrix LCD 20 characters × 4 lines Display Unit with Blacklight 2sides 1side Keyboard 10 function keys TILT CORRECTION (AUTOMATIC INDEX) Single Tilt sensor Dual axis axis Method Liquid type Compensating range ±3′ Correction unit 1″ (0.1 mgon) OTHERS Instrument height 176mm(6.93in) LEVEL SENSITIVITY Circular level 10′ / 2mm Plate level 30″ / 2mm 40″ / 2mm LASER PLUMMET : STANDARD OPTICAL PLUMMET TELESCOPE (OPTION) Magnification 3× Focusing Range 0.5m to infinity Image Erect Field of view 5°(dia.114mm) (at 1.3m) DIMENSIONS 336(H) × 184(W) × 150(L)mm
[13.2(H) × 7.2(W) × 5.9(L)in.] Weight Instrument 4.9kg (10.8 lbs.) (with battery) Plastic carryng case 3.2kg (7.1 lbs.) DURABILITY Water protection IPX 6 (with BT-52QA) Ambient temperature -20°C to +50°C (-4°F to +122°F) range BATTERY BT-52QA Output voltage 7.2V Capacity 2.7AH (Ni-MH) Maximum operating time at +20°C(+68°F) Including distance 10 hours (12,000 points) measurement Angle measurement 45 hours only Weight 0.3kg (0.7 lbs.) BATTERY CHARGER BC-27BR / 27CR Input Voltage AC120(BC-27BR) AC230(BC-27CR) Frequency 50 / 60Hz Recharging Time 1.8 hours (at +20°C/+68°F) Operating +10°C to +40°C (+50°F to +104°F) temperature Weight 0.5kg (1.1 lbs.)